- smartctl version 5.38 [x86_64-unknown-linux-gnu] Copyright (C) 2002-8 Bruce Allen
- Home page is http://smartmontools.sourceforge.net/
- === START OF INFORMATION SECTION ===
- Model Family: SAMSUNG SpinPoint P80 series
- Device Model: SAMSUNG SP1614C
- Serial Number: S01XJ10XC15814
- Firmware Version: SW100-30
- User Capacity: 160.041.885.696 bytes
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: 7
- ATA Standard is: ATA/ATAPI-7 T13 1532D revision 0
- Local Time is: Sun Jan 17 10:01:11 2010 CET
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x02) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: (6000) seconds.
- Offline data collection
- capabilities: (0x1b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- No Conveyance Self-test supported.
- No Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- No General Purpose Logging support.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: ( 100) minutes.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0007 100 100 025 Pre-fail Always - 5632
- 4 Start_Stop_Count 0x0032 099 099 000 Old_age Always - 1324
- 5 Reallocated_Sector_Ct 0x0033 100 100 011 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0
- 8 Seek_Time_Performance 0x0025 100 100 015 Pre-fail Offline - 10337
- 9 Power_On_Half_Minutes 0x0032 100 100 000 Old_age Always - 2110h+08m
- 10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always - 0
- 11 Calibration_Retry_Count 0x0012 100 100 000 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 1087
- 194 Temperature_Celsius 0x0022 133 085 000 Old_age Always - 35
- 195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 103944
- 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 2
- 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 2
- 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 225
- 200 Multi_Zone_Error_Rate 0x000a 100 100 051 Old_age Always - 0
- 201 Soft_Read_Error_Rate 0x000a 100 100 051 Old_age Always - 0
- SMART Error Log Version: 1
- ATA Error Count: 1771 (device log contains only the most recent five errors)
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 1771 occurred at disk power-on lifetime: 1941 hours (80 days + 21 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 01 51 08 b8 a7 bd ed Error: AMNF 8 sectors at LBA = 0x0dbda7b8 = 230533048
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 08 b8 a7 bd ed 00 07:16:20.813 READ DMA
- ec 00 00 00 00 00 a0 00 07:16:20.813 IDENTIFY DEVICE
- ef 03 42 00 00 00 a0 00 07:16:20.813 SET FEATURES [Set transfer mode]
- ec 00 00 00 00 00 a0 00 07:16:20.813 IDENTIFY DEVICE
- Error 1770 occurred at disk power-on lifetime: 1941 hours (80 days + 21 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 01 51 08 b8 a7 bd ed Error: AMNF 8 sectors at LBA = 0x0dbda7b8 = 230533048
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 08 b8 a7 bd ed 00 07:16:19.688 READ DMA
- ec 00 00 00 00 00 a0 00 07:16:19.688 IDENTIFY DEVICE
- ef 03 42 00 00 00 a0 00 07:16:19.688 SET FEATURES [Set transfer mode]
- ec 00 00 00 00 00 a0 00 07:16:19.688 IDENTIFY DEVICE
- Error 1769 occurred at disk power-on lifetime: 1941 hours (80 days + 21 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 01 51 08 b8 a7 bd ed Error: AMNF 8 sectors at LBA = 0x0dbda7b8 = 230533048
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 08 b8 a7 bd ed 00 07:16:18.563 READ DMA
- ec 00 00 00 00 00 a0 00 07:16:18.563 IDENTIFY DEVICE
- ef 03 42 00 00 00 a0 00 07:16:18.563 SET FEATURES [Set transfer mode]
- ec 00 00 00 00 00 a0 00 07:16:18.563 IDENTIFY DEVICE
- Error 1768 occurred at disk power-on lifetime: 1941 hours (80 days + 21 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 01 51 08 b8 a7 bd ed Error: AMNF 8 sectors at LBA = 0x0dbda7b8 = 230533048
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 08 b8 a7 bd ed 00 07:16:17.375 READ DMA
- ec 00 00 00 00 00 a0 00 07:16:17.375 IDENTIFY DEVICE
- ef 03 42 00 00 00 a0 00 07:16:17.375 SET FEATURES [Set transfer mode]
- ec 00 00 00 00 00 a0 00 07:16:17.375 IDENTIFY DEVICE
- Error 1767 occurred at disk power-on lifetime: 1941 hours (80 days + 21 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 08 b8 a7 bd ed Error: UNC 8 sectors at LBA = 0x0dbda7b8 = 230533048
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 08 b8 a7 bd ed 00 07:16:16.250 READ DMA
- ec 00 00 00 00 00 a0 00 07:16:16.250 IDENTIFY DEVICE
- ef 03 42 00 00 00 a0 00 07:16:16.250 SET FEATURES [Set transfer mode]
- ec 00 00 00 00 00 a0 00 07:16:16.250 IDENTIFY DEVICE
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed without error 00% 2101 -
- Device does not support Selective Self Tests/Logging