- smartctl 5.42 2011-10-20 r3458 [i386-pc-solaris2.11] (local build)
- Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
- === START OF INFORMATION SECTION ===
- Model Family: Seagate Barracuda 7200.11
- Device Model: ST31500341AS
- Firmware Version: CC1H
- User Capacity: 1,500,301,910,016 bytes [1.50 TB]
- Sector Size: 512 bytes logical/physical
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: 8
- ATA Standard is: ATA-8-ACS revision 4
- Local Time is: Sat May 19 17:56:37 2012 PDT
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x82) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 625) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: ( 255) minutes.
- Conveyance self-test routine
- recommended polling time: ( 2) minutes.
- SCT capabilities: (0x103f) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 10
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 115 091 006 Pre-fail Always - 91902527
- 3 Spin_Up_Time 0x0003 100 100 000 Pre-fail Always - 0
- 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 8
- 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 22
- 7 Seek_Error_Rate 0x000f 061 060 030 Pre-fail Always - 1340955
- 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 428
- 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 8
- 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
- 187 Reported_Uncorrect 0x0032 001 001 000 Old_age Always - 227
- 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0
- 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
- 190 Airflow_Temperature_Cel 0x0022 062 057 045 Old_age Always - 38 (Min/Max 32/43)
- 194 Temperature_Celsius 0x0022 038 043 000 Old_age Always - 38 (0 21 0 0 0)
- 195 Hardware_ECC_Recovered 0x001a 031 030 000 Old_age Always - 91902527
- 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
- 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 186324271235500
- 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 2313148706
- 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 1107931434
- SMART Error Log Version: 1
- ATA Error Count: 212 (device log contains only the most recent five errors)
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 212 occurred at disk power-on lifetime: 64 hours (2 days + 16 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 f0 c0 2d 00 Error: UNC at LBA = 0x002dc0f0 = 2998512
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 00 00 95 c0 2d 40 00 2d+02:44:56.392 READ FPDMA QUEUED
- 2f 00 01 10 00 00 00 00 2d+02:44:56.313 READ LOG EXT
- 00 00 00 00 00 00 00 04 2d+02:44:56.263 NOP [Abort queued commands]
- 60 00 00 95 c0 2d 40 00 2d+02:44:53.452 READ FPDMA QUEUED
- 2f 00 01 10 00 00 00 00 2d+02:44:53.401 READ LOG EXT
- Error 211 occurred at disk power-on lifetime: 64 hours (2 days + 16 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 f0 c0 2d 00 Error: UNC at LBA = 0x002dc0f0 = 2998512
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 00 00 95 c0 2d 40 00 2d+02:44:53.452 READ FPDMA QUEUED
- 2f 00 01 10 00 00 00 00 2d+02:44:53.401 READ LOG EXT
- 00 00 00 00 00 00 00 04 2d+02:44:53.331 NOP [Abort queued commands]
- 60 00 00 95 c0 2d 40 00 2d+02:44:50.553 READ FPDMA QUEUED
- 2f 00 01 10 00 00 00 00 2d+02:44:50.474 READ LOG EXT
- Error 210 occurred at disk power-on lifetime: 64 hours (2 days + 16 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 f0 c0 2d 00 Error: UNC at LBA = 0x002dc0f0 = 2998512
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 00 00 95 c0 2d 40 00 2d+02:44:50.553 READ FPDMA QUEUED
- 2f 00 01 10 00 00 00 00 2d+02:44:50.474 READ LOG EXT
- 00 00 00 00 00 00 00 04 2d+02:44:50.424 NOP [Abort queued commands]
- 60 00 00 95 c0 2d 40 00 2d+02:44:47.632 READ FPDMA QUEUED
- 2f 00 01 10 00 00 00 00 2d+02:44:47.609 READ LOG EXT
- Error 209 occurred at disk power-on lifetime: 64 hours (2 days + 16 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 f0 c0 2d 00 Error: UNC at LBA = 0x002dc0f0 = 2998512
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 00 00 95 c0 2d 40 00 2d+02:44:47.632 READ FPDMA QUEUED
- 2f 00 01 10 00 00 00 00 2d+02:44:47.609 READ LOG EXT
- 00 00 00 00 00 00 00 04 2d+02:44:47.459 NOP [Abort queued commands]
- 60 00 10 ff ff ff 4f 00 2d+02:44:44.666 READ FPDMA QUEUED
- 60 00 10 ff ff ff 4f 00 2d+02:44:44.666 READ FPDMA QUEUED
- Error 208 occurred at disk power-on lifetime: 64 hours (2 days + 16 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 f0 c0 2d 00 Error: UNC at LBA = 0x002dc0f0 = 2998512
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 00 10 ff ff ff 4f 00 2d+02:44:44.666 READ FPDMA QUEUED
- 60 00 10 ff ff ff 4f 00 2d+02:44:44.666 READ FPDMA QUEUED
- 61 00 10 10 03 00 40 00 2d+02:44:44.660 WRITE FPDMA QUEUED
- 60 00 10 10 03 00 40 00 2d+02:44:44.608 READ FPDMA QUEUED
- 61 00 15 b9 69 04 42 00 2d+02:44:44.608 WRITE FPDMA QUEUED
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Extended offline Completed without error 00% 414 -
- # 2 Short offline Completed without error 00% 410 -
- # 3 Conveyance offline Completed without error 00% 410 -
- # 4 Extended offline Completed without error 00% 409 -
- # 5 Short offline Completed without error 00% 404 -
- # 6 Extended offline Completed: read failure 90% 244 2998512
- # 7 Conveyance offline Completed: read failure 90% 244 2998512
- # 8 Short offline Completed: read failure 90% 243 2998512
- # 9 Conveyance offline Completed: read failure 90% 237 2998512
- #10 Conveyance offline Completed: read failure 90% 237 2998512
- #11 Conveyance offline Completed: read failure 90% 237 2998512
- #12 Extended offline Completed: read failure 90% 237 2998512
- #13 Extended offline Completed: read failure 90% 237 2998512
- #14 Extended offline Completed: read failure 90% 237 2998512
- #15 Extended offline Completed: read failure 90% 237 2998512
- #16 Short offline Completed: read failure 90% 237 2998512
- #17 Extended offline Completed: read failure 90% 237 2998512
- #18 Short offline Completed: read failure 90% 237 2998512
- #19 Conveyance offline Completed: read failure 90% 234 2998512
- #20 Short offline Completed: read failure 90% 231 2998512
- 15 of 15 failed self-tests are outdated by newer successful extended offline self-test # 1
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.