Guest User

Untitled

a guest
Jun 5th, 2014
355
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 5.40 KB | None | 0 0
  1. smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.13.0-28-generic] (local build)
  2. Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Device Model: ST320LT012-9WS14C
  6. Serial Number: W0V1NNE6
  7. LU WWN Device Id: 5 000c50 053a3080e
  8. Firmware Version: 0001SDM1
  9. User Capacity: 320,072,933,376 bytes [320 GB]
  10. Sector Sizes: 512 bytes logical, 4096 bytes physical
  11. Device is: Not in smartctl database [for details use: -P showall]
  12. ATA Version is: 8
  13. ATA Standard is: ATA-8-ACS revision 4
  14. Local Time is: Thu Jun 5 16:15:46 2014 YEKT
  15. SMART support is: Available - device has SMART capability.
  16. SMART support is: Enabled
  17.  
  18. === START OF READ SMART DATA SECTION ===
  19. SMART overall-health self-assessment test result: PASSED
  20.  
  21. General SMART Values:
  22. Offline data collection status: (0x82) Offline data collection activity
  23. was completed without error.
  24. Auto Offline Data Collection: Enabled.
  25. Self-test execution status: ( 0) The previous self-test routine completed
  26. without error or no self-test has ever
  27. been run.
  28. Total time to complete Offline
  29. data collection: ( 0) seconds.
  30. Offline data collection
  31. capabilities: (0x7b) SMART execute Offline immediate.
  32. Auto Offline data collection on/off support.
  33. Suspend Offline collection upon new
  34. command.
  35. Offline surface scan supported.
  36. Self-test supported.
  37. Conveyance Self-test supported.
  38. Selective Self-test supported.
  39. SMART capabilities: (0x0003) Saves SMART data before entering
  40. power-saving mode.
  41. Supports SMART auto save timer.
  42. Error logging capability: (0x01) Error logging supported.
  43. General Purpose Logging supported.
  44. Short self-test routine
  45. recommended polling time: ( 1) minutes.
  46. Extended self-test routine
  47. recommended polling time: ( 88) minutes.
  48. Conveyance self-test routine
  49. recommended polling time: ( 2) minutes.
  50. SCT capabilities: (0x1035) SCT Status supported.
  51. SCT Feature Control supported.
  52. SCT Data Table supported.
  53.  
  54. SMART Attributes Data Structure revision number: 10
  55. Vendor Specific SMART Attributes with Thresholds:
  56. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  57. 1 Raw_Read_Error_Rate 0x000f 117 099 006 Pre-fail Always - 167620680
  58. 3 Spin_Up_Time 0x0003 100 099 000 Pre-fail Always - 0
  59. 4 Start_Stop_Count 0x0032 099 099 020 Old_age Always - 1033
  60. 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0
  61. 7 Seek_Error_Rate 0x000f 072 060 030 Pre-fail Always - 20952668
  62. 9 Power_On_Hours 0x0032 098 098 000 Old_age Always - 232907486529283
  63. 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
  64. 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 477
  65. 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
  66. 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
  67. 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0
  68. 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
  69. 190 Airflow_Temperature_Cel 0x0022 058 052 045 Old_age Always - 42 (Min/Max 35/42)
  70. 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 140
  71. 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 58
  72. 193 Load_Cycle_Count 0x0032 094 094 000 Old_age Always - 12453
  73. 194 Temperature_Celsius 0x0022 042 048 000 Old_age Always - 42 (0 13 0 0)
  74. 196 Reallocated_Event_Count 0x000f 099 099 030 Pre-fail Always - 1679 (17383, 0)
  75. 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
  76. 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
  77. 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
  78. 240 Head_Flying_Hours 0x0000 099 099 000 Old_age Offline - 74659416508047
  79. 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 3072202343
  80. 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 1653264020
  81. 254 Free_Fall_Sensor 0x0032 100 100 000 Old_age Always - 0
  82.  
  83. SMART Error Log Version: 1
  84. No Errors Logged
  85.  
  86. SMART Self-test log structure revision number 1
  87. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  88. # 1 Short offline Completed without error 00% 751 -
  89. # 2 Extended offline Aborted by host 90% 751 -
  90.  
  91. SMART Selective self-test log data structure revision number 1
  92. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  93. 1 0 0 Not_testing
  94. 2 0 0 Not_testing
  95. 3 0 0 Not_testing
  96. 4 0 0 Not_testing
  97. 5 0 0 Not_testing
  98. Selective self-test flags (0x0):
  99. After scanning selected spans, do NOT read-scan remainder of disk.
  100. If Selective self-test is pending on power-up, resume after 0 minute delay.
Advertisement
Add Comment
Please, Sign In to add comment