  1.  
  2. Adapter #0
  3.  
  4. ==============================================================================
  5. Versions
  6. ================
  7. Product Name : LSI MegaRAID SAS 9260-4i
  8. Serial No : SV25206425
  9. FW Package Build: 12.13.0-0154
  10.  
  11. Mfg. Data
  12. ================
  13. Mfg. Date : 12/23/12
  14. Rework Date : 00/00/00
  15. Revision No : 86B
  16. Battery FRU : N/A
  17.  
  18. Image Versions in Flash:
  19. ================
  20. FW Version : 2.130.383-2315
  21. BIOS Version : 3.27.00_4.12.05.00_0x05270000
  22. Preboot CLI Version: 04.04-020:#%00009
  23. WebBIOS Version : 6.0-51-e_47-Rel
  24. NVDATA Version : 2.09.03-0045
  25. Boot Block Version : 2.02.00.00-0000
  26. BOOT Version : 09.250.01.219
  27.  
  28. Pending Images in Flash
  29. ================
  30. None
  31.  
  32. PCI Info
  33. ================
  34. Controller Id : 0000
  35. Vendor Id : 1000
  36. Device Id : 0079
  37. SubVendorId : 1000
  38. SubDeviceId : 9260
  39.  
  40. Host Interface : PCIE
  41.  
  42. ChipRevision : B4
  43.  
  44. Link Speed : 0
  45. Number of Frontend Port: 0
  46. Device Interface : PCIE
  47.  
  48. Number of Backend Port: 4
  49. Port : Address
  50. 0 4433221102000000
  51. 1 4433221103000000
  52. 2 0000000000000000
  53. 3 0000000000000000
  54.  
  55. HW Configuration
  56. ================
  57. SAS Address : 500605b005b4be90
  58. BBU : Absent
  59. Alarm : Present
  60. NVRAM : Present
  61. Serial Debugger : Present
  62. Memory : Present
  63. Flash : Present
  64. Memory Size : 512MB
  65. TPM : Absent
  66. On board Expander: Absent
  67. Upgrade Key : Absent
  68. Temperature sensor for ROC : Absent
  69. Temperature sensor for controller : Absent
  70.  
  71.  
  72. Settings
  73. ================
  74. Current Time : 17:48:25 3/23, 2013
  75. Predictive Fail Poll Interval : 300sec
  76. Interrupt Throttle Active Count : 16
  77. Interrupt Throttle Completion : 50us
  78. Rebuild Rate : 30%
  79. PR Rate : 30%
  80. BGI Rate : 30%
  81. Check Consistency Rate : 30%
  82. Reconstruction Rate : 30%
  83. Cache Flush Interval : 4s
  84. Max Drives to Spinup at One Time : 4
  85. Delay Among Spinup Groups : 2s
  86. Physical Drive Coercion Mode : Disabled
  87. Cluster Mode : Disabled
  88. Alarm : Disabled
  89. Auto Rebuild : Enabled
  90. Battery Warning : Disabled
  91. Ecc Bucket Size : 15
  92. Ecc Bucket Leak Rate : 1440 Minutes
  93. Restore HotSpare on Insertion : Disabled
  94. Expose Enclosure Devices : Enabled
  95. Maintain PD Fail History : Enabled
  96. Host Request Reordering : Enabled
  97. Auto Detect BackPlane Enabled : SGPIO/i2c SEP
  98. Load Balance Mode : Auto
  99. Use FDE Only : No
  100. Security Key Assigned : No
  101. Security Key Failed : No
  102. Security Key Not Backedup : No
  103. Default LD PowerSave Policy : Controller Defined
  104. Maximum number of direct attached drives to spin up in 1 min : 120
  105. Auto Enhanced Import : Yes
  106. Any Offline VD Cache Preserved : No
  107. Allow Boot with Preserved Cache : No
  108. Disable Online Controller Reset : No
  109. PFK in NVRAM : No
  110. Use disk activity for locate : No
  111. POST delay : 90 seconds
  112. BIOS Error Handling : Pause on Errors
  113. Current Boot Mode :Normal
  114. Capabilities
  115. ================
  116. RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span
  117. Supported Drives : SAS, SATA
  118.  
  119. Allowed Mixing:
  120.  
  121. Mix in Enclosure Allowed
  122. Mix of SAS/SATA of HDD type in VD Allowed
  123. Mix of SAS/SATA of SSD type in VD Allowed
  124. Mix of SSD/HDD in VD Allowed
  125.  
  126. Status
  127. ================
  128. ECC Bucket Count : 0
  129.  
  130. Limitations
  131. ================
  132. Max Arms Per VD : 32
  133. Max Spans Per VD : 8
  134. Max Arrays : 128
  135. Max Number of VDs : 64
  136. Max Parallel Commands : 1008
  137. Max SGE Count : 80
  138. Max Data Transfer Size : 8192 sectors
  139. Max Strips PerIO : 42
  140. Max LD per array : 16
  141. Min Strip Size : 8 KB
  142. Max Strip Size : 1.0 MB
  143. Max Configurable CacheCade Size: 0 GB
  144. Current Size of CacheCade : 0 GB
  145. Current Size of FW Cache : 346 MB
  146.  
  147. Device Present
  148. ================
  149. Virtual Drives : 1
  150. Degraded : 0
  151. Offline : 0
  152. Physical Devices : 3
  153. Disks : 2
  154. Critical Disks : 0
  155. Failed Disks : 0
  156.  
  157. Supported Adapter Operations
  158. ================
  159. Rebuild Rate : Yes
  160. CC Rate : Yes
  161. BGI Rate : Yes
  162. Reconstruct Rate : Yes
  163. Patrol Read Rate : Yes
  164. Alarm Control : Yes
  165. Cluster Support : No
  166. BBU : Yes
  167. Spanning : Yes
  168. Dedicated Hot Spare : Yes
  169. Revertible Hot Spares : Yes
  170. Foreign Config Import : Yes
  171. Self Diagnostic : Yes
  172. Allow Mixed Redundancy on Array : No
  173. Global Hot Spares : Yes
  174. Deny SCSI Passthrough : No
  175. Deny SMP Passthrough : No
  176. Deny STP Passthrough : No
  177. Support Security : No
  178. Snapshot Enabled : No
  179. Support the OCE without adding drives : Yes
  180. Support PFK : Yes
  181. Support PI : No
  182. Support Boot Time PFK Change : No
  183. Disable Online PFK Change : No
  184. PFK TrailTime Remaining : 0 days 0 hours
  185. Support Shield State : No
  186. Block SSD Write Disk Cache Change: No
  187. Support Online FW Update : Yes
  188.  
  189. Supported VD Operations
  190. ================
  191. Read Policy : Yes
  192. Write Policy : Yes
  193. IO Policy : Yes
  194. Access Policy : Yes
  195. Disk Cache Policy : Yes
  196. Reconstruction : Yes
  197. Deny Locate : No
  198. Deny CC : No
  199. Allow Ctrl Encryption: No
  200. Enable LDBBM : Yes
  201. Support Breakmirror : No
  202. Power Savings : No
  203.  
  204. Supported PD Operations
  205. ================
  206. Force Online : Yes
  207. Force Offline : Yes
  208. Force Rebuild : Yes
  209. Deny Force Failed : No
  210. Deny Force Good/Bad : No
  211. Deny Missing Replace : No
  212. Deny Clear : No
  213. Deny Locate : No
  214. Support Temperature : Yes
  215. Disable Copyback : No
  216. Enable JBOD : No
  217. Enable Copyback on SMART : No
  218. Enable Copyback to SSD on SMART Error : Yes
  219. Enable SSD Patrol Read : No
  220. PR Correct Unconfigured Areas : Yes
  221. Enable Spin Down of UnConfigured Drives : Yes
  222. Disable Spin Down of hot spares : No
  223. Spin Down time : 30
  224. T10 Power State : No
  225. Error Counters
  226. ================
  227. Memory Correctable Errors : 0
  228. Memory Uncorrectable Errors : 0
  229.  
  230. Cluster Information
  231. ================
  232. Cluster Permitted : No
  233. Cluster Active : No
  234.  
  235. Default Settings
  236. ================
  237. Phy Polarity : 0
  238. Phy PolaritySplit : 0
  239. Background Rate : 30
  240. Strip Size : 256kB
  241. Flush Time : 4 seconds
  242. Write Policy : WB
  243. Read Policy : RA
  244. Cache When BBU Bad : Disabled
  245. Cached IO : No
  246. SMART Mode : Mode 6
  247. Alarm Disable : Yes
  248. Coercion Mode : None
  249. ZCR Config : Unknown
  250. Dirty LED Shows Drive Activity : No
  251. BIOS Continue on Error : 3
  252. Spin Down Mode : None
  253. Allowed Device Type : SAS/SATA Mix
  254. Allow Mix in Enclosure : Yes
  255. Allow HDD SAS/SATA Mix in VD : Yes
  256. Allow SSD SAS/SATA Mix in VD : Yes
  257. Allow HDD/SSD Mix in VD : Yes
  258. Allow SATA in Cluster : No
  259. Max Chained Enclosures : 16
  260. Disable Ctrl-R : Yes
  261. Enable Web BIOS : Yes
  262. Direct PD Mapping : No
  263. BIOS Enumerate VDs : Yes
  264. Restore Hot Spare on Insertion : No
  265. Expose Enclosure Devices : Yes
  266. Maintain PD Fail History : Yes
  267. Disable Puncturing : No
  268. Zero Based Enclosure Enumeration : No
  269. PreBoot CLI Enabled : Yes
  270. LED Show Drive Activity : Yes
  271. Cluster Disable : Yes
  272. SAS Disable : No
  273. Auto Detect BackPlane Enable : SGPIO/i2c SEP
  274. Use FDE Only : No
  275. Enable Led Header : Yes
  276. Delay during POST : 0
  277. EnableCrashDump : No
  278. Disable Online Controller Reset : No
  279. EnableLDBBM : Yes
  280. Un-Certified Hard Disk Drives : Allow
  281. Treat Single span R1E as R10 : No
  282. Max LD per array : 16
  283. Power Saving option : Don't Auto spin down Configured Drives
  284. Max power savings option is not allowed for LDs. Only T10 power conditions are to be used.
  285. Default spin down time in minutes: 30
  286. Enable JBOD : No
  287. TTY Log In Flash : No
  288. Auto Enhanced Import : Yes
  289. BreakMirror RAID Support : Yes
  290. Disable Join Mirror : No
  291. Enable Shield State : No
  292. Time taken to detect CME : 60s
  293.  
  294. Exit Code: 0x00