  1. smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.2.0-69-generic] (local build)
  2. Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Device Model: TOSHIBA MK5061GSY
  6. Serial Number: 411DT26AT
  7. LU WWN Device Id: 5 000039 331600490
  8. Firmware Version: MC000D
  9. User Capacity: 500,107,862,016 bytes [500 GB]
  10. Sector Size: 512 bytes logical/physical
  11. Device is: Not in smartctl database [for details use: -P showall]
  12. ATA Version is: 8
  13. ATA Standard is: Exact ATA specification draft version not indicated
  14. Local Time is: Sun Oct 5 22:49:12 2014 CEST
  15. SMART support is: Available - device has SMART capability.
  16. SMART support is: Enabled
  17.  
  18. === START OF READ SMART DATA SECTION ===
  19. SMART overall-health self-assessment test result: FAILED!
  20. Drive failure expected in less than 24 hours. SAVE ALL DATA.
  21. See vendor-specific Attribute list for failed Attributes.
  22.  
  23. General SMART Values:
  24. Offline data collection status: (0x00) Offline data collection activity
  25. was never started.
  26. Auto Offline Data Collection: Disabled.
  27. Self-test execution status: ( 0) The previous self-test routine completed
  28. without error or no self-test has ever
  29. been run.
  30. Total time to complete Offline
  31. data collection: ( 120) seconds.
  32. Offline data collection
  33. capabilities: (0x5b) SMART execute Offline immediate.
  34. Auto Offline data collection on/off support.
  35. Suspend Offline collection upon new
  36. command.
  37. Offline surface scan supported.
  38. Self-test supported.
  39. No Conveyance Self-test supported.
  40. Selective Self-test supported.
  41. SMART capabilities: (0x0003) Saves SMART data before entering
  42. power-saving mode.
  43. Supports SMART auto save timer.
  44. Error logging capability: (0x01) Error logging supported.
  45. General Purpose Logging supported.
  46. Short self-test routine
  47. recommended polling time: ( 2) minutes.
  48. Extended self-test routine
  49. recommended polling time: ( 133) minutes.
  50. SCT capabilities: (0x003d) SCT Status supported.
  51. SCT Error Recovery Control supported.
  52. SCT Feature Control supported.
  53. SCT Data Table supported.
  54.  
  55. SMART Attributes Data Structure revision number: 128
  56. Vendor Specific SMART Attributes with Thresholds:
  57. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  58. 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0
  59. 3 Spin_Up_Time 0x0027 100 100 001 Pre-fail Always - 1660
  60. 5 Reallocated_Sector_Ct 0x0033 001 001 050 Pre-fail Always FAILING_NOW 2047
  61. 9 Power_On_Hours 0x0032 065 065 000 Old_age Always - 858544
  62. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 1744
  63. 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 32
  64. 192 Power-Off_Retract_Count 0x0032 097 097 000 Old_age Always - 1614
  65. 193 Load_Cycle_Count 0x0032 099 099 000 Old_age Always - 18223
  66. 194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 49 (Min/Max 8/64)
  67. 199 UDMA_CRC_Error_Count 0x0032 100 100 000 Old_age Always - 156558023
  68. 200 Multi_Zone_Error_Rate 0x0032 100 100 000 Old_age Always - 1612531319
  69. 240 Head_Flying_Hours 0x0032 055 055 000 Old_age Always - 1088367
  70. 241 Total_LBAs_Written 0x0032 100 100 000 Old_age Always - 24322730441
  71. 242 Total_LBAs_Read 0x0032 100 100 000 Old_age Always - 30653206433
  72. 254 Free_Fall_Sensor 0x0032 100 100 000 Old_age Always - 1573
  73.  
  74. SMART Error Log Version: 1
  75. ATA Error Count: 123 (device log contains only the most recent five errors)
  76. CR = Command Register [HEX]
  77. FR = Features Register [HEX]
  78. SC = Sector Count Register [HEX]
  79. SN = Sector Number Register [HEX]
  80. CL = Cylinder Low Register [HEX]
  81. CH = Cylinder High Register [HEX]
  82. DH = Device/Head Register [HEX]
  83. DC = Device Command Register [HEX]
  84. ER = Error register [HEX]
  85. ST = Status register [HEX]
  86. Powered_Up_Time is measured from power on, and printed as
  87. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  88. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  89.  
  90. Error 123 occurred at disk power-on lifetime: 14285 hours (595 days + 5 hours)
  91. When the command that caused the error occurred, the device was active or idle.
  92.  
  93. After command completion occurred, registers were:
  94. ER ST SC SN CL CH DH
  95. -- -- -- -- -- -- --
  96. 04 51 00 f7 7b cd e0 Error: ABRT at LBA = 0x00cd7bf7 = 13466615
  97.  
  98. Commands leading to the command that caused the error were:
  99. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  100. -- -- -- -- -- -- -- -- ---------------- --------------------
  101. 35 00 18 e0 7b cd e0 00 3d+06:22:59.753 WRITE DMA EXT
  102. 35 00 18 c0 7b cd e0 00 3d+06:22:59.745 WRITE DMA EXT
  103. 35 00 08 80 78 cd e0 00 3d+06:22:59.702 WRITE DMA EXT
  104. 35 00 08 18 78 cd e0 00 3d+06:22:59.694 WRITE DMA EXT
  105. 35 00 10 00 78 cd e0 00 3d+06:22:59.644 WRITE DMA EXT
  106.  
  107. Error 122 occurred at disk power-on lifetime: 14284 hours (595 days + 4 hours)
  108. When the command that caused the error occurred, the device was active or idle.
  109.  
  110. After command completion occurred, registers were:
  111. ER ST SC SN CL CH DH
  112. -- -- -- -- -- -- --
  113. 04 51 00 d7 7b cd e0 Error: ABRT at LBA = 0x00cd7bd7 = 13466583
  114.  
  115. Commands leading to the command that caused the error were:
  116. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  117. -- -- -- -- -- -- -- -- ---------------- --------------------
  118. 35 00 18 c0 7b cd e0 00 3d+05:23:24.012 WRITE DMA EXT
  119. 35 00 08 80 78 cd e0 00 3d+05:23:23.970 WRITE DMA EXT
  120. 35 00 08 18 78 cd e0 00 3d+05:23:23.961 WRITE DMA EXT
  121. 35 00 10 00 78 cd e0 00 3d+05:23:23.831 WRITE DMA EXT
  122. 35 00 08 00 78 0d e0 00 3d+05:23:23.822 WRITE DMA EXT
  123.  
  124. Error 121 occurred at disk power-on lifetime: 14273 hours (594 days + 17 hours)
  125. When the command that caused the error occurred, the device was active or idle.
  126.  
  127. After command completion occurred, registers were:
  128. ER ST SC SN CL CH DH
  129. -- -- -- -- -- -- --
  130. 04 51 00 07 14 cd e0 Error: ABRT at LBA = 0x00cd1407 = 13440007
  131.  
  132. Commands leading to the command that caused the error were:
  133. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  134. -- -- -- -- -- -- -- -- ---------------- --------------------
  135. 35 00 08 00 14 cd e0 00 2d+17:40:47.167 WRITE DMA EXT
  136. 35 00 00 68 a6 01 e0 00 2d+17:40:47.148 WRITE DMA EXT
  137. 35 00 10 40 0a e0 e0 00 2d+17:40:47.140 WRITE DMA EXT
  138. 35 00 08 20 0a e0 e0 00 2d+17:40:47.124 WRITE DMA EXT
  139. 35 00 08 40 03 d5 e0 00 2d+17:40:46.075 WRITE DMA EXT
  140.  
  141. Error 120 occurred at disk power-on lifetime: 14273 hours (594 days + 17 hours)
  142. When the command that caused the error occurred, the device was active or idle.
  143.  
  144. After command completion occurred, registers were:
  145. ER ST SC SN CL CH DH
  146. -- -- -- -- -- -- --
  147. 04 51 00 07 15 cd e0 Error: ABRT at LBA = 0x00cd1507 = 13440263
  148.  
  149. Commands leading to the command that caused the error were:
  150. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  151. -- -- -- -- -- -- -- -- ---------------- --------------------
  152. 35 00 08 00 14 cd e0 00 2d+17:28:02.095 WRITE DMA EXT
  153. 35 00 80 e8 a6 01 e0 00 2d+17:28:02.076 WRITE DMA EXT
  154. 35 00 10 40 0a e0 e0 00 2d+17:28:02.068 WRITE DMA EXT
  155. 35 00 08 20 0a e0 e0 00 2d+17:28:02.053 WRITE DMA EXT
  156. 35 00 08 28 e0 d4 e0 00 2d+17:27:57.074 WRITE DMA EXT
  157.  
  158. Error 119 occurred at disk power-on lifetime: 14272 hours (594 days + 16 hours)
  159. When the command that caused the error occurred, the device was active or idle.
  160.  
  161. After command completion occurred, registers were:
  162. ER ST SC SN CL CH DH
  163. -- -- -- -- -- -- --
  164. 04 51 00 87 14 cd e0 Error: ABRT at LBA = 0x00cd1487 = 13440135
  165.  
  166. Commands leading to the command that caused the error were:
  167. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  168. -- -- -- -- -- -- -- -- ---------------- --------------------
  169. 35 00 88 00 14 cd e0 00 2d+16:52:55.112 WRITE DMA EXT
  170. ef 10 02 00 00 00 a0 00 2d+16:52:55.112 SET FEATURES [Reserved for Serial ATA]
  171. 27 00 00 00 00 00 e0 00 2d+16:52:55.112 READ NATIVE MAX ADDRESS EXT
  172. ec 00 00 00 00 00 a0 00 2d+16:52:55.111 IDENTIFY DEVICE
  173. ef 03 44 00 00 00 a0 00 2d+16:52:55.111 SET FEATURES [Set transfer mode]
  174.  
  175. SMART Self-test log structure revision number 1
  176. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  177. # 1 Short offline Completed without error 00% 13888 -
  178. # 2 Short offline Completed without error 00% 13461 -
  179. # 3 Extended offline Completed without error 00% 13024 -
  180. # 4 Short offline Completed without error 00% 13022 -
  181. # 5 Short offline Completed without error 00% 11006 -
  182. # 6 Short offline Completed without error 00% 10627 -
  183. # 7 Short offline Completed without error 00% 10165 -
  184. # 8 Short offline Completed without error 00% 9723 -
  185. # 9 Short offline Completed without error 00% 9222 -
  186. #10 Short offline Completed without error 00% 8888 -
  187. #11 Short offline Completed without error 00% 8411 -
  188. #12 Short offline Completed without error 00% 8176 -
  189. #13 Short offline Completed without error 00% 7792 -
  190. #14 Short offline Completed without error 00% 7695 -
  191. #15 Short offline Completed without error 00% 7139 -
  192. #16 Short offline Completed without error 00% 4128 -
  193. #17 Short offline Completed without error 00% 3587 -
  194. #18 Short offline Completed without error 00% 3225 -
  195. #19 Short offline Completed without error 00% 2829 -
  196. #20 Short offline Completed without error 00% 2828 -
  197. #21 Short offline Completed without error 00% 2485 -
  198.  
  199. SMART Selective self-test log data structure revision number 1
  200. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  201. 1 0 0 Not_testing
  202. 2 0 0 Not_testing
  203. 3 0 0 Not_testing
  204. 4 0 0 Not_testing
  205. 5 0 0 Not_testing
  206. Selective self-test flags (0x0):
  207. After scanning selected spans, do NOT read-scan remainder of disk.
  208. If Selective self-test is pending on power-up, resume after 0 minute delay.
Advertisement