  1. smartctl 5.42 2011-10-20 r3458 [i386-pc-solaris2.11] (local build)
  2. Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family:     Western Digital Caviar Green
  6. Device Model:     WDC WD10EADS-65L5B1
  7. Firmware Version: 01.01A01
  8. User Capacity:    1,000,204,886,016 bytes [1.00 TB]
  9. Sector Size:      512 bytes logical/physical
  10. Device is:        In smartctl database [for details use: -P show]
  11. ATA Version is:   8
  12. ATA Standard is:  Exact ATA specification draft version not indicated
  13. Local Time is:    Sat May 19 17:58:09 2012 PDT
  14. SMART support is: Available - device has SMART capability.
  15. SMART support is: Enabled
  16.  
  17. === START OF READ SMART DATA SECTION ===
  18. SMART overall-health self-assessment test result: PASSED
  19.  
  20. General SMART Values:
  21. Offline data collection status:  (0x02) Offline data collection activity
  22.                                         was completed without error.
  23.                                         Auto Offline Data Collection: Disabled.
  24. Self-test execution status:      (   0) The previous self-test routine completed
  25.                                         without error or no self-test has ever
  26.                                         been run.
  27. Total time to complete Offline
  28. data collection:                (24000) seconds.
  29. Offline data collection
  30. capabilities:                    (0x7b) SMART execute Offline immediate.
  31.                                         Auto Offline data collection on/off support.
  32.                                         Suspend Offline collection upon new
  33.                                         command.
  34.                                         Offline surface scan supported.
  35.                                         Self-test supported.
  36.                                         Conveyance Self-test supported.
  37.                                         Selective Self-test supported.
  38. SMART capabilities:            (0x0003) Saves SMART data before entering
  39.                                         power-saving mode.
  40.                                         Supports SMART auto save timer.
  41. Error logging capability:        (0x01) Error logging supported.
  42.                                         General Purpose Logging supported.
  43. Short self-test routine
  44. recommended polling time:        (   2) minutes.
  45. Extended self-test routine
  46. recommended polling time:        ( 255) minutes.
  47. Conveyance self-test routine
  48. recommended polling time:        (   5) minutes.
  49. SCT capabilities:              (0x303f) SCT Status supported.
  50.                                         SCT Error Recovery Control supported.
  51.                                         SCT Feature Control supported.
  52.                                         SCT Data Table supported.
  53.  
  54. SMART Attributes Data Structure revision number: 16
  55. Vendor Specific SMART Attributes with Thresholds:
  56. ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  57.   1 Raw_Read_Error_Rate     0x002f   200   200   051    Pre-fail  Always       -       0
  58.   3 Spin_Up_Time            0x0027   183   160   021    Pre-fail  Always       -       5841
  59.   4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       -       88
  60.   5 Reallocated_Sector_Ct   0x0033   200   200   140    Pre-fail  Always       -       0
  61.   7 Seek_Error_Rate         0x002e   100   253   000    Old_age   Always       -       0
  62.   9 Power_On_Hours          0x0032   072   072   000    Old_age   Always       -       20598
  63.  10 Spin_Retry_Count        0x0032   100   253   000    Old_age   Always       -       0
  64.  11 Calibration_Retry_Count 0x0032   100   253   000    Old_age   Always       -       0
  65.  12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       81
  66. 192 Power-Off_Retract_Count 0x0032   200   200   000    Old_age   Always       -       26
  67. 193 Load_Cycle_Count        0x0032   200   200   000    Old_age   Always       -       88
  68. 194 Temperature_Celsius     0x0022   117   106   000    Old_age   Always       -       33
  69. 196 Reallocated_Event_Count 0x0032   200   200   000    Old_age   Always       -       0
  70. 197 Current_Pending_Sector  0x0032   200   200   000    Old_age   Always       -       0
  71. 198 Offline_Uncorrectable   0x0030   200   200   000    Old_age   Offline      -       1
  72. 199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age   Always       -       0
  73. 200 Multi_Zone_Error_Rate   0x0008   200   200   000    Old_age   Offline      -       0
  74.  
  75. SMART Error Log Version: 1
  76. ATA Error Count: 1
  77.         CR = Command Register [HEX]
  78.         FR = Features Register [HEX]
  79.         SC = Sector Count Register [HEX]
  80.         SN = Sector Number Register [HEX]
  81.         CL = Cylinder Low Register [HEX]
  82.         CH = Cylinder High Register [HEX]
  83.         DH = Device/Head Register [HEX]
  84.         DC = Device Command Register [HEX]
  85.         ER = Error register [HEX]
  86.         ST = Status register [HEX]
  87. Powered_Up_Time is measured from power on, and printed as
  88. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  89. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  90.  
  91. Error 1 occurred at disk power-on lifetime: 19600 hours (816 days + 16 hours)
  92.   When the command that caused the error occurred, the device was active or idle.
  93.  
  94.   After command completion occurred, registers were:
  95.   ER ST SC SN CL CH DH
  96.   -- -- -- -- -- -- --
  97.   04 53 10 00 00 00 00  Error: ABRT
  98.  
  99.   Commands leading to the command that caused the error were:
  100.   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  101.   -- -- -- -- -- -- -- --  ----------------  --------------------
  102.   b0 d6 01 e0 4f c2 00 00      00:20:29.444  SMART WRITE LOG
  103.  
  104. SMART Self-test log structure revision number 1
  105. Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
  106. # 1  Extended offline    Completed without error       00%     20584         -
  107. # 2  Short offline       Completed without error       00%     20580         -
  108. # 3  Conveyance offline  Completed without error       00%     20580         -
  109. # 4  Extended offline    Completed without error       00%     20579         -
  110. # 5  Short offline       Completed without error       00%     20574         -
  111. # 6  Short offline       Aborted by host               80%     20574         -
  112. # 7  Short offline       Aborted by host               80%     20574         -
  113. # 8  Short offline       Aborted by host               70%     20574         -
  114. # 9  Short offline       Completed: read failure       90%     20574         59897756
  115. #10  Extended offline    Completed: read failure       90%     20415         59897756
  116. #11  Conveyance offline  Completed: read failure       90%     20414         59897756
  117. #12  Short offline       Completed: read failure       90%     20414         59897756
  118. #13  Extended offline    Completed: read failure       90%     20407         59897756
  119. #14  Short offline       Completed: read failure       90%     20407         59897756
  120. #15  Conveyance offline  Completed: read failure       90%     20404         59897756
  121. #16  Short offline       Completed without error       00%         1         -
  122. #17  Short offline       Completed without error       00%         0         -
  123. 7 of 7 failed self-tests are outdated by newer successful extended offline self-test # 1
  124.  
  125. SMART Selective self-test log data structure revision number 1
  126.  SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
  127.     1        0        0  Not_testing
  128.     2        0        0  Not_testing
  129.     3        0        0  Not_testing
  130.     4        0        0  Not_testing
  131.     5        0        0  Not_testing
  132. Selective self-test flags (0x0):
  133.   After scanning selected spans, do NOT read-scan remainder of disk.
  134. If Selective self-test is pending on power-up, resume after 0 minute delay.
clone this paste RAW Paste Data