- [omleny@sweethome ~]$ sudo smartctl -a /dev/sda
- smartctl version 5.38 [x86_64-unknown-linux-gnu] Copyright (C) 2002-8 Bruce Allen
- Home page is http://smartmontools.sourceforge.net/
- === START OF INFORMATION SECTION ===
- Device Model: FUJITSU MHZ2160BH G2
- Serial Number: K616T974DVV4
- Firmware Version: 8909
- User Capacity: 160.041.885.696 bytes
- Device is: Not in smartctl database [for details use: -P showall]
- ATA Version is: 8
- ATA Standard is: ATA-8-ACS revision 3f
- Local Time is: Sat Nov 7 00:29:20 2009 CET
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 649) seconds.
- Offline data collection
- capabilities: (0x51) SMART execute Offline immediate.
- No Auto Offline data collection support.
- Suspend Offline collection upon new
- command.
- No Offline surface scan supported.
- Self-test supported.
- No Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 92) minutes.
- SCT capabilities: (0x003f) SCT Status supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 100 100 046 Pre-fail Always - 188507
- 2 Throughput_Performance 0x0005 100 100 030 Pre-fail Offline - 27590656
- 3 Spin_Up_Time 0x0003 100 100 025 Pre-fail Always - 1
- 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 87
- 5 Reallocated_Sector_Ct 0x0033 100 100 024 Pre-fail Always - 8589934592000
- 7 Seek_Error_Rate 0x000f 100 100 047 Pre-fail Always - 1661
- 8 Seek_Time_Performance 0x0005 100 100 019 Pre-fail Offline - 0
- 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 48
- 10 Spin_Retry_Count 0x0013 100 100 020 Pre-fail Always - 0
- 11 Calibration_Retry_Count 0x0032 253 253 000 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 49
- 182 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0
- 184 Unknown_Attribute 0x0033 253 253 097 Pre-fail Always - 0
- 185 Unknown_Attribute 0x0010 253 253 000 Old_age Offline - 0
- 186 Unknown_Attribute 0x0032 253 253 000 Old_age Always - 0
- 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 47244640256
- 188 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0
- 189 High_Fly_Writes 0x003a 253 100 000 Old_age Always - 0
- 190 Airflow_Temperature_Cel 0x0022 061 055 000 Old_age Always - 39 (Lifetime Min/Max 24/40)
- 191 G-Sense_Error_Rate 0x0032 253 253 000 Old_age Always - 16580608
- 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 327685
- 193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 1503
- 195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 178
- 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 452788224
- 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x003e 200 253 000 Old_age Always - 0
- 200 Multi_Zone_Error_Rate 0x000f 100 100 060 Pre-fail Always - 25380
- 203 Run_Out_Cancel 0x0002 100 100 000 Old_age Always - 429502758674
- 240 Head_Flying_Hours 0x003e 200 200 000 Old_age Always - 0
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed without error 00% 19 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.