- smartctl 6.0 2012-10-10 r3643 [x86_64-linux-3.8.2-206.fc18.x86_64] (local build)
- Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: SAMSUNG SpinPoint P120
- Device Model: SAMSUNG SP1613N
- Serial Number: S0CVJ1CP806628
- Firmware Version: VB100-50
- User Capacity: 160.041.885.696 bytes [160 GB]
- Sector Size: 512 bytes logical/physical
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ATA/ATAPI-7 T13/1532D revision 4a
- Local Time is: Sat Mar 16 17:36:21 2013 CET
- ==> WARNING: May need -F samsung3 enabled; see manual for details.
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x02) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 3575) seconds.
- Offline data collection
- capabilities: (0x5b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- No Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: ( 59) minutes.
- SCT capabilities: (0x003f) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0007 253 253 025 Pre-fail Always - 6080
- 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 158
- 5 Reallocated_Sector_Ct 0x0033 253 253 010 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x000f 253 253 051 Pre-fail Always - 0
- 8 Seek_Time_Performance 0x0025 253 253 015 Pre-fail Offline - 0
- 9 Power_On_Hours 0x0032 253 253 000 Old_age Always - 146
- 10 Spin_Retry_Count 0x0033 253 253 051 Pre-fail Always - 0
- 11 Calibration_Retry_Count 0x0012 253 100 000 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 140
- 187 Reported_Uncorrect 0x0032 083 083 000 Old_age Always - 18
- 190 Airflow_Temperature_Cel 0x0022 139 118 000 Old_age Always - 33
- 194 Temperature_Celsius 0x0022 139 118 000 Old_age Always - 33
- 195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 2932769
- 196 Reallocated_Event_Count 0x0032 253 253 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0012 253 100 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0030 253 253 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
- 200 Multi_Zone_Error_Rate 0x000a 100 100 000 Old_age Always - 0
- 201 Soft_Read_Error_Rate 0x000a 253 100 000 Old_age Always - 0
- SMART Error Log Version: 1
- ATA Error Count: 18 (device log contains only the most recent five errors)
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 18 occurred at disk power-on lifetime: 5 hours (0 days + 5 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 01 e5 7f 19 e0 Error: UNC at LBA = 0x00197fe5 = 1671141
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 40 00 01 e5 7f 19 e0 00 00:26:42.313 READ VERIFY SECTOR(S)
- Error 17 occurred at disk power-on lifetime: 5 hours (0 days + 5 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 02 e5 7f 19 e0 Error: UNC at LBA = 0x00197fe5 = 1671141
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 40 00 02 e5 7f 19 e0 00 00:26:40.563 READ VERIFY SECTOR(S)
- 40 00 02 e3 7f 19 e0 00 00:26:40.563 READ VERIFY SECTOR(S)
- Error 16 occurred at disk power-on lifetime: 5 hours (0 days + 5 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 04 e3 7f 19 e0 Error: UNC at LBA = 0x00197fe3 = 1671139
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 40 00 04 e3 7f 19 e0 00 00:26:38.813 READ VERIFY SECTOR(S)
- 40 00 04 df 7f 19 e0 00 00:26:38.813 READ VERIFY SECTOR(S)
- 40 00 08 e7 7f 19 e0 00 00:26:38.813 READ VERIFY SECTOR(S)
- Error 15 occurred at disk power-on lifetime: 5 hours (0 days + 5 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 08 df 7f 19 e0 Error: UNC at LBA = 0x00197fdf = 1671135
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 40 00 08 df 7f 19 e0 00 00:26:37.063 READ VERIFY SECTOR(S)
- 40 00 10 ef 7f 19 e0 00 00:26:37.063 READ VERIFY SECTOR(S)
- Error 14 occurred at disk power-on lifetime: 5 hours (0 days + 5 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 10 df 7f 19 e0 Error: UNC at LBA = 0x00197fdf = 1671135
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 40 00 10 df 7f 19 e0 00 00:26:35.313 READ VERIFY SECTOR(S)
- SMART Self-test log structure revision number 1
- No self-tests have been logged. [To run self-tests, use: smartctl -t]
- SMART Selective self-test log data structure revision number 0
- Note: revision number not 1 implies that no selective self-test has ever been run
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.