- Status of drive /dev/sda
- Location SATA eszköz A Drive size 2.79 TB
- Make and model ATA WDC WD30EFRX-68E Supports SMART? Igen
- SMART enabled? Igen Errors logged 5 errors detected
- Passed drive check? Igen Model family Western Digital Red
- Make and model WDC WD30EFRX-68EUZN0 Serial number WD-WCC4N1PV2XKH
- Capacity 3,000,592,982,016 bytes [3.00 TB]
- Additional SMART attributes
- Offline data collection status Offline data collection activity was completed without error.
- Auto Offline Data Collection: Enabled.
- Self-test execution status Self-test routine in progress...
- 90% of test remaining.
- Total time to complete Offline data collection 39540 seconds.
- Offline data collection capabilities SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities Saves SMART data before entering power-saving mode.
- Supports SMART auto save timer.
- Error logging capability Error logging supported.
- General Purpose Logging supported.
- Short self-test routine recommended polling time 2 minutes.
- Extended self-test routine recommended polling time 397 minutes.
- Conveyance self-test routine recommended polling time 5 minutes.
- SCT capabilities SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- Raw Read Error Rate 0 (Normalized: 200)
- Spin Up Time 4508 (Normalized: 209)
- Start Stop Count 993 (Normalized: 100)
- Reallocated Sector Ct 0 (Normalized: 200)
- Seek Error Rate 0 (Normalized: 200)
- Power On Hours 6462 (Normalized: 092)
- Spin Retry Count 0 (Normalized: 100)
- Calibration Retry Count 0 (Normalized: 100)
- Power Cycle Count 74 (Normalized: 100)
- Power-Off Retract Count 46 (Normalized: 200)
- Load Cycle Count 1053 (Normalized: 200)
- Temperature Celsius 31 (Normalized: 119)
- Reallocated Event Count 0 (Normalized: 200)
- Current Pending Sector 0 (Normalized: 200)
- Offline Uncorrectable 0 (Normalized: 200)
- Multi Zone Error Rate 0 (Normalized: 200)
- Full SMART status report
- smartctl 6.5 2016-01-24 r4214 [x86_64-linux-4.4.0-59-generic] (local build)
- Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Western Digital Red
- Device Model: WDC WD30EFRX-68EUZN0
- Serial Number: WD-WCC4N1PV2XKH
- LU WWN Device Id: 5 0014ee 261c33cb1
- Firmware Version: 82.00A82
- User Capacity: 3,000,592,982,016 bytes [3.00 TB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 5400 rpm
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ACS-2 (minor revision not indicated)
- SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Thu Jan 19 22:59:18 2017 GMT
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x82) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 249) Self-test routine in progress...
- 90% of test remaining.
- Total time to complete Offline
- data collection: (39540) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 397) minutes.
- Conveyance self-test routine
- recommended polling time: ( 5) minutes.
- SCT capabilities: (0x703d) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0027 209 174 021 Pre-fail Always - 4508
- 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 993
- 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
- 9 Power_On_Hours 0x0032 092 092 000 Old_age Always - 6462
- 10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0
- 11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 74
- 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 46
- 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 1053
- 194 Temperature_Celsius 0x0022 119 109 000 Old_age Always - 31
- 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
- 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0
- SMART Error Log Version: 1
- ATA Error Count: 5
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 5 occurred at disk power-on lifetime: 5282 hours (220 days + 2 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 04 51 01 00 00 00 00 Error: ABRT
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- b0 d5 01 e1 4f c2 00 08 18d+02:43:13.697 SMART READ LOG
- b0 d6 01 e0 4f c2 00 08 18d+02:43:13.697 SMART WRITE LOG
- b0 d6 01 e0 4f c2 00 08 18d+02:43:13.696 SMART WRITE LOG
- b0 d6 01 e0 4f c2 00 08 18d+02:43:13.696 SMART WRITE LOG
- b0 d5 01 e0 4f c2 00 08 18d+02:43:13.695 SMART READ LOG
- Error 4 occurred at disk power-on lifetime: 4833 hours (201 days + 9 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 04 51 01 00 00 00 00 Error: ABRT
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- b0 d5 01 e1 4f c2 00 08 00:08:56.482 SMART READ LOG
- b0 d5 01 00 4f c2 00 08 00:08:56.482 SMART READ LOG
- b0 d6 01 e0 4f c2 00 08 00:08:56.482 SMART WRITE LOG
- b0 d6 01 e0 4f c2 00 08 00:08:56.481 SMART WRITE LOG
- b0 d5 01 e0 4f c2 00 08 00:08:56.481 SMART READ LOG
- Error 3 occurred at disk power-on lifetime: 4832 hours (201 days + 8 hours)
- When the command that caused the error occurred, the device was doing SMART Offline or Self-test.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 04 51 01 00 00 00 00 Error: ABRT
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- b0 d5 01 e1 4f c2 00 08 01:37:43.184 SMART READ LOG
- b0 d5 01 e1 4f c2 00 08 01:37:43.184 SMART READ LOG
- b0 d5 01 e0 4f c2 00 08 01:37:43.184 SMART READ LOG
- b0 d6 01 e0 4f c2 00 08 01:37:43.183 SMART WRITE LOG
- b0 d6 01 e0 4f c2 00 08 01:37:43.182 SMART WRITE LOG
- Error 2 occurred at disk power-on lifetime: 4831 hours (201 days + 7 hours)
- When the command that caused the error occurred, the device was doing SMART Offline or Self-test.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 04 51 01 00 00 00 00 Error: ABRT
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- b0 d5 01 e1 4f c2 00 08 01:02:10.704 SMART READ LOG
- b0 d5 01 e1 4f c2 00 08 01:02:10.697 SMART READ LOG
- b0 d5 01 e1 4f c2 00 08 01:02:10.697 SMART READ LOG
- Error 1 occurred at disk power-on lifetime: 4831 hours (201 days + 7 hours)
- When the command that caused the error occurred, the device was doing SMART Offline or Self-test.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 04 51 01 00 00 00 00 Error: ABRT
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- b0 d5 01 e1 4f c2 00 08 01:02:10.697 SMART READ LOG
- b0 d5 01 e1 4f c2 00 08 01:02:10.697 SMART READ LOG
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed without error 00% 6175 -
- # 2 Short offline Completed without error 00% 5441 -
- # 3 Short offline Completed without error 00% 5282 -
- # 4 Extended offline Interrupted (host reset) 70% 4823 -
- # 5 Extended offline Completed without error 00% 4816 -
- # 6 Extended offline Completed without error 00% 4781 -
- # 7 Extended offline Completed without error 00% 4612 -
- # 8 Extended offline Completed without error 00% 4444 -
- # 9 Extended offline Completed without error 00% 4276 -
- #10 Extended offline Completed without error 00% 4108 -
- #11 Extended offline Completed without error 00% 3941 -
- #12 Extended offline Completed without error 00% 3773 -
- #13 Extended offline Completed without error 00% 3625 -
- #14 Extended offline Completed without error 00% 3458 -
- #15 Extended offline Aborted by host 60% 3373 -
- #16 Extended offline Completed without error 00% 3102 -
- #17 Extended offline Completed without error 00% 3086 -
- #18 Extended offline Completed without error 00% 2383 -
- #19 Extended offline Completed without error 00% 2255 -
- #20 Extended offline Completed without error 00% 2217 -
- #21 Extended offline Completed without error 00% 1641 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing