- root@apophis:/# smartctl -a /dev/sdj
- smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
- Home page is http://smartmontools.sourceforge.net/
- === START OF INFORMATION SECTION ===
- Model Family: SAMSUNG SpinPoint T166 series
- Device Model: SAMSUNG HD501LJ
- Serial Number: habichrausgeslöscht
- Firmware Version: CR100-11
- User Capacity: 500,107,862,016 bytes
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: 8
- ATA Standard is: ATA-8-ACS revision 3b
- Local Time is: Tue Feb 15 23:23:03 2011 CET
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: (9144) seconds.
- Offline data collection
- capabilities: (0x5b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- No Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 156) minutes.
- SCT capabilities: (0x003f) SCT Status supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 253 100 051 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0007 100 100 015 Pre-fail Always - 6208
- 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 6
- 5 Reallocated_Sector_Ct 0x0033 253 253 010 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x000f 253 253 051 Pre-fail Always - 0
- 8 Seek_Time_Performance 0x0025 253 253 015 Pre-fail Offline - 0
- 9 Power_On_Hours 0x0032 253 253 000 Old_age Always - 5
- 10 Spin_Retry_Count 0x0033 253 253 051 Pre-fail Always - 0
- 11 Calibration_Retry_Count 0x0012 253 253 000 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 6
- 13 Read_Soft_Error_Rate 0x000e 253 100 000 Old_age Always - 0
- 187 Reported_Uncorrect 0x0032 253 253 000 Old_age Always - 0
- 188 Unknown_Attribute 0x0032 253 253 000 Old_age Always - 0
- 190 Airflow_Temperature_Cel 0x0022 068 068 000 Old_age Always - 32
- 194 Temperature_Celsius 0x0022 142 142 000 Old_age Always - 32
- 195 Hardware_ECC_Recovered 0x001a 253 100 000 Old_age Always - 0
- 196 Reallocated_Event_Count 0x0032 253 253 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0012 253 253 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0030 253 253 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
- 200 Multi_Zone_Error_Rate 0x000a 253 100 000 Old_age Always - 0
- 201 Soft_Read_Error_Rate 0x000a 253 100 000 Old_age Always - 0
- 202 TA_Increase_Count 0x0032 253 253 000 Old_age Always - 0
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- No self-tests have been logged. [To run self-tests, use: smartctl -t]
- SMART Selective Self-Test Log Data Structure Revision Number (0) should be 1
- SMART Selective self-test log data structure revision number 0
- Warning: ATA Specification requires selective self-test log data structure revision number = 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.
- root@apophis:/#