- [root@localhost Téléchargements]# smartctl -a /dev/sda
- smartctl 5.40 2010-10-16 r3189 [x86_64-redhat-linux-gnu] (local build)
- Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
- === START OF INFORMATION SECTION ===
- Model Family: Hitachi Travelstar 5K250
- Device Model: Hitachi HTS542525K9SA00
- Serial Number: 080528BB3F00WDDYVA4F
- Firmware Version: BBFOC32P
- User Capacity: 250 059 350 016 bytes
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: 8
- ATA Standard is: ATA-8-ACS revision 3f
- Local Time is: Mon Nov 29 21:02:48 2010 CET
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 645) seconds.
- Offline data collection
- capabilities: (0x51) SMART execute Offline immediate.
- No Auto Offline data collection support.
- Suspend Offline collection upon new
- command.
- No Offline surface scan supported.
- Self-test supported.
- No Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 107) minutes.
- SCT capabilities: (0x003d) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 100 100 062 Pre-fail Always - 0
- 2 Throughput_Performance 0x0005 100 100 040 Pre-fail Offline - 0
- 3 Spin_Up_Time 0x0023 205 100 033 Pre-fail Always - 1
- 4 Start_Stop_Count 0x0032 099 099 000 Old_age Always - 2092
- 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 8 (0, 3)
- 7 Seek_Error_Rate 0x000f 100 100 067 Pre-fail Always - 0
- 8 Seek_Time_Performance 0x0005 100 100 040 Pre-fail Offline - 0
- 9 Power_On_Hours 0x0032 086 086 000 Old_age Always - 6437
- 10 Spin_Retry_Count 0x0033 100 100 060 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 2068
- 184 End-to-End_Error 0x0033 100 100 099 Pre-fail Always - 0
- 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 1703936
- 188 Command_Timeout 0x0032 096 001 000 Old_age Always - 2091
- 190 Airflow_Temperature_Cel 0x0022 072 052 000 Old_age Always - 28 (Min/Max 17/28)
- 191 G-Sense_Error_Rate 0x000a 099 086 000 Old_age Always - 3
- 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 11600049
- 193 Load_Cycle_Count 0x0032 097 097 000 Old_age Always - 30673
- 194 Temperature_Celsius 0x0022 196 100 000 Old_age Always - 28 (Min/Max 13/48)
- 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 2
- 197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x002a 200 200 000 Old_age Always - 0
- 223 Load_Retry_Count 0x002a 100 100 000 Old_age Always - 0
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Extended offline Completed without error 00% 6432 -
- # 2 Short offline Completed without error 00% 6413 -
- # 3 Short offline Completed without error 00% 6348 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.