  1. 2016-03-08 15:47:18.177 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: f7 01 00 2a 00 05 c9 57
  2. 2016-03-08 15:47:18.177 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  3. 2016-03-08 15:47:18.177 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@e9f6f5a (unit id 247 & transaction 1163). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  4. 2016-03-08 15:47:18.233 [INFO ] [runtime.busevents ] - agsBusMasterControlDoors state updated to ON
  5. 2016-03-08 15:47:18.233 [INFO ] [runtime.busevents ] - agsBusMasterControlMasterSwitchOn state updated to ON
  6. 2016-03-08 15:47:18.233 [INFO ] [runtime.busevents ] - agsBusMasterControlMasterSwitchOff state updated to ON
  7. 2016-03-08 15:47:18.517 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 05 01 00 00 00 28 3d 90
  8. 2016-03-08 15:47:18.517 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  9. 2016-03-08 15:47:18.517 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@49842e6b (unit id 5 & transaction 1164). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  10. 2016-03-08 15:47:18.577 [INFO ] [runtime.busevents ] - IRvorneEventShort state updated to OFF
  11. 2016-03-08 15:47:18.577 [INFO ] [runtime.busevents ] - IRvorneEventRisingEdge state updated to OFF
  12. 2016-03-08 15:47:18.577 [INFO ] [runtime.busevents ] - IRvorneEventLong state updated to ON
  13. 2016-03-08 15:47:18.864 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 10 02 00 00 00 01 ba 8b
  14. 2016-03-08 15:47:18.864 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  15. 2016-03-08 15:47:18.864 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@3b0322af (unit id 16 & transaction 1165). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  16. 2016-03-08 15:47:18.918 [INFO ] [runtime.busevents ] - agsBus16Discrete state updated to CLOSED
  17. 2016-03-08 15:47:19.204 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: f7 03 00 2a 00 0e f1 50
  18. 2016-03-08 15:47:19.204 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  19. 2016-03-08 15:47:19.204 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@def5fd1 (unit id 247 & transaction 1166). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  20. 2016-03-08 15:47:19.256 [INFO ] [runtime.busevents ] - agsBusMasterUptimeSeconds state updated to 22
  21. 2016-03-08 15:47:19.256 [INFO ] [runtime.busevents ] - agsBusMasterErrorsTimeout state updated to 855
  22. 2016-03-08 15:47:19.257 [INFO ] [runtime.busevents ] - agsBusMasterUptimeMinutes state updated to 38
  23. 2016-03-08 15:47:19.257 [INFO ] [runtime.busevents ] - agsBusMasterQueriesToBus state updated to 16679
  24. 2016-03-08 15:47:19.257 [INFO ] [runtime.busevents ] - agsBusMasterSuccessfulTransactions state updated to 5327
  25. 2016-03-08 15:47:19.257 [INFO ] [runtime.busevents ] - agsBusMasterUptimeDays state updated to 32
  26. 2016-03-08 15:47:19.257 [INFO ] [runtime.busevents ] - agsBusMasterErrorsCRC state updated to 844
  27. 2016-03-08 15:47:19.257 [INFO ] [runtime.busevents ] - agsBusMasterPerformanceRS232 state updated to 215
  28. 2016-03-08 15:47:19.257 [INFO ] [runtime.busevents ] - agsBusMasterQueriesToBusMaster state updated to 20750
  29. 2016-03-08 15:47:19.257 [INFO ] [runtime.busevents ] - agsBusMasterTimeoutThreshold state updated to 2500
  30. 2016-03-08 15:47:19.257 [INFO ] [runtime.busevents ] - agsBusMasterPerformanceTotal state updated to 4899
  31. 2016-03-08 15:47:19.257 [INFO ] [runtime.busevents ] - agsBusMasterUptimeHours state updated to 23
  32. 2016-03-08 15:47:19.541 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 03 02 00 00 00 01 b8 28
  33. 2016-03-08 15:47:19.541 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  34. 2016-03-08 15:47:19.541 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@787f0489 (unit id 3 & transaction 1167). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  35. 2016-03-08 15:47:19.632 [INFO ] [runtime.busevents ] - Mitteleingang state updated to CLOSED
  36. 2016-03-08 15:47:19.917 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 10 04 00 00 00 02 72 8a
  37. 2016-03-08 15:47:19.917 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  38. 2016-03-08 15:47:19.917 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputRegistersRequest@10608a9b (unit id 16 & transaction 1168). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  39. 2016-03-08 15:47:19.988 [INFO ] [runtime.busevents ] - agsBus16InputRegister0 state updated to 24774
  40. 2016-03-08 15:47:19.988 [INFO ] [runtime.busevents ] - agsBus16InputRegister1 state updated to 24060
  41. 2016-03-08 15:47:20.274 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 07 01 00 00 00 18 3c 66
  42. 2016-03-08 15:47:20.274 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  43. 2016-03-08 15:47:20.274 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@3254d462 (unit id 7 & transaction 1169). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  44. 2016-03-08 15:47:20.341 [INFO ] [runtime.busevents ] - agsBus7Out0 state updated to ON
  45. 2016-03-08 15:47:20.341 [INFO ] [runtime.busevents ] - agsBus7Out1 state updated to ON
  46. 2016-03-08 15:47:20.341 [INFO ] [runtime.busevents ] - agsBus7Out4 state updated to ON
  47. 2016-03-08 15:47:20.341 [INFO ] [runtime.busevents ] - agsBus7Out5 state updated to OFF
  48. 2016-03-08 15:47:20.341 [INFO ] [runtime.busevents ] - agsBus7Out2 state updated to ON
  49. 2016-03-08 15:47:20.341 [INFO ] [runtime.busevents ] - agsBus7Out3 state updated to ON
  50. 2016-03-08 15:47:20.341 [INFO ] [runtime.busevents ] - agsBus7Out6 state updated to OFF
  51. 2016-03-08 15:47:20.342 [INFO ] [runtime.busevents ] - agsBus7Out7 state updated to OFF
  52. 2016-03-08 15:47:20.342 [INFO ] [runtime.busevents ] - agsBus7EventShortIn2 state updated to ON
  53. 2016-03-08 15:47:20.342 [INFO ] [runtime.busevents ] - agsBus7EventShortIn1 state updated to ON
  54. 2016-03-08 15:47:20.342 [INFO ] [runtime.busevents ] - agsBus7EventShortIn0 state updated to ON
  55. 2016-03-08 15:47:20.342 [INFO ] [runtime.busevents ] - agsBus7EventShortIn6 state updated to ON
  56. 2016-03-08 15:47:20.342 [INFO ] [runtime.busevents ] - agsBus7EventShortIn5 state updated to ON
  57. 2016-03-08 15:47:20.342 [INFO ] [runtime.busevents ] - agsBus7EventShortIn4 state updated to ON
  58. 2016-03-08 15:47:20.342 [INFO ] [runtime.busevents ] - agsBus7EventShortIn3 state updated to ON
  59. 2016-03-08 15:47:20.342 [INFO ] [runtime.busevents ] - agsBus7EventShortIn7 state updated to OFF
  60. 2016-03-08 15:47:20.342 [INFO ] [runtime.busevents ] - agsBus7EventLongIn7 state updated to OFF
  61. 2016-03-08 15:47:20.342 [INFO ] [runtime.busevents ] - agsBus7EventLongIn0 state updated to OFF
  62. 2016-03-08 15:47:20.342 [INFO ] [runtime.busevents ] - agsBus7EventLongIn2 state updated to OFF
  63. 2016-03-08 15:47:20.342 [INFO ] [runtime.busevents ] - agsBus7EventLongIn1 state updated to OFF
  64. 2016-03-08 15:47:20.342 [INFO ] [runtime.busevents ] - agsBus7EventLongIn4 state updated to OFF
  65. 2016-03-08 15:47:20.342 [INFO ] [runtime.busevents ] - agsBus7EventLongIn3 state updated to OFF
  66. 2016-03-08 15:47:20.342 [INFO ] [runtime.busevents ] - agsBus7EventLongIn6 state updated to OFF
  67. 2016-03-08 15:47:20.342 [INFO ] [runtime.busevents ] - agsBus7EventLongIn5 state updated to OFF
  68. 2016-03-08 15:47:20.627 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 0a 01 00 00 00 18 3d 7b
  69. 2016-03-08 15:47:20.627 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  70. 2016-03-08 15:47:20.627 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@4532042e (unit id 10 & transaction 1170). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  71. 2016-03-08 15:47:20.695 [INFO ] [runtime.busevents ] - agsBus10EventLongIn3 state updated to OFF
  72. 2016-03-08 15:47:20.695 [INFO ] [runtime.busevents ] - agsBus10EventLongIn4 state updated to OFF
  73. 2016-03-08 15:47:20.695 [INFO ] [runtime.busevents ] - agsBus10EventLongIn1 state updated to OFF
  74. 2016-03-08 15:47:20.695 [INFO ] [runtime.busevents ] - agsBus10EventLongIn2 state updated to OFF
  75. 2016-03-08 15:47:20.695 [INFO ] [runtime.busevents ] - agsBus10EventLongIn7 state updated to OFF
  76. 2016-03-08 15:47:20.695 [INFO ] [runtime.busevents ] - agsBus10EventLongIn5 state updated to OFF
  77. 2016-03-08 15:47:20.695 [INFO ] [runtime.busevents ] - agsBus10EventLongIn6 state updated to OFF
  78. 2016-03-08 15:47:20.696 [INFO ] [runtime.busevents ] - agsBus10EventLongIn0 state updated to OFF
  79. 2016-03-08 15:47:20.696 [INFO ] [runtime.busevents ] - agsBus10EventShortIn0 state updated to ON
  80. 2016-03-08 15:47:20.696 [INFO ] [runtime.busevents ] - agsBus10EventShortIn6 state updated to ON
  81. 2016-03-08 15:47:20.696 [INFO ] [runtime.busevents ] - agsBus10EventShortIn5 state updated to ON
  82. 2016-03-08 15:47:20.696 [INFO ] [runtime.busevents ] - agsBus10EventShortIn7 state updated to OFF
  83. 2016-03-08 15:47:20.696 [INFO ] [runtime.busevents ] - agsBus10EventShortIn2 state updated to ON
  84. 2016-03-08 15:47:20.696 [INFO ] [runtime.busevents ] - agsBus10EventShortIn1 state updated to ON
  85. 2016-03-08 15:47:20.696 [INFO ] [runtime.busevents ] - agsBus10EventShortIn4 state updated to ON
  86. 2016-03-08 15:47:20.696 [INFO ] [runtime.busevents ] - agsBus10EventShortIn3 state updated to ON
  87. 2016-03-08 15:47:20.696 [INFO ] [runtime.busevents ] - agsBus10Out3 state updated to ON
  88. 2016-03-08 15:47:20.696 [INFO ] [runtime.busevents ] - agsBus10Out2 state updated to OFF
  89. 2016-03-08 15:47:20.696 [INFO ] [runtime.busevents ] - agsBus10Out1 state updated to OFF
  90. 2016-03-08 15:47:20.696 [INFO ] [runtime.busevents ] - agsBus10Out0 state updated to ON
  91. 2016-03-08 15:47:20.696 [INFO ] [runtime.busevents ] - agsBus10Out7 state updated to OFF
  92. 2016-03-08 15:47:20.696 [INFO ] [runtime.busevents ] - agsBus10Out6 state updated to OFF
  93. 2016-03-08 15:47:20.697 [INFO ] [runtime.busevents ] - agsBus10Out5 state updated to ON
  94. 2016-03-08 15:47:20.697 [INFO ] [runtime.busevents ] - agsBus10Out4 state updated to OFF
  95. 2016-03-08 15:47:20.981 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 0c 04 00 00 00 09 31 11
  96. 2016-03-08 15:47:20.981 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  97. 2016-03-08 15:47:20.981 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputRegistersRequest@45e90b4d (unit id 12 & transaction 1171). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  98. 2016-03-08 15:47:21.100 [INFO ] [runtime.busevents ] - agsBus12InputRegister0 state updated to 94
  99. 2016-03-08 15:47:21.101 [INFO ] [runtime.busevents ] - agsBus12InputRegister8 state updated to 23928
  100. 2016-03-08 15:47:21.102 [INFO ] [runtime.busevents ] - agsBus12InputRegister1 state updated to 235
  101. 2016-03-08 15:47:21.103 [INFO ] [runtime.busevents ] - outsideTemp received command 9.40000000
  102. 2016-03-08 15:47:21.104 [INFO ] [runtime.busevents ] - elabTemp received command 23.50000000
  103. 2016-03-08 15:47:21.331 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 09 01 00 00 00 18 3d 48
  104. 2016-03-08 15:47:21.331 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  105. 2016-03-08 15:47:21.331 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@51496539 (unit id 9 & transaction 1172). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  106. 2016-03-08 15:47:21.396 [INFO ] [runtime.busevents ] - agsBus9Out6 state updated to OFF
  107. 2016-03-08 15:47:21.396 [INFO ] [runtime.busevents ] - agsBus9Out7 state updated to OFF
  108. 2016-03-08 15:47:21.396 [INFO ] [runtime.busevents ] - agsBus9Out4 state updated to OFF
  109. 2016-03-08 15:47:21.396 [INFO ] [runtime.busevents ] - agsBus9Out5 state updated to OFF
  110. 2016-03-08 15:47:21.396 [INFO ] [runtime.busevents ] - agsBus9Out2 state updated to ON
  111. 2016-03-08 15:47:21.396 [INFO ] [runtime.busevents ] - agsBus9Out3 state updated to OFF
  112. 2016-03-08 15:47:21.397 [INFO ] [runtime.busevents ] - agsBus9Out0 state updated to ON
  113. 2016-03-08 15:47:21.397 [INFO ] [runtime.busevents ] - agsBus9Out1 state updated to OFF
  114. 2016-03-08 15:47:21.397 [INFO ] [runtime.busevents ] - agsBus9EventShortIn7 state updated to OFF
  115. 2016-03-08 15:47:21.397 [INFO ] [runtime.busevents ] - agsBus9EventShortIn5 state updated to OFF
  116. 2016-03-08 15:47:21.397 [INFO ] [runtime.busevents ] - agsBus9EventShortIn6 state updated to OFF
  117. 2016-03-08 15:47:21.397 [INFO ] [runtime.busevents ] - agsBus9EventShortIn3 state updated to ON
  118. 2016-03-08 15:47:21.397 [INFO ] [runtime.busevents ] - agsBus9EventShortIn4 state updated to ON
  119. 2016-03-08 15:47:21.397 [INFO ] [runtime.busevents ] - agsBus9EventShortIn1 state updated to ON
  120. 2016-03-08 15:47:21.397 [INFO ] [runtime.busevents ] - agsBus9EventShortIn2 state updated to ON
  121. 2016-03-08 15:47:21.397 [INFO ] [runtime.busevents ] - agsBus9EventShortIn0 state updated to ON
  122. 2016-03-08 15:47:21.397 [INFO ] [runtime.busevents ] - agsBus9EventLongIn7 state updated to OFF
  123. 2016-03-08 15:47:21.397 [INFO ] [runtime.busevents ] - agsBus9EventLongIn6 state updated to OFF
  124. 2016-03-08 15:47:21.397 [INFO ] [runtime.busevents ] - agsBus9EventLongIn5 state updated to OFF
  125. 2016-03-08 15:47:21.397 [INFO ] [runtime.busevents ] - agsBus9EventLongIn4 state updated to OFF
  126. 2016-03-08 15:47:21.397 [INFO ] [runtime.busevents ] - agsBus9EventLongIn3 state updated to OFF
  127. 2016-03-08 15:47:21.397 [INFO ] [runtime.busevents ] - agsBus9EventLongIn2 state updated to OFF
  128. 2016-03-08 15:47:21.397 [INFO ] [runtime.busevents ] - agsBus9EventLongIn1 state updated to OFF
  129. 2016-03-08 15:47:21.397 [INFO ] [runtime.busevents ] - agsBus9EventLongIn0 state updated to OFF
  130. 2016-03-08 15:47:21.681 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 08 01 00 00 00 18 3c 99
  131. 2016-03-08 15:47:21.681 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  132. 2016-03-08 15:47:21.681 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@45aa4cb6 (unit id 8 & transaction 1173). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  133. 2016-03-08 15:47:21.778 [INFO ] [runtime.busevents ] - agsBus8Out0 state updated to ON
  134. 2016-03-08 15:47:21.778 [INFO ] [runtime.busevents ] - agsBus8Out1 state updated to ON
  135. 2016-03-08 15:47:21.779 [INFO ] [runtime.busevents ] - agsBus8Out2 state updated to OFF
  136. 2016-03-08 15:47:21.779 [INFO ] [runtime.busevents ] - agsBus8Out3 state updated to ON
  137. 2016-03-08 15:47:21.779 [INFO ] [runtime.busevents ] - agsBus8Out4 state updated to ON
  138. 2016-03-08 15:47:21.779 [INFO ] [runtime.busevents ] - agsBus8Out5 state updated to ON
  139. 2016-03-08 15:47:21.779 [INFO ] [runtime.busevents ] - agsBus8Out6 state updated to OFF
  140. 2016-03-08 15:47:21.779 [INFO ] [runtime.busevents ] - agsBus8Out7 state updated to OFF
  141. 2016-03-08 15:47:21.779 [INFO ] [runtime.busevents ] - agsBus8EventShortIn0 state updated to ON
  142. 2016-03-08 15:47:21.779 [INFO ] [runtime.busevents ] - agsBus8EventShortIn1 state updated to ON
  143. 2016-03-08 15:47:21.779 [INFO ] [runtime.busevents ] - agsBus8EventShortIn2 state updated to ON
  144. 2016-03-08 15:47:21.779 [INFO ] [runtime.busevents ] - agsBus8EventShortIn3 state updated to ON
  145. 2016-03-08 15:47:21.779 [INFO ] [runtime.busevents ] - agsBus8EventShortIn4 state updated to ON
  146. 2016-03-08 15:47:21.779 [INFO ] [runtime.busevents ] - agsBus8EventShortIn5 state updated to ON
  147. 2016-03-08 15:47:21.779 [INFO ] [runtime.busevents ] - agsBus8EventShortIn6 state updated to ON
  148. 2016-03-08 15:47:21.779 [INFO ] [runtime.busevents ] - agsBus8EventShortIn7 state updated to OFF
  149. 2016-03-08 15:47:21.779 [INFO ] [runtime.busevents ] - agsBus8EventLongIn6 state updated to OFF
  150. 2016-03-08 15:47:21.779 [INFO ] [runtime.busevents ] - agsBus8EventLongIn7 state updated to OFF
  151. 2016-03-08 15:47:21.780 [INFO ] [runtime.busevents ] - agsBus8EventLongIn2 state updated to OFF
  152. 2016-03-08 15:47:21.780 [INFO ] [runtime.busevents ] - agsBus8EventLongIn3 state updated to OFF
  153. 2016-03-08 15:47:21.780 [INFO ] [runtime.busevents ] - agsBus8EventLongIn4 state updated to OFF
  154. 2016-03-08 15:47:21.780 [INFO ] [runtime.busevents ] - agsBus8EventLongIn5 state updated to OFF
  155. 2016-03-08 15:47:21.780 [INFO ] [runtime.busevents ] - agsBus8EventLongIn0 state updated to OFF
  156. 2016-03-08 15:47:21.780 [INFO ] [runtime.busevents ] - agsBus8EventLongIn1 state updated to OFF
  157. 2016-03-08 15:47:21.861 [INFO ] [runtime.busevents ] - agsBus17Discrete state updated to CLOSED
  158. 2016-03-08 15:47:21.885 [INFO ] [runtime.busevents ] - Holztuer state updated to CLOSED
  159. 2016-03-08 15:47:21.921 [INFO ] [runtime.busevents ] - Hintereingang state updated to CLOSED
  160. 2016-03-08 15:47:21.987 [INFO ] [runtime.busevents ] - agsBus17InputRegister1 state updated to 24144
  161. 2016-03-08 15:47:21.987 [INFO ] [runtime.busevents ] - agsBus17InputRegister0 state updated to 24732
  162. 2016-03-08 15:47:22.274 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 05 02 00 00 00 08 78 48
  163. 2016-03-08 15:47:22.274 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  164. 2016-03-08 15:47:22.274 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@10ec3359 (unit id 5 & transaction 1178). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  165. 2016-03-08 15:47:22.340 [INFO ] [runtime.busevents ] - IRvorne state updated to CLOSED
  166. 2016-03-08 15:47:22.340 [INFO ] [runtime.busevents ] - Kloschluessel state updated to OPEN
  167. 2016-03-08 15:47:22.340 [INFO ] [runtime.busevents ] - Klingel state updated to CLOSED
  168. 2016-03-08 15:47:22.340 [INFO ] [runtime.busevents ] - Stahltuer state updated to OPEN
  169. 2016-03-08 15:47:22.341 [INFO ] [runtime.busevents ] - agsBus7Out5 received command OFF
  170. 2016-03-08 15:47:22.341 [INFO ] [runtime.busevents ] - agsBus7Out4 received command ON
  171. 2016-03-08 15:47:22.624 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 0b 01 00 00 00 18 3c aa
  172. 2016-03-08 15:47:22.624 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  173. 2016-03-08 15:47:22.624 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@1d52f16a (unit id 11 & transaction 1179). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  174. 2016-03-08 15:47:22.693 [INFO ] [runtime.busevents ] - agsBus11Out0 state updated to OFF
  175. 2016-03-08 15:47:22.693 [INFO ] [runtime.busevents ] - agsBus11Out2 state updated to ON
  176. 2016-03-08 15:47:22.693 [INFO ] [runtime.busevents ] - agsBus11Out1 state updated to ON
  177. 2016-03-08 15:47:22.694 [INFO ] [runtime.busevents ] - agsBus11Out4 state updated to OFF
  178. 2016-03-08 15:47:22.694 [INFO ] [runtime.busevents ] - agsBus11Out3 state updated to OFF
  179. 2016-03-08 15:47:22.694 [INFO ] [runtime.busevents ] - agsBus11Out6 state updated to OFF
  180. 2016-03-08 15:47:22.694 [INFO ] [runtime.busevents ] - agsBus11Out5 state updated to OFF
  181. 2016-03-08 15:47:22.694 [INFO ] [runtime.busevents ] - agsBus11Out7 state updated to OFF
  182. 2016-03-08 15:47:22.694 [INFO ] [runtime.busevents ] - agsBus11EventShortIn0 state updated to ON
  183. 2016-03-08 15:47:22.694 [INFO ] [runtime.busevents ] - agsBus11EventShortIn1 state updated to ON
  184. 2016-03-08 15:47:22.694 [INFO ] [runtime.busevents ] - agsBus11EventShortIn4 state updated to ON
  185. 2016-03-08 15:47:22.694 [INFO ] [runtime.busevents ] - agsBus11EventShortIn5 state updated to ON
  186. 2016-03-08 15:47:22.694 [INFO ] [runtime.busevents ] - agsBus11EventShortIn2 state updated to ON
  187. 2016-03-08 15:47:22.694 [INFO ] [runtime.busevents ] - agsBus11EventShortIn3 state updated to ON
  188. 2016-03-08 15:47:22.694 [INFO ] [runtime.busevents ] - agsBus11EventShortIn6 state updated to ON
  189. 2016-03-08 15:47:22.694 [INFO ] [runtime.busevents ] - agsBus11EventShortIn7 state updated to OFF
  190. 2016-03-08 15:47:22.694 [INFO ] [runtime.busevents ] - agsBus11EventLongIn5 state updated to OFF
  191. 2016-03-08 15:47:22.694 [INFO ] [runtime.busevents ] - agsBus11EventLongIn4 state updated to OFF
  192. 2016-03-08 15:47:22.694 [INFO ] [runtime.busevents ] - agsBus11EventLongIn7 state updated to OFF
  193. 2016-03-08 15:47:22.695 [INFO ] [runtime.busevents ] - agsBus11EventLongIn6 state updated to OFF
  194. 2016-03-08 15:47:22.695 [INFO ] [runtime.busevents ] - agsBus11EventLongIn1 state updated to OFF
  195. 2016-03-08 15:47:22.695 [INFO ] [runtime.busevents ] - agsBus11EventLongIn0 state updated to OFF
  196. 2016-03-08 15:47:22.695 [INFO ] [runtime.busevents ] - agsBus11EventLongIn3 state updated to OFF
  197. 2016-03-08 15:47:22.695 [INFO ] [runtime.busevents ] - agsBus11EventLongIn2 state updated to OFF
  198. 2016-03-08 15:47:22.977 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: f7 01 00 2a 00 05 c9 57
  199. 2016-03-08 15:47:22.977 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  200. 2016-03-08 15:47:22.977 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@7a82f54 (unit id 247 & transaction 1180). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  201. 2016-03-08 15:47:23.035 [INFO ] [runtime.busevents ] - agsBusMasterControlDoors state updated to ON
  202. 2016-03-08 15:47:23.035 [INFO ] [runtime.busevents ] - agsBusMasterControlMasterSwitchOn state updated to ON
  203. 2016-03-08 15:47:23.035 [INFO ] [runtime.busevents ] - agsBusMasterControlMasterSwitchOff state updated to ON
  204. 2016-03-08 15:47:23.321 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 05 01 00 00 00 28 3d 90
  205. 2016-03-08 15:47:23.321 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  206. 2016-03-08 15:47:23.321 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@10f01ceb (unit id 5 & transaction 1181). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  207. 2016-03-08 15:47:23.379 [INFO ] [runtime.busevents ] - IRvorneEventShort state updated to OFF
  208. 2016-03-08 15:47:23.379 [INFO ] [runtime.busevents ] - IRvorneEventRisingEdge state updated to OFF
  209. 2016-03-08 15:47:23.379 [INFO ] [runtime.busevents ] - IRvorneEventLong state updated to ON
  210. 2016-03-08 15:47:23.664 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 10 02 00 00 00 01 ba 8b
  211. 2016-03-08 15:47:23.664 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  212. 2016-03-08 15:47:23.664 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@61778357 (unit id 16 & transaction 1182). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  213. 2016-03-08 15:47:23.720 [INFO ] [runtime.busevents ] - agsBus16Discrete state updated to CLOSED
  214. 2016-03-08 15:47:24.004 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: f7 03 00 2a 00 0e f1 50
  215. 2016-03-08 15:47:24.004 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  216. 2016-03-08 15:47:24.004 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@6ba4f7b2 (unit id 247 & transaction 1183). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  217. 2016-03-08 15:47:24.057 [INFO ] [runtime.busevents ] - agsBusMasterUptimeSeconds state updated to 27
  218. 2016-03-08 15:47:24.057 [INFO ] [runtime.busevents ] - agsBusMasterErrorsTimeout state updated to 855
  219. 2016-03-08 15:47:24.057 [INFO ] [runtime.busevents ] - agsBusMasterUptimeMinutes state updated to 38
  220. 2016-03-08 15:47:24.057 [INFO ] [runtime.busevents ] - agsBusMasterQueriesToBus state updated to 16694
  221. 2016-03-08 15:47:24.057 [INFO ] [runtime.busevents ] - agsBusMasterSuccessfulTransactions state updated to 5719
  222. 2016-03-08 15:47:24.057 [INFO ] [runtime.busevents ] - agsBusMasterUptimeDays state updated to 32
  223. 2016-03-08 15:47:24.057 [INFO ] [runtime.busevents ] - agsBusMasterErrorsCRC state updated to 844
  224. 2016-03-08 15:47:24.057 [INFO ] [runtime.busevents ] - agsBusMasterPerformanceRS232 state updated to 215
  225. 2016-03-08 15:47:24.057 [INFO ] [runtime.busevents ] - agsBusMasterQueriesToBusMaster state updated to 20752
  226. 2016-03-08 15:47:24.057 [INFO ] [runtime.busevents ] - agsBusMasterTimeoutThreshold state updated to 2500
  227. 2016-03-08 15:47:24.057 [INFO ] [runtime.busevents ] - agsBusMasterPerformanceTotal state updated to 4899
  228. 2016-03-08 15:47:24.058 [INFO ] [runtime.busevents ] - agsBusMasterUptimeHours state updated to 23
  229. 2016-03-08 15:47:24.340 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 03 02 00 00 00 01 b8 28
  230. 2016-03-08 15:47:24.340 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  231. 2016-03-08 15:47:24.341 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@2d30a71d (unit id 3 & transaction 1184). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  232. 2016-03-08 15:47:24.432 [INFO ] [runtime.busevents ] - Mitteleingang state updated to CLOSED
  233. 2016-03-08 15:47:24.717 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 10 04 00 00 00 02 72 8a
  234. 2016-03-08 15:47:24.717 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  235. 2016-03-08 15:47:24.717 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputRegistersRequest@3d37f114 (unit id 16 & transaction 1185). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  236. 2016-03-08 15:47:24.787 [INFO ] [runtime.busevents ] - agsBus16InputRegister0 state updated to 24774
  237. 2016-03-08 15:47:24.787 [INFO ] [runtime.busevents ] - agsBus16InputRegister1 state updated to 24060
  238. 2016-03-08 15:47:25.071 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 07 01 00 00 00 18 3c 66
  239. 2016-03-08 15:47:25.071 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  240. 2016-03-08 15:47:25.071 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@6087a0de (unit id 7 & transaction 1186). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  241. 2016-03-08 15:47:25.139 [INFO ] [runtime.busevents ] - agsBus7Out0 state updated to ON
  242. 2016-03-08 15:47:25.139 [INFO ] [runtime.busevents ] - agsBus7Out1 state updated to ON
  243. 2016-03-08 15:47:25.139 [INFO ] [runtime.busevents ] - agsBus7Out4 state updated to ON
  244. 2016-03-08 15:47:25.139 [INFO ] [runtime.busevents ] - agsBus7Out5 state updated to OFF
  245. 2016-03-08 15:47:25.140 [INFO ] [runtime.busevents ] - agsBus7Out2 state updated to ON
  246. 2016-03-08 15:47:25.140 [INFO ] [runtime.busevents ] - agsBus7Out3 state updated to ON
  247. 2016-03-08 15:47:25.140 [INFO ] [runtime.busevents ] - agsBus7Out6 state updated to OFF
  248. 2016-03-08 15:47:25.140 [INFO ] [runtime.busevents ] - agsBus7Out7 state updated to OFF
  249. 2016-03-08 15:47:25.140 [INFO ] [runtime.busevents ] - agsBus7EventShortIn2 state updated to ON
  250. 2016-03-08 15:47:25.140 [INFO ] [runtime.busevents ] - agsBus7EventShortIn1 state updated to ON
  251. 2016-03-08 15:47:25.140 [INFO ] [runtime.busevents ] - agsBus7EventShortIn0 state updated to ON
  252. 2016-03-08 15:47:25.140 [INFO ] [runtime.busevents ] - agsBus7EventShortIn6 state updated to ON
  253. 2016-03-08 15:47:25.140 [INFO ] [runtime.busevents ] - agsBus7EventShortIn5 state updated to ON
  254. 2016-03-08 15:47:25.140 [INFO ] [runtime.busevents ] - agsBus7EventShortIn4 state updated to ON
  255. 2016-03-08 15:47:25.140 [INFO ] [runtime.busevents ] - agsBus7EventShortIn3 state updated to ON
  256. 2016-03-08 15:47:25.140 [INFO ] [runtime.busevents ] - agsBus7EventShortIn7 state updated to OFF
  257. 2016-03-08 15:47:25.140 [INFO ] [runtime.busevents ] - agsBus7EventLongIn7 state updated to OFF
  258. 2016-03-08 15:47:25.140 [INFO ] [runtime.busevents ] - agsBus7EventLongIn0 state updated to OFF
  259. 2016-03-08 15:47:25.140 [INFO ] [runtime.busevents ] - agsBus7EventLongIn2 state updated to OFF
  260. 2016-03-08 15:47:25.140 [INFO ] [runtime.busevents ] - agsBus7EventLongIn1 state updated to OFF
  261. 2016-03-08 15:47:25.140 [INFO ] [runtime.busevents ] - agsBus7EventLongIn4 state updated to OFF
  262. 2016-03-08 15:47:25.141 [INFO ] [runtime.busevents ] - agsBus7EventLongIn3 state updated to OFF
  263. 2016-03-08 15:47:25.141 [INFO ] [runtime.busevents ] - agsBus7EventLongIn6 state updated to OFF
  264. 2016-03-08 15:47:25.141 [INFO ] [runtime.busevents ] - agsBus7EventLongIn5 state updated to OFF
  265. 2016-03-08 15:47:25.424 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 0a 01 00 00 00 18 3d 7b
  266. 2016-03-08 15:47:25.424 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  267. 2016-03-08 15:47:25.424 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@2cd2c21b (unit id 10 & transaction 1187). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  268. 2016-03-08 15:47:25.493 [INFO ] [runtime.busevents ] - agsBus10EventLongIn3 state updated to OFF
  269. 2016-03-08 15:47:25.493 [INFO ] [runtime.busevents ] - agsBus10EventLongIn4 state updated to OFF
  270. 2016-03-08 15:47:25.493 [INFO ] [runtime.busevents ] - agsBus10EventLongIn1 state updated to OFF
  271. 2016-03-08 15:47:25.493 [INFO ] [runtime.busevents ] - agsBus10EventLongIn2 state updated to OFF
  272. 2016-03-08 15:47:25.493 [INFO ] [runtime.busevents ] - agsBus10EventLongIn7 state updated to OFF
  273. 2016-03-08 15:47:25.493 [INFO ] [runtime.busevents ] - agsBus10EventLongIn5 state updated to OFF
  274. 2016-03-08 15:47:25.493 [INFO ] [runtime.busevents ] - agsBus10EventLongIn6 state updated to OFF
  275. 2016-03-08 15:47:25.493 [INFO ] [runtime.busevents ] - agsBus10EventLongIn0 state updated to OFF
  276. 2016-03-08 15:47:25.493 [INFO ] [runtime.busevents ] - agsBus10EventShortIn0 state updated to ON
  277. 2016-03-08 15:47:25.494 [INFO ] [runtime.busevents ] - agsBus10EventShortIn6 state updated to ON
  278. 2016-03-08 15:47:25.494 [INFO ] [runtime.busevents ] - agsBus10EventShortIn5 state updated to ON
  279. 2016-03-08 15:47:25.494 [INFO ] [runtime.busevents ] - agsBus10EventShortIn7 state updated to OFF
  280. 2016-03-08 15:47:25.494 [INFO ] [runtime.busevents ] - agsBus10EventShortIn2 state updated to ON
  281. 2016-03-08 15:47:25.494 [INFO ] [runtime.busevents ] - agsBus10EventShortIn1 state updated to ON
  282. 2016-03-08 15:47:25.494 [INFO ] [runtime.busevents ] - agsBus10EventShortIn4 state updated to ON
  283. 2016-03-08 15:47:25.494 [INFO ] [runtime.busevents ] - agsBus10EventShortIn3 state updated to ON
  284. 2016-03-08 15:47:25.494 [INFO ] [runtime.busevents ] - agsBus10Out3 state updated to ON
  285. 2016-03-08 15:47:25.494 [INFO ] [runtime.busevents ] - agsBus10Out2 state updated to OFF
  286. 2016-03-08 15:47:25.494 [INFO ] [runtime.busevents ] - agsBus10Out1 state updated to OFF
  287. 2016-03-08 15:47:25.494 [INFO ] [runtime.busevents ] - agsBus10Out0 state updated to ON
  288. 2016-03-08 15:47:25.494 [INFO ] [runtime.busevents ] - agsBus10Out7 state updated to OFF
  289. 2016-03-08 15:47:25.494 [INFO ] [runtime.busevents ] - agsBus10Out6 state updated to OFF
  290. 2016-03-08 15:47:25.494 [INFO ] [runtime.busevents ] - agsBus10Out5 state updated to ON
  291. 2016-03-08 15:47:25.494 [INFO ] [runtime.busevents ] - agsBus10Out4 state updated to OFF
  292. 2016-03-08 15:47:25.777 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 0c 04 00 00 00 09 31 11
  293. 2016-03-08 15:47:25.777 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  294. 2016-03-08 15:47:25.777 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputRegistersRequest@47290d3 (unit id 12 & transaction 1188). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  295. 2016-03-08 15:47:25.898 [INFO ] [runtime.busevents ] - agsBus12InputRegister0 state updated to 93
  296. 2016-03-08 15:47:25.898 [INFO ] [runtime.busevents ] - agsBus12InputRegister8 state updated to 23808
  297. 2016-03-08 15:47:25.898 [INFO ] [runtime.busevents ] - agsBus12InputRegister1 state updated to 234
  298. 2016-03-08 15:47:25.899 [INFO ] [runtime.busevents ] - outsideTemp received command 9.30000000
  299. 2016-03-08 15:47:25.900 [INFO ] [runtime.busevents ] - elabTemp received command 23.40000000
  300. 2016-03-08 15:47:26.131 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 09 01 00 00 00 18 3d 48
  301. 2016-03-08 15:47:26.131 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  302. 2016-03-08 15:47:26.131 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@64f7e18 (unit id 9 & transaction 1189). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  303. 2016-03-08 15:47:26.194 [INFO ] [runtime.busevents ] - agsBus9Out6 state updated to OFF
  304. 2016-03-08 15:47:26.194 [INFO ] [runtime.busevents ] - agsBus9Out7 state updated to OFF
  305. 2016-03-08 15:47:26.194 [INFO ] [runtime.busevents ] - agsBus9Out4 state updated to OFF
  306. 2016-03-08 15:47:26.194 [INFO ] [runtime.busevents ] - agsBus9Out5 state updated to OFF
  307. 2016-03-08 15:47:26.194 [INFO ] [runtime.busevents ] - agsBus9Out2 state updated to ON
  308. 2016-03-08 15:47:26.194 [INFO ] [runtime.busevents ] - agsBus9Out3 state updated to OFF
  309. 2016-03-08 15:47:26.195 [INFO ] [runtime.busevents ] - agsBus9Out0 state updated to ON
  310. 2016-03-08 15:47:26.195 [INFO ] [runtime.busevents ] - agsBus9Out1 state updated to OFF
  311. 2016-03-08 15:47:26.195 [INFO ] [runtime.busevents ] - agsBus9EventShortIn7 state updated to OFF
  312. 2016-03-08 15:47:26.195 [INFO ] [runtime.busevents ] - agsBus9EventShortIn5 state updated to OFF
  313. 2016-03-08 15:47:26.195 [INFO ] [runtime.busevents ] - agsBus9EventShortIn6 state updated to OFF
  314. 2016-03-08 15:47:26.195 [INFO ] [runtime.busevents ] - agsBus9EventShortIn3 state updated to ON
  315. 2016-03-08 15:47:26.195 [INFO ] [runtime.busevents ] - agsBus9EventShortIn4 state updated to ON
  316. 2016-03-08 15:47:26.195 [INFO ] [runtime.busevents ] - agsBus9EventShortIn1 state updated to ON
  317. 2016-03-08 15:47:26.195 [INFO ] [runtime.busevents ] - agsBus9EventShortIn2 state updated to ON
  318. 2016-03-08 15:47:26.195 [INFO ] [runtime.busevents ] - agsBus9EventShortIn0 state updated to ON
  319. 2016-03-08 15:47:26.195 [INFO ] [runtime.busevents ] - agsBus9EventLongIn7 state updated to OFF
  320. 2016-03-08 15:47:26.195 [INFO ] [runtime.busevents ] - agsBus9EventLongIn6 state updated to OFF
  321. 2016-03-08 15:47:26.195 [INFO ] [runtime.busevents ] - agsBus9EventLongIn5 state updated to OFF
  322. 2016-03-08 15:47:26.195 [INFO ] [runtime.busevents ] - agsBus9EventLongIn4 state updated to OFF
  323. 2016-03-08 15:47:26.195 [INFO ] [runtime.busevents ] - agsBus9EventLongIn3 state updated to OFF
  324. 2016-03-08 15:47:26.195 [INFO ] [runtime.busevents ] - agsBus9EventLongIn2 state updated to OFF
  325. 2016-03-08 15:47:26.195 [INFO ] [runtime.busevents ] - agsBus9EventLongIn1 state updated to OFF
  326. 2016-03-08 15:47:26.196 [INFO ] [runtime.busevents ] - agsBus9EventLongIn0 state updated to OFF
  327. 2016-03-08 15:47:26.481 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 08 01 00 00 00 18 3c 99
  328. 2016-03-08 15:47:26.481 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  329. 2016-03-08 15:47:26.481 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@5b13bf5f (unit id 8 & transaction 1190). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  330. 2016-03-08 15:47:26.576 [INFO ] [runtime.busevents ] - agsBus8Out0 state updated to ON
  331. 2016-03-08 15:47:26.577 [INFO ] [runtime.busevents ] - agsBus8Out1 state updated to ON
  332. 2016-03-08 15:47:26.577 [INFO ] [runtime.busevents ] - agsBus8Out2 state updated to OFF
  333. 2016-03-08 15:47:26.577 [INFO ] [runtime.busevents ] - agsBus8Out3 state updated to ON
  334. 2016-03-08 15:47:26.577 [INFO ] [runtime.busevents ] - agsBus8Out4 state updated to ON
  335. 2016-03-08 15:47:26.577 [INFO ] [runtime.busevents ] - agsBus8Out5 state updated to ON
  336. 2016-03-08 15:47:26.577 [INFO ] [runtime.busevents ] - agsBus8Out6 state updated to OFF
  337. 2016-03-08 15:47:26.577 [INFO ] [runtime.busevents ] - agsBus8Out7 state updated to OFF
  338. 2016-03-08 15:47:26.577 [INFO ] [runtime.busevents ] - agsBus8EventShortIn0 state updated to ON
  339. 2016-03-08 15:47:26.577 [INFO ] [runtime.busevents ] - agsBus8EventShortIn1 state updated to ON
  340. 2016-03-08 15:47:26.577 [INFO ] [runtime.busevents ] - agsBus8EventShortIn2 state updated to ON
  341. 2016-03-08 15:47:26.577 [INFO ] [runtime.busevents ] - agsBus8EventShortIn3 state updated to ON
  342. 2016-03-08 15:47:26.577 [INFO ] [runtime.busevents ] - agsBus8EventShortIn4 state updated to ON
  343. 2016-03-08 15:47:26.577 [INFO ] [runtime.busevents ] - agsBus8EventShortIn5 state updated to ON
  344. 2016-03-08 15:47:26.577 [INFO ] [runtime.busevents ] - agsBus8EventShortIn6 state updated to ON
  345. 2016-03-08 15:47:26.577 [INFO ] [runtime.busevents ] - agsBus8EventShortIn7 state updated to OFF
  346. 2016-03-08 15:47:26.578 [INFO ] [runtime.busevents ] - agsBus8EventLongIn6 state updated to OFF
  347. 2016-03-08 15:47:26.578 [INFO ] [runtime.busevents ] - agsBus8EventLongIn7 state updated to OFF
  348. 2016-03-08 15:47:26.578 [INFO ] [runtime.busevents ] - agsBus8EventLongIn2 state updated to OFF
  349. 2016-03-08 15:47:26.578 [INFO ] [runtime.busevents ] - agsBus8EventLongIn3 state updated to OFF
  350. 2016-03-08 15:47:26.578 [INFO ] [runtime.busevents ] - agsBus8EventLongIn4 state updated to OFF
  351. 2016-03-08 15:47:26.578 [INFO ] [runtime.busevents ] - agsBus8EventLongIn5 state updated to OFF
  352. 2016-03-08 15:47:26.578 [INFO ] [runtime.busevents ] - agsBus8EventLongIn0 state updated to OFF
  353. 2016-03-08 15:47:26.578 [INFO ] [runtime.busevents ] - agsBus8EventLongIn1 state updated to OFF
  354. 2016-03-08 15:47:26.659 [INFO ] [runtime.busevents ] - agsBus17Discrete state updated to CLOSED
  355. 2016-03-08 15:47:26.683 [INFO ] [runtime.busevents ] - Holztuer state updated to CLOSED
  356. 2016-03-08 15:47:26.720 [INFO ] [runtime.busevents ] - Hintereingang state updated to CLOSED
  357. 2016-03-08 15:47:26.785 [INFO ] [runtime.busevents ] - agsBus17InputRegister1 state updated to 24165
  358. 2016-03-08 15:47:26.785 [INFO ] [runtime.busevents ] - agsBus17InputRegister0 state updated to 24711
  359. 2016-03-08 15:47:27.071 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 05 02 00 00 00 08 78 48
  360. 2016-03-08 15:47:27.071 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  361. 2016-03-08 15:47:27.071 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@61eb6c3c (unit id 5 & transaction 1195). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  362. 2016-03-08 15:47:27.137 [INFO ] [runtime.busevents ] - IRvorne state updated to CLOSED
  363. 2016-03-08 15:47:27.138 [INFO ] [runtime.busevents ] - Kloschluessel state updated to OPEN
  364. 2016-03-08 15:47:27.138 [INFO ] [runtime.busevents ] - Klingel state updated to CLOSED
  365. 2016-03-08 15:47:27.138 [INFO ] [runtime.busevents ] - Stahltuer state updated to OPEN
  366. 2016-03-08 15:47:27.139 [INFO ] [runtime.busevents ] - agsBus7Out5 received command OFF
  367. 2016-03-08 15:47:27.140 [INFO ] [runtime.busevents ] - agsBus7Out4 received command ON
  368. 2016-03-08 15:47:27.424 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 0b 01 00 00 00 18 3c aa
  369. 2016-03-08 15:47:27.424 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  370. 2016-03-08 15:47:27.424 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@718f9cda (unit id 11 & transaction 1196). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  371. 2016-03-08 15:47:27.491 [INFO ] [runtime.busevents ] - agsBus11Out0 state updated to OFF
  372. 2016-03-08 15:47:27.491 [INFO ] [runtime.busevents ] - agsBus11Out2 state updated to ON
  373. 2016-03-08 15:47:27.491 [INFO ] [runtime.busevents ] - agsBus11Out1 state updated to ON
  374. 2016-03-08 15:47:27.491 [INFO ] [runtime.busevents ] - agsBus11Out4 state updated to OFF
  375. 2016-03-08 15:47:27.491 [INFO ] [runtime.busevents ] - agsBus11Out3 state updated to OFF
  376. 2016-03-08 15:47:27.491 [INFO ] [runtime.busevents ] - agsBus11Out6 state updated to OFF
  377. 2016-03-08 15:47:27.491 [INFO ] [runtime.busevents ] - agsBus11Out5 state updated to OFF
  378. 2016-03-08 15:47:27.491 [INFO ] [runtime.busevents ] - agsBus11Out7 state updated to OFF
  379. 2016-03-08 15:47:27.491 [INFO ] [runtime.busevents ] - agsBus11EventShortIn0 state updated to ON
  380. 2016-03-08 15:47:27.491 [INFO ] [runtime.busevents ] - agsBus11EventShortIn1 state updated to ON
  381. 2016-03-08 15:47:27.491 [INFO ] [runtime.busevents ] - agsBus11EventShortIn4 state updated to ON
  382. 2016-03-08 15:47:27.491 [INFO ] [runtime.busevents ] - agsBus11EventShortIn5 state updated to ON
  383. 2016-03-08 15:47:27.491 [INFO ] [runtime.busevents ] - agsBus11EventShortIn2 state updated to ON
  384. 2016-03-08 15:47:27.491 [INFO ] [runtime.busevents ] - agsBus11EventShortIn3 state updated to ON
  385. 2016-03-08 15:47:27.492 [INFO ] [runtime.busevents ] - agsBus11EventShortIn6 state updated to ON
  386. 2016-03-08 15:47:27.492 [INFO ] [runtime.busevents ] - agsBus11EventShortIn7 state updated to OFF
  387. 2016-03-08 15:47:27.492 [INFO ] [runtime.busevents ] - agsBus11EventLongIn5 state updated to OFF
  388. 2016-03-08 15:47:27.492 [INFO ] [runtime.busevents ] - agsBus11EventLongIn4 state updated to OFF
  389. 2016-03-08 15:47:27.492 [INFO ] [runtime.busevents ] - agsBus11EventLongIn7 state updated to OFF
  390. 2016-03-08 15:47:27.492 [INFO ] [runtime.busevents ] - agsBus11EventLongIn6 state updated to OFF
  391. 2016-03-08 15:47:27.492 [INFO ] [runtime.busevents ] - agsBus11EventLongIn1 state updated to OFF
  392. 2016-03-08 15:47:27.492 [INFO ] [runtime.busevents ] - agsBus11EventLongIn0 state updated to OFF
  393. 2016-03-08 15:47:27.492 [INFO ] [runtime.busevents ] - agsBus11EventLongIn3 state updated to OFF
  394. 2016-03-08 15:47:27.492 [INFO ] [runtime.busevents ] - agsBus11EventLongIn2 state updated to OFF
  395. 2016-03-08 15:47:27.777 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: f7 01 00 2a 00 05 c9 57
  396. 2016-03-08 15:47:27.777 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  397. 2016-03-08 15:47:27.777 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@ccd834d (unit id 247 & transaction 1197). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  398. 2016-03-08 15:47:27.832 [INFO ] [runtime.busevents ] - agsBusMasterControlDoors state updated to ON
  399. 2016-03-08 15:47:27.832 [INFO ] [runtime.busevents ] - agsBusMasterControlMasterSwitchOn state updated to ON
  400. 2016-03-08 15:47:27.832 [INFO ] [runtime.busevents ] - agsBusMasterControlMasterSwitchOff state updated to ON
  401. 2016-03-08 15:47:28.117 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 05 01 00 00 00 28 3d 90
  402. 2016-03-08 15:47:28.117 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  403. 2016-03-08 15:47:28.117 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@4ae22ccc (unit id 5 & transaction 1198). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  404. 2016-03-08 15:47:28.176 [INFO ] [runtime.busevents ] - IRvorneEventShort state updated to OFF
  405. 2016-03-08 15:47:28.177 [INFO ] [runtime.busevents ] - IRvorneEventRisingEdge state updated to OFF
  406. 2016-03-08 15:47:28.177 [INFO ] [runtime.busevents ] - IRvorneEventLong state updated to ON
  407. 2016-03-08 15:47:28.461 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 10 02 00 00 00 01 ba 8b
  408. 2016-03-08 15:47:28.461 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  409. 2016-03-08 15:47:28.461 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@70523320 (unit id 16 & transaction 1199). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  410. 2016-03-08 15:47:28.518 [INFO ] [runtime.busevents ] - agsBus16Discrete state updated to CLOSED
  411. 2016-03-08 15:47:28.804 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: f7 03 00 2a 00 0e f1 50
  412. 2016-03-08 15:47:28.804 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  413. 2016-03-08 15:47:28.804 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@7db608bc (unit id 247 & transaction 1200). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  414. 2016-03-08 15:47:28.855 [INFO ] [runtime.busevents ] - agsBusMasterUptimeSeconds state updated to 31
  415. 2016-03-08 15:47:28.855 [INFO ] [runtime.busevents ] - agsBusMasterErrorsTimeout state updated to 855
  416. 2016-03-08 15:47:28.855 [INFO ] [runtime.busevents ] - agsBusMasterUptimeMinutes state updated to 38
  417. 2016-03-08 15:47:28.855 [INFO ] [runtime.busevents ] - agsBusMasterQueriesToBus state updated to 16709
  418. 2016-03-08 15:47:28.855 [INFO ] [runtime.busevents ] - agsBusMasterSuccessfulTransactions state updated to 6111
  419. 2016-03-08 15:47:28.855 [INFO ] [runtime.busevents ] - agsBusMasterUptimeDays state updated to 32
  420. 2016-03-08 15:47:28.855 [INFO ] [runtime.busevents ] - agsBusMasterErrorsCRC state updated to 844
  421. 2016-03-08 15:47:28.856 [INFO ] [runtime.busevents ] - agsBusMasterPerformanceRS232 state updated to 215
  422. 2016-03-08 15:47:28.856 [INFO ] [runtime.busevents ] - agsBusMasterQueriesToBusMaster state updated to 20754
  423. 2016-03-08 15:47:28.856 [INFO ] [runtime.busevents ] - agsBusMasterTimeoutThreshold state updated to 2500
  424. 2016-03-08 15:47:28.856 [INFO ] [runtime.busevents ] - agsBusMasterPerformanceTotal state updated to 4899
  425. 2016-03-08 15:47:28.856 [INFO ] [runtime.busevents ] - agsBusMasterUptimeHours state updated to 23
  426. 2016-03-08 15:47:29.141 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 03 02 00 00 00 01 b8 28
  427. 2016-03-08 15:47:29.141 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  428. 2016-03-08 15:47:29.141 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@1d013bac (unit id 3 & transaction 1201). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  429. 2016-03-08 15:47:29.230 [INFO ] [runtime.busevents ] - Mitteleingang state updated to CLOSED
  430. 2016-03-08 15:47:29.514 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 10 04 00 00 00 02 72 8a
  431. 2016-03-08 15:47:29.514 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  432. 2016-03-08 15:47:29.514 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputRegistersRequest@465ef08c (unit id 16 & transaction 1202). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  433. 2016-03-08 15:47:29.585 [INFO ] [runtime.busevents ] - agsBus16InputRegister0 state updated to 24795
  434. 2016-03-08 15:47:29.585 [INFO ] [runtime.busevents ] - agsBus16InputRegister1 state updated to 24060
  435. 2016-03-08 15:47:29.871 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 07 01 00 00 00 18 3c 66
  436. 2016-03-08 15:47:29.871 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  437. 2016-03-08 15:47:29.871 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@27f41054 (unit id 7 & transaction 1203). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  438. 2016-03-08 15:47:29.937 [INFO ] [runtime.busevents ] - agsBus7Out0 state updated to ON
  439. 2016-03-08 15:47:29.937 [INFO ] [runtime.busevents ] - agsBus7Out1 state updated to ON
  440. 2016-03-08 15:47:29.937 [INFO ] [runtime.busevents ] - agsBus7Out4 state updated to ON
  441. 2016-03-08 15:47:29.937 [INFO ] [runtime.busevents ] - agsBus7Out5 state updated to OFF
  442. 2016-03-08 15:47:29.937 [INFO ] [runtime.busevents ] - agsBus7Out2 state updated to ON
  443. 2016-03-08 15:47:29.937 [INFO ] [runtime.busevents ] - agsBus7Out3 state updated to ON
  444. 2016-03-08 15:47:29.938 [INFO ] [runtime.busevents ] - agsBus7Out6 state updated to OFF
  445. 2016-03-08 15:47:29.938 [INFO ] [runtime.busevents ] - agsBus7Out7 state updated to OFF
  446. 2016-03-08 15:47:29.938 [INFO ] [runtime.busevents ] - agsBus7EventShortIn2 state updated to ON
  447. 2016-03-08 15:47:29.938 [INFO ] [runtime.busevents ] - agsBus7EventShortIn1 state updated to ON
  448. 2016-03-08 15:47:29.938 [INFO ] [runtime.busevents ] - agsBus7EventShortIn0 state updated to ON
  449. 2016-03-08 15:47:29.938 [INFO ] [runtime.busevents ] - agsBus7EventShortIn6 state updated to ON
  450. 2016-03-08 15:47:29.938 [INFO ] [runtime.busevents ] - agsBus7EventShortIn5 state updated to ON
  451. 2016-03-08 15:47:29.938 [INFO ] [runtime.busevents ] - agsBus7EventShortIn4 state updated to ON
  452. 2016-03-08 15:47:29.938 [INFO ] [runtime.busevents ] - agsBus7EventShortIn3 state updated to ON
  453. 2016-03-08 15:47:29.938 [INFO ] [runtime.busevents ] - agsBus7EventShortIn7 state updated to OFF
  454. 2016-03-08 15:47:29.938 [INFO ] [runtime.busevents ] - agsBus7EventLongIn7 state updated to OFF
  455. 2016-03-08 15:47:29.938 [INFO ] [runtime.busevents ] - agsBus7EventLongIn0 state updated to OFF
  456. 2016-03-08 15:47:29.938 [INFO ] [runtime.busevents ] - agsBus7EventLongIn2 state updated to OFF
  457. 2016-03-08 15:47:29.938 [INFO ] [runtime.busevents ] - agsBus7EventLongIn1 state updated to OFF
  458. 2016-03-08 15:47:29.938 [INFO ] [runtime.busevents ] - agsBus7EventLongIn4 state updated to OFF
  459. 2016-03-08 15:47:29.938 [INFO ] [runtime.busevents ] - agsBus7EventLongIn3 state updated to OFF
  460. 2016-03-08 15:47:29.938 [INFO ] [runtime.busevents ] - agsBus7EventLongIn6 state updated to OFF
  461. 2016-03-08 15:47:29.938 [INFO ] [runtime.busevents ] - agsBus7EventLongIn5 state updated to OFF
  462. 2016-03-08 15:47:30.224 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 0a 01 00 00 00 18 3d 7b
  463. 2016-03-08 15:47:30.224 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  464. 2016-03-08 15:47:30.224 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@6aca1ffe (unit id 10 & transaction 1204). Serial parameters: SerialParameters@7998efd[portName=/dev/ttyS0,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
  465. 2016-03-08 15:47:30.290 [INFO ] [runtime.busevents ] - agsBus10EventLongIn3 state updated to OFF