- root@server:~# smartctl -a /dev/sda
- smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.10.23-xxxx-std-ipv6-64] (local build)
- Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
- === START OF INFORMATION SECTION ===
- Device Model: TOSHIBA DT01ACA200
- Serial Number: 135D5EVGS
- LU WWN Device Id: 5 000039 ff3c588e6
- Firmware Version: MX4OABB0
- User Capacity: 2,000,398,934,016 bytes [2.00 TB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Device is: Not in smartctl database [for details use: -P showall]
- ATA Version is: 8
- ATA Standard is: ATA-8-ACS revision 4
- Local Time is: Fri Sep 19 17:01:56 2014 MSK
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: FAILED!
- Drive failure expected in less than 24 hours. SAVE ALL DATA.
- See vendor-specific Attribute list for failed Attributes.
- General SMART Values:
- Offline data collection status: (0x84) Offline data collection activity
- was suspended by an interrupting command from host.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: (16639) seconds.
- Offline data collection
- capabilities: (0x5b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- No Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: ( 255) minutes.
- SCT capabilities: (0x003d) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000b 046 046 016 Pre-fail Always - 1808672204
- 2 Throughput_Performance 0x0005 139 139 054 Pre-fail Offline - 72
- 3 Spin_Up_Time 0x0007 132 132 024 Pre-fail Always - 286 (Average 288)
- 4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 74
- 5 Reallocated_Sector_Ct 0x0033 001 001 005 Pre-fail Always FAILING_NOW 2005
- 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0
- 8 Seek_Time_Performance 0x0005 124 124 020 Pre-fail Offline - 33
- 9 Power_On_Hours 0x0012 099 099 000 Old_age Always - 10552
- 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 74
- 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 103
- 193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always - 103
- 194 Temperature_Celsius 0x0002 139 139 000 Old_age Always - 43 (Min/Max 12/48)
- 196 Reallocated_Event_Count 0x0032 001 001 000 Old_age Always - 2247
- 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed without error 00% 9833 -
- # 2 Short offline Completed without error 00% 9825 -
- # 3 Short offline Completed without error 00% 8119 -
- # 4 Short offline Completed without error 00% 8119 -
- # 5 Short offline Completed without error 00% 8111 -
- # 6 Short offline Completed without error 00% 8062 -
- # 7 Short offline Completed without error 00% 351 -
- # 8 Short offline Completed without error 00% 340 -
- # 9 Short offline Completed without error 00% 340 -
- #10 Short offline Completed without error 00% 220 -
- #11 Short offline Completed without error 00% 220 -
- #12 Short offline Completed without error 00% 192 -
- #13 Short offline Completed without error 00% 192 -
- #14 Short offline Completed without error 00% 101 -
- #15 Short offline Completed without error 00% 101 -
- #16 Short offline Completed without error 00% 95 -
- #17 Short offline Completed without error 00% 94 -
- #18 Short offline Completed without error 00% 65 -
- #19 Short offline Completed without error 00% 65 -
- #20 Short offline Completed without error 00% 2 -
- #21 Short offline Completed without error 00% 2 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.