Advertisement
Guest User

Untitled

a guest
May 19th, 2012
38
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 6.98 KB | None | 0 0
  1. smartctl 5.42 2011-10-20 r3458 [i386-pc-solaris2.11] (local build)
  2. Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family: Western Digital Caviar Green
  6. Device Model: WDC WD10EADS-65L5B1
  7. Firmware Version: 01.01A01
  8. User Capacity: 1,000,204,886,016 bytes [1.00 TB]
  9. Sector Size: 512 bytes logical/physical
  10. Device is: In smartctl database [for details use: -P show]
  11. ATA Version is: 8
  12. ATA Standard is: Exact ATA specification draft version not indicated
  13. Local Time is: Sat May 19 17:58:09 2012 PDT
  14. SMART support is: Available - device has SMART capability.
  15. SMART support is: Enabled
  16.  
  17. === START OF READ SMART DATA SECTION ===
  18. SMART overall-health self-assessment test result: PASSED
  19.  
  20. General SMART Values:
  21. Offline data collection status: (0x02) Offline data collection activity
  22. was completed without error.
  23. Auto Offline Data Collection: Disabled.
  24. Self-test execution status: ( 0) The previous self-test routine completed
  25. without error or no self-test has ever
  26. been run.
  27. Total time to complete Offline
  28. data collection: (24000) seconds.
  29. Offline data collection
  30. capabilities: (0x7b) SMART execute Offline immediate.
  31. Auto Offline data collection on/off support.
  32. Suspend Offline collection upon new
  33. command.
  34. Offline surface scan supported.
  35. Self-test supported.
  36. Conveyance Self-test supported.
  37. Selective Self-test supported.
  38. SMART capabilities: (0x0003) Saves SMART data before entering
  39. power-saving mode.
  40. Supports SMART auto save timer.
  41. Error logging capability: (0x01) Error logging supported.
  42. General Purpose Logging supported.
  43. Short self-test routine
  44. recommended polling time: ( 2) minutes.
  45. Extended self-test routine
  46. recommended polling time: ( 255) minutes.
  47. Conveyance self-test routine
  48. recommended polling time: ( 5) minutes.
  49. SCT capabilities: (0x303f) SCT Status supported.
  50. SCT Error Recovery Control supported.
  51. SCT Feature Control supported.
  52. SCT Data Table supported.
  53.  
  54. SMART Attributes Data Structure revision number: 16
  55. Vendor Specific SMART Attributes with Thresholds:
  56. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  57. 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
  58. 3 Spin_Up_Time 0x0027 183 160 021 Pre-fail Always - 5841
  59. 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 88
  60. 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
  61. 7 Seek_Error_Rate 0x002e 100 253 000 Old_age Always - 0
  62. 9 Power_On_Hours 0x0032 072 072 000 Old_age Always - 20598
  63. 10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always - 0
  64. 11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0
  65. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 81
  66. 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 26
  67. 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 88
  68. 194 Temperature_Celsius 0x0022 117 106 000 Old_age Always - 33
  69. 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
  70. 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
  71. 198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 1
  72. 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
  73. 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0
  74.  
  75. SMART Error Log Version: 1
  76. ATA Error Count: 1
  77. CR = Command Register [HEX]
  78. FR = Features Register [HEX]
  79. SC = Sector Count Register [HEX]
  80. SN = Sector Number Register [HEX]
  81. CL = Cylinder Low Register [HEX]
  82. CH = Cylinder High Register [HEX]
  83. DH = Device/Head Register [HEX]
  84. DC = Device Command Register [HEX]
  85. ER = Error register [HEX]
  86. ST = Status register [HEX]
  87. Powered_Up_Time is measured from power on, and printed as
  88. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  89. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  90.  
  91. Error 1 occurred at disk power-on lifetime: 19600 hours (816 days + 16 hours)
  92. When the command that caused the error occurred, the device was active or idle.
  93.  
  94. After command completion occurred, registers were:
  95. ER ST SC SN CL CH DH
  96. -- -- -- -- -- -- --
  97. 04 53 10 00 00 00 00 Error: ABRT
  98.  
  99. Commands leading to the command that caused the error were:
  100. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  101. -- -- -- -- -- -- -- -- ---------------- --------------------
  102. b0 d6 01 e0 4f c2 00 00 00:20:29.444 SMART WRITE LOG
  103.  
  104. SMART Self-test log structure revision number 1
  105. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  106. # 1 Extended offline Completed without error 00% 20584 -
  107. # 2 Short offline Completed without error 00% 20580 -
  108. # 3 Conveyance offline Completed without error 00% 20580 -
  109. # 4 Extended offline Completed without error 00% 20579 -
  110. # 5 Short offline Completed without error 00% 20574 -
  111. # 6 Short offline Aborted by host 80% 20574 -
  112. # 7 Short offline Aborted by host 80% 20574 -
  113. # 8 Short offline Aborted by host 70% 20574 -
  114. # 9 Short offline Completed: read failure 90% 20574 59897756
  115. #10 Extended offline Completed: read failure 90% 20415 59897756
  116. #11 Conveyance offline Completed: read failure 90% 20414 59897756
  117. #12 Short offline Completed: read failure 90% 20414 59897756
  118. #13 Extended offline Completed: read failure 90% 20407 59897756
  119. #14 Short offline Completed: read failure 90% 20407 59897756
  120. #15 Conveyance offline Completed: read failure 90% 20404 59897756
  121. #16 Short offline Completed without error 00% 1 -
  122. #17 Short offline Completed without error 00% 0 -
  123. 7 of 7 failed self-tests are outdated by newer successful extended offline self-test # 1
  124.  
  125. SMART Selective self-test log data structure revision number 1
  126. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  127. 1 0 0 Not_testing
  128. 2 0 0 Not_testing
  129. 3 0 0 Not_testing
  130. 4 0 0 Not_testing
  131. 5 0 0 Not_testing
  132. Selective self-test flags (0x0):
  133. After scanning selected spans, do NOT read-scan remainder of disk.
  134. If Selective self-test is pending on power-up, resume after 0 minute delay.
Advertisement