- === START OF READ SMART DATA SECTION ===
- Error SMART Status command failed: Input/output error
- SMART overall-health self-assessment test result: PASSED
- Warning: This result is based on an Attribute check.
- General SMART Values:
- Offline data collection status: (0x80) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: (15660) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 182) minutes.
- Conveyance self-test routine
- recommended polling time: ( 5) minutes.
- SCT capabilities: (0x3037) SCT Status supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x002f 100 253 051 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0027 186 176 021 Pre-fail Always - 3691
- 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 22
- 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x002e 100 253 000 Old_age Always - 0
- 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 6
- 10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always - 0
- 11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 20
- 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 15
- 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 6
- 194 Temperature_Celsius 0x0022 114 109 000 Old_age Always - 33
- 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 4
- 198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
- 200 Multi_Zone_Error_Rate 0x0008 100 253 000 Old_age Offline - 0
- SMART Error Log Version: 1
- ATA Error Count: 46 (device log contains only the most recent five errors)
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 46 occurred at disk power-on lifetime: 5 hours (0 days + 5 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 08 c1 ec 84 e0 Error: UNC 8 sectors at LBA = 0x0084ecc1 = 8711361
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 08 c0 ec 84 e0 08 00:02:03.035 READ DMA
- ec 00 00 00 00 00 a0 08 00:02:03.026 IDENTIFY DEVICE
- ef 03 46 00 00 00 a0 08 00:02:03.026 SET FEATURES [Set transfer mode]
- Error 45 occurred at disk power-on lifetime: 5 hours (0 days + 5 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 08 c1 ec 84 e0 Error: UNC 8 sectors at LBA = 0x0084ecc1 = 8711361
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 08 c0 ec 84 e0 08 00:02:01.296 READ DMA
- c8 00 08 d0 e8 84 e0 08 00:02:01.293 READ DMA
- c8 00 08 e8 e8 84 e0 08 00:02:01.292 READ DMA
- c8 00 08 f0 e8 84 e0 08 00:02:01.291 READ DMA
- Error 44 occurred at disk power-on lifetime: 5 hours (0 days + 5 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 40 fd ab 84 e0 Error: UNC 64 sectors at LBA = 0x0084abfd = 8694781
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 40 c0 ab 84 e0 08 00:01:51.523 READ DMA
- c8 00 20 a0 ab 84 e0 08 00:01:51.523 READ DMA
- c8 00 08 98 ab 84 e0 08 00:01:51.523 READ DMA
- c8 00 40 d8 ac 84 e0 08 00:01:51.522 READ DMA
- c8 00 20 b8 ac 84 e0 08 00:01:51.522 READ DMA
- Error 43 occurred at disk power-on lifetime: 5 hours (0 days + 5 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 08 c1 ec 84 e0 Error: UNC 8 sectors at LBA = 0x0084ecc1 = 8711361
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 08 c0 ec 84 e0 08 00:17:56.006 READ DMA
- Error 42 occurred at disk power-on lifetime: 5 hours (0 days + 5 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 08 c1 ec 84 e0 Error: UNC 8 sectors at LBA = 0x0084ecc1 = 8711361
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 08 c0 ec 84 e0 08 00:07:50.375 READ DMA
- ec 00 00 00 00 00 a0 08 00:07:50.347 IDENTIFY DEVICE
- ef 03 46 00 00 00 a0 08 00:07:50.347 SET FEATURES [Set transfer mode]
- SMART Self-test log structure revision number 1
- No self-tests have been logged. [To run self-tests, use: smartctl -t]
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.