Guest User

Untitled

a guest
Mar 9th, 2016
161
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 4.26 KB | None | 0 0
  1. === START OF INFORMATION SECTION ===
  2. Model Family: Samsung based SSDs
  3. Device Model: Samsung SSD 840 PRO Series
  4. Serial Number: S1ATNSAF710194V
  5. LU WWN Device Id: 5 002538 5a028169c
  6. Firmware Version: DXM06B0Q
  7. User Capacity: 256,060,514,304 bytes [256 GB]
  8. Sector Size: 512 bytes logical/physical
  9. Rotation Rate: Solid State Device
  10. Device is: In smartctl database [for details use: -P show]
  11. ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
  12. SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
  13. Local Time is: Wed Mar 9 18:09:22 2016 GMT-3
  14. SMART support is: Available - device has SMART capability.
  15. SMART support is: Enabled
  16.  
  17. === START OF READ SMART DATA SECTION ===
  18. SMART overall-health self-assessment test result: PASSED
  19.  
  20. General SMART Values:
  21. Offline data collection status: (0x00) Offline data collection activity
  22. was never started.
  23. Auto Offline Data Collection: Disabled.
  24. Self-test execution status: ( 0) The previous self-test routine completed
  25. without error or no self-test has ever
  26. been run.
  27. Total time to complete Offline
  28. data collection: (53956) seconds.
  29. Offline data collection
  30. capabilities: (0x53) SMART execute Offline immediate.
  31. Auto Offline data collection on/off support.
  32. Suspend Offline collection upon new
  33. command.
  34. No Offline surface scan supported.
  35. Self-test supported.
  36. No Conveyance Self-test supported.
  37. Selective Self-test supported.
  38. SMART capabilities: (0x0003) Saves SMART data before entering
  39. power-saving mode.
  40. Supports SMART auto save timer.
  41. Error logging capability: (0x01) Error logging supported.
  42. General Purpose Logging supported.
  43. Short self-test routine
  44. recommended polling time: ( 2) minutes.
  45. Extended self-test routine
  46. recommended polling time: ( 20) minutes.
  47. SCT capabilities: (0x003d) SCT Status supported.
  48. SCT Error Recovery Control supported.
  49. SCT Feature Control supported.
  50. SCT Data Table supported.
  51.  
  52. SMART Attributes Data Structure revision number: 1
  53. Vendor Specific SMART Attributes with Thresholds:
  54. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  55. 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
  56. 9 Power_On_Hours 0x0032 097 097 000 Old_age Always - 10302
  57. 12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 630
  58. 177 Wear_Leveling_Count 0x0013 096 096 000 Pre-fail Always - 137
  59. 179 Used_Rsvd_Blk_Cnt_Tot 0x0013 100 100 010 Pre-fail Always - 0
  60. 181 Program_Fail_Cnt_Total 0x0032 100 100 010 Old_age Always - 0
  61. 182 Erase_Fail_Count_Total 0x0032 100 100 010 Old_age Always - 0
  62. 183 Runtime_Bad_Block 0x0013 100 100 010 Pre-fail Always - 0
  63. 187 Uncorrectable_Error_Cnt 0x0032 100 100 000 Old_age Always - 0
  64. 190 Airflow_Temperature_Cel 0x0032 059 041 000 Old_age Always - 41
  65. 195 ECC_Error_Rate 0x001a 200 200 000 Old_age Always - 0
  66. 199 CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0
  67. 235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 578
  68. 241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 11223645741
  69.  
  70. SMART Error Log Version: 1
  71. No Errors Logged
  72.  
  73. SMART Self-test log structure revision number 1
  74. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  75. # 1 Extended offline Completed without error 00% 10301 -
  76.  
  77. SMART Selective self-test log data structure revision number 1
  78. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  79. 1 0 0 Not_testing
  80. 2 0 0 Not_testing
  81. 3 0 0 Not_testing
  82. 4 0 0 Not_testing
  83. 5 0 0 Not_testing
  84. 255 0 65535 Read_scanning was never started
  85. Selective self-test flags (0x0):
  86. After scanning selected spans, do NOT read-scan remainder of disk.
  87. If Selective self-test is pending on power-up, resume after 0 minute delay.