- 16:30:14.471 [DEBUG] [.s.internal.SchedulerActivator:36 ] - Scheduler has been started.
- 16:30:14.561 [INFO ] [uartz.impl.StdSchedulerFactory:1175 ] - Using default implementation for ThreadExecutor
- 16:30:14.611 [INFO ] [rtz.core.SchedulerSignalerImpl:61 ] - Initialized Scheduler Signaller of type: class org.quartz.core.SchedulerSignalerImpl
- 16:30:14.611 [INFO ] [rg.quartz.core.QuartzScheduler:243 ] - Quartz Scheduler v.2.1.7 created.
- 16:30:14.611 [INFO ] [org.quartz.simpl.RAMJobStore :154 ] - RAMJobStore initialized.
- 16:30:14.611 [INFO ] [rg.quartz.core.QuartzScheduler:268 ] - Scheduler meta-data: Quartz Scheduler (v2.1.7) 'openHAB-job-scheduler' with instanceId 'NON_CLUSTERED'
- Scheduler class: 'org.quartz.core.QuartzScheduler' - running locally.
- NOT STARTED.
- Currently in standby mode.
- Number of jobs executed: 0
- Using thread pool 'org.quartz.simpl.SimpleThreadPool' - with 2 threads.
- Using job-store 'org.quartz.simpl.RAMJobStore' - which does not support persistence. and is not clustered.
- 16:30:14.621 [INFO ] [uartz.impl.StdSchedulerFactory:1324 ] - Quartz scheduler 'openHAB-job-scheduler' initialized from specified file: './etc/quartz.properties'
- 16:30:14.621 [INFO ] [uartz.impl.StdSchedulerFactory:1328 ] - Quartz scheduler version: 2.1.7
- 16:30:14.621 [INFO ] [rg.quartz.core.QuartzScheduler:534 ] - Scheduler openHAB-job-scheduler_$_NON_CLUSTERED started.
- 16:30:14.631 [DEBUG] [o.config.core.ConfigDispatcher:146 ] - Processing openHAB default configuration file 'C:\openhab\configurations\openhab_default.cfg'.
- 16:30:15.143 [DEBUG] [o.config.core.ConfigDispatcher:168 ] - Processing openHAB main configuration file 'C:\openhab\configurations\openhab.cfg'.
- 16:30:15.527 [DEBUG] [.o.core.internal.CoreActivator:93 ] - UUID file already exists at 'C:\openhab\webapps\static\uuid' with content 'scythe'
- 16:30:15.537 [DEBUG] [.o.core.internal.CoreActivator:115 ] - Created file 'C:\openhab\webapps\static\version' with content '1.8.1'
- 16:30:15.537 [INFO ] [.o.core.internal.CoreActivator:61 ] - openHAB runtime has been started (v1.8.1).
- 16:30:15.659 [DEBUG] [a.internal.AutoUpdateActivator:31 ] - AutoUpdate binding has been started.
- 16:30:17.794 [DEBUG] [.p.i.PersistenceModelActivator:23 ] - Registered 'persistence' configuration parser
- 16:30:17.912 [DEBUG] [.c.t.i.TransformationActivator:38 ] - Transformation Service has been started.
- 16:30:18.045 [DEBUG] [m.internal.MultimediaActivator:34 ] - Multimedia I/O bundle has been started.
- 16:30:18.153 [DEBUG] [.s.i.DiscoveryServiceActivator:27 ] - Discovery service has been started.
- 16:30:18.170 [INFO ] [o.o.i.s.i.DiscoveryServiceImpl:93 ] - mDNS service has been started
- 16:30:18.224 [DEBUG] [.io.transport.mqtt.MqttService:123 ] - Starting MQTT Service...
- 16:30:18.580 [DEBUG] [.i.internal.ItemModelActivator:24 ] - Registered 'item' configuration parser
- 16:30:18.757 [DEBUG] [o.o.c.i.items.ItemRegistryImpl:137 ] - Item provider 'GenericItemProvider' has been added.
- 16:30:19.554 [INFO ] [o.o.i.s.i.DiscoveryServiceImpl:53 ] - Service Discovery initialization completed.
- 16:30:20.789 [DEBUG] [.o.m.s.i.SitemapModelActivator:23 ] - Registered 'sitemap' configuration parser
- 16:30:21.020 [DEBUG] [io.rest.internal.RESTActivator:33 ] - REST API has been started.
- 16:30:21.157 [INFO ] [org.atmosphere.util.IOUtils :370 ] - META-INF/services/org.atmosphere.cpr.AtmosphereFramework not found in class loader
- 16:30:21.237 [INFO ] [sphere.cpr.AtmosphereFramework:2601 ] - Atmosphere is using org.atmosphere.cpr.DefaultAnnotationProcessor for processing annotation
- 16:30:21.240 [INFO ] [cpr.DefaultAnnotationProcessor:138 ] - AnnotationProcessor class org.atmosphere.cpr.DefaultAnnotationProcessor$BytecodeBasedAnnotationProcessor being used
- 16:30:21.275 [WARN ] [cpr.DefaultAnnotationProcessor:178 ] - Unable to detect annotations. Application may fail to deploy.
- 16:30:21.342 [INFO ] [sphere.cpr.AtmosphereFramework:1891 ] - Auto detecting atmosphere handlers /WEB-INF/classes/
- 16:30:21.388 [INFO ] [sphere.cpr.AtmosphereFramework:639 ] - Installed AtmosphereHandler org.atmosphere.handler.ReflectorServletProcessor mapped to context-path /* and Broadcaster Class org.atmosphere.jersey.JerseyBroadcaster
- 16:30:21.391 [INFO ] [sphere.cpr.AtmosphereFramework:1945 ] - Auto detecting WebSocketHandler in /WEB-INF/classes/
- 16:30:21.395 [INFO ] [sphere.cpr.AtmosphereFramework:1602 ] - Installed WebSocketProtocol org.atmosphere.websocket.protocol.SimpleHttpProtocol
- 16:30:21.465 [INFO ] [.a.h.ReflectorServletProcessor:103 ] - Installing Servlet com.sun.jersey.spi.container.servlet.ServletContainer
- 16:30:21.718 [INFO ] [c.s.j.s.i.a.WebApplicationImpl:815 ] - Initiating Jersey application, version 'Jersey: 1.18.1 02/19/2014 03:28 AM'
- 16:30:21.724 [INFO ] [c.s.j.s.i.a.WebApplicationImpl:826 ] - Adding the following classes declared in META-INF/services/jersey-server-components to the resource configuration:
- class org.atmosphere.jersey.AtmosphereResourceConfigurator
- 16:30:21.866 [INFO ] [j.s.i.a.DeferredResourceConfig:101 ] - Instantiated the Application class org.openhab.io.rest.RESTApplication
- 16:30:23.863 [INFO ] [sphere.cpr.AtmosphereFramework:2435 ] - AtmosphereInterceptor CORS Interceptor Support will always be executed first
- 16:30:23.864 [INFO ] [sphere.cpr.AtmosphereFramework:2404 ] - Installed AtmosphereInterceptor CORS Interceptor Support with priority FIRST_BEFORE_DEFAULT
- 16:30:23.867 [INFO ] [sphere.cpr.AtmosphereFramework:2404 ] - Installed AtmosphereInterceptor Default Response's Headers Interceptor with priority AFTER_DEFAULT
- 16:30:23.887 [INFO ] [sphere.cpr.AtmosphereFramework:2404 ] - Installed AtmosphereInterceptor Android Interceptor Support with priority AFTER_DEFAULT
- 16:30:23.891 [INFO ] [sphere.cpr.AtmosphereFramework:2404 ] - Installed AtmosphereInterceptor SSE Interceptor Support with priority AFTER_DEFAULT
- 16:30:23.894 [INFO ] [sphere.cpr.AtmosphereFramework:2404 ] - Installed AtmosphereInterceptor JSONP Interceptor Support with priority AFTER_DEFAULT
- 16:30:23.899 [INFO ] [sphere.cpr.AtmosphereFramework:2404 ] - Installed AtmosphereInterceptor Atmosphere JavaScript Protocol with priority AFTER_DEFAULT
- 16:30:23.921 [INFO ] [sphere.cpr.AtmosphereFramework:2404 ] - Installed AtmosphereInterceptor Browser disconnection detection with priority AFTER_DEFAULT
- 16:30:23.930 [INFO ] [sphere.cpr.AtmosphereFramework:935 ] - Using EndpointMapper class org.atmosphere.util.DefaultEndpointMapper
- 16:30:23.933 [WARN ] [sphere.cpr.AtmosphereFramework:941 ] - No BroadcasterCache configured. Broadcasted message between client reconnection will be LOST. It is recommended to configure the org.atmosphere.cache.UUIDBroadcasterCache
- 16:30:23.935 [INFO ] [sphere.cpr.AtmosphereFramework:949 ] - Default Broadcaster Class: org.atmosphere.jersey.JerseyBroadcaster
- 16:30:23.936 [INFO ] [sphere.cpr.AtmosphereFramework:950 ] - Broadcaster Polling Wait Time 100
- 16:30:23.938 [INFO ] [sphere.cpr.AtmosphereFramework:951 ] - Shared ExecutorService supported: true
- 16:30:23.941 [INFO ] [sphere.cpr.AtmosphereFramework:958 ] - Messaging Thread Pool Size: 10
- 16:30:23.942 [INFO ] [sphere.cpr.AtmosphereFramework:968 ] - Async I/O Thread Pool Size: 10
- 16:30:23.943 [INFO ] [sphere.cpr.AtmosphereFramework:979 ] - Using BroadcasterFactory: org.atmosphere.cpr.DefaultBroadcasterFactory
- 16:30:23.946 [INFO ] [sphere.cpr.AtmosphereFramework:980 ] - Using WebSocketProcessor: org.atmosphere.websocket.DefaultWebSocketProcessor
- 16:30:23.947 [INFO ] [sphere.cpr.AtmosphereFramework:990 ] - Invoke AtmosphereInterceptor on WebSocket message true
- 16:30:23.950 [INFO ] [sphere.cpr.AtmosphereFramework:991 ] - HttpSession supported: false
- 16:30:23.964 [INFO ] [sphere.cpr.AtmosphereFramework:993 ] - Atmosphere is using DefaultAtmosphereObjectFactory for dependency injection and object creation
- 16:30:23.966 [INFO ] [sphere.cpr.AtmosphereFramework:994 ] - Atmosphere is using async support: org.atmosphere.container.JettyAsyncSupportWithWebSocket running under container: jetty/8.1.3.v20120522 with WebSocket enabled.
- 16:30:23.969 [INFO ] [sphere.cpr.AtmosphereFramework:996 ] - Atmosphere Framework 2.2.5 started.
- 16:30:23.971 [INFO ] [sphere.cpr.AtmosphereFramework:998 ] -
- For Atmosphere Framework Commercial Support, visit
- http://www.async-io.org/ or send an email to support@async-io.org
- 16:30:23.973 [INFO ] [penhab.io.rest.RESTApplication:144 ] - Started REST API at /rest
- 16:30:23.977 [DEBUG] [o.o.i.s.i.DiscoveryServiceImpl:66 ] - Registering new service _openhab-server._tcp.local. at port 8080
- 16:30:27.106 [DEBUG] [o.o.i.s.i.DiscoveryServiceImpl:66 ] - Registering new service _openhab-server-ssl._tcp.local. at port 8443
- 16:30:27.286 [INFO ] [c.internal.ModelRepositoryImpl:80 ] - Loading model 'demo.sitemap'
- 16:30:27.669 [INFO ] [c.internal.ModelRepositoryImpl:80 ] - Loading model 'db4o.persist'
- 16:30:27.722 [INFO ] [c.internal.ModelRepositoryImpl:80 ] - Loading model 'exec.persist'
- 16:30:27.738 [INFO ] [c.internal.ModelRepositoryImpl:80 ] - Loading model 'logging.persist'
- 16:30:27.758 [INFO ] [c.internal.ModelRepositoryImpl:80 ] - Loading model 'rrd4j.persist'
- 16:30:27.895 [INFO ] [c.internal.ModelRepositoryImpl:80 ] - Loading model 'demo.script'
- 16:30:28.133 [INFO ] [c.internal.ModelRepositoryImpl:80 ] - Loading model 'demo.items'
- 16:30:28.186 [DEBUG] [i.internal.GenericItemProvider:154 ] - Processing binding configs for items from model 'demo.items'
- 16:30:28.206 [DEBUG] [i.internal.GenericItemProvider:133 ] - Read items from model 'demo.items'
- 16:30:30.050 [INFO ] [.o.u.w.i.servlet.WebAppServlet:80 ] - Started Classic UI at /classicui/openhab.app
- 16:30:30.877 [DEBUG] [.r.internal.RuleModelActivator:42 ] - Registered 'rules' configuration parser
- 16:30:30.901 [DEBUG] [m.r.internal.engine.RuleEngine:77 ] - Started rule engine
- 16:30:34.955 [DEBUG] [.m.i.MyOpenHABServiceActivator:28 ] - MyOpenHAB service has been started.
- 16:30:34.961 [DEBUG] [o.o.i.m.i.MyOpenHABServiceImpl:300 ] - setEventPublisher
- 16:30:34.964 [DEBUG] [o.o.i.m.i.MyOpenHABServiceImpl:135 ] - my.openHAB service activated
- 16:30:34.967 [DEBUG] [o.o.i.m.i.MyOpenHABServiceImpl:118 ] - config is null
- 16:30:34.969 [DEBUG] [o.o.i.m.i.MyOpenHABServiceImpl:176 ] - UUID file found at 'C:\openhab\webapps\static\uuid' with content 'scythe'
- 16:30:34.969 [DEBUG] [.p.internal.PersistenceManager:146 ] - Initializing myopenhab persistence service.
- 16:30:34.970 [DEBUG] [o.o.i.m.i.MyOpenHABServiceImpl:228 ] - Secret file already exists at 'C:\openhab\webapps\static\secret' with content 'sasa83'
- 16:30:34.973 [DEBUG] [o.o.i.m.i.MyOpenHABServiceImpl:120 ] - UUID = scythe, secret = sasa83
- 16:30:34.977 [DEBUG] [c.internal.ModelRepositoryImpl:64 ] - Configuration model 'myopenhab.persist' can not be found
- 16:30:34.986 [DEBUG] [o.o.i.m.i.MyOpenHABServiceImpl:176 ] - UUID file found at 'C:\openhab\webapps\static\uuid' with content 'scythe'
- 16:30:34.989 [DEBUG] [o.o.i.m.i.MyOpenHABServiceImpl:228 ] - Secret file already exists at 'C:\openhab\webapps\static\secret' with content 'sasa83'
- 16:30:34.991 [DEBUG] [o.o.i.m.i.MyOpenHABServiceImpl:162 ] - Version file found at 'C:\openhab\webapps\static\version' with content '1.8.1'
- 16:30:35.027 [DEBUG] [o.b.s.internal.SerialActivator:31 ] - Serial binding has been started.
- 16:30:35.060 [DEBUG] [.myopenhab.internal.MyOHClient:138 ] - Manager.EVENT_TRANSPORT
- 16:30:35.183 [DEBUG] [.b.http.internal.HttpActivator:34 ] - HTTP binding has been started.
- 16:30:35.229 [DEBUG] [.myopenhab.internal.MyOHClient:143 ] - Transport.EVENT_REQUEST_HEADERS
- 16:30:35.280 [INFO ] [.service.AbstractActiveService:169 ] - HTTP Refresh Service has been started
- 16:30:35.282 [DEBUG] [.o.b.ntp.internal.NtpActivator:31 ] - NTP binding has been started.
- 16:30:35.308 [INFO ] [.service.AbstractActiveService:169 ] - NTP Refresh Service has been started
- 16:30:35.312 [DEBUG] [inding.ntp.internal.NtpBinding:78 ] - There is no existing NTP binding configuration => refresh cycle aborted!
- 16:30:35.325 [DEBUG] [o.b.m.internal.ModbusActivator:31 ] - Modbus binding has been started.
- 16:30:35.354 [DEBUG] [i.internal.GenericItemProvider:341 ] - Start processing binding configuration of Item 'LED (Type=SwitchItem, State=Uninitialized)' with 'ModbusGenericBindingProvider' reader.
- 16:30:35.409 [DEBUG] [i.internal.GenericItemProvider:341 ] - Start processing binding configuration of Item 'NTC (Type=NumberItem, State=Uninitialized)' with 'ModbusGenericBindingProvider' reader.
- 16:30:35.411 [DEBUG] [i.internal.GenericItemProvider:341 ] - Start processing binding configuration of Item 'BTN (Type=ContactItem, State=Uninitialized)' with 'ModbusGenericBindingProvider' reader.
- 16:30:35.525 [DEBUG] [.i.LoggingPersistenceActivator:31 ] - Logging persistence bundle has been started.
- 16:30:35.557 [DEBUG] [.modbus.internal.ModbusBinding:408 ] - modbusSlave 'slave1' instanciated
- 16:30:35.615 [DEBUG] [.modbus.internal.ModbusBinding:408 ] - modbusSlave 'slave2' instanciated
- 16:30:35.616 [DEBUG] [.modbus.internal.ModbusBinding:408 ] - modbusSlave 'slave4' instanciated
- 16:30:35.646 [DEBUG] [.modbus.internal.ModbusBinding:526 ] - Parsed the following slave->endpoint configurations: {slave4=EndpointPoolConfiguration@584cf706[passivateBorrowMinMillis=100,interConnectDelayMillis=0,connectMaxTries=3,reconnectAfterMillis=-1], slave2=EndpointPoolConfiguration@55d4ae82[passivateBorrowMinMillis=100,interConnectDelayMillis=0,connectMaxTries=3,reconnectAfterMillis=-1], slave1=EndpointPoolConfiguration@3aa57028[passivateBorrowMinMillis=100,interConnectDelayMillis=0,connectMaxTries=3,reconnectAfterMillis=-1]}. If the endpoint is same, connections are shared between the instances.
- 16:30:35.648 [DEBUG] [.modbus.internal.ModbusBinding:528 ] - Parsed the following pool configurations: {ModbusSerialSlaveEndpoint@601583b1[portName=COM6]=EndpointPoolConfiguration@3aa57028[passivateBorrowMinMillis=100,interConnectDelayMillis=0,connectMaxTries=3,reconnectAfterMillis=-1]}
- 16:30:35.655 [DEBUG] [.modbus.internal.ModbusBinding:529 ] - config looked good
- 16:30:35.658 [INFO ] [.service.AbstractActiveService:169 ] - Modbus Polling Service has been started
- 16:30:35.702 [DEBUG] [.p.internal.PersistenceManager:146 ] - Initializing logging persistence service.
- 16:30:35.766 [TRACE] [dbusSlaveConnectionFactoryImpl:78 ] - Created connection SerialConnection@2e25a14e[portName=COM6,port=<null>] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:30:35.784 [DEBUG] [xecPersistenceServiceActivator:33 ] - Exec persistence bundle has been started.
- 16:30:35.797 [DEBUG] [.p.internal.PersistenceManager:146 ] - Initializing exec persistence service.
- 16:30:35.844 [DEBUG] [.p.internal.PersistenceManager:428 ] - Scheduled strategy exec.everyMinute with cron expression 0 * * * * ?
- 16:30:35.892 [DEBUG] [.rrd4j.internal.RRD4jActivator:31 ] - RRD4j persistence bundle has been started.
- 16:30:35.915 [DEBUG] [.p.rrd4j.internal.RRD4jService:395 ] - Unknown property name : org.openhab.persistence.rrd4j
- 16:30:35.916 [DEBUG] [.p.rrd4j.internal.RRD4jService:364 ] - config 'objectClass' should have the format 'name.configkey'
- 16:30:35.919 [INFO ] [.p.rrd4j.internal.RRD4jService:407 ] - Removing invalid defintion component = null heartbeat = 0 min/max = 0.0/0.0 step = 0 0 archives(s) = [] 0 items(s) = []
- 16:30:35.959 [DEBUG] [.p.rrd4j.internal.RRD4jService:405 ] - Created default_other = GAUGE heartbeat = 3600 min/max = NaN/NaN step = 1 6 archives(s) = [ MAX xff = 0.999 steps = 1 rows = 3600 MAX xff = 0.999 steps = 10 rows = 1440 MAX xff = 0.999 steps = 60 rows = 1440 MAX xff = 0.999 steps = 900 rows = 2880 MAX xff = 0.999 steps = 21600 rows = 1460 MAX xff = 0.999 steps = 86400 rows = 3650] 0 items(s) = []
- 16:30:35.979 [DEBUG] [.p.rrd4j.internal.RRD4jService:405 ] - Created default_numeric = GAUGE heartbeat = 60 min/max = NaN/NaN step = 60 6 archives(s) = [ AVERAGE xff = 0.5 steps = 1 rows = 480 AVERAGE xff = 0.5 steps = 4 rows = 360 AVERAGE xff = 0.5 steps = 14 rows = 644 AVERAGE xff = 0.5 steps = 60 rows = 720 AVERAGE xff = 0.5 steps = 720 rows = 730 AVERAGE xff = 0.5 steps = 10080 rows = 520] 0 items(s) = []
- 16:30:35.982 [DEBUG] [.p.internal.PersistenceManager:146 ] - Initializing rrd4j persistence service.
- 16:30:35.990 [DEBUG] [.myopenhab.internal.MyOHClient:138 ] - Manager.EVENT_TRANSPORT
- 16:30:35.997 [DEBUG] [.myopenhab.internal.MyOHClient:143 ] - Transport.EVENT_REQUEST_HEADERS
- 16:30:36.007 [DEBUG] [.p.internal.PersistenceManager:315 ] - Item 'DemoSwitch' does not exist.
- 16:30:36.011 [DEBUG] [.p.internal.PersistenceManager:315 ] - Item 'NoOfLights' does not exist.
- 16:30:36.014 [DEBUG] [.p.internal.PersistenceManager:315 ] - Item 'Window_GF_Toilet' does not exist.
- 16:30:36.016 [DEBUG] [.p.internal.PersistenceManager:328 ] - Item group 'Heating' does not exist.
- 16:30:36.021 [DEBUG] [.p.internal.PersistenceManager:328 ] - Item group 'Temperature' does not exist.
- 16:30:36.023 [DEBUG] [.p.internal.PersistenceManager:328 ] - Item group 'Weather_Chart' does not exist.
- 16:30:36.030 [DEBUG] [.p.internal.PersistenceManager:428 ] - Scheduled strategy rrd4j.everyMinute with cron expression 0 * * * * ?
- 16:30:36.044 [DEBUG] [p.r.i.charts.RRD4jChartServlet:118 ] - Starting up rrd chart servlet at /rrdchart.png
- 16:30:36.172 [DEBUG] [.myopenhab.internal.MyOHClient:143 ] - Transport.EVENT_REQUEST_HEADERS
- 16:30:37.176 [TRACE] [pi.modbus.net.SerialConnection:128 ] - Got Port Identifier
- 16:30:37.244 [TRACE] [pi.modbus.net.SerialConnection:138 ] - Got Serial Port
- 16:30:37.276 [TRACE] [pi.modbus.net.SerialConnection:174 ] - i/o Streams prepared
- 16:30:37.279 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@2e25a14e[portName=COM6,port=//./COM6] -> true
- 16:30:37.286 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave1): borrowing connection (got SerialConnection@2e25a14e[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] took 1615 ms
- 16:30:37.291 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:30:37.706 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:30:37.707 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:37.717 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@34ab323a (unit id 1 & transaction 1). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:37.820 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:30:38.248 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:30:38.258 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:38.270 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@34ab323a (unit id 1 & transaction 1). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:38.364 [INFO ] [c.internal.ModelRepositoryImpl:80 ] - Loading model 'demo.rules'
- 16:30:38.383 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:30:38.432 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 01 01 02 d0 49
- 16:30:38.441 [INFO ] [w.m.io.ModbusSerialTransaction:213 ] - execute eventually succeeded with 2 re-tries. Request: net.wimpi.modbus.msg.ReadCoilsRequest@34ab323a. Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:38.443 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@2e25a14e[portName=COM6,port=//./COM6] -> true
- 16:30:38.444 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@2e25a14e[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]...
- 16:30:38.446 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@2e25a14e[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]) age (1168ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:30:38.448 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@2e25a14e[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:30:38.451 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave1): returned connection for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:30:38.454 [TRACE] [et.wimpi.modbus.util.BitVector:141 ] - Get bit #0
- 16:30:38.547 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 70ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@2e25a14e[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6], to ensure delay between transactions.
- 16:30:38.549 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@2e25a14e[portName=COM6,port=//./COM6] -> true
- 16:30:38.550 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave2): borrowing connection (got SerialConnection@2e25a14e[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] took 74 ms
- 16:30:38.552 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:30:38.789 [DEBUG] [.myopenhab.internal.MyOHClient:157 ] - Socket.IO connected
- 16:30:38.791 [INFO ] [.myopenhab.internal.MyOHClient:224 ] - Connected to my.openHAB service (UUID = scythe, local base URL = http://localhost:8080)
- 16:30:38.962 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:30:38.963 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:38.971 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@51924791 (unit id 1 & transaction 2). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:39.074 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:30:39.687 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:30:39.688 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:39.696 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@51924791 (unit id 1 & transaction 2). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:39.798 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:30:40.225 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:30:40.225 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:40.235 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@51924791 (unit id 1 & transaction 2). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:40.235 [ERROR] [w.m.io.ModbusSerialTransaction:204 ] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@51924791. Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:40.235 [ERROR] [o.b.m.internal.BaseModbusSlave:412 ] - ModbusSlave (slave2): Error getting modbus data for request net.wimpi.modbus.msg.ReadInputDiscretesRequest@51924791. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]. Connection: SerialConnection@2e25a14e[portName=COM6,port=//./COM6]
- 16:30:40.295 [ERROR] [o.b.m.internal.BaseModbusSlave:367 ] - ModbusSlave (slave2) error getting response from slave. Invalidating connection
- java.lang.NullPointerException: null
- at org.openhab.binding.modbus.internal.BaseModbusSlave.update(BaseModbusSlave.java:345) ~[bundlefile:na]
- at org.openhab.binding.modbus.internal.ModbusBinding.execute(ModbusBinding.java:331) [bundlefile:na]
- at org.openhab.core.binding.AbstractActiveBinding$BindingActiveService.execute(AbstractActiveBinding.java:156) [org.openhab.core_1.8.1.jar:na]
- at org.openhab.core.service.AbstractActiveService$RefreshThread.run(AbstractActiveService.java:173) [org.openhab.core_1.8.1.jar:na]
- 16:30:40.295 [TRACE] [dbusSlaveConnectionFactoryImpl:78 ] - Created connection SerialConnection@4b03357d[portName=COM6,port=<null>] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:30:40.305 [TRACE] [pi.modbus.net.SerialConnection:128 ] - Got Port Identifier
- 16:30:40.395 [TRACE] [pi.modbus.net.SerialConnection:138 ] - Got Serial Port
- 16:30:40.426 [TRACE] [pi.modbus.net.SerialConnection:174 ] - i/o Streams prepared
- 16:30:40.426 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@4b03357d[portName=COM6,port=//./COM6] -> true
- 16:30:40.426 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave4): borrowing connection (got SerialConnection@4b03357d[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] took 131 ms
- 16:30:40.426 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:30:40.476 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 03 02 00 00 b8 44
- 16:30:40.486 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@4b03357d[portName=COM6,port=//./COM6] -> true
- 16:30:40.486 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@4b03357d[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]...
- 16:30:40.486 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@4b03357d[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]) age (60ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:30:40.486 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@4b03357d[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:30:40.486 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave4): returned connection for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:30:40.590 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 90ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@4b03357d[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6], to ensure delay between transactions.
- 16:30:40.590 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@4b03357d[portName=COM6,port=//./COM6] -> true
- 16:30:40.590 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave1): borrowing connection (got SerialConnection@4b03357d[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] took 94 ms
- 16:30:40.590 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:30:40.641 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 01 01 02 d0 49
- 16:30:40.673 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@4b03357d[portName=COM6,port=//./COM6] -> true
- 16:30:40.674 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@4b03357d[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]...
- 16:30:40.675 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@4b03357d[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]) age (249ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:30:40.679 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@4b03357d[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:30:40.680 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave1): returned connection for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:30:40.683 [TRACE] [et.wimpi.modbus.util.BitVector:141 ] - Get bit #0
- 16:30:40.775 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 92ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@4b03357d[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6], to ensure delay between transactions.
- 16:30:40.779 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@4b03357d[portName=COM6,port=//./COM6] -> true
- 16:30:40.780 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave2): borrowing connection (got SerialConnection@4b03357d[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] took 97 ms
- 16:30:40.781 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:30:41.191 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:30:41.192 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:41.200 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@2ab2c4fd (unit id 1 & transaction 5). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:41.305 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:30:41.735 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:30:41.735 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:41.747 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@2ab2c4fd (unit id 1 & transaction 5). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:41.849 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:30:42.260 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:30:42.261 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:42.270 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@2ab2c4fd (unit id 1 & transaction 5). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:42.273 [ERROR] [w.m.io.ModbusSerialTransaction:204 ] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@2ab2c4fd. Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:42.275 [ERROR] [o.b.m.internal.BaseModbusSlave:412 ] - ModbusSlave (slave2): Error getting modbus data for request net.wimpi.modbus.msg.ReadInputDiscretesRequest@2ab2c4fd. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]. Connection: SerialConnection@4b03357d[portName=COM6,port=//./COM6]
- 16:30:42.300 [ERROR] [o.b.m.internal.BaseModbusSlave:367 ] - ModbusSlave (slave2) error getting response from slave. Invalidating connection
- java.lang.NullPointerException: null
- at org.openhab.binding.modbus.internal.BaseModbusSlave.update(BaseModbusSlave.java:345) ~[bundlefile:na]
- at org.openhab.binding.modbus.internal.ModbusBinding.execute(ModbusBinding.java:331) [bundlefile:na]
- at org.openhab.core.binding.AbstractActiveBinding$BindingActiveService.execute(AbstractActiveBinding.java:156) [org.openhab.core_1.8.1.jar:na]
- at org.openhab.core.service.AbstractActiveService$RefreshThread.run(AbstractActiveService.java:173) [org.openhab.core_1.8.1.jar:na]
- 16:30:42.302 [TRACE] [dbusSlaveConnectionFactoryImpl:78 ] - Created connection SerialConnection@29bb92fd[portName=COM6,port=<null>] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:30:42.303 [TRACE] [pi.modbus.net.SerialConnection:128 ] - Got Port Identifier
- 16:30:42.362 [TRACE] [pi.modbus.net.SerialConnection:138 ] - Got Serial Port
- 16:30:42.388 [TRACE] [pi.modbus.net.SerialConnection:174 ] - i/o Streams prepared
- 16:30:42.389 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@29bb92fd[portName=COM6,port=//./COM6] -> true
- 16:30:42.390 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave4): borrowing connection (got SerialConnection@29bb92fd[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] took 89 ms
- 16:30:42.392 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:30:42.802 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:30:42.803 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:42.811 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@52bd47a8 (unit id 1 & transaction 6). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:42.917 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:30:43.338 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:30:43.338 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:43.346 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@52bd47a8 (unit id 1 & transaction 6). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:43.453 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:30:43.887 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:30:43.887 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:43.897 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@52bd47a8 (unit id 1 & transaction 6). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:43.897 [ERROR] [w.m.io.ModbusSerialTransaction:204 ] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@52bd47a8. Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:43.897 [ERROR] [o.b.m.internal.BaseModbusSlave:412 ] - ModbusSlave (slave4): Error getting modbus data for request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@52bd47a8. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]. Connection: SerialConnection@29bb92fd[portName=COM6,port=//./COM6]
- 16:30:43.947 [ERROR] [o.b.m.internal.BaseModbusSlave:367 ] - ModbusSlave (slave4) error getting response from slave. Invalidating connection
- java.lang.NullPointerException: null
- at org.openhab.binding.modbus.internal.BaseModbusSlave.update(BaseModbusSlave.java:349) ~[bundlefile:na]
- at org.openhab.binding.modbus.internal.ModbusBinding.execute(ModbusBinding.java:331) [bundlefile:na]
- at org.openhab.core.binding.AbstractActiveBinding$BindingActiveService.execute(AbstractActiveBinding.java:156) [org.openhab.core_1.8.1.jar:na]
- at org.openhab.core.service.AbstractActiveService$RefreshThread.run(AbstractActiveService.java:173) [org.openhab.core_1.8.1.jar:na]
- 16:30:43.957 [TRACE] [dbusSlaveConnectionFactoryImpl:78 ] - Created connection SerialConnection@66f4208b[portName=COM6,port=<null>] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:30:43.957 [TRACE] [pi.modbus.net.SerialConnection:128 ] - Got Port Identifier
- 16:30:44.048 [TRACE] [pi.modbus.net.SerialConnection:138 ] - Got Serial Port
- 16:30:44.079 [TRACE] [pi.modbus.net.SerialConnection:174 ] - i/o Streams prepared
- 16:30:44.079 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@66f4208b[portName=COM6,port=//./COM6] -> true
- 16:30:44.079 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave1): borrowing connection (got SerialConnection@66f4208b[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] took 122 ms
- 16:30:44.079 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:30:44.501 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:30:44.501 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:44.511 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@5aed4a27 (unit id 1 & transaction 7). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:44.611 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:30:44.651 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 01 01 02 d0 49
- 16:30:44.661 [INFO ] [w.m.io.ModbusSerialTransaction:213 ] - execute eventually succeeded with 1 re-tries. Request: net.wimpi.modbus.msg.ReadCoilsRequest@5aed4a27. Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:44.661 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@66f4208b[portName=COM6,port=//./COM6] -> true
- 16:30:44.661 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@66f4208b[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]...
- 16:30:44.661 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@66f4208b[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]) age (582ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:30:44.661 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@66f4208b[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:30:44.661 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave1): returned connection for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:30:44.661 [TRACE] [et.wimpi.modbus.util.BitVector:141 ] - Get bit #0
- 16:30:44.761 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 90ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@66f4208b[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6], to ensure delay between transactions.
- 16:30:44.764 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@66f4208b[portName=COM6,port=//./COM6] -> true
- 16:30:44.765 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave2): borrowing connection (got SerialConnection@66f4208b[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] took 94 ms
- 16:30:44.769 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:30:45.201 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:30:45.201 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:45.211 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@6255c6d5 (unit id 1 & transaction 8). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:45.311 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:30:45.740 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:30:45.741 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:45.748 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@6255c6d5 (unit id 1 & transaction 8). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:45.849 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:30:45.890 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 02 01 02 20 49
- 16:30:45.899 [INFO ] [w.m.io.ModbusSerialTransaction:213 ] - execute eventually succeeded with 2 re-tries. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@6255c6d5. Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:45.900 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@66f4208b[portName=COM6,port=//./COM6] -> true
- 16:30:45.901 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@66f4208b[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]...
- 16:30:45.902 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@66f4208b[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]) age (1823ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:30:45.903 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@66f4208b[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:30:45.904 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave2): returned connection for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:30:45.905 [TRACE] [et.wimpi.modbus.util.BitVector:141 ] - Get bit #0
- 16:30:46.002 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 96ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@66f4208b[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6], to ensure delay between transactions.
- 16:30:46.003 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@66f4208b[portName=COM6,port=//./COM6] -> true
- 16:30:46.004 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave4): borrowing connection (got SerialConnection@66f4208b[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] took 98 ms
- 16:30:46.004 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:30:46.425 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:30:46.434 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:46.445 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@5d61c7f8 (unit id 1 & transaction 9). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:46.548 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:30:46.584 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 03 02 00 00 b8 44
- 16:30:46.595 [INFO ] [w.m.io.ModbusSerialTransaction:213 ] - execute eventually succeeded with 1 re-tries. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@5d61c7f8. Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:46.596 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@66f4208b[portName=COM6,port=//./COM6] -> true
- 16:30:46.598 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@66f4208b[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]...
- 16:30:46.599 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@66f4208b[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]) age (2519ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:30:46.600 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@66f4208b[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:30:46.601 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave4): returned connection for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:30:46.698 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 87ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@66f4208b[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6], to ensure delay between transactions.
- 16:30:46.700 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@66f4208b[portName=COM6,port=//./COM6] -> true
- 16:30:46.701 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave1): borrowing connection (got SerialConnection@66f4208b[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] took 90 ms
- 16:30:46.703 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:30:46.741 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 01 01 02 d0 49
- 16:30:46.750 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@66f4208b[portName=COM6,port=//./COM6] -> true
- 16:30:46.751 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@66f4208b[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]...
- 16:30:46.754 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@66f4208b[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]) age (2674ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:30:46.755 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@66f4208b[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:30:46.757 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave1): returned connection for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:30:46.759 [TRACE] [et.wimpi.modbus.util.BitVector:141 ] - Get bit #0
- 16:30:46.853 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 93ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@66f4208b[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6], to ensure delay between transactions.
- 16:30:46.856 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@66f4208b[portName=COM6,port=//./COM6] -> true
- 16:30:46.857 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave2): borrowing connection (got SerialConnection@66f4208b[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] took 97 ms
- 16:30:46.860 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:30:47.485 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:30:47.487 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:47.495 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@6ded1201 (unit id 1 & transaction 11). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:47.597 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:30:48.236 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:30:48.236 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:48.246 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@6ded1201 (unit id 1 & transaction 11). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:48.346 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:30:48.758 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:30:48.767 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:48.777 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@6ded1201 (unit id 1 & transaction 11). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:48.778 [ERROR] [w.m.io.ModbusSerialTransaction:204 ] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@6ded1201. Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:48.782 [ERROR] [o.b.m.internal.BaseModbusSlave:412 ] - ModbusSlave (slave2): Error getting modbus data for request net.wimpi.modbus.msg.ReadInputDiscretesRequest@6ded1201. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]. Connection: SerialConnection@66f4208b[portName=COM6,port=//./COM6]
- 16:30:48.809 [ERROR] [o.b.m.internal.BaseModbusSlave:367 ] - ModbusSlave (slave2) error getting response from slave. Invalidating connection
- java.lang.NullPointerException: null
- at org.openhab.binding.modbus.internal.BaseModbusSlave.update(BaseModbusSlave.java:345) ~[bundlefile:na]
- at org.openhab.binding.modbus.internal.ModbusBinding.execute(ModbusBinding.java:331) [bundlefile:na]
- at org.openhab.core.binding.AbstractActiveBinding$BindingActiveService.execute(AbstractActiveBinding.java:156) [org.openhab.core_1.8.1.jar:na]
- at org.openhab.core.service.AbstractActiveService$RefreshThread.run(AbstractActiveService.java:173) [org.openhab.core_1.8.1.jar:na]
- 16:30:48.813 [TRACE] [dbusSlaveConnectionFactoryImpl:78 ] - Created connection SerialConnection@21420207[portName=COM6,port=<null>] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:30:48.815 [TRACE] [pi.modbus.net.SerialConnection:128 ] - Got Port Identifier
- 16:30:48.877 [TRACE] [pi.modbus.net.SerialConnection:138 ] - Got Serial Port
- 16:30:48.904 [TRACE] [pi.modbus.net.SerialConnection:174 ] - i/o Streams prepared
- 16:30:48.906 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@21420207[portName=COM6,port=//./COM6] -> true
- 16:30:48.911 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave4): borrowing connection (got SerialConnection@21420207[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] took 99 ms
- 16:30:48.923 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:30:49.348 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:30:49.352 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:49.359 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@45091e4e (unit id 1 & transaction 12). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:49.460 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:30:49.499 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 03 02 00 00 b8 fd
- 16:30:49.500 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:30:49.500 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: CRC Error in received frame: 5 bytes: 01 03 02 00 00
- 16:30:49.508 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@45091e4e (unit id 1 & transaction 12). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:49.618 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:30:50.046 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:30:50.046 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:50.056 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@45091e4e (unit id 1 & transaction 12). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:50.056 [ERROR] [w.m.io.ModbusSerialTransaction:204 ] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@45091e4e. Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:50.056 [ERROR] [o.b.m.internal.BaseModbusSlave:412 ] - ModbusSlave (slave4): Error getting modbus data for request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@45091e4e. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]. Connection: SerialConnection@21420207[portName=COM6,port=//./COM6]
- 16:30:50.086 [ERROR] [o.b.m.internal.BaseModbusSlave:367 ] - ModbusSlave (slave4) error getting response from slave. Invalidating connection
- java.lang.NullPointerException: null
- at org.openhab.binding.modbus.internal.BaseModbusSlave.update(BaseModbusSlave.java:349) ~[bundlefile:na]
- at org.openhab.binding.modbus.internal.ModbusBinding.execute(ModbusBinding.java:331) [bundlefile:na]
- at org.openhab.core.binding.AbstractActiveBinding$BindingActiveService.execute(AbstractActiveBinding.java:156) [org.openhab.core_1.8.1.jar:na]
- at org.openhab.core.service.AbstractActiveService$RefreshThread.run(AbstractActiveService.java:173) [org.openhab.core_1.8.1.jar:na]
- 16:30:50.096 [TRACE] [dbusSlaveConnectionFactoryImpl:78 ] - Created connection SerialConnection@40f171f4[portName=COM6,port=<null>] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:30:50.096 [TRACE] [pi.modbus.net.SerialConnection:128 ] - Got Port Identifier
- 16:30:50.187 [TRACE] [pi.modbus.net.SerialConnection:138 ] - Got Serial Port
- 16:30:50.220 [TRACE] [pi.modbus.net.SerialConnection:174 ] - i/o Streams prepared
- 16:30:50.221 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@40f171f4[portName=COM6,port=//./COM6] -> true
- 16:30:50.222 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave1): borrowing connection (got SerialConnection@40f171f4[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] took 126 ms
- 16:30:50.223 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:30:50.645 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:30:50.645 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:50.653 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@45096dd9 (unit id 1 & transaction 13). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:50.759 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:30:51.387 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:30:51.387 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:51.397 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@45096dd9 (unit id 1 & transaction 13). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:51.498 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:30:51.909 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:30:51.910 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:51.918 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@45096dd9 (unit id 1 & transaction 13). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:51.919 [ERROR] [w.m.io.ModbusSerialTransaction:204 ] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@45096dd9. Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:51.920 [ERROR] [o.b.m.internal.BaseModbusSlave:412 ] - ModbusSlave (slave1): Error getting modbus data for request net.wimpi.modbus.msg.ReadCoilsRequest@45096dd9. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]. Connection: SerialConnection@40f171f4[portName=COM6,port=//./COM6]
- 16:30:51.946 [ERROR] [o.b.m.internal.BaseModbusSlave:367 ] - ModbusSlave (slave1) error getting response from slave. Invalidating connection
- java.lang.NullPointerException: null
- at org.openhab.binding.modbus.internal.BaseModbusSlave.update(BaseModbusSlave.java:341) ~[bundlefile:na]
- at org.openhab.binding.modbus.internal.ModbusBinding.execute(ModbusBinding.java:331) [bundlefile:na]
- at org.openhab.core.binding.AbstractActiveBinding$BindingActiveService.execute(AbstractActiveBinding.java:156) [org.openhab.core_1.8.1.jar:na]
- at org.openhab.core.service.AbstractActiveService$RefreshThread.run(AbstractActiveService.java:173) [org.openhab.core_1.8.1.jar:na]
- 16:30:51.948 [TRACE] [dbusSlaveConnectionFactoryImpl:78 ] - Created connection SerialConnection@48fff058[portName=COM6,port=<null>] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:30:51.948 [TRACE] [pi.modbus.net.SerialConnection:128 ] - Got Port Identifier
- 16:30:52.017 [TRACE] [pi.modbus.net.SerialConnection:138 ] - Got Serial Port
- 16:30:52.048 [TRACE] [pi.modbus.net.SerialConnection:174 ] - i/o Streams prepared
- 16:30:52.048 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@48fff058[portName=COM6,port=//./COM6] -> true
- 16:30:52.048 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave2): borrowing connection (got SerialConnection@48fff058[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] took 101 ms
- 16:30:52.048 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:30:52.469 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:30:52.469 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:52.479 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@62377375 (unit id 1 & transaction 14). Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:52.579 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:30:53.020 [ERROR] [i.modbus.io.ModbusRTUTransport:230 ] - awaited 3 bytes, but received 0
- 16:30:53.021 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 02 01
- 16:30:53.021 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:30:53.022 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: CRC Error in received frame: 1 bytes: 01
- 16:30:53.030 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@62377375 (unit id 1 & transaction 14). Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:53.137 [DEBUG] [i.modbus.io.ModbusRTUTransport:109 ] - Clear input: 02 20
- 16:30:53.137 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:30:53.568 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:30:53.568 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:53.578 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@62377375 (unit id 1 & transaction 14). Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:53.578 [ERROR] [w.m.io.ModbusSerialTransaction:204 ] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@62377375. Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:53.578 [ERROR] [o.b.m.internal.BaseModbusSlave:412 ] - ModbusSlave (slave2): Error getting modbus data for request net.wimpi.modbus.msg.ReadInputDiscretesRequest@62377375. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]. Connection: SerialConnection@48fff058[portName=COM6,port=//./COM6]
- 16:30:53.618 [ERROR] [o.b.m.internal.BaseModbusSlave:367 ] - ModbusSlave (slave2) error getting response from slave. Invalidating connection
- java.lang.NullPointerException: null
- at org.openhab.binding.modbus.internal.BaseModbusSlave.update(BaseModbusSlave.java:345) ~[bundlefile:na]
- at org.openhab.binding.modbus.internal.ModbusBinding.execute(ModbusBinding.java:331) [bundlefile:na]
- at org.openhab.core.binding.AbstractActiveBinding$BindingActiveService.execute(AbstractActiveBinding.java:156) [org.openhab.core_1.8.1.jar:na]
- at org.openhab.core.service.AbstractActiveService$RefreshThread.run(AbstractActiveService.java:173) [org.openhab.core_1.8.1.jar:na]
- 16:30:53.618 [TRACE] [dbusSlaveConnectionFactoryImpl:78 ] - Created connection SerialConnection@5b94fdac[portName=COM6,port=<null>] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:30:53.618 [TRACE] [pi.modbus.net.SerialConnection:128 ] - Got Port Identifier
- 16:30:53.708 [TRACE] [pi.modbus.net.SerialConnection:138 ] - Got Serial Port
- 16:30:53.740 [TRACE] [pi.modbus.net.SerialConnection:174 ] - i/o Streams prepared
- 16:30:53.740 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@5b94fdac[portName=COM6,port=//./COM6] -> true
- 16:30:53.740 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave4): borrowing connection (got SerialConnection@5b94fdac[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] took 122 ms
- 16:30:53.740 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:30:54.152 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:30:54.152 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:54.160 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@53c9bf03 (unit id 1 & transaction 15). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:54.262 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:30:54.674 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:30:54.675 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:54.685 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@53c9bf03 (unit id 1 & transaction 15). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:54.786 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:30:55.396 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:30:55.397 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:55.405 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@53c9bf03 (unit id 1 & transaction 15). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:55.406 [ERROR] [w.m.io.ModbusSerialTransaction:204 ] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@53c9bf03. Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:55.407 [ERROR] [o.b.m.internal.BaseModbusSlave:412 ] - ModbusSlave (slave4): Error getting modbus data for request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@53c9bf03. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]. Connection: SerialConnection@5b94fdac[portName=COM6,port=//./COM6]
- 16:30:55.426 [ERROR] [o.b.m.internal.BaseModbusSlave:367 ] - ModbusSlave (slave4) error getting response from slave. Invalidating connection
- java.lang.NullPointerException: null
- at org.openhab.binding.modbus.internal.BaseModbusSlave.update(BaseModbusSlave.java:349) ~[bundlefile:na]
- at org.openhab.binding.modbus.internal.ModbusBinding.execute(ModbusBinding.java:331) [bundlefile:na]
- at org.openhab.core.binding.AbstractActiveBinding$BindingActiveService.execute(AbstractActiveBinding.java:156) [org.openhab.core_1.8.1.jar:na]
- at org.openhab.core.service.AbstractActiveService$RefreshThread.run(AbstractActiveService.java:173) [org.openhab.core_1.8.1.jar:na]
- 16:30:55.446 [TRACE] [dbusSlaveConnectionFactoryImpl:78 ] - Created connection SerialConnection@4ae4c4f0[portName=COM6,port=<null>] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:30:55.446 [TRACE] [pi.modbus.net.SerialConnection:128 ] - Got Port Identifier
- 16:30:55.534 [TRACE] [pi.modbus.net.SerialConnection:138 ] - Got Serial Port
- 16:30:55.564 [TRACE] [pi.modbus.net.SerialConnection:174 ] - i/o Streams prepared
- 16:30:55.564 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] -> true
- 16:30:55.564 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave1): borrowing connection (got SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] took 118 ms
- 16:30:55.564 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:30:55.985 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:30:55.986 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:55.994 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@5afe55b2 (unit id 1 & transaction 16). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:56.097 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:30:56.551 [ERROR] [i.modbus.io.ModbusRTUTransport:230 ] - awaited 4 bytes, but received 0
- 16:30:56.551 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 01 02
- 16:30:56.551 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:30:56.551 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: CRC Error in received frame: 1 bytes: 01
- 16:30:56.561 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@5afe55b2 (unit id 1 & transaction 16). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:56.662 [DEBUG] [i.modbus.io.ModbusRTUTransport:109 ] - Clear input: d0 49
- 16:30:56.662 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:30:56.702 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 01 01 02 d0 49
- 16:30:56.712 [INFO ] [w.m.io.ModbusSerialTransaction:213 ] - execute eventually succeeded with 2 re-tries. Request: net.wimpi.modbus.msg.ReadCoilsRequest@5afe55b2. Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:56.712 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] -> true
- 16:30:56.712 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]...
- 16:30:56.712 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]) age (1148ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:30:56.712 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:30:56.712 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave1): returned connection for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:30:56.712 [TRACE] [et.wimpi.modbus.util.BitVector:141 ] - Get bit #0
- 16:30:56.812 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 100ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6], to ensure delay between transactions.
- 16:30:56.812 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] -> true
- 16:30:56.812 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave2): borrowing connection (got SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] took 100 ms
- 16:30:56.812 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:30:56.862 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 02 01 02 20 49
- 16:30:56.872 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] -> true
- 16:30:56.872 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]...
- 16:30:56.872 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]) age (1308ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:30:56.872 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:30:56.872 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave2): returned connection for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:30:56.872 [TRACE] [et.wimpi.modbus.util.BitVector:141 ] - Get bit #0
- 16:30:56.972 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 100ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6], to ensure delay between transactions.
- 16:30:56.974 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] -> true
- 16:30:56.981 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave4): borrowing connection (got SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] took 109 ms
- 16:30:56.989 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:30:57.045 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 03 02 00 00 b8 44
- 16:30:57.061 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] -> true
- 16:30:57.062 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]...
- 16:30:57.076 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]) age (1512ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:30:57.077 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:30:57.088 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave4): returned connection for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:30:57.177 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 78ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6], to ensure delay between transactions.
- 16:30:57.183 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] -> true
- 16:30:57.185 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave1): borrowing connection (got SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] took 87 ms
- 16:30:57.189 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:30:57.225 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 01 01 02 d0 49
- 16:30:57.240 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] -> true
- 16:30:57.241 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]...
- 16:30:57.242 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]) age (1678ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:30:57.243 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:30:57.245 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave1): returned connection for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:30:57.246 [TRACE] [et.wimpi.modbus.util.BitVector:141 ] - Get bit #0
- 16:30:57.342 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 96ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6], to ensure delay between transactions.
- 16:30:57.343 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] -> true
- 16:30:57.344 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave2): borrowing connection (got SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] took 98 ms
- 16:30:57.345 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:30:57.786 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:30:57.786 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:57.796 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@44d1d849 (unit id 1 & transaction 20). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:57.896 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:30:58.308 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:30:58.308 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:58.316 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@44d1d849 (unit id 1 & transaction 20). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:58.425 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:30:58.462 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 02 01 02 20 49
- 16:30:58.471 [INFO ] [w.m.io.ModbusSerialTransaction:213 ] - execute eventually succeeded with 2 re-tries. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@44d1d849. Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:58.474 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] -> true
- 16:30:58.475 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]...
- 16:30:58.477 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]) age (2913ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:30:58.478 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:30:58.482 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave2): returned connection for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:30:58.483 [TRACE] [et.wimpi.modbus.util.BitVector:141 ] - Get bit #0
- 16:30:58.577 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 93ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6], to ensure delay between transactions.
- 16:30:58.584 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6] -> true
- 16:30:58.586 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave4): borrowing connection (got SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] took 102 ms
- 16:30:58.588 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:30:58.625 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 03 02 00 00 b8 fd
- 16:30:58.626 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:30:58.627 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: CRC Error in received frame: 5 bytes: 01 03 02 00 00
- 16:30:58.635 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@28fe4767 (unit id 1 & transaction 21). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:58.737 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:30:59.160 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:30:59.160 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:59.168 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@28fe4767 (unit id 1 & transaction 21). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:59.269 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:30:59.701 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:30:59.701 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:30:59.711 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@28fe4767 (unit id 1 & transaction 21). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:59.711 [ERROR] [w.m.io.ModbusSerialTransaction:204 ] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@28fe4767. Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:30:59.711 [ERROR] [o.b.m.internal.BaseModbusSlave:412 ] - ModbusSlave (slave4): Error getting modbus data for request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@28fe4767. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]. Connection: SerialConnection@4ae4c4f0[portName=COM6,port=//./COM6]
- 16:30:59.741 [ERROR] [o.b.m.internal.BaseModbusSlave:367 ] - ModbusSlave (slave4) error getting response from slave. Invalidating connection
- java.lang.NullPointerException: null
- at org.openhab.binding.modbus.internal.BaseModbusSlave.update(BaseModbusSlave.java:349) ~[bundlefile:na]
- at org.openhab.binding.modbus.internal.ModbusBinding.execute(ModbusBinding.java:331) [bundlefile:na]
- at org.openhab.core.binding.AbstractActiveBinding$BindingActiveService.execute(AbstractActiveBinding.java:156) [org.openhab.core_1.8.1.jar:na]
- at org.openhab.core.service.AbstractActiveService$RefreshThread.run(AbstractActiveService.java:173) [org.openhab.core_1.8.1.jar:na]
- 16:30:59.751 [TRACE] [dbusSlaveConnectionFactoryImpl:78 ] - Created connection SerialConnection@176cbe34[portName=COM6,port=<null>] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:30:59.751 [TRACE] [pi.modbus.net.SerialConnection:128 ] - Got Port Identifier
- 16:30:59.826 [TRACE] [pi.modbus.net.SerialConnection:138 ] - Got Serial Port
- 16:30:59.876 [TRACE] [pi.modbus.net.SerialConnection:174 ] - i/o Streams prepared
- 16:30:59.882 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] -> true
- 16:30:59.883 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave1): borrowing connection (got SerialConnection@176cbe34[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] took 131 ms
- 16:30:59.884 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:00.042 [DEBUG] [.p.internal.PersistenceManager:315 ] - Item 'DemoSwitch' does not exist.
- 16:31:00.043 [DEBUG] [.p.internal.PersistenceManager:315 ] - Item 'NoOfLights' does not exist.
- 16:31:00.044 [DEBUG] [.p.internal.PersistenceManager:315 ] - Item 'Window_GF_Toilet' does not exist.
- 16:31:00.050 [DEBUG] [.p.internal.PersistenceManager:328 ] - Item group 'Heating' does not exist.
- 16:31:00.054 [DEBUG] [.p.internal.PersistenceManager:328 ] - Item group 'Temperature' does not exist.
- 16:31:00.055 [DEBUG] [.p.internal.PersistenceManager:328 ] - Item group 'Weather_Chart' does not exist.
- 16:31:00.294 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:31:00.295 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:00.303 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@754eae95 (unit id 1 & transaction 22). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:00.413 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:00.852 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:31:00.852 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:00.862 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@754eae95 (unit id 1 & transaction 22). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:00.962 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:01.002 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 01 01 02 d0 49
- 16:31:01.012 [INFO ] [w.m.io.ModbusSerialTransaction:213 ] - execute eventually succeeded with 2 re-tries. Request: net.wimpi.modbus.msg.ReadCoilsRequest@754eae95. Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:01.012 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] -> true
- 16:31:01.012 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]...
- 16:31:01.012 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]) age (1131ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:31:01.012 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:31:01.012 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave1): returned connection for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:31:01.012 [TRACE] [et.wimpi.modbus.util.BitVector:141 ] - Get bit #0
- 16:31:01.112 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 100ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6], to ensure delay between transactions.
- 16:31:01.112 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] -> true
- 16:31:01.112 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave2): borrowing connection (got SerialConnection@176cbe34[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] took 100 ms
- 16:31:01.112 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:01.536 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:31:01.536 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:01.546 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@2f510a24 (unit id 1 & transaction 23). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:01.646 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:02.273 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:31:02.273 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:02.283 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@2f510a24 (unit id 1 & transaction 23). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:02.383 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:02.424 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 02 01 02 20 49
- 16:31:02.433 [INFO ] [w.m.io.ModbusSerialTransaction:213 ] - execute eventually succeeded with 2 re-tries. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@2f510a24. Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:02.433 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] -> true
- 16:31:02.433 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]...
- 16:31:02.433 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]) age (2552ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:31:02.433 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:31:02.433 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave2): returned connection for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:31:02.433 [TRACE] [et.wimpi.modbus.util.BitVector:141 ] - Get bit #0
- 16:31:02.533 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 100ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6], to ensure delay between transactions.
- 16:31:02.533 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] -> true
- 16:31:02.533 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave4): borrowing connection (got SerialConnection@176cbe34[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] took 100 ms
- 16:31:02.533 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:02.970 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:31:02.970 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:02.980 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@5d3e8ce4 (unit id 1 & transaction 24). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:03.082 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:03.122 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 03 02 00 00 b8 44
- 16:31:03.132 [INFO ] [w.m.io.ModbusSerialTransaction:213 ] - execute eventually succeeded with 1 re-tries. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@5d3e8ce4. Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:03.132 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] -> true
- 16:31:03.132 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]...
- 16:31:03.132 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]) age (3251ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:31:03.132 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:31:03.132 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave4): returned connection for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:31:03.233 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 90ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6], to ensure delay between transactions.
- 16:31:03.234 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] -> true
- 16:31:03.236 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave1): borrowing connection (got SerialConnection@176cbe34[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] took 94 ms
- 16:31:03.240 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:03.869 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:31:03.869 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:03.879 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@5bfa1fa7 (unit id 1 & transaction 25). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:03.979 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:04.018 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 01 01 02 d0 49
- 16:31:04.028 [INFO ] [w.m.io.ModbusSerialTransaction:213 ] - execute eventually succeeded with 1 re-tries. Request: net.wimpi.modbus.msg.ReadCoilsRequest@5bfa1fa7. Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:04.028 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] -> true
- 16:31:04.028 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]...
- 16:31:04.028 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]) age (4147ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:31:04.028 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:31:04.028 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave1): returned connection for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:31:04.028 [TRACE] [et.wimpi.modbus.util.BitVector:141 ] - Get bit #0
- 16:31:04.128 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 100ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6], to ensure delay between transactions.
- 16:31:04.128 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] -> true
- 16:31:04.128 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave2): borrowing connection (got SerialConnection@176cbe34[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] took 100 ms
- 16:31:04.128 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:04.549 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:31:04.549 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:04.562 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@5b40384b (unit id 1 & transaction 26). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:04.662 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:04.712 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 02 01 02 20 49
- 16:31:04.722 [INFO ] [w.m.io.ModbusSerialTransaction:213 ] - execute eventually succeeded with 1 re-tries. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@5b40384b. Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:04.722 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] -> true
- 16:31:04.722 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]...
- 16:31:04.722 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]) age (4841ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:31:04.722 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:31:04.722 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave2): returned connection for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:31:04.722 [TRACE] [et.wimpi.modbus.util.BitVector:141 ] - Get bit #0
- 16:31:04.828 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 100ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6], to ensure delay between transactions.
- 16:31:04.828 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] -> true
- 16:31:04.828 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave4): borrowing connection (got SerialConnection@176cbe34[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] took 106 ms
- 16:31:04.828 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:05.269 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:31:05.269 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:05.279 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@7ce7192d (unit id 1 & transaction 27). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:05.379 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:05.419 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 03 02 00 00 b8 44
- 16:31:05.429 [INFO ] [w.m.io.ModbusSerialTransaction:213 ] - execute eventually succeeded with 1 re-tries. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@7ce7192d. Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:05.429 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] -> true
- 16:31:05.429 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]...
- 16:31:05.429 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]) age (5548ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:31:05.429 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:31:05.429 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave4): returned connection for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:31:05.530 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 90ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6], to ensure delay between transactions.
- 16:31:05.530 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@176cbe34[portName=COM6,port=//./COM6] -> true
- 16:31:05.530 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave1): borrowing connection (got SerialConnection@176cbe34[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] took 91 ms
- 16:31:05.530 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:05.950 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:31:05.950 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:05.960 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@5597f3f9 (unit id 1 & transaction 28). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:06.060 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:06.484 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:31:06.484 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:06.494 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@5597f3f9 (unit id 1 & transaction 28). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:06.594 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:07.222 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:31:07.223 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:07.231 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@5597f3f9 (unit id 1 & transaction 28). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:07.235 [ERROR] [w.m.io.ModbusSerialTransaction:204 ] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@5597f3f9. Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:07.239 [ERROR] [o.b.m.internal.BaseModbusSlave:412 ] - ModbusSlave (slave1): Error getting modbus data for request net.wimpi.modbus.msg.ReadCoilsRequest@5597f3f9. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]. Connection: SerialConnection@176cbe34[portName=COM6,port=//./COM6]
- 16:31:07.266 [ERROR] [o.b.m.internal.BaseModbusSlave:367 ] - ModbusSlave (slave1) error getting response from slave. Invalidating connection
- java.lang.NullPointerException: null
- at org.openhab.binding.modbus.internal.BaseModbusSlave.update(BaseModbusSlave.java:341) ~[bundlefile:na]
- at org.openhab.binding.modbus.internal.ModbusBinding.execute(ModbusBinding.java:331) [bundlefile:na]
- at org.openhab.core.binding.AbstractActiveBinding$BindingActiveService.execute(AbstractActiveBinding.java:156) [org.openhab.core_1.8.1.jar:na]
- at org.openhab.core.service.AbstractActiveService$RefreshThread.run(AbstractActiveService.java:173) [org.openhab.core_1.8.1.jar:na]
- 16:31:07.274 [TRACE] [dbusSlaveConnectionFactoryImpl:78 ] - Created connection SerialConnection@5e9bc9cb[portName=COM6,port=<null>] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:31:07.276 [TRACE] [pi.modbus.net.SerialConnection:128 ] - Got Port Identifier
- 16:31:07.336 [TRACE] [pi.modbus.net.SerialConnection:138 ] - Got Serial Port
- 16:31:07.365 [TRACE] [pi.modbus.net.SerialConnection:174 ] - i/o Streams prepared
- 16:31:07.366 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] -> true
- 16:31:07.368 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave2): borrowing connection (got SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] took 93 ms
- 16:31:07.369 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:07.798 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:31:07.799 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:07.808 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@40a97fe7 (unit id 1 & transaction 29). Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:07.910 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:07.950 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 02 01 02 20 49
- 16:31:07.960 [INFO ] [w.m.io.ModbusSerialTransaction:213 ] - execute eventually succeeded with 1 re-tries. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@40a97fe7. Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:07.960 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] -> true
- 16:31:07.960 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]...
- 16:31:07.960 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]) age (594ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:31:07.960 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:31:07.960 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave2): returned connection for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:31:07.960 [TRACE] [et.wimpi.modbus.util.BitVector:141 ] - Get bit #0
- 16:31:08.060 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 100ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6], to ensure delay between transactions.
- 16:31:08.061 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] -> true
- 16:31:08.062 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave4): borrowing connection (got SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] took 102 ms
- 16:31:08.064 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:08.099 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 03 02 00 00 b8 44
- 16:31:08.108 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] -> true
- 16:31:08.109 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]...
- 16:31:08.111 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]) age (744ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:31:08.112 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:31:08.113 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave4): returned connection for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:31:08.210 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 91ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6], to ensure delay between transactions.
- 16:31:08.211 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] -> true
- 16:31:08.212 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave1): borrowing connection (got SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] took 93 ms
- 16:31:08.227 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:08.263 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 01 01 02 d0 49
- 16:31:08.272 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] -> true
- 16:31:08.274 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]...
- 16:31:08.276 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]) age (909ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:31:08.277 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:31:08.278 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave1): returned connection for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:31:08.279 [TRACE] [et.wimpi.modbus.util.BitVector:141 ] - Get bit #0
- 16:31:08.375 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 95ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6], to ensure delay between transactions.
- 16:31:08.376 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] -> true
- 16:31:08.377 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave2): borrowing connection (got SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] took 97 ms
- 16:31:08.378 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:08.790 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:31:08.790 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:08.798 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@2acb4430 (unit id 1 & transaction 32). Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:08.907 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:08.947 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 02 01 02 20 49
- 16:31:08.957 [INFO ] [w.m.io.ModbusSerialTransaction:213 ] - execute eventually succeeded with 1 re-tries. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@2acb4430. Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:08.957 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] -> true
- 16:31:08.957 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]...
- 16:31:08.957 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]) age (1591ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:31:08.957 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:31:08.957 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave2): returned connection for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:31:08.957 [TRACE] [et.wimpi.modbus.util.BitVector:141 ] - Get bit #0
- 16:31:09.057 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 100ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6], to ensure delay between transactions.
- 16:31:09.057 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] -> true
- 16:31:09.057 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave4): borrowing connection (got SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] took 100 ms
- 16:31:09.057 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:09.468 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:31:09.469 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:09.478 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@2a1e0533 (unit id 1 & transaction 33). Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:09.579 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:09.616 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 03 02 00 00 b8 f4
- 16:31:09.617 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:31:09.617 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: CRC Error in received frame: 5 bytes: 01 03 02 00 00
- 16:31:09.625 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@2a1e0533 (unit id 1 & transaction 33). Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:09.726 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:09.766 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 03 02 00 00 b8 44
- 16:31:09.776 [INFO ] [w.m.io.ModbusSerialTransaction:213 ] - execute eventually succeeded with 2 re-tries. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@2a1e0533. Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:09.776 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] -> true
- 16:31:09.776 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]...
- 16:31:09.776 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]) age (2410ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:31:09.776 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:31:09.776 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave4): returned connection for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:31:09.876 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 90ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6], to ensure delay between transactions.
- 16:31:09.876 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6] -> true
- 16:31:09.876 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave1): borrowing connection (got SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] took 90 ms
- 16:31:09.876 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:10.506 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:31:10.506 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:10.516 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@37416aeb (unit id 1 & transaction 34). Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:10.618 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:11.051 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:31:11.051 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:11.061 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@37416aeb (unit id 1 & transaction 34). Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:11.161 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:11.590 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:31:11.590 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:11.600 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@37416aeb (unit id 1 & transaction 34). Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:11.600 [ERROR] [w.m.io.ModbusSerialTransaction:204 ] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@37416aeb. Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:11.600 [ERROR] [o.b.m.internal.BaseModbusSlave:412 ] - ModbusSlave (slave1): Error getting modbus data for request net.wimpi.modbus.msg.ReadCoilsRequest@37416aeb. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]. Connection: SerialConnection@5e9bc9cb[portName=COM6,port=//./COM6]
- 16:31:11.660 [ERROR] [o.b.m.internal.BaseModbusSlave:367 ] - ModbusSlave (slave1) error getting response from slave. Invalidating connection
- java.lang.NullPointerException: null
- at org.openhab.binding.modbus.internal.BaseModbusSlave.update(BaseModbusSlave.java:341) ~[bundlefile:na]
- at org.openhab.binding.modbus.internal.ModbusBinding.execute(ModbusBinding.java:331) [bundlefile:na]
- at org.openhab.core.binding.AbstractActiveBinding$BindingActiveService.execute(AbstractActiveBinding.java:156) [org.openhab.core_1.8.1.jar:na]
- at org.openhab.core.service.AbstractActiveService$RefreshThread.run(AbstractActiveService.java:173) [org.openhab.core_1.8.1.jar:na]
- 16:31:11.660 [TRACE] [dbusSlaveConnectionFactoryImpl:78 ] - Created connection SerialConnection@3c1c6da3[portName=COM6,port=<null>] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:31:11.660 [TRACE] [pi.modbus.net.SerialConnection:128 ] - Got Port Identifier
- 16:31:11.750 [TRACE] [pi.modbus.net.SerialConnection:138 ] - Got Serial Port
- 16:31:11.781 [TRACE] [pi.modbus.net.SerialConnection:174 ] - i/o Streams prepared
- 16:31:11.781 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@3c1c6da3[portName=COM6,port=//./COM6] -> true
- 16:31:11.781 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave2): borrowing connection (got SerialConnection@3c1c6da3[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] took 121 ms
- 16:31:11.781 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:12.214 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:31:12.214 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:12.224 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@166be7ea (unit id 1 & transaction 35). Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:12.324 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:12.736 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:31:12.737 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:12.745 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@166be7ea (unit id 1 & transaction 35). Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:12.854 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:13.279 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:31:13.279 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:13.289 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@166be7ea (unit id 1 & transaction 35). Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:13.289 [ERROR] [w.m.io.ModbusSerialTransaction:204 ] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@166be7ea. Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:13.289 [ERROR] [o.b.m.internal.BaseModbusSlave:412 ] - ModbusSlave (slave2): Error getting modbus data for request net.wimpi.modbus.msg.ReadInputDiscretesRequest@166be7ea. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]. Connection: SerialConnection@3c1c6da3[portName=COM6,port=//./COM6]
- 16:31:13.339 [ERROR] [o.b.m.internal.BaseModbusSlave:367 ] - ModbusSlave (slave2) error getting response from slave. Invalidating connection
- java.lang.NullPointerException: null
- at org.openhab.binding.modbus.internal.BaseModbusSlave.update(BaseModbusSlave.java:345) ~[bundlefile:na]
- at org.openhab.binding.modbus.internal.ModbusBinding.execute(ModbusBinding.java:331) [bundlefile:na]
- at org.openhab.core.binding.AbstractActiveBinding$BindingActiveService.execute(AbstractActiveBinding.java:156) [org.openhab.core_1.8.1.jar:na]
- at org.openhab.core.service.AbstractActiveService$RefreshThread.run(AbstractActiveService.java:173) [org.openhab.core_1.8.1.jar:na]
- 16:31:13.349 [TRACE] [dbusSlaveConnectionFactoryImpl:78 ] - Created connection SerialConnection@2ac1c1fe[portName=COM6,port=<null>] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:31:13.349 [TRACE] [pi.modbus.net.SerialConnection:128 ] - Got Port Identifier
- 16:31:13.443 [TRACE] [pi.modbus.net.SerialConnection:138 ] - Got Serial Port
- 16:31:13.469 [TRACE] [pi.modbus.net.SerialConnection:174 ] - i/o Streams prepared
- 16:31:13.498 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@2ac1c1fe[portName=COM6,port=//./COM6] -> true
- 16:31:13.509 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave4): borrowing connection (got SerialConnection@2ac1c1fe[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] took 160 ms
- 16:31:13.511 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:13.920 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:31:13.921 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:13.929 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@b311aed (unit id 1 & transaction 36). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:14.031 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:14.442 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:31:14.443 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:14.452 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@b311aed (unit id 1 & transaction 36). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:14.555 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:14.991 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:31:14.991 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:15.001 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@b311aed (unit id 1 & transaction 36). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:15.001 [ERROR] [w.m.io.ModbusSerialTransaction:204 ] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@b311aed. Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:15.001 [ERROR] [o.b.m.internal.BaseModbusSlave:412 ] - ModbusSlave (slave4): Error getting modbus data for request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@b311aed. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]. Connection: SerialConnection@2ac1c1fe[portName=COM6,port=//./COM6]
- 16:31:15.041 [ERROR] [o.b.m.internal.BaseModbusSlave:367 ] - ModbusSlave (slave4) error getting response from slave. Invalidating connection
- java.lang.NullPointerException: null
- at org.openhab.binding.modbus.internal.BaseModbusSlave.update(BaseModbusSlave.java:349) ~[bundlefile:na]
- at org.openhab.binding.modbus.internal.ModbusBinding.execute(ModbusBinding.java:331) [bundlefile:na]
- at org.openhab.core.binding.AbstractActiveBinding$BindingActiveService.execute(AbstractActiveBinding.java:156) [org.openhab.core_1.8.1.jar:na]
- at org.openhab.core.service.AbstractActiveService$RefreshThread.run(AbstractActiveService.java:173) [org.openhab.core_1.8.1.jar:na]
- 16:31:15.051 [TRACE] [dbusSlaveConnectionFactoryImpl:78 ] - Created connection SerialConnection@422cf8d6[portName=COM6,port=<null>] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:31:15.051 [TRACE] [pi.modbus.net.SerialConnection:128 ] - Got Port Identifier
- 16:31:15.139 [TRACE] [pi.modbus.net.SerialConnection:138 ] - Got Serial Port
- 16:31:15.164 [TRACE] [pi.modbus.net.SerialConnection:174 ] - i/o Streams prepared
- 16:31:15.164 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@422cf8d6[portName=COM6,port=//./COM6] -> true
- 16:31:15.164 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave1): borrowing connection (got SerialConnection@422cf8d6[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] took 113 ms
- 16:31:15.164 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:15.576 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:31:15.578 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:15.586 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@6da12fb4 (unit id 1 & transaction 37). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:15.687 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:15.724 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 01 01 02 d0 49
- 16:31:15.736 [INFO ] [w.m.io.ModbusSerialTransaction:213 ] - execute eventually succeeded with 1 re-tries. Request: net.wimpi.modbus.msg.ReadCoilsRequest@6da12fb4. Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:15.738 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@422cf8d6[portName=COM6,port=//./COM6] -> true
- 16:31:15.739 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@422cf8d6[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]...
- 16:31:15.745 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@422cf8d6[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]) age (580ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:31:15.747 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@422cf8d6[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:31:15.748 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave1): returned connection for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:31:15.750 [TRACE] [et.wimpi.modbus.util.BitVector:141 ] - Get bit #0
- 16:31:15.844 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 94ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@422cf8d6[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6], to ensure delay between transactions.
- 16:31:15.845 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@422cf8d6[portName=COM6,port=//./COM6] -> true
- 16:31:15.846 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave2): borrowing connection (got SerialConnection@422cf8d6[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] took 96 ms
- 16:31:15.847 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:16.284 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:31:16.284 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:16.294 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@6ec4b69f (unit id 1 & transaction 38). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:16.396 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:16.436 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 02 01 02 20 49
- 16:31:16.446 [INFO ] [w.m.io.ModbusSerialTransaction:213 ] - execute eventually succeeded with 1 re-tries. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@6ec4b69f. Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:16.446 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@422cf8d6[portName=COM6,port=//./COM6] -> true
- 16:31:16.446 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@422cf8d6[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]...
- 16:31:16.446 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@422cf8d6[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]) age (1282ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:31:16.446 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@422cf8d6[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:31:16.446 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave2): returned connection for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:31:16.446 [TRACE] [et.wimpi.modbus.util.BitVector:141 ] - Get bit #0
- 16:31:16.546 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 100ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@422cf8d6[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6], to ensure delay between transactions.
- 16:31:16.546 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@422cf8d6[portName=COM6,port=//./COM6] -> true
- 16:31:16.546 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave4): borrowing connection (got SerialConnection@422cf8d6[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] took 100 ms
- 16:31:16.546 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:16.960 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:31:16.962 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:16.970 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@4b0b09d9 (unit id 1 & transaction 39). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:17.080 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:17.505 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:31:17.505 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:17.515 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@4b0b09d9 (unit id 1 & transaction 39). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:17.615 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:17.655 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 03 02 00 00 b8 44
- 16:31:17.665 [INFO ] [w.m.io.ModbusSerialTransaction:213 ] - execute eventually succeeded with 2 re-tries. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@4b0b09d9. Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:17.665 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@422cf8d6[portName=COM6,port=//./COM6] -> true
- 16:31:17.665 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@422cf8d6[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]...
- 16:31:17.665 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@422cf8d6[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]) age (2501ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:31:17.665 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@422cf8d6[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:31:17.665 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave4): returned connection for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:31:17.765 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 90ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@422cf8d6[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6], to ensure delay between transactions.
- 16:31:17.770 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@422cf8d6[portName=COM6,port=//./COM6] -> true
- 16:31:17.774 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave1): borrowing connection (got SerialConnection@422cf8d6[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] took 99 ms
- 16:31:17.776 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:17.815 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 01 01 02 d0 49
- 16:31:17.824 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@422cf8d6[portName=COM6,port=//./COM6] -> true
- 16:31:17.825 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@422cf8d6[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]...
- 16:31:17.826 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@422cf8d6[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]) age (2662ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:31:17.827 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@422cf8d6[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:31:17.828 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave1): returned connection for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:31:17.830 [TRACE] [et.wimpi.modbus.util.BitVector:141 ] - Get bit #0
- 16:31:17.926 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 95ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@422cf8d6[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6], to ensure delay between transactions.
- 16:31:17.931 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@422cf8d6[portName=COM6,port=//./COM6] -> true
- 16:31:17.932 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave2): borrowing connection (got SerialConnection@422cf8d6[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] took 101 ms
- 16:31:17.934 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:18.359 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:31:18.359 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:18.369 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@1de1c30b (unit id 1 & transaction 41). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:18.470 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:18.882 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:31:18.883 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:18.891 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@1de1c30b (unit id 1 & transaction 41). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:18.994 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:19.404 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:31:19.405 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:19.413 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@1de1c30b (unit id 1 & transaction 41). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:19.414 [ERROR] [w.m.io.ModbusSerialTransaction:204 ] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@1de1c30b. Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:19.416 [ERROR] [o.b.m.internal.BaseModbusSlave:412 ] - ModbusSlave (slave2): Error getting modbus data for request net.wimpi.modbus.msg.ReadInputDiscretesRequest@1de1c30b. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]. Connection: SerialConnection@422cf8d6[portName=COM6,port=//./COM6]
- 16:31:19.441 [ERROR] [o.b.m.internal.BaseModbusSlave:367 ] - ModbusSlave (slave2) error getting response from slave. Invalidating connection
- java.lang.NullPointerException: null
- at org.openhab.binding.modbus.internal.BaseModbusSlave.update(BaseModbusSlave.java:345) ~[bundlefile:na]
- at org.openhab.binding.modbus.internal.ModbusBinding.execute(ModbusBinding.java:331) [bundlefile:na]
- at org.openhab.core.binding.AbstractActiveBinding$BindingActiveService.execute(AbstractActiveBinding.java:156) [org.openhab.core_1.8.1.jar:na]
- at org.openhab.core.service.AbstractActiveService$RefreshThread.run(AbstractActiveService.java:173) [org.openhab.core_1.8.1.jar:na]
- 16:31:19.443 [TRACE] [dbusSlaveConnectionFactoryImpl:78 ] - Created connection SerialConnection@7959938c[portName=COM6,port=<null>] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:31:19.444 [TRACE] [pi.modbus.net.SerialConnection:128 ] - Got Port Identifier
- 16:31:19.511 [TRACE] [pi.modbus.net.SerialConnection:138 ] - Got Serial Port
- 16:31:19.540 [TRACE] [pi.modbus.net.SerialConnection:174 ] - i/o Streams prepared
- 16:31:19.541 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@7959938c[portName=COM6,port=//./COM6] -> true
- 16:31:19.543 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave4): borrowing connection (got SerialConnection@7959938c[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] took 100 ms
- 16:31:19.550 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:19.960 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:31:19.961 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:19.969 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@21343032 (unit id 1 & transaction 42). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:20.070 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:20.480 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:31:20.482 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:20.490 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@21343032 (unit id 1 & transaction 42). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:20.591 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:21.002 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:31:21.004 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:21.011 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@21343032 (unit id 1 & transaction 42). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:21.018 [ERROR] [w.m.io.ModbusSerialTransaction:204 ] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@21343032. Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:21.019 [ERROR] [o.b.m.internal.BaseModbusSlave:412 ] - ModbusSlave (slave4): Error getting modbus data for request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@21343032. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]. Connection: SerialConnection@7959938c[portName=COM6,port=//./COM6]
- 16:31:21.044 [ERROR] [o.b.m.internal.BaseModbusSlave:367 ] - ModbusSlave (slave4) error getting response from slave. Invalidating connection
- java.lang.NullPointerException: null
- at org.openhab.binding.modbus.internal.BaseModbusSlave.update(BaseModbusSlave.java:349) ~[bundlefile:na]
- at org.openhab.binding.modbus.internal.ModbusBinding.execute(ModbusBinding.java:331) [bundlefile:na]
- at org.openhab.core.binding.AbstractActiveBinding$BindingActiveService.execute(AbstractActiveBinding.java:156) [org.openhab.core_1.8.1.jar:na]
- at org.openhab.core.service.AbstractActiveService$RefreshThread.run(AbstractActiveService.java:173) [org.openhab.core_1.8.1.jar:na]
- 16:31:21.056 [TRACE] [dbusSlaveConnectionFactoryImpl:78 ] - Created connection SerialConnection@32de5684[portName=COM6,port=<null>] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:31:21.058 [TRACE] [pi.modbus.net.SerialConnection:128 ] - Got Port Identifier
- 16:31:21.118 [TRACE] [pi.modbus.net.SerialConnection:138 ] - Got Serial Port
- 16:31:21.143 [TRACE] [pi.modbus.net.SerialConnection:174 ] - i/o Streams prepared
- 16:31:21.144 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@32de5684[portName=COM6,port=//./COM6] -> true
- 16:31:21.144 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave1): borrowing connection (got SerialConnection@32de5684[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] took 88 ms
- 16:31:21.146 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:21.556 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:31:21.557 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:21.566 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@20f89531 (unit id 1 & transaction 43). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:21.668 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:22.088 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:31:22.092 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:22.103 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@20f89531 (unit id 1 & transaction 43). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:22.218 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:22.257 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 01 01 02 d0 49
- 16:31:22.266 [INFO ] [w.m.io.ModbusSerialTransaction:213 ] - execute eventually succeeded with 2 re-tries. Request: net.wimpi.modbus.msg.ReadCoilsRequest@20f89531. Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:22.267 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@32de5684[portName=COM6,port=//./COM6] -> true
- 16:31:22.268 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@32de5684[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]...
- 16:31:22.269 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@32de5684[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]) age (1126ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:31:22.270 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@32de5684[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:31:22.270 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave1): returned connection for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:31:22.271 [TRACE] [et.wimpi.modbus.util.BitVector:141 ] - Get bit #0
- 16:31:22.369 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 97ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@32de5684[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6], to ensure delay between transactions.
- 16:31:22.370 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@32de5684[portName=COM6,port=//./COM6] -> true
- 16:31:22.371 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave2): borrowing connection (got SerialConnection@32de5684[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] took 99 ms
- 16:31:22.371 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:22.783 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:31:22.783 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:22.797 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@20cd84bc (unit id 1 & transaction 44). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:22.897 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:23.309 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:31:23.309 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:23.317 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@20cd84bc (unit id 1 & transaction 44). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:23.426 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:24.038 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:31:24.038 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:24.046 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@20cd84bc (unit id 1 & transaction 44). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:24.051 [ERROR] [w.m.io.ModbusSerialTransaction:204 ] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@20cd84bc. Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:24.052 [ERROR] [o.b.m.internal.BaseModbusSlave:412 ] - ModbusSlave (slave2): Error getting modbus data for request net.wimpi.modbus.msg.ReadInputDiscretesRequest@20cd84bc. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]. Connection: SerialConnection@32de5684[portName=COM6,port=//./COM6]
- 16:31:24.079 [ERROR] [o.b.m.internal.BaseModbusSlave:367 ] - ModbusSlave (slave2) error getting response from slave. Invalidating connection
- java.lang.NullPointerException: null
- at org.openhab.binding.modbus.internal.BaseModbusSlave.update(BaseModbusSlave.java:345) ~[bundlefile:na]
- at org.openhab.binding.modbus.internal.ModbusBinding.execute(ModbusBinding.java:331) [bundlefile:na]
- at org.openhab.core.binding.AbstractActiveBinding$BindingActiveService.execute(AbstractActiveBinding.java:156) [org.openhab.core_1.8.1.jar:na]
- at org.openhab.core.service.AbstractActiveService$RefreshThread.run(AbstractActiveService.java:173) [org.openhab.core_1.8.1.jar:na]
- 16:31:24.085 [TRACE] [dbusSlaveConnectionFactoryImpl:78 ] - Created connection SerialConnection@70bd2330[portName=COM6,port=<null>] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:31:24.086 [TRACE] [pi.modbus.net.SerialConnection:128 ] - Got Port Identifier
- 16:31:24.146 [TRACE] [pi.modbus.net.SerialConnection:138 ] - Got Serial Port
- 16:31:24.177 [TRACE] [pi.modbus.net.SerialConnection:174 ] - i/o Streams prepared
- 16:31:24.177 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@70bd2330[portName=COM6,port=//./COM6] -> true
- 16:31:24.177 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave4): borrowing connection (got SerialConnection@70bd2330[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] took 92 ms
- 16:31:24.177 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:24.603 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:31:24.603 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:24.613 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@60c0870f (unit id 1 & transaction 45). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:24.714 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:25.144 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:31:25.144 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:25.154 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@60c0870f (unit id 1 & transaction 45). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:25.258 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:25.697 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:31:25.697 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:25.707 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@60c0870f (unit id 1 & transaction 45). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:25.707 [ERROR] [w.m.io.ModbusSerialTransaction:204 ] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@60c0870f. Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:25.707 [ERROR] [o.b.m.internal.BaseModbusSlave:412 ] - ModbusSlave (slave4): Error getting modbus data for request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@60c0870f. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]. Connection: SerialConnection@70bd2330[portName=COM6,port=//./COM6]
- 16:31:25.758 [ERROR] [o.b.m.internal.BaseModbusSlave:367 ] - ModbusSlave (slave4) error getting response from slave. Invalidating connection
- java.lang.NullPointerException: null
- at org.openhab.binding.modbus.internal.BaseModbusSlave.update(BaseModbusSlave.java:349) ~[bundlefile:na]
- at org.openhab.binding.modbus.internal.ModbusBinding.execute(ModbusBinding.java:331) [bundlefile:na]
- at org.openhab.core.binding.AbstractActiveBinding$BindingActiveService.execute(AbstractActiveBinding.java:156) [org.openhab.core_1.8.1.jar:na]
- at org.openhab.core.service.AbstractActiveService$RefreshThread.run(AbstractActiveService.java:173) [org.openhab.core_1.8.1.jar:na]
- 16:31:25.765 [TRACE] [dbusSlaveConnectionFactoryImpl:78 ] - Created connection SerialConnection@37f3ea1f[portName=COM6,port=<null>] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:31:25.766 [TRACE] [pi.modbus.net.SerialConnection:128 ] - Got Port Identifier
- 16:31:25.826 [TRACE] [pi.modbus.net.SerialConnection:138 ] - Got Serial Port
- 16:31:25.854 [TRACE] [pi.modbus.net.SerialConnection:174 ] - i/o Streams prepared
- 16:31:25.861 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@37f3ea1f[portName=COM6,port=//./COM6] -> true
- 16:31:25.865 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave1): borrowing connection (got SerialConnection@37f3ea1f[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] took 100 ms
- 16:31:25.870 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:26.487 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:31:26.490 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:26.500 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@5f29310d (unit id 1 & transaction 46). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:26.601 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:27.033 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:31:27.037 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:27.050 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@5f29310d (unit id 1 & transaction 46). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:27.152 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:27.573 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:31:27.573 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:27.583 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@5f29310d (unit id 1 & transaction 46). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:27.583 [ERROR] [w.m.io.ModbusSerialTransaction:204 ] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@5f29310d. Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:27.583 [ERROR] [o.b.m.internal.BaseModbusSlave:412 ] - ModbusSlave (slave1): Error getting modbus data for request net.wimpi.modbus.msg.ReadCoilsRequest@5f29310d. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]. Connection: SerialConnection@37f3ea1f[portName=COM6,port=//./COM6]
- 16:31:27.613 [ERROR] [o.b.m.internal.BaseModbusSlave:367 ] - ModbusSlave (slave1) error getting response from slave. Invalidating connection
- java.lang.NullPointerException: null
- at org.openhab.binding.modbus.internal.BaseModbusSlave.update(BaseModbusSlave.java:341) ~[bundlefile:na]
- at org.openhab.binding.modbus.internal.ModbusBinding.execute(ModbusBinding.java:331) [bundlefile:na]
- at org.openhab.core.binding.AbstractActiveBinding$BindingActiveService.execute(AbstractActiveBinding.java:156) [org.openhab.core_1.8.1.jar:na]
- at org.openhab.core.service.AbstractActiveService$RefreshThread.run(AbstractActiveService.java:173) [org.openhab.core_1.8.1.jar:na]
- 16:31:27.613 [TRACE] [dbusSlaveConnectionFactoryImpl:78 ] - Created connection SerialConnection@3b352d18[portName=COM6,port=<null>] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:31:27.613 [TRACE] [pi.modbus.net.SerialConnection:128 ] - Got Port Identifier
- 16:31:27.703 [TRACE] [pi.modbus.net.SerialConnection:138 ] - Got Serial Port
- 16:31:27.734 [TRACE] [pi.modbus.net.SerialConnection:174 ] - i/o Streams prepared
- 16:31:27.734 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@3b352d18[portName=COM6,port=//./COM6] -> true
- 16:31:27.734 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave2): borrowing connection (got SerialConnection@3b352d18[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] took 121 ms
- 16:31:27.734 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:28.170 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:31:28.170 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:28.180 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@4a72671d (unit id 1 & transaction 47). Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:28.280 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:28.903 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:31:28.903 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:28.912 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@4a72671d (unit id 1 & transaction 47). Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:29.022 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:29.452 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:31:29.452 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:29.462 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@4a72671d (unit id 1 & transaction 47). Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:29.462 [ERROR] [w.m.io.ModbusSerialTransaction:204 ] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@4a72671d. Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:29.462 [ERROR] [o.b.m.internal.BaseModbusSlave:412 ] - ModbusSlave (slave2): Error getting modbus data for request net.wimpi.modbus.msg.ReadInputDiscretesRequest@4a72671d. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]. Connection: SerialConnection@3b352d18[portName=COM6,port=//./COM6]
- 16:31:29.532 [ERROR] [o.b.m.internal.BaseModbusSlave:367 ] - ModbusSlave (slave2) error getting response from slave. Invalidating connection
- java.lang.NullPointerException: null
- at org.openhab.binding.modbus.internal.BaseModbusSlave.update(BaseModbusSlave.java:345) ~[bundlefile:na]
- at org.openhab.binding.modbus.internal.ModbusBinding.execute(ModbusBinding.java:331) [bundlefile:na]
- at org.openhab.core.binding.AbstractActiveBinding$BindingActiveService.execute(AbstractActiveBinding.java:156) [org.openhab.core_1.8.1.jar:na]
- at org.openhab.core.service.AbstractActiveService$RefreshThread.run(AbstractActiveService.java:173) [org.openhab.core_1.8.1.jar:na]
- 16:31:29.532 [TRACE] [dbusSlaveConnectionFactoryImpl:78 ] - Created connection SerialConnection@5c459607[portName=COM6,port=<null>] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:31:29.532 [TRACE] [pi.modbus.net.SerialConnection:128 ] - Got Port Identifier
- 16:31:29.632 [TRACE] [pi.modbus.net.SerialConnection:138 ] - Got Serial Port
- 16:31:29.663 [TRACE] [pi.modbus.net.SerialConnection:174 ] - i/o Streams prepared
- 16:31:29.663 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@5c459607[portName=COM6,port=//./COM6] -> true
- 16:31:29.663 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave4): borrowing connection (got SerialConnection@5c459607[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] took 131 ms
- 16:31:29.663 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:30.084 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:31:30.084 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:30.094 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@2908d2db (unit id 1 & transaction 48). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:30.194 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:30.615 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:31:30.615 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:30.625 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@2908d2db (unit id 1 & transaction 48). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:30.725 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:31.146 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:31:31.146 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:31.156 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@2908d2db (unit id 1 & transaction 48). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:31.156 [ERROR] [w.m.io.ModbusSerialTransaction:204 ] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@2908d2db. Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:31.156 [ERROR] [o.b.m.internal.BaseModbusSlave:412 ] - ModbusSlave (slave4): Error getting modbus data for request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@2908d2db. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]. Connection: SerialConnection@5c459607[portName=COM6,port=//./COM6]
- 16:31:31.226 [ERROR] [o.b.m.internal.BaseModbusSlave:367 ] - ModbusSlave (slave4) error getting response from slave. Invalidating connection
- java.lang.NullPointerException: null
- at org.openhab.binding.modbus.internal.BaseModbusSlave.update(BaseModbusSlave.java:349) ~[bundlefile:na]
- at org.openhab.binding.modbus.internal.ModbusBinding.execute(ModbusBinding.java:331) [bundlefile:na]
- at org.openhab.core.binding.AbstractActiveBinding$BindingActiveService.execute(AbstractActiveBinding.java:156) [org.openhab.core_1.8.1.jar:na]
- at org.openhab.core.service.AbstractActiveService$RefreshThread.run(AbstractActiveService.java:173) [org.openhab.core_1.8.1.jar:na]
- 16:31:31.236 [TRACE] [dbusSlaveConnectionFactoryImpl:78 ] - Created connection SerialConnection@709b1268[portName=COM6,port=<null>] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:31:31.236 [TRACE] [pi.modbus.net.SerialConnection:128 ] - Got Port Identifier
- 16:31:31.327 [TRACE] [pi.modbus.net.SerialConnection:138 ] - Got Serial Port
- 16:31:31.358 [TRACE] [pi.modbus.net.SerialConnection:174 ] - i/o Streams prepared
- 16:31:31.358 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@709b1268[portName=COM6,port=//./COM6] -> true
- 16:31:31.358 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave1): borrowing connection (got SerialConnection@709b1268[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] took 122 ms
- 16:31:31.358 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:31.991 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:31:31.991 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:32.001 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@1fe0db56 (unit id 1 & transaction 49). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:32.101 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:32.531 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:31:32.531 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:32.541 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@1fe0db56 (unit id 1 & transaction 49). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:32.641 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:33.083 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:31:33.083 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:33.093 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@1fe0db56 (unit id 1 & transaction 49). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:33.093 [ERROR] [w.m.io.ModbusSerialTransaction:204 ] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@1fe0db56. Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:33.093 [ERROR] [o.b.m.internal.BaseModbusSlave:412 ] - ModbusSlave (slave1): Error getting modbus data for request net.wimpi.modbus.msg.ReadCoilsRequest@1fe0db56. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]. Connection: SerialConnection@709b1268[portName=COM6,port=//./COM6]
- 16:31:33.143 [ERROR] [o.b.m.internal.BaseModbusSlave:367 ] - ModbusSlave (slave1) error getting response from slave. Invalidating connection
- java.lang.NullPointerException: null
- at org.openhab.binding.modbus.internal.BaseModbusSlave.update(BaseModbusSlave.java:341) ~[bundlefile:na]
- at org.openhab.binding.modbus.internal.ModbusBinding.execute(ModbusBinding.java:331) [bundlefile:na]
- at org.openhab.core.binding.AbstractActiveBinding$BindingActiveService.execute(AbstractActiveBinding.java:156) [org.openhab.core_1.8.1.jar:na]
- at org.openhab.core.service.AbstractActiveService$RefreshThread.run(AbstractActiveService.java:173) [org.openhab.core_1.8.1.jar:na]
- 16:31:33.143 [TRACE] [dbusSlaveConnectionFactoryImpl:78 ] - Created connection SerialConnection@70114c7b[portName=COM6,port=<null>] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:31:33.143 [TRACE] [pi.modbus.net.SerialConnection:128 ] - Got Port Identifier
- 16:31:33.233 [TRACE] [pi.modbus.net.SerialConnection:138 ] - Got Serial Port
- 16:31:33.264 [TRACE] [pi.modbus.net.SerialConnection:174 ] - i/o Streams prepared
- 16:31:33.264 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@70114c7b[portName=COM6,port=//./COM6] -> true
- 16:31:33.264 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave2): borrowing connection (got SerialConnection@70114c7b[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] took 121 ms
- 16:31:33.264 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:33.698 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:31:33.698 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:33.708 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@2ae3f450 (unit id 1 & transaction 50). Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:33.815 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:34.235 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:31:34.235 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:34.245 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@2ae3f450 (unit id 1 & transaction 50). Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:34.345 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:34.776 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:31:34.776 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:34.786 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@2ae3f450 (unit id 1 & transaction 50). Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:34.786 [ERROR] [w.m.io.ModbusSerialTransaction:204 ] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@2ae3f450. Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:34.786 [ERROR] [o.b.m.internal.BaseModbusSlave:412 ] - ModbusSlave (slave2): Error getting modbus data for request net.wimpi.modbus.msg.ReadInputDiscretesRequest@2ae3f450. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]. Connection: SerialConnection@70114c7b[portName=COM6,port=//./COM6]
- 16:31:34.826 [ERROR] [o.b.m.internal.BaseModbusSlave:367 ] - ModbusSlave (slave2) error getting response from slave. Invalidating connection
- java.lang.NullPointerException: null
- at org.openhab.binding.modbus.internal.BaseModbusSlave.update(BaseModbusSlave.java:345) ~[bundlefile:na]
- at org.openhab.binding.modbus.internal.ModbusBinding.execute(ModbusBinding.java:331) [bundlefile:na]
- at org.openhab.core.binding.AbstractActiveBinding$BindingActiveService.execute(AbstractActiveBinding.java:156) [org.openhab.core_1.8.1.jar:na]
- at org.openhab.core.service.AbstractActiveService$RefreshThread.run(AbstractActiveService.java:173) [org.openhab.core_1.8.1.jar:na]
- 16:31:34.836 [TRACE] [dbusSlaveConnectionFactoryImpl:78 ] - Created connection SerialConnection@33c0b031[portName=COM6,port=<null>] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:31:34.836 [TRACE] [pi.modbus.net.SerialConnection:128 ] - Got Port Identifier
- 16:31:34.926 [TRACE] [pi.modbus.net.SerialConnection:138 ] - Got Serial Port
- 16:31:34.957 [TRACE] [pi.modbus.net.SerialConnection:174 ] - i/o Streams prepared
- 16:31:34.957 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@33c0b031[portName=COM6,port=//./COM6] -> true
- 16:31:34.957 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave4): borrowing connection (got SerialConnection@33c0b031[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] took 121 ms
- 16:31:34.957 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:35.387 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:31:35.387 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:35.397 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@196bbacc (unit id 1 & transaction 51). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:35.497 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:35.927 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:31:35.927 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:35.937 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@196bbacc (unit id 1 & transaction 51). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:36.037 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:36.077 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 03 02 00 00 b8 44
- 16:31:36.087 [INFO ] [w.m.io.ModbusSerialTransaction:213 ] - execute eventually succeeded with 2 re-tries. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@196bbacc. Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:36.087 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@33c0b031[portName=COM6,port=//./COM6] -> true
- 16:31:36.087 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@33c0b031[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]...
- 16:31:36.087 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@33c0b031[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]) age (1130ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:31:36.087 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@33c0b031[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:31:36.087 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave4): returned connection for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:31:36.188 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 90ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@33c0b031[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6], to ensure delay between transactions.
- 16:31:36.188 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@33c0b031[portName=COM6,port=//./COM6] -> true
- 16:31:36.188 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave1): borrowing connection (got SerialConnection@33c0b031[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] took 91 ms
- 16:31:36.188 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:36.228 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 01 01 02 d0 49
- 16:31:36.238 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@33c0b031[portName=COM6,port=//./COM6] -> true
- 16:31:36.238 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@33c0b031[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]...
- 16:31:36.238 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@33c0b031[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]) age (1281ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:31:36.238 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@33c0b031[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:31:36.238 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave1): returned connection for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:31:36.238 [TRACE] [et.wimpi.modbus.util.BitVector:141 ] - Get bit #0
- 16:31:36.338 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 100ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@33c0b031[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6], to ensure delay between transactions.
- 16:31:36.338 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@33c0b031[portName=COM6,port=//./COM6] -> true
- 16:31:36.338 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave2): borrowing connection (got SerialConnection@33c0b031[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] took 100 ms
- 16:31:36.338 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:36.768 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:31:36.768 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:36.778 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@2c9f9cc5 (unit id 1 & transaction 53). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:36.878 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:36.918 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 02 01 02 20 49
- 16:31:36.928 [INFO ] [w.m.io.ModbusSerialTransaction:213 ] - execute eventually succeeded with 1 re-tries. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@2c9f9cc5. Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:36.928 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@33c0b031[portName=COM6,port=//./COM6] -> true
- 16:31:36.928 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@33c0b031[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]...
- 16:31:36.928 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@33c0b031[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]) age (1971ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:31:36.928 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@33c0b031[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:31:36.928 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave2): returned connection for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:31:36.928 [TRACE] [et.wimpi.modbus.util.BitVector:141 ] - Get bit #0
- 16:31:37.028 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 100ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@33c0b031[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6], to ensure delay between transactions.
- 16:31:37.028 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@33c0b031[portName=COM6,port=//./COM6] -> true
- 16:31:37.028 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave4): borrowing connection (got SerialConnection@33c0b031[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] took 100 ms
- 16:31:37.028 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:37.448 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:31:37.448 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:37.458 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@1a68e05f (unit id 1 & transaction 54). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:37.558 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:37.978 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:31:37.978 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:37.988 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@1a68e05f (unit id 1 & transaction 54). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:38.088 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:38.513 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:31:38.513 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:38.523 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@1a68e05f (unit id 1 & transaction 54). Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:38.523 [ERROR] [w.m.io.ModbusSerialTransaction:204 ] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@1a68e05f. Serial parameters: SerialParameters@65fa20f4[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:38.523 [ERROR] [o.b.m.internal.BaseModbusSlave:412 ] - ModbusSlave (slave4): Error getting modbus data for request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@1a68e05f. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]. Connection: SerialConnection@33c0b031[portName=COM6,port=//./COM6]
- 16:31:38.573 [ERROR] [o.b.m.internal.BaseModbusSlave:367 ] - ModbusSlave (slave4) error getting response from slave. Invalidating connection
- java.lang.NullPointerException: null
- at org.openhab.binding.modbus.internal.BaseModbusSlave.update(BaseModbusSlave.java:349) ~[bundlefile:na]
- at org.openhab.binding.modbus.internal.ModbusBinding.execute(ModbusBinding.java:331) [bundlefile:na]
- at org.openhab.core.binding.AbstractActiveBinding$BindingActiveService.execute(AbstractActiveBinding.java:156) [org.openhab.core_1.8.1.jar:na]
- at org.openhab.core.service.AbstractActiveService$RefreshThread.run(AbstractActiveService.java:173) [org.openhab.core_1.8.1.jar:na]
- 16:31:38.583 [TRACE] [dbusSlaveConnectionFactoryImpl:78 ] - Created connection SerialConnection@112ecec4[portName=COM6,port=<null>] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:31:38.583 [TRACE] [pi.modbus.net.SerialConnection:128 ] - Got Port Identifier
- 16:31:38.674 [TRACE] [pi.modbus.net.SerialConnection:138 ] - Got Serial Port
- 16:31:38.705 [TRACE] [pi.modbus.net.SerialConnection:174 ] - i/o Streams prepared
- 16:31:38.705 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@112ecec4[portName=COM6,port=//./COM6] -> true
- 16:31:38.705 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave1): borrowing connection (got SerialConnection@112ecec4[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] took 122 ms
- 16:31:38.705 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:39.335 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:31:39.335 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:39.345 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@5fe7c2c (unit id 1 & transaction 55). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:39.445 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:39.865 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:31:39.865 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:39.875 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@5fe7c2c (unit id 1 & transaction 55). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:39.975 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:40.397 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:31:40.397 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:40.407 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@5fe7c2c (unit id 1 & transaction 55). Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:40.407 [ERROR] [w.m.io.ModbusSerialTransaction:204 ] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@5fe7c2c. Serial parameters: SerialParameters@114a18fb[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:40.407 [ERROR] [o.b.m.internal.BaseModbusSlave:412 ] - ModbusSlave (slave1): Error getting modbus data for request net.wimpi.modbus.msg.ReadCoilsRequest@5fe7c2c. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]. Connection: SerialConnection@112ecec4[portName=COM6,port=//./COM6]
- 16:31:40.457 [ERROR] [o.b.m.internal.BaseModbusSlave:367 ] - ModbusSlave (slave1) error getting response from slave. Invalidating connection
- java.lang.NullPointerException: null
- at org.openhab.binding.modbus.internal.BaseModbusSlave.update(BaseModbusSlave.java:341) ~[bundlefile:na]
- at org.openhab.binding.modbus.internal.ModbusBinding.execute(ModbusBinding.java:331) [bundlefile:na]
- at org.openhab.core.binding.AbstractActiveBinding$BindingActiveService.execute(AbstractActiveBinding.java:156) [org.openhab.core_1.8.1.jar:na]
- at org.openhab.core.service.AbstractActiveService$RefreshThread.run(AbstractActiveService.java:173) [org.openhab.core_1.8.1.jar:na]
- 16:31:40.457 [TRACE] [dbusSlaveConnectionFactoryImpl:78 ] - Created connection SerialConnection@58491ed4[portName=COM6,port=<null>] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:31:40.457 [TRACE] [pi.modbus.net.SerialConnection:128 ] - Got Port Identifier
- 16:31:40.547 [TRACE] [pi.modbus.net.SerialConnection:138 ] - Got Serial Port
- 16:31:40.578 [TRACE] [pi.modbus.net.SerialConnection:174 ] - i/o Streams prepared
- 16:31:40.578 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] -> true
- 16:31:40.578 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave2): borrowing connection (got SerialConnection@58491ed4[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] took 121 ms
- 16:31:40.578 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:41.208 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:31:41.208 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:41.218 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@57963ffd (unit id 1 & transaction 56). Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:41.318 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:41.738 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 02 00 02 00 01 18 0a
- 16:31:41.738 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:41.748 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@57963ffd (unit id 1 & transaction 56). Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:41.848 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:41.888 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 02 01 02 20 49
- 16:31:41.898 [INFO ] [w.m.io.ModbusSerialTransaction:213 ] - execute eventually succeeded with 2 re-tries. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@57963ffd. Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:41.898 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] -> true
- 16:31:41.898 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]...
- 16:31:41.898 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]) age (1320ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:31:41.898 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:31:41.898 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave2): returned connection for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:31:41.898 [TRACE] [et.wimpi.modbus.util.BitVector:141 ] - Get bit #0
- 16:31:41.998 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 100ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6], to ensure delay between transactions.
- 16:31:41.998 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] -> true
- 16:31:41.998 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave4): borrowing connection (got SerialConnection@58491ed4[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] took 100 ms
- 16:31:41.998 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:42.432 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 03 00 01 00 01 d5 ca
- 16:31:42.432 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:42.443 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@21ff363f (unit id 1 & transaction 57). Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:42.543 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:42.583 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 03 02 00 00 b8 44
- 16:31:42.593 [INFO ] [w.m.io.ModbusSerialTransaction:213 ] - execute eventually succeeded with 1 re-tries. Request: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@21ff363f. Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:42.593 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] -> true
- 16:31:42.593 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]...
- 16:31:42.593 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]) age (2015ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:31:42.593 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:31:42.593 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave4): returned connection for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:31:42.694 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 90ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6], to ensure delay between transactions.
- 16:31:42.694 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] -> true
- 16:31:42.694 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave1): borrowing connection (got SerialConnection@58491ed4[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] took 91 ms
- 16:31:42.694 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:43.135 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:31:43.135 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:43.145 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@3150336a (unit id 1 & transaction 58). Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:43.245 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:43.877 [ERROR] [i.modbus.io.ModbusRTUTransport:170 ] - Last request: 01 01 00 02 00 01 5c 0a
- 16:31:43.877 [ERROR] [i.modbus.io.ModbusRTUTransport:171 ] - failed to read: Error reading response (EOF)
- 16:31:43.887 [ERROR] [w.m.io.ModbusSerialTransaction:199 ] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadCoilsRequest@3150336a (unit id 1 & transaction 58). Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:43.987 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 01 00 02 00 01 5c 0a
- 16:31:44.027 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 01 01 02 d0 49
- 16:31:44.037 [INFO ] [w.m.io.ModbusSerialTransaction:213 ] - execute eventually succeeded with 2 re-tries. Request: net.wimpi.modbus.msg.ReadCoilsRequest@3150336a. Serial parameters: SerialParameters@6c5ebd4f[portName=COM6,baudRate=38400,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=none,encoding=rtu,echo=false,receiveTimeoutMillis=280]
- 16:31:44.037 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6] connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] -> true
- 16:31:44.037 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]...
- 16:31:44.037 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]) age (3459ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:31:44.037 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:31:44.037 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave1): returned connection for endpoint ModbusSerialSlaveEndpoint@70c77d33[portName=COM6]
- 16:31:44.037 [TRACE] [et.wimpi.modbus.util.BitVector:141 ] - Get bit #0
- 16:31:44.137 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 100ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6], to ensure delay between transactions.
- 16:31:44.137 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] -> true
- 16:31:44.137 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave2): borrowing connection (got SerialConnection@58491ed4[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] took 100 ms
- 16:31:44.137 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 02 00 02 00 01 18 0a
- 16:31:44.177 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 02 01 02 20 49
- 16:31:44.187 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6] connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] -> true
- 16:31:44.187 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]...
- 16:31:44.187 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]) age (3609ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:31:44.187 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:31:44.187 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave2): returned connection for endpoint ModbusSerialSlaveEndpoint@7ae043d6[portName=COM6]
- 16:31:44.187 [TRACE] [et.wimpi.modbus.util.BitVector:141 ] - Get bit #0
- 16:31:44.287 [TRACE] [dbusSlaveConnectionFactoryImpl:128 ] - Waited 100ms (passivateBorrowMinMillis 100ms) before giving returning connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6], to ensure delay between transactions.
- 16:31:44.287 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] -> true
- 16:31:44.287 [TRACE] [o.b.m.internal.BaseModbusSlave:292 ] - ModbusSlave (slave4): borrowing connection (got SerialConnection@58491ed4[portName=COM6,port=//./COM6]) for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] took 100 ms
- 16:31:44.287 [DEBUG] [i.modbus.io.ModbusRTUTransport:77 ] - Sent: 01 03 00 01 00 01 d5 ca
- 16:31:44.327 [DEBUG] [i.modbus.io.ModbusRTUTransport:144 ] - Response: 01 03 02 00 00 b8 44
- 16:31:44.337 [TRACE] [dbusSlaveConnectionFactoryImpl:169 ] - Validating endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6] connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] -> true
- 16:31:44.337 [TRACE] [dbusSlaveConnectionFactoryImpl:148 ] - Passivating connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]...
- 16:31:44.337 [TRACE] [dbusSlaveConnectionFactoryImpl:159 ] - (passivate) Connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] (endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]) age (3759ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
- 16:31:44.337 [TRACE] [dbusSlaveConnectionFactoryImpl:163 ] - ...Passivated connection SerialConnection@58491ed4[portName=COM6,port=//./COM6] for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]
- 16:31:44.337 [TRACE] [o.b.m.internal.BaseModbusSlave:319 ] - ModbusSlave (slave4): returned connection for endpoint ModbusSerialSlaveEndpoint@601583b1[portName=COM6]