  1. smartctl 6.2 2013-07-26 r3841 [FreeBSD 9.2-RELEASE-p12 amd64] (local build)
  2. Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Device Model: WDC WD40EFRX-68WT0N0
  6. Serial Number: WD-WCCXXXXXXXXXX
  7. LU WWN Device Id: 5 0014ee 2b5149a98
  8. Firmware Version: 80.00A80
  9. User Capacity: 4,000,787,030,016 bytes [4.00 TB]
  10. Sector Sizes: 512 bytes logical, 4096 bytes physical
  11. Rotation Rate: 5400 rpm
  12. Device is: Not in smartctl database [for details use: -P showall]
  13. ATA Version is: ACS-2 (minor revision not indicated)
  14. SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
  15. Local Time is: Fri Jan 9 23:53:40 2015 IST
  16. SMART support is: Available - device has SMART capability.
  17. SMART support is: Enabled
  18.  
  19. === START OF READ SMART DATA SECTION ===
  20. SMART overall-health self-assessment test result: PASSED
  21.  
  22. General SMART Values:
  23. Offline data collection status: (0x80) Offline data collection activity
  24. was never started.
  25. Auto Offline Data Collection: Enabled.
  26. Self-test execution status: ( 0) The previous self-test routine completed
  27. without error or no self-test has ever
  28. been run.
  29. Total time to complete Offline
  30. data collection: (52560) seconds.
  31. Offline data collection
  32. capabilities: (0x7b) SMART execute Offline immediate.
  33. Auto Offline data collection on/off support.
  34. Suspend Offline collection upon new
  35. command.
  36. Offline surface scan supported.
  37. Self-test supported.
  38. Conveyance Self-test supported.
  39. Selective Self-test supported.
  40. SMART capabilities: (0x0003) Saves SMART data before entering
  41. power-saving mode.
  42. Supports SMART auto save timer.
  43. Error logging capability: (0x01) Error logging supported.
  44. General Purpose Logging supported.
  45. Short self-test routine
  46. recommended polling time: ( 2) minutes.
  47. Extended self-test routine
  48. recommended polling time: ( 526) minutes.
  49. Conveyance self-test routine
  50. recommended polling time: ( 5) minutes.
  51. SCT capabilities: (0x703d) SCT Status supported.
  52. SCT Error Recovery Control supported.
  53. SCT Feature Control supported.
  54. SCT Data Table supported.
  55.  
  56. SMART Attributes Data Structure revision number: 16
  57. Vendor Specific SMART Attributes with Thresholds:
  58. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  59. 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 36
  60. 3 Spin_Up_Time 0x0027 179 178 021 Pre-fail Always - 8016
  61. 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 16
  62. 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
  63. 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
  64. 9 Power_On_Hours 0x0032 097 097 000 Old_age Always - 2632
  65. 10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always - 0
  66. 11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0
  67. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 16
  68. 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 6
  69. 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 38
  70. 194 Temperature_Celsius 0x0022 119 110 000 Old_age Always - 33
  71. 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
  72. 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 6
  73. 198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0
  74. 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
  75. 200 Multi_Zone_Error_Rate 0x0008 200 198 000 Old_age Offline - 196
  76.  
  77. SMART Error Log Version: 1
  78. No Errors Logged
  79.  
  80. SMART Self-test log structure revision number 1
  81. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  82. # 1 Short offline Completed without error 00% 2609 -
  83. # 2 Extended offline Completed: read failure 90% 2585 426023488
  84. # 3 Short offline Completed without error 00% 2561 -
  85. # 4 Short offline Completed without error 00% 2537 -
  86. # 5 Short offline Completed without error 00% 2489 -
  87. # 6 Short offline Completed without error 00% 2465 -
  88. # 7 Short offline Completed without error 00% 2441 -
  89. # 8 Extended offline Completed without error 00% 2427 -
  90. # 9 Short offline Completed without error 00% 2393 -
  91. #10 Short offline Completed without error 00% 2369 -
  92. #11 Short offline Completed without error 00% 2321 -
  93. #12 Short offline Completed without error 00% 2297 -
  94. #13 Short offline Completed without error 00% 2273 -
  95. #14 Extended offline Completed without error 00% 2259 -
  96. #15 Short offline Completed without error 00% 2225 -
  97. #16 Short offline Completed without error 00% 2201 -
  98. #17 Short offline Completed without error 00% 2153 -
  99. #18 Short offline Completed without error 00% 2129 -
  100. #19 Short offline Completed without error 00% 2105 -
  101. #20 Extended offline Completed without error 00% 2091 -
  102. #21 Short offline Completed without error 00% 2057 -
  103.  
  104. SMART Selective self-test log data structure revision number 1
  105. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  106. 1 0 0 Not_testing
  107. 2 0 0 Not_testing
  108. 3 0 0 Not_testing
  109. 4 0 0 Not_testing
  110. 5 0 0 Not_testing
  111. Selective self-test flags (0x0):
  112. After scanning selected spans, do NOT read-scan remainder of disk.
  113. If Selective self-test is pending on power-up, resume after 0 minute delay.