  1. To deploy Tools and Drivers or HIA, please find the patchs from X4170/X4270/X4275 SW 2.4:
  2. X4170 SW 2.4 - Tools and Drivers (Patch 10630770)
  3. X4170 SW 2.4 - Hardware Installation Assistant (Patch 10633962)
  4. X4270 SW 2.4 - Tools and Drivers (Patch 10630769)
  5. X4270 SW 2.4 - Hardware Installation Assistant (Patch 10633958)
  6. X4275 SW 2.4 - Tools and Drivers (Patch 10630776)
  7. X4275 SW 2.4 - Hardware Installation Assistant (Patch 10633966)
  8.  
  9. ----------------------------------------------------------------------------------------------------------------------
  10.  
  11. Keywords Sun Fire X4170, Sun Fire X4270, Sun Fire X4275
  12.  
  13. Synopsis: Sun Fire X4170/X4270/X4275 ILOM Software release 2.6.10
  14. Date: Oct, 2016
  15.  
  16. Install Requirements: Please consult Oracle ILOM documentation and product notes for information on installing this firmware
  17.  
  18. Unbundled Product: Sun Fire X4170, Sun Fire X4270, Sun Fire X4275
  19.  
  20. Unbundled Release: 2.6.10 (Oracle ILOM 3.0.16.38.a and BIOS 07.06.03.15)
  21.  
  22. Topic: Software Release 2.6.10 for Sun Fire X4170/X4270/X4275
  23.  
  24. Patches accumulated and obsoleted by this patch:
  25. Sun Fire X4170/X4270/X4275 Oracle ILOM Software release 1.0
  26. Sun Fire X4170/X4270/X4275 Oracle ILOM Software release 1.2
  27. Sun Fire X4170/X4270/X4275 Oracle ILOM Software release 2.0
  28. Sun Fire X4170/X4270/X4275 Oracle ILOM Software release 2.0.1
  29. Sun Fire X4170/X4270/X4275 Oracle ILOM Software release 2.1
  30. Sun Fire X4170/X4270/X4275 Oracle ILOM Software release 2.1.1
  31. Sun Fire X4170/X4270/X4275 Oracle ILOM Software release 2.3
  32. Sun Fire X4170/X4270/X4275 Oracle ILOM Software release 2.3.1
  33. Sun Fire X4170/X4270/X4275 Oracle ILOM Software release 2.4
  34. Sun Fire X4170/X4270/X4275 Oracle ILOM Software release 2.5.1
  35. Sun Fire X4170/X4270/X4275 Oracle ILOM Software release 2.6
  36. Sun Fire X4170/X4270/X4275 Oracle ILOM Software release 2.6.1
  37. Sun Fire X4170/X4270/X4275 Oracle ILOM Software release 2.6.2
  38. Sun Fire X4170/X4270/X4275 Oracle ILOM Software release 2.6.3
  39. Sun Fire X4170/X4270/X4275 Oracle ILOM Software release 2.6.4
  40. Sun Fire X4170/X4270/X4275 Oracle ILOM Software release 2.6.5
  41. Sun Fire X4170/X4270/X4275 Oracle ILOM Software release 2.6.5.1
  42. Sun Fire X4170/X4270/X4275 Oracle ILOM Software release 2.6.6
  43. Sun Fire X4170/X4270/X4275 Oracle ILOM Software release 2.6.7
  44. Sun Fire X4170/X4270/X4275 Oracle ILOM Software release 2.6.9
  45.  
  46. Obsoleted by:
  47. None
  48.  
  49. Files included with this patch:
  50. ILOM-3_0_16_38_a_r112721-Sun_Fire_X4170_X4270_X4275.pkg
  51.  
  52. Description of BugID's fixed with this update:
  53. Oracle ILOM bug:
  54. 24784400 Update tzdata to 2016g version
  55.  
  56. Note: Oracle ILOM 3.0 contains many new features that are not listed here as bug fixes, please consult the Oracle ILOM 3.0 documentation for more information
  57.  
  58. For instructions on upgrading the firmware please refer to "Updating Firmware Using Oracle ILOM (CLI)" in "Maintenance and Diagnostics CLI and Web Procedures" at:
  59.  
  60. http://docs.oracle.com/cd/E19860-01/index.html
  61.  
  62. Bug ID's fixed in Sun Fire X4170/X4270/X4275 Oracle ILOM Software Release 2.6.9
  63. Oracle ILOM bug:
  64. 23615625 Malformed POST header causes high CPU utilization
  65.  
  66. Bug ID's fixed in Sun Fire X4170/X4270/X4275 Oracle ILOM Software Release 2.6.8
  67. BIOS bug:
  68. Update latest CPU Microcode M03106A5_0000001B.PDB in SRV_P_162
  69. 22507882 change sub-command codes for pending legacy BIOS check
  70. Oracle ILOM bug:
  71. 18890956 Problem with SYS-MGMT/INFRASTRUCTURE
  72. 20642443 Problem with SYS-MGMT/BACKUP-RESTORE
  73. 20668337 Problem with SYS-MGMT/RESTRICTED-SH
  74. 20698046 Problem with SYS-MGMT/WEB
  75. 21058826 Problem with SYS-MGMT/AUTHENTICATION
  76. 22140552 Problem with SYS-MGMT/INFRASTRUCTURE
  77. 22152635 Problem with SYS-MGMT/INFRASTRUCTURE
  78. 22152692 Problem with SYS-MGMT/RESTRICTED-SH
  79. 22152742 Problem with SYS-MGMT/INFRASTRUCTURE
  80. 22153091 Problem with SYS-MGMT/INFRASTRUCTURE
  81. 22153151 Problem with SYS-MGMT/INFRASTRUCTURE
  82. 22153172 Problem with SYS-MGMT/IPMI
  83. 22153209 Problem with SYS-MGMT/INFRASTRUCTURE
  84. 22153384 Problem with SYS-MGMT/WEB
  85. 22153508 Problem with SYS-MGMT/WEB
  86. 22160789 Problem with SYS-MGMT/WEB
  87. 22161303 Problem with SYS-MGMT/WEB
  88. 22161383 Problem with SYS-MGMT/WEB
  89. 22161385 Problem with SYS-MGMT/WEB
  90. 22161389 Problem with SYS-MGMT/WEB
  91. 22161390 Problem with SYS-MGMT/WEB
  92. 22161563 Problem with SYS-MGMT/WEB
  93. 22161583 Problem with SYS-MGMT/WEB
  94. 22161587 Problem with SYS-MGMT/WEB
  95. 22161603 Problem with SYS-MGMT/WEB
  96. 22161606 Problem with SYS-MGMT/WEB
  97. 22161686 Problem with SYS-MGMT/SSH
  98. 22162215 Problem with SYS-MGMT/WEB
  99. 22162216 Problem with SYS-MGMT/WEB
  100. 22698334 Problem with SYS-MGMT/IPMI
  101. 22698337 Problem with SYS-MGMT/IPMI
  102. 22698467 Problem with SYS-MGMT/IPMI
  103. 22706532 Problem with SYS-MGMT/IPMI
  104. 22706841 Problem with SYS-MGMT/WEB
  105. 22706843 Problem with SYS-MGMT/WEB
  106. 22707345 Problem with SYS-MGMT/WEB
  107. 22707405 Problem with SYS-MGMT/IPMI
  108. 22707701 Problem with SYS-MGMT/SSO
  109. 22707894 Problem with SYS-MGMT/WEB
  110. 22707929 Problem with SYS-MGMT/INFRASTRUCTURE
  111. 22708033 Problem with SYS-MGMT/LUMAIN
  112. 22708198 Problem with SYS-MGMT/IPMI
  113. 22709897 Problem with SYS-MGMT/WEB
  114. 22709973 Problem with SYS-MGMT/IPMI
  115. 22709976 Problem with SYS-MGMT/IPMI
  116. 22710036 Problem with SYS-MGMT/IPMI
  117. 22710069 Problem with SYS-MGMT/IPMI
  118. 22710117 Problem with SYS-MGMT/LUMAIN
  119. 22710196 Problem with SYS-MGMT/RESTRICTED-SH
  120. 22710353 Problem with SYS-MGMT/RESTRICTED-SH
  121. 22710399 Problem with SYS-MGMT/WEB
  122. 22710524 Problem with SYS-MGMT/INFRASTRUCTURE
  123. 22710630 Problem with SYS-MGMT/RESTRICTED-SH
  124. 15988468 ipmitool sunoem getval is disabled when lumain restarts
  125. 16020720 SUNBT7104892-3.0_SP16 need to update timezone database files for daylight saving
  126. 16020832 SUNBT7159072-3.0_SP16 Exadata x2-2 x4x70/m2 ILOM Asia/Dhaka timezone is hour off
  127. 16021061 SUNBT7207539-TRUNK Fix thread error message when using ilom_build_platforms.pl
  128. 16443474 SUNBT6937513-TRUNK Ldap Can't start cli from CH as an ldap user, using Single Si
  129. 16532528 SUNBT7191992-3.0.16.22 Uboot should display a "reason text" before dropping into
  130. 19484187 sp faulted because snmpd logs fill /var/log filesystem to capacity
  131. 19708046 slow web https access on version 3.1.2 with ssl_proxy support only
  132. 19708047 Web/gui access with ILOM v3.1.2.20.c and Chrome browser
  133. 19807056 : P2 : silent memory map out
  134. 19881065 enable logrotate for /var/log/libfishwrap.log
  135. 20037907 issues observed when verifying Fail to enter escalation mode due to TLI behavior
  136. 20230046 SUNBT7038879-3.1 AST CMM lumain hung and SNMP cored
  137. 20355268 GETBULK size handling issues
  138. 20457254 "pidof -x" has stopped working
  139. 20604127 JRC tokend shall have the same socket attributes as https
  140. 20888741 Convert internal scripts to use https to access the svn server
  141. 22129362 SUNBT7021998 Cannot "ls misc/XXX"
  142. 22129363 SUNBT7027924 showpsnc does not work from restricted shell
  143. 22129365 SUNBT7030965 Restricted shell not respecting "safe" wrapper programs
  144. 22152554 sunHwTrapDiagEntity should not be included in sunHwTrapHeartbeat
  145. 22152555 Add ILOM host information to the ILOM test fault trap
  146. 22153379 Javascript encoding problem
  147. 22153539 JS error on powerlimit page
  148. 22160393 Need utility libraries (libarraytuils, libstingutils, libsysutils) backported.
  149. 22161195 Ignore River platforms in ilom_build_platforms.
  150. 22161472 Javascript errors on ldap and host control pages
  151. 22161644 JS error on i_sparcDiag.asp
  152. 22162218 Add error check for proper security in Web RPC files
  153. 22530530 change sub-command codes for pending legacy BIOS check
  154. 22706673 If no IPv6 static gateway change, network/commit should not cause webgo restart
  155. 22706674 Invalid characters are accepted in IPv6 address/gateway prefix
  156. 22708105 Alignment Trap in IPMI LAN
  157. 22708196 SUNBT7056256 IPMI to Active-IP doesn't work
  158. 22710071 IPMI 1.5 Protocol does not save the source and destination address
  159. 22710477 BIOS will not flash during next warm reset if select delaybios when upgrade FW.
  160. 22717260 Home directory not set when creating ILOM user.
  161. 22717331 SUNBT7007032 Use an "ILOM" prompt when in escalation mode.
  162. 22730490 Unable to launch serial redirection from BUI
  163. 22884112 Regression with CapiProcess
  164. 22884129 Updating Exalogic X2-2 from 2.0.x.x.x to 2.0.6.2.x loses ILOM Network settings
  165. 22884153 Changing ipdiscovery from dhcp to static with port unplugged needs state enabled
  166.  
  167. Bug ID's fixed in Sun Fire X4170/X4270/X4275 Oracle ILOM Software Release 2.6.7
  168. Oracle ILOM bug:
  169. 21557468 Eng. systems need custom fdr for psu redundancy
  170. 21557377 In platforms supporting sideband, lumain coredump detected - 3.0.16 only
  171. 21498140 IPv6 dynamic address missing after merge of static default gateway
  172. 21498201 When network state set to ipv6-only, IPv6 static addresses are not used
  173. 21497957 Problem with SYS-MGMT/WEB
  174. 21497967 Problem with SYS-MGMT/INFRASTRUCTURE
  175. 21497865 Need ability to disable IPv4
  176. 21497684 Provide ability to set ipv6 gateway when autoconfig is disabled
  177.  
  178. Bug ID's fixed in Sun Fire X4170/X4270/X4275 Oracle ILOM Software Release 2.6.6
  179. BIOS bug:
  180. 20090383 Add Oracle ILOM check and flash pending BIOS on reboot/warm reset initiated by host
  181. 18766295 Set default Product Name in SMBIOS.
  182. Oracle ILOM bug:
  183. 21024006 Problem with SYS-MGMT/WEB
  184. 21024014 run snapshot fail through ftp/sftp protocol on Oracle ILOM web page.
  185. 20944486 Problem with SYS-MGMT/WEB
  186. 20944465 Unable to login via HTTP
  187. 20938624 Problem with PLAT-SW/NETWORK
  188. 20668525 Problem with SYS-MGMT/RESTRICTED-SH
  189. 20872354 Problem with SYS-MGMT/RESTRICTED-SH
  190. 20668207 Sun Fire X4170: The sensor 'Fan FB1/FM3/PRSNT' causes an -2 error in OEM
  191. 20626035 Problem with SYS-MGMT/RESTRICTED-SH
  192. 20642128 Fix for CVE-2015-0235
  193. 20642266 Can't use Remote System Console when SSLv3 is disabled in Java
  194. 20642601 Configuration restore does not handle empty entries correctly
  195. 20642602 Problem with SYS-MGMT/BACKUP-RESTORE
  196. 20642613 An error event in Oracle ILOM restore only shows "/X/*" instead of "/SP/*".
  197. 20642774 Exadata X2-2/X4270M2 dynafrud is dying in a loop
  198. 20668461 SUNBT7003809 Provide additional shell commands in Restricted Shell
  199. 20668462 SUNBT6992501 arguments to "echo" should be checked in restricted shell
  200. 20668464 SUNBT7003810 Can't use quotes with restricted shell commands.
  201. 20668520 SUNBT7206309 Entering Restricted Shell puts "echo" messages into the audit log
  202. 20698068 Problem with SYS-MGMT/WEB
  203. 20098581 remote console permission manifest attribute M2.JAR message when launch
  204. 20098831 CLI crashes depending on banner configuration
  205. 20098966 SFCB does not build on OL6
  206. 20099332 Can't use static linking with OEL6
  207. 20099392 Build fails on OL6 in libstringutils
  208. 20100102 Flash Accelerator F20 1.0 ESM SERVICE LIFE is changed by SP reset, or a few days later
  209. 20100198 ipmitool lan print displays the incorrect cipher suites
  210. 20100256 Unable to disable the user completely from ipmitool
  211. 20100335 ilom_build_platforms occasionally hangs when running parallel jobs
  212. 20100403 Can't enable the network state on the Oracle ILOM:set state=enabled,set: Command Failed
  213. 20100579 Problem with SYS-MGMT/NTP-AND-CLOCK
  214. 20099827 X5-2 Support BIOS Upgrade During Warm Reset
  215.  
  216. Bug ID's fixed in Sun Fire X4170/X4270/X4275 Oracle ILOM Software Release 2.6.5.1
  217. 19791663 - Bash Shellshock Command Injection Vulnerability (CVE-2014-6271 and CVE-2014-7169)
  218.  
  219. Bug ID's fixed in Sun Fire X4170/X4270/X4275 Oracle ILOM Software Release 2.6.5
  220. 17783557 When Hyperthreading disabled, BIOS hangs in single CPU hardware configuration
  221. 16211163 Add remote host information on ipmi chassis control request in audit logs
  222. 17018199 Oracle Database Appliance : Next boot device and persistent mode
  223. 16499247 provide Oracle ILOM heartbeat trap
  224. 17265880 Null pointer reference in sunoem cli cause seg fault+coredump of IPMI Msghndlr
  225. 15802967 SUNBT7183096-3.2_SP01 tokend shall support user downloaded certificates and keys
  226. 17544746 lumain crash when login from web as invalid user if RADIUS server is configured
  227. 16839186 Oracle ILOM 3.2 Fails to enter escalation mode due to TLI behavior changed
  228. 15808055 SUNBT7189051 Change policy for automatic update of Key Identity Properties
  229. 17489082 Update Oracle ILOM TimeZone data to pull in recent changes (new DST for Israel, Chile)
  230. 17490184 Display issues with IE10 on BUI
  231. 15959952 Add SP version information to sunHwTrapFaultDiagnosed
  232. 16802593 AST: Disable Weak Ciphers from TokenD
  233. 15756918 SUNBT7114854 Oracle ILOM https hang with MSIE9 and Firefox8
  234. 17816477 [X3-2/B]Downgraded Oracle ILOM firmware failed via webgui.
  235. 17874610 Java 7u51 requirements for RIAs
  236.  
  237. Bug ID's fixed in Sun Fire X4170/X4270/X4275 Oracle ILOM Software Release 2.6.4
  238. 16898008 Sun Fire X4170 implement IOH errata 53
  239. 16904598 CDROM redirection fails to work after Oracle Database Appliance image is installed over it
  240. 16904888 M4 Longterm Test fdd leaking memory
  241.  
  242. Bug ID's fixed in Sun Fire X4170/X4270/X4275 Oracle ILOM Software Release 2.6.3
  243. 16406553 SLES 11 SP2 : Hyperthreading enabled at power off.
  244. 16402650 The nac type should be "const char *" to avoid modification in pod and libfrutool
  245. 16406986 SunHwTrapMibGetSystemIdentifieifier failed error messages in /var/log file
  246. 16034067 Oracle ILOM event logged for power reset is incorrect
  247. 16420529 Fault critical timestamp is off by one hour
  248. 16420117 Two login prompts are seen after SP boot
  249. 16421543 SP resets on Memory CE storm
  250. 16423214 Status_Current write fail if Status_EventsR absent; possible FRU corruption
  251. 16034067 Oracle ILOM event logged for power reset is incorrect
  252.  
  253. Bug ID's fixed in Sun Fire X4170/X4270/X4275 Oracle ILOM Software Release 2.6.2
  254. 7190040 Internal LSI raid card cannot be seen with Oracle ILOM firmware 3.0.9.19.e and above in slots 1,4,2,5
  255. 7171081 lumain cores seen attempting to dump /SP/config
  256. 7154901 CPUs are stuck at the capped frequencies when switching from softcap to hardcap
  257.  
  258. Bug ID's fixed in Sun Fire X4170/X4270/X4275 Oracle ILOM Software Release 2.6.1
  259. 7160217 Sun Fire X4170 with Intel Niantic FCoE performing SAN-Boot adds 10 mins to 2 hrs to boot cycle
  260. 7147353 x8 PCIE Gen1 cards are trained as x4 on Lynx2U
  261. 7167805 Warm resets during POST result in spurious DIMM faults being logged
  262. 7130034 ipmitool sunoem cli command fails intermittently (kcs errors in /var/log/messages)
  263. 7119039 Need ability to disable logging of host console
  264. 7086029 /var/log file system full causing SP fault
  265. 7072836 Windows Server 2008 R2 Checked Build does not boot Mensa when SP 1 and SP 2 USB ports are enabled.
  266. 7077771 PC-Check diag setting is still enabled after SP is reset to default.
  267. 7015485 parse_multi_sensor_list() may not enumerate all sensors
  268. 7114906 find_blob_in_flash coredumps if it tries to extract to an invalid file.
  269. 7057293 fault.memory.intel.dimm.none comes up when doing power cycle testing on Virgo+
  270. 7134783 Exadata - OVERFLOODING ALERT LOG IN CELL IMAGE
  271. 7132854 X4270 /SYS/VPS power consumption value almost doubled after firmware update to SW 2.6
  272. 7110426 need remove platform_inventory.dat on 3.0.16.15
  273. 7129467 Exadata - SYSTEM FAILS TO POWER ON AFTER POWER IS RESTORED
  274. 7147430 Exadata needs ipmi cmds to turn on (solid) OK2RM & SERVICE LEDs - implement PRMS-29/30
  275. 7115530 prtfru -n: "Alignment trap" messages flood /var/log/messages
  276. 7116351 clearfru: error messages in /var/log/messages if the target fru is absent.
  277. 7113149 Install records are written for every boot for 8PN FRUs if parent description is long
  278. 7157579 Problem with sys-mgmt/infrastructure
  279. 7078121 fruupdate for PwrMgmt_RFR dumps core in sysFW 8.1.0.c
  280. 7151223 memstore does not handle keys which hash to same value
  281. 7089673 Support listing where the power-cycle/hard reset/power off/power on Oracle ILOM message came from and how
  282. 7042634 stlistener failed to bind to TCP port 6481
  283. 7142527 Sun Fire X4270 M2 (Exadata) Oracle ILOM 3.0.16.10 dynafrud leaking memory
  284. 7121012 Problem with platform-sw/linux
  285. 6986915 virtual USB report wrong bInterval
  286.  
  287. Bug ID's fixed in Sun Fire X4170/X4270/X4275 Oracle ILOM Software Release 2.6
  288. 7044502 BIOS change request for two internal settings in IDT switch for IDT Reset issue
  289. 7073871 Screen goes blank after run reboot command in OVM2.2 OS
  290. 7105873 BIOS need adding SPD accessing lock feature due to Oracle ILOM changing the related mechanism
  291. 7107423 SMBIOS type 3 Chassis types should be Rack mount Chassis(17h)
  292. 6854798 Console cannot login when 10 lumain sessions are active.
  293. 6927400 Temporary file changes for LDAPSSL and Active Directory to prevent empty files on close failures
  294. 6936396 Oracle ILOM 3.0.6 -> 3.0.9 will cause UUID change in SMBIOS
  295. 7005494 Remove various options from spdiag pwr/gpio commands in restricted shell
  296. 7014297 backup/restore not restoring files /conf/pam_* correctly causing ldapssl auth to fail
  297. 7018299 SNMP requests - 'Timeout: No Response' when host is powered off.
  298. 7025419 Oracle ILOM cann't refresh active riser fru info when riser was removed or inserted.
  299. 7036723 show /System on a Nashua system causes constant memory growth
  300. 7064224 Oracle ILOM write 0x00 to 0x05 in U0201(PCA9555) to cover some violation case of quick pull/push AC cord.
  301. 7065569 Need to customize NTP version string.
  302. 7066153 Oracle ILOM spsh hung, lumain must be restarted
  303. 7082194 Oracle ILOM 3.0 WebGUI doesn't work with Firefox 6.
  304. 7082428 10 concurrent ssh sessions causes Oracle ILOM to dump core
  305. 7085897 reboot can hang at "Unmounting local filesystems..."; hole in watchdog flow
  306. 7086123 fru_part_number has an extra "-" at the end for 8PN and bilingual FRUs
  307. 7087740 3.0.16: No spdiag in restricted-shell
  308. 7088413 Oracle ILOM fdd does not diagnose ereport.cpu.intel.internal_timer to a faulted component
  309. 7089740 IE 9x browser unable to input user name when adding new user
  310. 7095394 lv_cpld_update.sh tool works incorrectly.
  311. 7095808 No CPLD target in Oracle ILOM
  312. 7096694 No fault created when /var/log filesystem has exceeded capacity limit.
  313. 7099430 SMBIOS type 1 system UUID is not match against Fru UUID
  314. 7100258 tokend memory leak
  315. 7100904 Please add the dynamic fru function of /SYS/MB/RISER[x]
  316. 7101110 Exadata - A generic sensor has detected an error
  317. 7101663 Failed to run command "hostdiags host_rst"
  318. 7102046 Please hide the control options of "spdiag volt" command in restricted shell.
  319. 7103452 Needn't reset sp to refresh the DIMM's fru info after DIMM changed
  320. 7104969 Lost capisimload command
  321. 7105001 See extra error logs during sp reboot process via serial console
  322. 7105600 File(s) not removed when XCP transfer fails
  323. 7105921 Please add capiflttest command
  324. 7106645 "spdiag temp" command show error temperature sensor.
  325. 7107079 Host doesn't shutdown when temperature over "upper_nonrecov_threshold"
  326. 7110429 enable bios to send the request access of dimm spd
  327.  
  328. Bug ID's fixed in Sun Fire X4170/X4270/X4275 Oracle ILOM Software Release 2.5.1
  329. 7012459 "umount: /conf: device is busy" on console during SP reset.
  330. 7023454 X4170 fan failure powers down the host after 30 seconds (SPEC mentions 1 Minute)
  331. 7015874 Fru info of active riser cann't shown via ipmitool
  332. 7022392 X4275:SP cann't show the correct info when remove a fan module.
  333. 7022422 Many logs bring up after repair a faulty.
  334. 7026225 Lost fru info of FB0 of hyde.
  335. 7015870 Webgui died when the gateway's value is invaild
  336. 7058417 All PCIe cards train at Gen1 speed
  337. 7064281 Linux reports "Failed to disable AUX port, but continuing anyway..."
  338. 7064468 x4170 system hangs after cntl-A to enter BIOS level raid utility with SW 2.4 firmware release
  339. 7025419 Oracle ILOM cannot refresh active riser fru info when riser was removed or inserted.
  340. 6985970 "spdiag i2cbus"command failed to access CPU[x] DIMM[y] SPD
  341. 7021710 SP/NET0's macaddress didn't do the corresponding change after MB/NET0's macaddress changed
  342. 6801690 Problem with sys-mgmt/snmp
  343. 6934125 Oracle ILOM faulty status and alarm_status should not disagree, even if a user clears faults
  344.  
  345. Bug ID's fixed in Sun Fire X4170/X4270/X4275 Oracle ILOM Software Release 2.4
  346. 6983773 dmesg shows error info in OLE5.5 with new kernel
  347. 6985969 "spdiag_lynx pwr"command cann't power off host.
  348. 6982224 ipmitool sdr entity "Add-in Card" does not show a FMOD in PCI Slot#4 on X4275
  349. 6988195 TEMP_FAULT led also off when the temperature of MB/T_AMB above to "upper_critical_threshold".
  350. 6922052 Can set OK2RM led lit during sp downgrade flashing process.
  351. 6937992 Fail to change bios setting on External Serial Port
  352. 6955355 Can't correctly brought up the HDD's sel logs.
  353. 6984501 "APCI Error", "AE_NOT_FOUND" in dmesg on OEL5.5 and SLES11SP1
  354. 6890539 BIOS should not allow blade host to be powered on if there is no response to cpu power message.
  355. 6918382 OEL Exadata panic on boot: NMI Watchdog detected LOCKUP on CPU 3
  356. 6914083 Hot key F1~F12 in SP console will enter/exit expert mode
  357. 6947151 Sun Blade X6270 has 27 millisecond pause on all cores (SMI) when a memory CE is passed to SP
  358. 6947478 Sun Blade X6270 SP logs memory CE ereports at a much lower rate than solaris
  359. 6947483 Sun Blade X6270 Uncorrectable memory diagnosis is not very reliable.
  360. 6966635 Need modify MRC code to aviod to cause misdiagnosis of memory errors duringThen subseq DDR3 training
  361. 6992328 No MRC error report for no DIMM. (BIOS23 is OK)
  362. 7002713 Sun Fire X4170/Sun Blade X6270 DIMM and channel numbers in UE log don't match MC8_misc and MC8_status information
  363. 7002714 Sun Blade X6270 DIMM and channel numbers in UE log don't match MC8_misc and MC8_status information
  364. 6735375 [OutofOptionROM]: onboard zoar ethernet loads its option ROM last
  365. 6940436 "Discard Changes and Exit" will not revert the change of "Restore on AC Power Loss" option
  366. 6984493 Cannot save customized boot order
  367. 6988204 WHEAHCT test failed with BIOS25
  368. 6994428 2 machines encounter system hang at POST
  369. 6995973 Clearing cmos or ipmi set bootdev will cause BIOS to skip LSI option ROM scanning
  370. 6929646 SLES11 cannot recognize IB-HCA PEM x1288A-Z
  371. 6985255 "\_SB_:_OSC invalid UUID" in sles11sp1 dmesg
  372. 6995977 Southbrige Configuration is missing from BIOS Setup Menu in BIOS26/27
  373. 6990498 SMBIOS errors in BIOS25
  374. 6961368 Oracle ILOM 3.0.9.19.a fails to show output on /SP/console if F12 is sent too soon after poweron
  375. 6987437 LSI controller lost when update BIOS from23 to 25
  376. 6935795 Exadata storage system is functioning normally but front OK LED is off
  377. 6879265 /SYS/VPS is showing 0 watts when host is off for the 1u Sun Fire X4170
  378. 6995980 Default boot order is different from "Optimal Default Settings" on Sun Fire X4170 with LSI HBA
  379. 6995346 Oracle ILOM does not allow for setting of ilomCtrlAlertType to snmp using snmpset on Oracle ILOM 3.0.9.19.a
  380.  
  381. Bug ID's fixed in Sun Fire X4170/X4270/X4275 Oracle ILOM Software Release 2.3.1
  382. 6949367 prtfru print incorrect SPD_Synthesized_Serial_Number in DIMM SPD.
  383. 6890076 memory leaks in capi faults rpc interfaces
  384. 6909249 dynafrud, cdserver, webgo, and ipmikill died during overnight ipmi stress test
  385. 6888350 Numerous pod cores while power-cycling host with PcCheck enabled
  386. 6949493 healthd leaks memory when /var/log full
  387. 6946636 memory leaks in pod rpc
  388. 6914115 [watch up]update Oracle ILOM withe preserve config will cause the unit of powerlimit from Watts to percent
  389. 6949362 3.0.10->3.0.8, 3.0.9->3.0.6 downgrade with preserving config sometimes causes Oracle ILOM unusable.
  390. 6946389 Review and fix sensor "Nominal" values
  391. 6917153 Service tag <product_defined_inst_id> does not match /SYS product_serial_number
  392.  
  393. Bug ID's fixed in Sun Fire X4170/X4270/X4275 Oracle ILOM Software Release 2.3
  394. 6911078 Sun Fire X6270 openipmi driver does not work with SLES 10 SP2
  395. 6849414 X4170 will not pass POST with HP KVM attached
  396. 6913490 onboard SSD 32GB is recognized as 563.0TB in BIOS
  397. 6862063 SW2.0 - BIOS does not warn, load/save optimal defaults, and continue
  398. 6913464 CTRL-N on X4170 is causing permanent change to boot order with PXE first, instead of one-time change
  399. 6879223 The CPUS are running at Pmin during the power-on when SP is in preboot
  400. 6887840 BIOS 07.06.02.15, build date not updated
  401. 6855816 BIOS incorrectly reporting capacity of 200GB SATA disks
  402. 6872940 SMBIOS tables show PCIe slots occupied when they are empty
  403. 6914788 DIMM type "DDR3" should be indicated in SMBIOS type 17
  404. 6899860 IDT switch configuration on active riser may be incorrect (de-emphasis setting)
  405. 6902542 BIOS needs to follow the IOH BIOS Specification for thermal throttling initilization
  406. 6919366 IDT active riser PCIE Gen2 custom setting when Qlogic (QLE2562) card is detected
  407. 6915170 OEMB table has incorrect checksum
  408. 6920825 SW2.3: In RHEL5.4 64bit, dmesg shows 'ERROR: Invalid checksum' by using bios 07060221
  409. 6889075 Sun Blade X6270 setting Redirection after POST to "disabled" hangs BIOS/POST
  410. 6913498 BIOS default value of serial port baudrate is now 115200, which should be 9600
  411. 6893881 QS: System does not start after OS initiated reboot
  412. 6914352 Memory leak found during longevity test
  413. 6924035 No /SYS/LOCATE in Web BUI
  414. 6923446 Prevent user_attr/radius/ldap fclose errors from emptying the file contents
  415. 6914322 Active RKVMS sessions are disconnected after over night test runs, but can be reconnected
  416. 6915022 JRC Client leaves TCP connections open on many conditions.
  417. 6924806 XP client Javaws for RKVMS session will consume 99% of CPU when session becomes disconnected from SP
  418. 6914608 Virtual Floppy lost from boot list during power-cycle/PCCheck testing
  419. 6911068 memstore seg faults when --insert is used without a --type
  420. 6858367 Provide x6270 with HDD FRU data reports via CLI, IPMI, SNMP and WEBGUI.
  421. 6925172 In box faults that are diagnosed by Oracle ILOM "fdd" are not persistent after cold boot.
  422. 6915710 clear SYS/fault fails, causes SYS to momentarily vanish and pod to crash.
  423. 6916999 BIOS and SP report UE error in wrong pcie slot
  424. 6903003 dimm faults are not persistent across SP reboots
  425. 6913847 Failed to power cycle host via ipmitool and web during the BIOS posting process.
  426. 6821378 No power on failed reason event logged when fan col fault is present
  427. 6917619 need msgid for fault.chassis.device.esm.eol.exceeded
  428. 6899649 Incorrect "MB/R#/PCIE#/P" log entries when PCIE card is absent
  429. 6884100 The host still can be powered on when available_power is 0
  430. 6895380 chassis power cycle fails when there is a pending BIOS update (delaybios)
  431. 6913396 Failed to power cycle host from BUI
  432. 6913495 SP failed to Sync up Power restore policy with BIOS from CLI and BUI
  433. 6915205 Sun Fire X4170: should support Flash Accelerator F20 card
  434. 6934009 PCIE2 got similar entry as Arua card's even there is no Arua card on it
  435. 6914065 Reset SP sometimes cause host power off
  436. 6921208 Got a lot of FAN "going low/high" log during SP reset
  437. 6924536 No fault type event logs in sp when remove and re-insert FM6&FM7 of C48.
  438. 6936396 Oracle ILOM 3.0.6 -> 3.0.9 will cause UUID change in SMBIOS
  439. 6926756 PS_FAULT and SERVICE LEDs are OFF even with single Power Supply Unit activate after cold start
  440. 6918650 Installation record of container /SYS/MB report the wrong parent info
  441. 6920412 Lost " HOST_AUTO_POWER_ON" property of /SP/policy on x6270.
  442. 6920826 Parent info of installation record of container /SYS/MB/RFEM0 is empty.
  443. 6920838 Parent_Serial_Number of installation record of container /SYS is wrong.
  444. 6922991 Oracle ILOM snapshot should collect host_debug_error.log
  445. 6899224 The NEW Oracle ILOM BUG about the SP MAC address programming. (Not only the Oracle ILOM2.0, but also the Oracle ILOM3.0)
  446. 6914768 RFEM Board serial number changed after Oracle ILOM firmware update
  447. 6914775 blade lost rack_location after SP firmware update
  448. 6883276 BUI, rkvms failure, "mount: wrong fs type" of /usr/local/www after unconfig all
  449. 6883268 After unconfig all, "Wrong www CRC" message in early SP boot
  450. 6885603 Wasp: JAR doesn't be signed
  451. 6921188 MRC error message from BIOS cause etcd coredump.
  452. 6905219 got i2c failures when displaying led status via spdiag, system on
  453. 6924480 CAPI get/next emulation is slow / add caching
  454. 6928434 dynafrud crashing when capidirectfe returns not found
  455.  
  456. Bug ID's fixed in Sun Fire X4170/X4270/X4275 Oracle ILOM Software Release 2.1.1
  457. 6870121 displaying led status using spdiag, generates i2c failures
  458. 6899224 The NEW Oracle ILOM BUG about the SP MAC address programming.
  459.  
  460. Bug ID's fixed in Sun Fire X4170/X4270/X4275 Oracle ILOM Software Release 2.1
  461. 6762668 /SYS/VPS reading should be more accurate and timely
  462. 6806440 Sun Fire X4170 1U - PCI slot numbers in BBS menu incorrect with Pentwater installed
  463. 6813641 Sun Fire X4270 - Max PCIE config using Pentwater hba's - host resets due to caterr
  464. 6814296 Restore from GUI - Error message should be displayed when operation fails
  465. 6815049 LdapSsl: diag message misleading since it states 'ActiveDirectory'
  466. 6819100 L/V Oracle ILOM 3.0: BUI failing to configure sideband MAC address for DHCP assignment
  467. 6823914 System hang when upgrading Oracle ILOM using ipmiflash -I pci from Linux host
  468. 6826348 Warn if sunservice account is active.
  469. 6828567 Javaws for a RKVMS session will consume 100% of cpu when session disconnects from SP
  470. 6828858 RFE: Request to be able to use password length up to 36 characters in the Oracle ILOM BUI.
  471. 6828907 RKVMS session hangs when Redirection "New Session" menu is left idle while video frames change
  472. 6831089 eventmgr leaking file descriptors
  473. 6832696 LdapSsl? Configuration: Poor choice for the default 'bindpw'
  474. 6833042 JRC - video freezes for other clients when a network connection is dropped on one client
  475. 6833094 Inconsistent behavior with optionalUserMapping/bindpw
  476. 6833199 Can't set the boot device via web/cli if the 'root' user is deleted.
  477. 6836442 Mouse device redirection shows inactive for device which is working via RKVMS
  478. 6836961 During networking congestion RKVMS clients receive Video redirection error
  479. 6838588 Need ability to change sunservice password
  480. 6839546 AST2100 SPs that support sideband mgmt have MAC part of GUID change when mgmt port is changed
  481. 6844023 Sun Fire X4170/Sun Blade X6270: Modify PXE Device Boot Order
  482. 6846082 SW3.0 RKVM flaky behavior with multiple sessions open
  483. 6846923 BIOS fails to send bootlist to Oracle ILOM if there are no bootable devices
  484. 6847663 Regression: SP/ipmibootlist does not work with BIOS in Oracle ILOM3.0. Works in 2.0.29
  485. 6847776 /SP/network/dhcp_server_ip displays server info even when discovery is 'static'
  486. 6849070 Sun Fire X4170/Sun Blade X6270: AMI DMIedit tool should update SMBIOS Type 11 Structure
  487. 6849437 Active RKVMS session hangs during network congestion while video frames are changing
  488. 6850456 Dimms missing from /SYS/MB/P0 (P1)
  489. 6853505 RKVMS-Deleting Session and then creating a New Session to same the SP hangs at connecting
  490. 6854094 JRC - Using invalid username and password causes incorrect error message
  491. 6854190 Sun Fire X4170: The /SP/powermgmt/powerconf allocated_power values do not add up to hwconfig_power
  492. 6854502 Net 2 Nic Port (vmnic3) disabled when ESX 3.5U4 installed on X4170
  493. 6855019 JavaRConsole, exception occurs while creating a new session
  494. 6855316 Sun Fire X4170: dimm allocated power values gets reset to 0 after an SP reboot
  495. 6855352 adviserd commits suicide when portscanned
  496. 6860955 Sun Fire X4170/Sun Blade X6270: Better explanation on BIOS splash screen for use of CNTL-E to invoke BIOS Setup
  497. 6861981 Sun Fire X4170/Sun Blade X6270: bios needs to set INPUT_KEY_CLAIMED_BIT to eat control characters during post
  498. 6862355 Lumain crashes on Sun Fire X4170
  499. 6863930 Better error message when host fails to power on due to insufficient power
  500. 6866162 A217 PSU I2C unresponsive after long runs
  501. 6874874 Sun Fire X4170: PSU fan faults that occur before SP startup are not recorded
  502.  
  503. Bug ID's fixed in Sun Fire X4170/X4270/X4275 Oracle ILOM Software Release 2.0.1
  504. 6840570 Sun Fire X4170/Sun Blade X6270: Implement SMM Fix
  505. 6850424 powermgt not calculating DIMMs when reporting permitted and available power
  506. 6862764 Host gets hosed (corrupt BIOS) when SP FW is upgraded using preboot and soc-flash
  507. 6821501 jumpstart installation freezes on P1.last Sun Fire X4170 and Sun Blade X6270
  508. 6843541 NMI not working on Sun Fire X4170 or Sun Blade X6270 for Windows
  509. 6849020 SMBIOS Conformance: Type 19 (Memory Array Mapped Address) Start/End Address Range Error
  510. 6852639 SMBIOS Type 16 Tables (Physcial Memory Array) max memory config incorrect
  511.  
  512. Bug ID's fixed in Sun Fire X4170/X4270/X4275 Oracle ILOM Software Release 2.0
  513. 6795685 New UCD requirement to fast blink green LED during SP boot
  514. 6801273 /SYS/product_name should specify a single model
  515. 6808188 Fan module fault LED does not clear after replacing defective fan module
  516. 6812106 SP gets I2C read errors incorrectly accessing certain sensors.
  517. 6818433 Show Results Summary/Write Results Report hangs PCCheck after advanced USB controllers test
  518. 6822776 Memory UEs on P1 not being reported to the SP.
  519. 6829573 Integrate Intel MRC and MCU
  520. 6799563 Integrate 2DPC@1333 Memory Support
  521.  
  522. Bug ID's fixed in Sun Fire X4170/X4270/X4275 Oracle ILOM Software Release 1.2
  523. 6824017 root port XPUNCERRMSK programming incorrect
  524. 6813210 update snapshot.conf with hostdiags pcd
  525. 6836453 spdiag does not detect fan speeds correctly
  526. 6791563 keepalive restarts processes unnecessarily
  527. 6793992 lumain grows over time
  528. 6782321 SP: Out of Memory: Killed process(es)
  529. 6787190 sp ran out of memory when many connection to the sp are opened
  530. 6789243 Apparent memory leak in xxx_set_fault_data/xxx_clear_fault_id
  531. 6815536 frutool: stale /conf/*.fru files persist if a fru is removed
  532. 6787190 sp ran out of memory when many connection to the sp are opened
  533. 6713949 Fail to start Video redir, logging in to x.x.x.x as status
  534. 6814810 No video frames are displayed after leaving sessions up
  535. 6814251 No video frames are displayed when client network is disconnected
  536. 6817227 capidirect: sensor logical number to sensor string ID translation is incorrect
  537. 6810548 On chassis with 1 CPU, fans run at 80% PWM min should run at 40% PWM min
  538. 6817307 fan control tach conversion in libcapidirect could result in div by 0
  539. 6811329 Need to run CMA upon receipt of MRC ERR_NO_MEMORY
Add Comment