Advertisement
Guest User

Ubuntu-smartmontools

a guest
Feb 9th, 2017
98
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 9.71 KB | None | 0 0
  1. ubuntu@ubuntu:~$ sudo smartctl -a /dev/sda
  2. smartctl 6.5 2016-01-24 r4214 [x86_64-linux-4.4.0-31-generic] (local build)
  3. Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
  4.  
  5. === START OF INFORMATION SECTION ===
  6. Model Family: HGST Travelstar 7K1000
  7. Device Model: HGST HTS721010A9E630
  8. Serial Number: JR100X4M1DP32E
  9. LU WWN Device Id: 5 000cca 8a8d3db29
  10. Firmware Version: JB0OA3J0
  11. User Capacity: 1,000,204,886,016 bytes [1.00 TB]
  12. Sector Sizes: 512 bytes logical, 4096 bytes physical
  13. Rotation Rate: 7200 rpm
  14. Form Factor: 2.5 inches
  15. Device is: In smartctl database [for details use: -P show]
  16. ATA Version is: ATA8-ACS T13/1699-D revision 6
  17. SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
  18. Local Time is: Wed Feb 8 03:09:47 2017 UTC
  19. SMART support is: Available - device has SMART capability.
  20. SMART support is: Enabled
  21.  
  22. === START OF READ SMART DATA SECTION ===
  23. SMART overall-health self-assessment test result: PASSED
  24.  
  25. General SMART Values:
  26. Offline data collection status: (0x00) Offline data collection activity
  27. was never started.
  28. Auto Offline Data Collection: Disabled.
  29. Self-test execution status: ( 0) The previous self-test routine completed
  30. without error or no self-test has ever
  31. been run.
  32. Total time to complete Offline
  33. data collection: ( 45) seconds.
  34. Offline data collection
  35. capabilities: (0x5b) SMART execute Offline immediate.
  36. Auto Offline data collection on/off support.
  37. Suspend Offline collection upon new
  38. command.
  39. Offline surface scan supported.
  40. Self-test supported.
  41. No Conveyance Self-test supported.
  42. Selective Self-test supported.
  43. SMART capabilities: (0x0003) Saves SMART data before entering
  44. power-saving mode.
  45. Supports SMART auto save timer.
  46. Error logging capability: (0x01) Error logging supported.
  47. General Purpose Logging supported.
  48. Short self-test routine
  49. recommended polling time: ( 2) minutes.
  50. Extended self-test routine
  51. recommended polling time: ( 185) minutes.
  52. SCT capabilities: (0x003d) SCT Status supported.
  53. SCT Error Recovery Control supported.
  54. SCT Feature Control supported.
  55. SCT Data Table supported.
  56.  
  57. SMART Attributes Data Structure revision number: 16
  58. Vendor Specific SMART Attributes with Thresholds:
  59. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  60. 1 Raw_Read_Error_Rate 0x000b 100 100 062 Pre-fail Always - 0
  61. 2 Throughput_Performance 0x0005 100 100 040 Pre-fail Offline - 0
  62. 3 Spin_Up_Time 0x0007 120 120 033 Pre-fail Always - 2
  63. 4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 518
  64. 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 0
  65. 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0
  66. 8 Seek_Time_Performance 0x0005 100 100 040 Pre-fail Offline - 0
  67. 9 Power_On_Hours 0x0012 099 099 000 Old_age Always - 621
  68. 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0
  69. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 411
  70. 191 G-Sense_Error_Rate 0x000a 100 100 000 Old_age Always - 0
  71. 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 15
  72. 193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always - 6802
  73. 194 Temperature_Celsius 0x0002 153 153 000 Old_age Always - 39 (Min/Max 13/47)
  74. 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
  75. 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0
  76. 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0
  77. 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 13
  78. 223 Load_Retry_Count 0x000a 100 100 000 Old_age Always - 0
  79.  
  80. SMART Error Log Version: 1
  81. ATA Error Count: 13 (device log contains only the most recent five errors)
  82. CR = Command Register [HEX]
  83. FR = Features Register [HEX]
  84. SC = Sector Count Register [HEX]
  85. SN = Sector Number Register [HEX]
  86. CL = Cylinder Low Register [HEX]
  87. CH = Cylinder High Register [HEX]
  88. DH = Device/Head Register [HEX]
  89. DC = Device Command Register [HEX]
  90. ER = Error register [HEX]
  91. ST = Status register [HEX]
  92. Powered_Up_Time is measured from power on, and printed as
  93. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  94. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  95.  
  96. Error 13 occurred at disk power-on lifetime: 549 hours (22 days + 21 hours)
  97. When the command that caused the error occurred, the device was active or idle.
  98.  
  99. After command completion occurred, registers were:
  100. ER ST SC SN CL CH DH
  101. — — — — — — —
  102. 84 51 78 40 26 5b 02 Error: ICRC, ABRT at LBA = 0x025b2640 = 39528000
  103.  
  104. Commands leading to the command that caused the error were:
  105. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  106. — — — — — — — — —------------— —------------------
  107. 61 68 00 50 24 5b 40 00 00:10:16.340 WRITE FPDMA QUEUED
  108. 61 58 f0 f0 8e ae 40 00 00:10:16.300 WRITE FPDMA QUEUED
  109. 61 08 e8 30 7c ae 40 00 00:10:16.296 WRITE FPDMA QUEUED
  110. 61 08 e0 30 7c ae 40 00 00:10:16.296 WRITE FPDMA QUEUED
  111. ea 00 00 00 00 00 a0 00 00:10:16.281 FLUSH CACHE EXT
  112.  
  113. Error 12 occurred at disk power-on lifetime: 524 hours (21 days + 20 hours)
  114. When the command that caused the error occurred, the device was active or idle.
  115.  
  116. After command completion occurred, registers were:
  117. ER ST SC SN CL CH DH
  118. — — — — — — —
  119. 84 51 08 d0 02 94 00 Error: ICRC, ABRT at LBA = 0x009402d0 = 9700048
  120.  
  121. Commands leading to the command that caused the error were:
  122. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  123. — — — — — — — — —------------— —------------------
  124. 61 88 e0 50 fe 93 40 00 00:11:58.778 WRITE FPDMA QUEUED
  125. 61 00 d8 50 f6 93 40 00 00:11:58.778 WRITE FPDMA QUEUED
  126. 61 08 d0 78 0b 83 40 00 00:11:58.778 WRITE FPDMA QUEUED
  127. 61 90 c8 b8 b7 43 40 00 00:11:58.777 WRITE FPDMA QUEUED
  128. 61 18 c0 80 08 88 40 00 00:11:58.777 WRITE FPDMA QUEUED
  129.  
  130. Error 11 occurred at disk power-on lifetime: 524 hours (21 days + 20 hours)
  131. When the command that caused the error occurred, the device was active or idle.
  132.  
  133. After command completion occurred, registers were:
  134. ER ST SC SN CL CH DH
  135. — — — — — — —
  136. 84 51 60 a0 f0 cb 0f Error: ICRC, ABRT at LBA = 0x0fcbf0a0 = 265023648
  137.  
  138. Commands leading to the command that caused the error were:
  139. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  140. — — — — — — — — —------------— —------------------
  141. 60 88 10 30 93 c9 40 00 00:02:29.269 READ FPDMA QUEUED
  142. 61 00 08 00 f0 cb 40 00 00:02:29.260 WRITE FPDMA QUEUED
  143. 61 00 00 00 e8 cb 40 00 00:02:29.260 WRITE FPDMA QUEUED
  144. 60 08 f0 48 0b bf 40 00 00:02:29.260 READ FPDMA QUEUED
  145. 60 20 e8 70 92 c9 40 00 00:02:29.258 READ FPDMA QUEUED
  146.  
  147. Error 10 occurred at disk power-on lifetime: 509 hours (21 days + 5 hours)
  148. When the command that caused the error occurred, the device was active or idle.
  149.  
  150. After command completion occurred, registers were:
  151. ER ST SC SN CL CH DH
  152. — — — — — — —
  153. 84 51 70 50 ec 12 00 Error: ICRC, ABRT at LBA = 0x0012ec50 = 1240144
  154.  
  155. Commands leading to the command that caused the error were:
  156. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  157. — — — — — — — — —------------— —------------------
  158. 61 00 d8 00 a8 13 40 00 03:01:00.965 WRITE FPDMA QUEUED
  159. 61 00 d0 00 a0 13 40 00 03:01:00.964 WRITE FPDMA QUEUED
  160. 61 00 c8 00 98 13 40 00 03:01:00.964 WRITE FPDMA QUEUED
  161. 61 00 c0 00 90 13 40 00 03:01:00.964 WRITE FPDMA QUEUED
  162. 61 00 b8 00 88 13 40 00 03:01:00.964 WRITE FPDMA QUEUED
  163.  
  164. Error 9 occurred at disk power-on lifetime: 440 hours (18 days + 8 hours)
  165. When the command that caused the error occurred, the device was active or idle.
  166.  
  167. After command completion occurred, registers were:
  168. ER ST SC SN CL CH DH
  169. — — — — — — —
  170. 84 51 80 40 2d 47 07 Error: ICRC, ABRT at LBA = 0x07472d40 = 122105152
  171.  
  172. Commands leading to the command that caused the error were:
  173. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  174. — — — — — — — — —------------— —------------------
  175. 61 00 f8 50 5e 48 40 00 00:45:44.385 WRITE FPDMA QUEUED
  176. 61 00 f0 50 5d 48 40 00 00:45:44.385 WRITE FPDMA QUEUED
  177. 61 00 e8 50 5c 48 40 00 00:45:44.385 WRITE FPDMA QUEUED
  178. 61 00 e0 50 5b 48 40 00 00:45:44.385 WRITE FPDMA QUEUED
  179. 61 00 d8 50 5a 48 40 00 00:45:44.385 WRITE FPDMA QUEUED
  180.  
  181. SMART Self-test log structure revision number 1
  182. No self-tests have been logged. [To run self-tests, use: smartctl -t]
  183.  
  184. SMART Selective self-test log data structure revision number 1
  185. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  186. 1 0 0 Not_testing
  187. 2 0 0 Not_testing
  188. 3 0 0 Not_testing
  189. 4 0 0 Not_testing
  190. 5 0 0 Not_testing
  191. Selective self-test flags (0x0):
  192. After scanning selected spans, do NOT read-scan remainder of disk.
  193. If Selective self-test is pending on power-up, resume after 0 minute delay.