Advertisement
Not a member of Pastebin yet?
Sign Up,
it unlocks many cool features!
- ~ # MegaCli -AdpAllInfo -aALL
- Adapter #0
- ==============================================================================
- Versions
- ================
- Product Name : LSI MegaRAID ROMB
- Serial No :
- FW Package Build: 20.9.1-0011
- Mfg. Data
- ================
- Mfg. Date : 00/00/00
- Rework Date : 00/00/00
- Revision No :
- Battery FRU : N/A
- Image Versions in Flash:
- ================
- BIOS Version : 4.18.00_4.09.05.00_0x0416A000
- Preboot CLI Version: 03.02-012:#%00008
- WebBIOS Version : 4.0-42-e_30-Rel
- NVDATA Version : 3.08.03-0006
- FW Version : 2.110.04-0967
- Boot Block Version : 2.01.00.00-0019
- Pending Images in Flash
- ================
- None
- PCI Info
- ================
- Vendor Id : 1000
- Device Id : 0073
- SubVendorId : 1043
- SubDeviceId : 843b
- Host Interface : PCIE
- Number of Frontend Port: 0
- Device Interface : PCIE
- Number of Backend Port: 8
- Port : Address
- 0 5000c50042e37119
- 1 5000c50042e31e5d
- 2 4433221102000000
- 3 4433221103000000
- 4 0000000000000000
- 5 0000000000000000
- 6 0000000000000000
- 7 0000000000000000
- HW Configuration
- ================
- SAS Address : 500e0180001390f0
- BBU : Absent
- Alarm : Absent
- NVRAM : Present
- Serial Debugger : Present
- Memory : Absent
- Flash : Present
- Memory Size : 0MB
- TPM : Absent
- On board Expander: Absent
- Upgrade Key : Absent
- Temperature sensor for ROC : Absent
- Temperature sensor for controller : Absent
- Settings
- ================
- Current Time : 14:18:45 7/18, 2012
- Predictive Fail Poll Interval : 300sec
- Interrupt Throttle Active Count : 16
- Interrupt Throttle Completion : 50us
- Rebuild Rate : 30%
- PR Rate : 30%
- BGI Rate : 30%
- Check Consistency Rate : 30%
- Reconstruction Rate : 0%
- Cache Flush Interval : 4s
- Max Drives to Spinup at One Time : 2
- Delay Among Spinup Groups : 1s
- Physical Drive Coercion Mode : Disabled
- Cluster Mode : Disabled
- Alarm : Disabled
- Auto Rebuild : Enabled
- Battery Warning : Disabled
- Ecc Bucket Size : 15
- Ecc Bucket Leak Rate : 1440 Minutes
- Restore HotSpare on Insertion : Disabled
- Expose Enclosure Devices : Enabled
- Maintain PD Fail History : Enabled
- Host Request Reordering : Enabled
- Auto Detect BackPlane Enabled : SGPIO
- Load Balance Mode : Auto
- Use FDE Only : No
- Security Key Assigned : No
- Security Key Failed : No
- Security Key Not Backedup : No
- Default LD PowerSave Policy : Controller Defined
- Maximum number of direct attached drives to spin up in 1 min : 0
- Any Offline VD Cache Preserved : No
- Allow Boot with Preserved Cache : No
- Disable Online Controller Reset : No
- PFK in NVRAM : No
- Use disk activity for locate : Yes
- Capabilities
- ================
- RAID Level Supported : RAID0, RAID1, RAID5, RAID00, RAID10, RAID50, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span
- Supported Drives : SAS, SATA
- Allowed Mixing:
- Mix in Enclosure Allowed
- Mix of SAS/SATA of HDD type in VD Allowed
- Status
- ================
- ECC Bucket Count : 0
- Limitations
- ================
- Max Arms Per VD : 8
- Max Spans Per VD : 2
- Max Arrays : 2
- Max Number of VDs : 2
- Max Parallel Commands : 16
- Max SGE Count : 60
- Max Data Transfer Size : 8192 sectors
- Max Strips PerIO : 20
- Max LD per array : 2
- Min Strip Size : 8 KB
- Max Strip Size : 64 KB
- Max Configurable CacheCade Size: 0 GB
- Current Size of CacheCade : 0 GB
- Current Size of FW Cache : 0 MB
- Device Present
- ================
- Virtual Drives : 2
- Degraded : 1
- Offline : 0
- Physical Devices : 5
- Disks : 4
- Critical Disks : 0
- Failed Disks : 1
- Supported Adapter Operations
- ================
- Rebuild Rate : Yes
- CC Rate : Yes
- BGI Rate : Yes
- Reconstruct Rate : No
- Patrol Read Rate : Yes
- Alarm Control : Yes
- Cluster Support : No
- BBU : Yes
- Spanning : Yes
- Dedicated Hot Spare : No
- Revertible Hot Spares : Yes
- Foreign Config Import : Yes
- Self Diagnostic : Yes
- Allow Mixed Redundancy on Array : No
- Global Hot Spares : Yes
- Deny SCSI Passthrough : No
- Deny SMP Passthrough : No
- Deny STP Passthrough : No
- Support Security : No
- Snapshot Enabled : No
- Support the OCE without adding drives : Yes
- Support PFK : Yes
- Support PI : No
- Support Boot Time PFK Change : No
- Disable Online PFK Change : No
- PFK TrailTime Remaining : 0 days 0 hours
- Support Shield State : No
- Block SSD Write Disk Cache Change: No
- Supported VD Operations
- ================
- Read Policy : No
- Write Policy : No
- IO Policy : No
- Access Policy : Yes
- Disk Cache Policy : Yes
- Reconstruction : No
- Deny Locate : No
- Deny CC : No
- Allow Ctrl Encryption: No
- Enable LDBBM : No
- Support Breakmirror : No
- Power Savings : No
- Supported PD Operations
- ================
- Force Online : Yes
- Force Offline : Yes
- Force Rebuild : Yes
- Deny Force Failed : No
- Deny Force Good/Bad : No
- Deny Missing Replace : No
- Deny Clear : No
- Deny Locate : No
- Support Temperature : No
- Disable Copyback : No
- Enable JBOD : No
- Enable Copyback on SMART : No
- Enable Copyback to SSD on SMART Error : Yes
- Enable SSD Patrol Read : No
- PR Correct Unconfigured Areas : Yes
- Error Counters
- ================
- Memory Correctable Errors : 0
- Memory Uncorrectable Errors : 0
- Cluster Information
- ================
- Cluster Permitted : No
- Cluster Active : No
- Default Settings
- ================
- Phy Polarity : 0
- Phy PolaritySplit : 0
- Background Rate : 30
- Strip Size : 64kB
- Flush Time : 4 seconds
- Write Policy : WT
- Read Policy : None
- Cache When BBU Bad : Disabled
- Cached IO : No
- SMART Mode : Mode 6
- Alarm Disable : No
- Coercion Mode : None
- ZCR Config : Unknown
- Dirty LED Shows Drive Activity : No
- BIOS Continue on Error : No
- Spin Down Mode : None
- Allowed Device Type : SAS/SATA Mix
- Allow Mix in Enclosure : Yes
- Allow HDD SAS/SATA Mix in VD : Yes
- Allow SSD SAS/SATA Mix in VD : No
- Allow HDD/SSD Mix in VD : No
- Allow SATA in Cluster : No
- Max Chained Enclosures : 2
- Disable Ctrl-R : Yes
- Enable Web BIOS : Yes
- Direct PD Mapping : No
- BIOS Enumerate VDs : Yes
- Restore Hot Spare on Insertion : No
- Expose Enclosure Devices : Yes
- Maintain PD Fail History : Yes
- Disable Puncturing : Yes
- Zero Based Enclosure Enumeration : No
- PreBoot CLI Enabled : Yes
- LED Show Drive Activity : Yes
- Cluster Disable : Yes
- SAS Disable : No
- Auto Detect BackPlane Enable : SGPIO
- Use FDE Only : No
- Enable Led Header : No
- Delay during POST : 0
- EnableCrashDump : No
- Disable Online Controller Reset : No
- EnableLDBBM : No
- Un-Certified Hard Disk Drives : Allow
- Treat Single span R1E as R10 : No
- Max LD per array : 16
- Power Saving option : All power saving options are disabled
- Default spin down time in minutes: 30
- Enable JBOD : No
- TTY Log In Flash : Yes
- Auto Enhanced Import : No
- BreakMirror RAID Support : No
- Disable Join Mirror : No
- Enable Shield State : No
- Time taken to detect CME : 60s
- Exit Code: 0x00
- ~ # MegaCli -PDList -aALL
- Adapter #0
- Enclosure Device ID: 64
- Slot Number: 1
- Enclosure position: 0
- Device Id: 6
- WWN: 5000C50042E31E5C
- Sequence Number: 2
- Media Error Count: 0
- Other Error Count: 0
- Predictive Failure Count: 0
- Last Predictive Failure Event Seq Number: 0
- PD Type: SAS
- Raw Size: 279.396 GB [0x22ecb25c Sectors]
- Non Coerced Size: 278.896 GB [0x22dcb25c Sectors]
- Coerced Size: 278.875 GB [0x22dc0000 Sectors]
- Firmware state: Unconfigured(bad)
- Device Firmware Level: 0008
- Shield Counter: 0
- Successful diagnostics completion on : N/A
- SAS Address(0): 0x5000c50042e31e5d
- SAS Address(1): 0x0
- Connected Port Number: 1(path0)
- Inquiry Data: SEAGATE ST3300657SS 00086SJ398MY
- FDE Enable: Disable
- Secured: Unsecured
- Locked: Unlocked
- Needs EKM Attention: No
- Foreign State: Foreign
- Foreign Secure: Drive is not secured by a foreign lock key
- Device Speed: 6.0Gb/s
- Link Speed: 6.0Gb/s
- Media Type: Hard Disk Device
- Drive Temperature :31C (87.80 F)
- PI Eligibility: No
- Drive is formatted for PI information: No
- PI: No PI
- Drive's write cache : Disabled
- Port-0 :
- Port status: Active
- Port's Linkspeed: 6.0Gb/s
- Port-1 :
- Port status: Active
- Port's Linkspeed: Unknown
- Drive has flagged a S.M.A.R.T alert : No
- Enclosure Device ID: 64
- Slot Number: 2
- Drive's postion: DiskGroup: 0, Span: 0, Arm: 1
- Enclosure position: 0
- Device Id: 8
- WWN:
- Sequence Number: 2
- Media Error Count: 0
- Other Error Count: 0
- Predictive Failure Count: 0
- Last Predictive Failure Event Seq Number: 0
- PD Type: SATA
- Raw Size: 2.728 TB [0x15d50a3b0 Sectors]
- Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors]
- Coerced Size: 2.728 TB [0x15d400000 Sectors]
- Firmware state: Online, Spun Up
- Device Firmware Level: 0003
- Shield Counter: 0
- Successful diagnostics completion on : N/A
- SAS Address(0): 0x4433221102000000
- Connected Port Number: 2(path0)
- Inquiry Data: Z2904R6AST33000650NS 0003
- FDE Enable: Disable
- Secured: Unsecured
- Locked: Unlocked
- Needs EKM Attention: No
- Foreign State: None
- Device Speed: 6.0Gb/s
- Link Speed: 6.0Gb/s
- Media Type: Hard Disk Device
- Drive Temperature : N/A
- PI Eligibility: No
- Drive is formatted for PI information: No
- PI: No PI
- Drive's write cache : Disabled
- Drive's NCQ setting : Disabled
- Port-0 :
- Port status: Active
- Port's Linkspeed: 6.0Gb/s
- Drive has flagged a S.M.A.R.T alert : No
- Enclosure Device ID: 64
- Slot Number: 3
- Drive's postion: DiskGroup: 0, Span: 0, Arm: 0
- Enclosure position: 0
- Device Id: 7
- WWN:
- Sequence Number: 2
- Media Error Count: 0
- Other Error Count: 0
- Predictive Failure Count: 0
- Last Predictive Failure Event Seq Number: 0
- PD Type: SATA
- Raw Size: 2.728 TB [0x15d50a3b0 Sectors]
- Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors]
- Coerced Size: 2.728 TB [0x15d400000 Sectors]
- Firmware state: Online, Spun Up
- Device Firmware Level: 0003
- Shield Counter: 0
- Successful diagnostics completion on : N/A
- SAS Address(0): 0x4433221103000000
- Connected Port Number: 3(path0)
- Inquiry Data: Z2917S7YST33000650NS 0003
- FDE Enable: Disable
- Secured: Unsecured
- Locked: Unlocked
- Needs EKM Attention: No
- Foreign State: None
- Device Speed: 6.0Gb/s
- Link Speed: 6.0Gb/s
- Media Type: Hard Disk Device
- Drive Temperature : N/A
- PI Eligibility: No
- Drive is formatted for PI information: No
- PI: No PI
- Drive's write cache : Disabled
- Drive's NCQ setting : Disabled
- Port-0 :
- Port status: Active
- Port's Linkspeed: 6.0Gb/s
- Drive has flagged a S.M.A.R.T alert : No
- Enclosure Device ID: 64
- Slot Number: 0
- Drive's postion: DiskGroup: 1, Span: 0, Arm: 1
- Enclosure position: 0
- Device Id: 5
- WWN: 5000C50042E37118
- Sequence Number: 2
- Media Error Count: 0
- Other Error Count: 0
- Predictive Failure Count: 0
- Last Predictive Failure Event Seq Number: 0
- PD Type: SAS
- Raw Size: 279.396 GB [0x22ecb25c Sectors]
- Non Coerced Size: 278.896 GB [0x22dcb25c Sectors]
- Coerced Size: 278.875 GB [0x22dc0000 Sectors]
- Firmware state: Online, Spun Up
- Device Firmware Level: 0008
- Shield Counter: 0
- Successful diagnostics completion on : N/A
- SAS Address(0): 0x5000c50042e37119
- SAS Address(1): 0x0
- Connected Port Number: 0(path0)
- Inquiry Data: SEAGATE ST3300657SS 00086SJ396GW
- FDE Enable: Disable
- Secured: Unsecured
- Locked: Unlocked
- Needs EKM Attention: No
- Foreign State: None
- Device Speed: 6.0Gb/s
- Link Speed: 6.0Gb/s
- Media Type: Hard Disk Device
- Drive Temperature :31C (87.80 F)
- PI Eligibility: No
- Drive is formatted for PI information: No
- PI: No PI
- Drive's write cache : Disabled
- Port-0 :
- Port status: Active
- Port's Linkspeed: 6.0Gb/s
- Port-1 :
- Port status: Active
- Port's Linkspeed: Unknown
- Drive has flagged a S.M.A.R.T alert : No
Advertisement
Add Comment
Please, Sign In to add comment
Advertisement