- smartctl 5.40 2010-10-16 r3189 [FreeBSD 9.0-CURRENT i386] (local build)
- Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
- === START OF INFORMATION SECTION ===
- Model Family: Seagate Barracuda 7200.12 family
- Device Model: ST31000528AS
- Serial Number: 9VP0HETT
- Firmware Version: CC44
- User Capacity: 1,000,204,886,016 bytes
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: 8
- ATA Standard is: ATA-8-ACS revision 4
- Local Time is: Mon Jan 10 01:06:56 2011 CET
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x82) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 600) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: ( 195) minutes.
- Conveyance self-test routine
- recommended polling time: ( 2) minutes.
- SCT capabilities: (0x103f) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 10
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 113 099 006 Pre-fail Always - 58684958
- 3 Spin_Up_Time 0x0003 096 094 000 Pre-fail Always - 0
- 4 Start_Stop_Count 0x0032 099 099 020 Old_age Always - 1539
- 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x000f 073 060 030 Pre-fail Always - 22301495
- 9 Power_On_Hours 0x0032 094 094 000 Old_age Always - 5722
- 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 099 099 020 Old_age Always - 1560
- 183 Runtime_Bad_Block 0x0000 100 100 000 Old_age Offline - 0
- 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
- 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
- 188 Command_Timeout 0x0032 100 092 000 Old_age Always - 472453611632
- 189 High_Fly_Writes 0x003a 099 099 000 Old_age Always - 1
- 190 Airflow_Temperature_Cel 0x0022 073 059 045 Old_age Always - 27 (Min/Max 23/28)
- 194 Temperature_Celsius 0x0022 027 041 000 Old_age Always - 27 (0 11 0 0)
- 195 Hardware_ECC_Recovered 0x001a 044 021 000 Old_age Always - 58684958
- 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 4
- 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 4
- 199 UDMA_CRC_Error_Count 0x003e 200 001 000 Old_age Always - 23645
- 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 90585155249333
- 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 1613735744
- 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 2209396019
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed without error 00% 5720 -
- # 2 Extended offline Completed without error 00% 5542 -
- # 3 Short offline Completed without error 00% 5474 -
- # 4 Short offline Completed without error 00% 4866 -
- # 5 Conveyance offline Completed without error 00% 2138 -
- # 6 Short offline Completed without error 00% 2138 -
- # 7 Short offline Completed without error 00% 9 -
- # 8 Short offline Completed without error 00% 0 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.