  2. root@apophis:/# smartctl -a /dev/sdj
  3. smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
  4. Home page is http://smartmontools.sourceforge.net/
  5.  
  6. === START OF INFORMATION SECTION ===
  7. Model Family: SAMSUNG SpinPoint T166 series
  8. Device Model: SAMSUNG HD501LJ
  9. Serial Number: habichrausgeslöscht
  10. Firmware Version: CR100-11
  11. User Capacity: 500,107,862,016 bytes
  12. Device is: In smartctl database [for details use: -P show]
  13. ATA Version is: 8
  14. ATA Standard is: ATA-8-ACS revision 3b
  15. Local Time is: Tue Feb 15 23:23:03 2011 CET
  16. SMART support is: Available - device has SMART capability.
  17. SMART support is: Enabled
  18.  
  19. === START OF READ SMART DATA SECTION ===
  20. SMART overall-health self-assessment test result: PASSED
  21.  
  22. General SMART Values:
  23. Offline data collection status: (0x00) Offline data collection activity
  24. was never started.
  25. Auto Offline Data Collection: Disabled.
  26. Self-test execution status: ( 0) The previous self-test routine completed
  27. without error or no self-test has ever
  28. been run.
  29. Total time to complete Offline
  30. data collection: (9144) seconds.
  31. Offline data collection
  32. capabilities: (0x5b) SMART execute Offline immediate.
  33. Auto Offline data collection on/off support.
  34. Suspend Offline collection upon new
  35. command.
  36. Offline surface scan supported.
  37. Self-test supported.
  38. No Conveyance Self-test supported.
  39. Selective Self-test supported.
  40. SMART capabilities: (0x0003) Saves SMART data before entering
  41. power-saving mode.
  42. Supports SMART auto save timer.
  43. Error logging capability: (0x01) Error logging supported.
  44. General Purpose Logging supported.
  45. Short self-test routine
  46. recommended polling time: ( 2) minutes.
  47. Extended self-test routine
  48. recommended polling time: ( 156) minutes.
  49. SCT capabilities: (0x003f) SCT Status supported.
  50. SCT Feature Control supported.
  51. SCT Data Table supported.
  52.  
  53. SMART Attributes Data Structure revision number: 16
  54. Vendor Specific SMART Attributes with Thresholds:
  55. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  56. 1 Raw_Read_Error_Rate 0x000f 253 100 051 Pre-fail Always - 0
  57. 3 Spin_Up_Time 0x0007 100 100 015 Pre-fail Always - 6208
  58. 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 6
  59. 5 Reallocated_Sector_Ct 0x0033 253 253 010 Pre-fail Always - 0
  60. 7 Seek_Error_Rate 0x000f 253 253 051 Pre-fail Always - 0
  61. 8 Seek_Time_Performance 0x0025 253 253 015 Pre-fail Offline - 0
  62. 9 Power_On_Hours 0x0032 253 253 000 Old_age Always - 5
  63. 10 Spin_Retry_Count 0x0033 253 253 051 Pre-fail Always - 0
  64. 11 Calibration_Retry_Count 0x0012 253 253 000 Old_age Always - 0
  65. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 6
  66. 13 Read_Soft_Error_Rate 0x000e 253 100 000 Old_age Always - 0
  67. 187 Reported_Uncorrect 0x0032 253 253 000 Old_age Always - 0
  68. 188 Unknown_Attribute 0x0032 253 253 000 Old_age Always - 0
  69. 190 Airflow_Temperature_Cel 0x0022 068 068 000 Old_age Always - 32
  70. 194 Temperature_Celsius 0x0022 142 142 000 Old_age Always - 32
  71. 195 Hardware_ECC_Recovered 0x001a 253 100 000 Old_age Always - 0
  72. 196 Reallocated_Event_Count 0x0032 253 253 000 Old_age Always - 0
  73. 197 Current_Pending_Sector 0x0012 253 253 000 Old_age Always - 0
  74. 198 Offline_Uncorrectable 0x0030 253 253 000 Old_age Offline - 0
  75. 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
  76. 200 Multi_Zone_Error_Rate 0x000a 253 100 000 Old_age Always - 0
  77. 201 Soft_Read_Error_Rate 0x000a 253 100 000 Old_age Always - 0
  78. 202 TA_Increase_Count 0x0032 253 253 000 Old_age Always - 0
  79.  
  80. SMART Error Log Version: 1
  81. No Errors Logged
  82.  
  83. SMART Self-test log structure revision number 1
  84. No self-tests have been logged. [To run self-tests, use: smartctl -t]
  85.  
  86.  
  87. SMART Selective Self-Test Log Data Structure Revision Number (0) should be 1
  88. SMART Selective self-test log data structure revision number 0
  89. Warning: ATA Specification requires selective self-test log data structure revision number = 1
  90. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  91. 1 0 0 Not_testing
  92. 2 0 0 Not_testing
  93. 3 0 0 Not_testing
  94. 4 0 0 Not_testing
  95. 5 0 0 Not_testing
  96. Selective self-test flags (0x0):
  97. After scanning selected spans, do NOT read-scan remainder of disk.
  98. If Selective self-test is pending on power-up, resume after 0 minute delay.
  99.  
  100. root@apophis:/#