- === START OF READ SMART DATA SECTION ===
- SMART Status not supported: Incomplete response, ATA output registers missing
- SMART overall-health self-assessment test result: PASSED
- Warning: This result is based on an Attribute check.
- General SMART Values:
- Offline data collection status: (0x84) Offline data collection activity
- was suspended by an interrupting command from host.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 121) The previous self-test completed having
- the read element of the test failed.
- Total time to complete Offline
- data collection: (35100) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 381) minutes.
- Conveyance self-test routine
- recommended polling time: ( 5) minutes.
- SCT capabilities: (0x703d) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x002f 199 179 051 Pre-fail Always - 7
- 3 Spin_Up_Time 0x0027 226 226 021 Pre-fail Always - 7658
- 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 43
- 5 Reallocated_Sector_Ct 0x0033 189 189 140 Pre-fail Always - 365
- 7 Seek_Error_Rate 0x002f 100 253 051 Pre-fail Always - 0
- 9 Power_On_Hours 0x0032 081 081 000 Old_age Always - 14397
- 10 Spin_Retry_Count 0x0033 100 253 051 Pre-fail Always - 0
- 11 Calibration_Retry_Count 0x0033 100 253 051 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 43
- 180 Unknown_HDD_Attribute 0x002f 200 200 100 Pre-fail Always - 0
- 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0
- 184 End-to-End_Error 0x0033 100 100 097 Pre-fail Always - 0
- 187 Reported_Uncorrect 0x0032 093 001 000 Old_age Always - 857
- 188 Command_Timeout 0x0032 093 001 000 Old_age Always - 12885295928
- 190 Airflow_Temperature_Cel 0x0022 063 052 045 Old_age Always - 37
- 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 42
- 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 186
- 194 Temperature_Celsius 0x0022 115 104 000 Old_age Always - 37
- 196 Reallocated_Event_Count 0x0033 200 200 140 Pre-fail Always - 31
- 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 31
- 198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
- 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0
- SMART Error Log Version: 1
- ATA Error Count: 10 (device log contains only the most recent five errors)
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 10 occurred at disk power-on lifetime: 14393 hours (599 days + 17 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 04 51 01 00 00 00 00 Error: ABRT
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- b0 d6 01 e0 4f c2 00 00 12:58:30.595 SMART WRITE LOG
- b0 d5 01 e0 4f c2 00 00 12:58:30.595 SMART READ LOG
- ec 00 01 00 00 00 00 00 12:58:30.587 IDENTIFY DEVICE
- ec 00 00 00 00 00 00 00 12:58:30.586 IDENTIFY DEVICE
- Error 9 occurred at disk power-on lifetime: 14376 hours (599 days + 0 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 04 51 01 00 00 00 00 Error: ABRT
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- b0 d6 01 e0 4f c2 00 00 1d+00:35:51.549 SMART WRITE LOG
- b0 d5 01 e0 4f c2 00 00 1d+00:35:51.549 SMART READ LOG
- ec 00 01 00 00 00 00 00 1d+00:35:51.543 IDENTIFY DEVICE
- ec 00 00 00 00 00 00 00 1d+00:35:51.543 IDENTIFY DEVICE
- Error 8 occurred at disk power-on lifetime: 14376 hours (599 days + 0 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 04 51 01 00 00 00 00 Error: ABRT
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- b0 d6 01 e0 4f c2 00 00 1d+00:05:43.729 SMART WRITE LOG
- b0 d5 01 e0 4f c2 00 00 1d+00:05:43.729 SMART READ LOG
- ec 00 01 00 00 00 00 00 1d+00:05:43.723 IDENTIFY DEVICE
- ec 00 00 00 00 00 00 00 1d+00:05:43.722 IDENTIFY DEVICE
- Error 7 occurred at disk power-on lifetime: 14376 hours (599 days + 0 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 04 51 01 00 00 00 00 Error: ABRT
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- b0 d6 01 e0 4f c2 00 00 1d+00:05:37.469 SMART WRITE LOG
- b0 d5 01 e0 4f c2 00 00 1d+00:05:37.469 SMART READ LOG
- ec 00 01 00 00 00 00 00 1d+00:05:37.463 IDENTIFY DEVICE
- ec 00 00 00 00 00 00 00 1d+00:05:37.463 IDENTIFY DEVICE
- b0 d5 01 e0 4f c2 00 00 1d+00:05:34.293 SMART READ LOG
- Error 6 occurred at disk power-on lifetime: 14376 hours (599 days + 0 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 04 51 01 00 00 00 00 Error: ABRT
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- b0 d6 01 e0 4f c2 00 00 1d+00:05:34.280 SMART WRITE LOG
- b0 d5 01 e0 4f c2 00 00 1d+00:05:34.280 SMART READ LOG
- ec 00 01 00 00 00 00 00 1d+00:05:34.275 IDENTIFY DEVICE
- ec 00 00 00 00 00 00 00 1d+00:05:34.274 IDENTIFY DEVICE
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Extended offline Completed: read failure 90% 14393 625116232
- # 2 Short offline Completed without error 00% 14392 -