  1. !-Generator IDFEditor 1.48
  2. !-Option SortedOrder
  3.  
  4. !-NOTE: All comments with '!-' are ignored by the IDFEditor and are generated automatically.
  5. !- Use '!' comments if they need to be retained when using the IDFEditor.
  6.  
  7.  
  8. !- =========== ALL OBJECTS IN CLASS: VERSION ===========
  9.  
  10. Version,
  11. 8.5; !- Version Identifier
  12.  
  13.  
  14. !- =========== ALL OBJECTS IN CLASS: SIMULATIONCONTROL ===========
  15.  
  16. SimulationControl,
  17. Yes, !- Do Zone Sizing Calculation
  18. Yes, !- Do System Sizing Calculation
  19. Yes, !- Do Plant Sizing Calculation
  20. No, !- Run Simulation for Sizing Periods
  21. Yes; !- Run Simulation for Weather File Run Periods
  22.  
  23.  
  24. !- =========== ALL OBJECTS IN CLASS: BUILDING ===========
  25.  
  26. Building,
  27. Ref Bldg Small Office New2004_v1.3_5.0, !- Name
  28. 0, !- North Axis {deg}
  29. City, !- Terrain
  30. 0.04, !- Loads Convergence Tolerance Value
  31. 0.2, !- Temperature Convergence Tolerance Value {deltaC}
  32. FullInteriorAndExterior, !- Solar Distribution
  33. 25, !- Maximum Number of Warmup Days
  34. 6; !- Minimum Number of Warmup Days
  35.  
  36.  
  37. !- =========== ALL OBJECTS IN CLASS: SHADOWCALCULATION ===========
  38.  
  39. ShadowCalculation,
  40. AverageOverDaysInFrequency, !- Calculation Method
  41. 7, !- Calculation Frequency
  42. 15000; !- Maximum Figures in Shadow Overlap Calculations
  43.  
  44.  
  45. !- =========== ALL OBJECTS IN CLASS: SURFACECONVECTIONALGORITHM:INSIDE ===========
  46.  
  47. SurfaceConvectionAlgorithm:Inside,
  48. TARP; !- Algorithm
  49.  
  50.  
  51. !- =========== ALL OBJECTS IN CLASS: SURFACECONVECTIONALGORITHM:OUTSIDE ===========
  52.  
  53. SurfaceConvectionAlgorithm:Outside,
  54. DOE-2; !- Algorithm
  55.  
  56.  
  57. !- =========== ALL OBJECTS IN CLASS: HEATBALANCEALGORITHM ===========
  58.  
  59. HeatBalanceAlgorithm,
  60. ConductionTransferFunction, !- Algorithm
  61. 200; !- Surface Temperature Upper Limit {C}
  62.  
  63.  
  64. !- =========== ALL OBJECTS IN CLASS: ZONEAIRHEATBALANCEALGORITHM ===========
  65.  
  66. ZoneAirHeatBalanceAlgorithm,
  67. ThirdOrderBackwardDifference; !- Algorithm
  68.  
  69.  
  70. !- =========== ALL OBJECTS IN CLASS: ZONEAIRCONTAMINANTBALANCE ===========
  71.  
  72. ZoneAirContaminantBalance,
  73. No; !- Carbon Dioxide Concentration
  74.  
  75.  
  76. !- =========== ALL OBJECTS IN CLASS: TIMESTEP ===========
  77.  
  78. Timestep,
  79. 6; !- Number of Timesteps per Hour
  80.  
  81.  
  82. !- =========== ALL OBJECTS IN CLASS: CONVERGENCELIMITS ===========
  83.  
  84. ConvergenceLimits,
  85. 2, !- Minimum System Timestep {minutes}
  86. 25; !- Maximum HVAC Iterations
  87.  
  88.  
  89. !- =========== ALL OBJECTS IN CLASS: PROGRAMCONTROL ===========
  90.  
  91. ProgramControl,
  92. 1; !- Number of Threads Allowed
  93.  
  94.  
  95. !- =========== ALL OBJECTS IN CLASS: SITE:LOCATION ===========
  96.  
  97. Site:Location,
  98. Tampa International Ap, !- Name
  99. 27.97, !- Latitude {deg}
  100. -82.53, !- Longitude {deg}
  101. -5, !- Time Zone {hr}
  102. 6; !- Elevation {m}
  103.  
  104.  
  105. !- =========== ALL OBJECTS IN CLASS: SIZINGPERIOD:DESIGNDAY ===========
  106.  
  107. SizingPeriod:DesignDay,
  108. CHICAGO Ann Clg .4% Condns WB=>MDB, !- Name
  109. 7, !- Month
  110. 21, !- Day of Month
  111. SummerDesignDay, !- Day Type
  112. 31.2, !- Maximum Dry-Bulb Temperature {C}
  113. 10.7, !- Daily Dry-Bulb Temperature Range {deltaC}
  114. DefaultMultipliers, !- Dry-Bulb Temperature Range Modifier Type
  115. , !- Dry-Bulb Temperature Range Modifier Day Schedule Name
  116. Wetbulb, !- Humidity Condition Type
  117. 25.5, !- Wetbulb or DewPoint at Maximum Dry-Bulb {C}
  118. , !- Humidity Condition Day Schedule Name
  119. , !- Humidity Ratio at Maximum Dry-Bulb {kgWater/kgDryAir}
  120. , !- Enthalpy at Maximum Dry-Bulb {J/kg}
  121. , !- Daily Wet-Bulb Temperature Range {deltaC}
  122. 99063, !- Barometric Pressure {Pa}
  123. 5.3, !- Wind Speed {m/s}
  124. 230, !- Wind Direction {deg}
  125. No, !- Rain Indicator
  126. No, !- Snow Indicator
  127. No, !- Daylight Saving Time Indicator
  128. ASHRAEClearSky, !- Solar Model Indicator
  129. , !- Beam Solar Day Schedule Name
  130. , !- Diffuse Solar Day Schedule Name
  131. , !- ASHRAE Clear Sky Optical Depth for Beam Irradiance (taub) {dimensionless}
  132. , !- ASHRAE Clear Sky Optical Depth for Diffuse Irradiance (taud) {dimensionless}
  133. 1; !- Sky Clearness
  134.  
  135. SizingPeriod:DesignDay,
  136. CHICAGO Ann Htg 99.6% Condns DB, !- Name
  137. 1, !- Month
  138. 21, !- Day of Month
  139. WinterDesignDay, !- Day Type
  140. -20.6, !- Maximum Dry-Bulb Temperature {C}
  141. 0, !- Daily Dry-Bulb Temperature Range {deltaC}
  142. DefaultMultipliers, !- Dry-Bulb Temperature Range Modifier Type
  143. , !- Dry-Bulb Temperature Range Modifier Day Schedule Name
  144. Wetbulb, !- Humidity Condition Type
  145. -20.6, !- Wetbulb or DewPoint at Maximum Dry-Bulb {C}
  146. , !- Humidity Condition Day Schedule Name
  147. , !- Humidity Ratio at Maximum Dry-Bulb {kgWater/kgDryAir}
  148. , !- Enthalpy at Maximum Dry-Bulb {J/kg}
  149. , !- Daily Wet-Bulb Temperature Range {deltaC}
  150. 99063, !- Barometric Pressure {Pa}
  151. 4.9, !- Wind Speed {m/s}
  152. 270, !- Wind Direction {deg}
  153. No, !- Rain Indicator
  154. No, !- Snow Indicator
  155. No, !- Daylight Saving Time Indicator
  156. ASHRAEClearSky, !- Solar Model Indicator
  157. , !- Beam Solar Day Schedule Name
  158. , !- Diffuse Solar Day Schedule Name
  159. , !- ASHRAE Clear Sky Optical Depth for Beam Irradiance (taub) {dimensionless}
  160. , !- ASHRAE Clear Sky Optical Depth for Diffuse Irradiance (taud) {dimensionless}
  161. 0; !- Sky Clearness
  162.  
  163.  
  164. !- =========== ALL OBJECTS IN CLASS: RUNPERIOD ===========
  165.  
  166. RunPeriod,
  167. Run Period 1, !- Name
  168. 1, !- Begin Month
  169. 1, !- Begin Day of Month
  170. 12, !- End Month
  171. 31, !- End Day of Month
  172. Sunday, !- Day of Week for Start Day
  173. No, !- Use Weather File Holidays and Special Days
  174. No, !- Use Weather File Daylight Saving Period
  175. No, !- Apply Weekend Holiday Rule
  176. Yes, !- Use Weather File Rain Indicators
  177. Yes, !- Use Weather File Snow Indicators
  178. 1; !- Number of Times Runperiod to be Repeated
  179.  
  180.  
  181. !- =========== ALL OBJECTS IN CLASS: SCHEDULETYPELIMITS ===========
  182.  
  183. ScheduleTypeLimits,
  184. Fraction, !- Name
  185. 0, !- Lower Limit Value
  186. 1, !- Upper Limit Value
  187. CONTINUOUS; !- Numeric Type
  188.  
  189. ScheduleTypeLimits,
  190. Core_ZN Thermal Zone Thermostat Schedule Type Limits, !- Name
  191. 0, !- Lower Limit Value
  192. 4, !- Upper Limit Value
  193. DISCRETE; !- Numeric Type
  194.  
  195. ScheduleTypeLimits,
  196. Temperature, !- Name
  197. -60, !- Lower Limit Value
  198. 200, !- Upper Limit Value
  199. CONTINUOUS, !- Numeric Type
  200. temperature; !- Unit Type
  201.  
  202. ScheduleTypeLimits,
  203. Perimeter_ZN_1 Thermal Zone Thermostat Schedule Type Limits, !- Name
  204. 0, !- Lower Limit Value
  205. 4, !- Upper Limit Value
  206. DISCRETE; !- Numeric Type
  207.  
  208. ScheduleTypeLimits,
  209. Perimeter_ZN_2 Thermal Zone Thermostat Schedule Type Limits, !- Name
  210. 0, !- Lower Limit Value
  211. 4, !- Upper Limit Value
  212. DISCRETE; !- Numeric Type
  213.  
  214. ScheduleTypeLimits,
  215. Perimeter_ZN_3 Thermal Zone Thermostat Schedule Type Limits, !- Name
  216. 0, !- Lower Limit Value
  217. 4, !- Upper Limit Value
  218. DISCRETE; !- Numeric Type
  219.  
  220. ScheduleTypeLimits,
  221. Perimeter_ZN_4 Thermal Zone Thermostat Schedule Type Limits, !- Name
  222. 0, !- Lower Limit Value
  223. 4, !- Upper Limit Value
  224. DISCRETE; !- Numeric Type
  225.  
  226. ScheduleTypeLimits,
  227. ActivityLevel, !- Name
  228. 0, !- Lower Limit Value
  229. , !- Upper Limit Value
  230. Continuous, !- Numeric Type
  231. activitylevel; !- Unit Type
  232.  
  233. ScheduleTypeLimits,
  234. Any Number; !- Name
  235.  
  236. ScheduleTypeLimits,
  237. Control Type, !- Name
  238. 0, !- Lower Limit Value
  239. 4, !- Upper Limit Value
  240. DISCRETE, !- Numeric Type
  241. Control; !- Unit Type
  242.  
  243. ScheduleTypeLimits,
  244. Humidity, !- Name
  245. 10, !- Lower Limit Value
  246. 90, !- Upper Limit Value
  247. CONTINUOUS; !- Numeric Type
  248.  
  249. ScheduleTypeLimits,
  250. On/Off, !- Name
  251. 0, !- Lower Limit Value
  252. 1, !- Upper Limit Value
  253. DISCRETE, !- Numeric Type
  254. availability; !- Unit Type
  255.  
  256. ScheduleTypeLimits,
  257. OnOff, !- Name
  258. 0, !- Lower Limit Value
  259. 1, !- Upper Limit Value
  260. Discrete, !- Numeric Type
  261. availability; !- Unit Type
  262.  
  263. ScheduleTypeLimits,
  264. Schedule Type Limits 1, !- Name
  265. , !- Lower Limit Value
  266. , !- Upper Limit Value
  267. , !- Numeric Type
  268. dimensionless; !- Unit Type
  269.  
  270. ScheduleTypeLimits,
  271. Temperature 3, !- Name
  272. , !- Lower Limit Value
  273. , !- Upper Limit Value
  274. Continuous, !- Numeric Type
  275. temperature; !- Unit Type
  276.  
  277. ScheduleTypeLimits,
  278. Velocity, !- Name
  279. 0, !- Lower Limit Value
  280. , !- Upper Limit Value
  281. Continuous, !- Numeric Type
  282. velocity; !- Unit Type
  283.  
  284. ScheduleTypeLimits,
  285. {120e1ff4-5fa5-4ff0-836d-51022e48d7b5}; !- Name
  286.  
  287. ScheduleTypeLimits,
  288. {59ccb7fc-ca70-4ef0-b9dd-bb52267a4c04}; !- Name
  289.  
  290. ScheduleTypeLimits,
  291. {a5c2b8d9-14e8-4d66-99f3-792b0134795a}; !- Name
  292.  
  293. ScheduleTypeLimits,
  294. {e2523147-8b9e-451b-b144-6788a585e0f7}; !- Name
  295.  
  296. ScheduleTypeLimits,
  297. {f35baba5-7a0e-4466-bd24-858d4285dd8a}; !- Name
  298.  
  299.  
  300. !- =========== ALL OBJECTS IN CLASS: SCHEDULE:DAY:INTERVAL ===========
  301.  
  302. Schedule:Day:Interval,
  303. Chilled_Water_Temperature_Default, !- Name
  304. Temperature, !- Schedule Type Limits Name
  305. No, !- Interpolate to Timestep
  306. 24:00, !- Time 1 {hh:mm}
  307. 6.7; !- Value Until Time 1
  308.  
  309. Schedule:Day:Interval,
  310. Chilled_Water_Temperature_Summer_Design_Day, !- Name
  311. Temperature, !- Schedule Type Limits Name
  312. No, !- Interpolate to Timestep
  313. 24:00, !- Time 1 {hh:mm}
  314. 6.7; !- Value Until Time 1
  315.  
  316. Schedule:Day:Interval,
  317. Chilled_Water_Temperature_Winter_Design_Day, !- Name
  318. Temperature, !- Schedule Type Limits Name
  319. No, !- Interpolate to Timestep
  320. 24:00, !- Time 1 {hh:mm}
  321. 6.7; !- Value Until Time 1
  322.  
  323. Schedule:Day:Interval,
  324. Deck_Temperature_Default,!- Name
  325. Temperature, !- Schedule Type Limits Name
  326. No, !- Interpolate to Timestep
  327. 24:00, !- Time 1 {hh:mm}
  328. 12.8; !- Value Until Time 1
  329.  
  330. Schedule:Day:Interval,
  331. Deck_Temperature_Summer_Design_Day, !- Name
  332. Temperature, !- Schedule Type Limits Name
  333. No, !- Interpolate to Timestep
  334. 24:00, !- Time 1 {hh:mm}
  335. 12.8; !- Value Until Time 1
  336.  
  337. Schedule:Day:Interval,
  338. Deck_Temperature_Winter_Design_Day, !- Name
  339. Temperature, !- Schedule Type Limits Name
  340. No, !- Interpolate to Timestep
  341. 24:00, !- Time 1 {hh:mm}
  342. 12.8; !- Value Until Time 1
  343.  
  344. Schedule:Day:Interval,
  345. Hot_Water_Temperature_Default, !- Name
  346. Temperature, !- Schedule Type Limits Name
  347. No, !- Interpolate to Timestep
  348. 24:00, !- Time 1 {hh:mm}
  349. 67; !- Value Until Time 1
  350.  
  351. Schedule:Day:Interval,
  352. Hot_Water_Temperature_Summer_Design_Day, !- Name
  353. Temperature, !- Schedule Type Limits Name
  354. No, !- Interpolate to Timestep
  355. 24:00, !- Time 1 {hh:mm}
  356. 67; !- Value Until Time 1
  357.  
  358. Schedule:Day:Interval,
  359. Hot_Water_Temperature_Winter_Design_Day, !- Name
  360. Temperature, !- Schedule Type Limits Name
  361. No, !- Interpolate to Timestep
  362. 24:00, !- Time 1 {hh:mm}
  363. 67; !- Value Until Time 1
  364.  
  365. Schedule:Day:Interval,
  366. Schedule Day 1, !- Name
  367. Temperature 3, !- Schedule Type Limits Name
  368. No, !- Interpolate to Timestep
  369. 24:00, !- Time 1 {hh:mm}
  370. 48.89; !- Value Until Time 1
  371.  
  372.  
  373. !- =========== ALL OBJECTS IN CLASS: SCHEDULE:WEEK:DAILY ===========
  374.  
  375. Schedule:Week:Daily,
  376. Schedule:Week:Daily {83a18f16-0ea0-47cd-b321-7bdfcb8aec07}, !- Name
  377. Chilled_Water_Temperature_Default, !- Sunday Schedule:Day Name
  378. Chilled_Water_Temperature_Default, !- Monday Schedule:Day Name
  379. Chilled_Water_Temperature_Default, !- Tuesday Schedule:Day Name
  380. Chilled_Water_Temperature_Default, !- Wednesday Schedule:Day Name
  381. Chilled_Water_Temperature_Default, !- Thursday Schedule:Day Name
  382. Chilled_Water_Temperature_Default, !- Friday Schedule:Day Name
  383. Chilled_Water_Temperature_Default, !- Saturday Schedule:Day Name
  384. Chilled_Water_Temperature_Default, !- Holiday Schedule:Day Name
  385. Chilled_Water_Temperature_Summer_Design_Day, !- SummerDesignDay Schedule:Day Name
  386. Chilled_Water_Temperature_Winter_Design_Day, !- WinterDesignDay Schedule:Day Name
  387. Chilled_Water_Temperature_Default, !- CustomDay1 Schedule:Day Name
  388. Chilled_Water_Temperature_Default; !- CustomDay2 Schedule:Day Name
  389.  
  390. Schedule:Week:Daily,
  391. Schedule:Week:Daily {53d4d70b-173d-43e6-9a91-c41fd5cbe9be}, !- Name
  392. Deck_Temperature_Default,!- Sunday Schedule:Day Name
  393. Deck_Temperature_Default,!- Monday Schedule:Day Name
  394. Deck_Temperature_Default,!- Tuesday Schedule:Day Name
  395. Deck_Temperature_Default,!- Wednesday Schedule:Day Name
  396. Deck_Temperature_Default,!- Thursday Schedule:Day Name
  397. Deck_Temperature_Default,!- Friday Schedule:Day Name
  398. Deck_Temperature_Default,!- Saturday Schedule:Day Name
  399. Deck_Temperature_Default,!- Holiday Schedule:Day Name
  400. Deck_Temperature_Summer_Design_Day, !- SummerDesignDay Schedule:Day Name
  401. Deck_Temperature_Winter_Design_Day, !- WinterDesignDay Schedule:Day Name
  402. Deck_Temperature_Default,!- CustomDay1 Schedule:Day Name
  403. Deck_Temperature_Default;!- CustomDay2 Schedule:Day Name
  404.  
  405. Schedule:Week:Daily,
  406. Schedule:Week:Daily {b6d0f818-69c4-4a81-812c-f6c11766f9a7}, !- Name
  407. Hot_Water_Temperature_Default, !- Sunday Schedule:Day Name
  408. Hot_Water_Temperature_Default, !- Monday Schedule:Day Name
  409. Hot_Water_Temperature_Default, !- Tuesday Schedule:Day Name
  410. Hot_Water_Temperature_Default, !- Wednesday Schedule:Day Name
  411. Hot_Water_Temperature_Default, !- Thursday Schedule:Day Name
  412. Hot_Water_Temperature_Default, !- Friday Schedule:Day Name
  413. Hot_Water_Temperature_Default, !- Saturday Schedule:Day Name
  414. Hot_Water_Temperature_Default, !- Holiday Schedule:Day Name
  415. Hot_Water_Temperature_Summer_Design_Day, !- SummerDesignDay Schedule:Day Name
  416. Hot_Water_Temperature_Winter_Design_Day, !- WinterDesignDay Schedule:Day Name
  417. Hot_Water_Temperature_Default, !- CustomDay1 Schedule:Day Name
  418. Hot_Water_Temperature_Default; !- CustomDay2 Schedule:Day Name
  419.  
  420. Schedule:Week:Daily,
  421. Schedule:Week:Daily {97f89552-2d48-45d3-a20d-3b6e3fa06b5e}, !- Name
  422. Schedule Day 1, !- Sunday Schedule:Day Name
  423. Schedule Day 1, !- Monday Schedule:Day Name
  424. Schedule Day 1, !- Tuesday Schedule:Day Name
  425. Schedule Day 1, !- Wednesday Schedule:Day Name
  426. Schedule Day 1, !- Thursday Schedule:Day Name
  427. Schedule Day 1, !- Friday Schedule:Day Name
  428. Schedule Day 1, !- Saturday Schedule:Day Name
  429. Schedule Day 1, !- Holiday Schedule:Day Name
  430. Schedule Day 1, !- SummerDesignDay Schedule:Day Name
  431. Schedule Day 1, !- WinterDesignDay Schedule:Day Name
  432. Schedule Day 1, !- CustomDay1 Schedule:Day Name
  433. Schedule Day 1; !- CustomDay2 Schedule:Day Name
  434.  
  435.  
  436. !- =========== ALL OBJECTS IN CLASS: SCHEDULE:YEAR ===========
  437.  
  438. Schedule:Year,
  439. Chilled_Water_Temperature, !- Name
  440. Temperature, !- Schedule Type Limits Name
  441. Schedule:Week:Daily {83a18f16-0ea0-47cd-b321-7bdfcb8aec07}, !- Schedule:Week Name 1
  442. 1, !- Start Month 1
  443. 1, !- Start Day 1
  444. 12, !- End Month 1
  445. 31; !- End Day 1
  446.  
  447. Schedule:Year,
  448. Deck_Temperature, !- Name
  449. Temperature, !- Schedule Type Limits Name
  450. Schedule:Week:Daily {53d4d70b-173d-43e6-9a91-c41fd5cbe9be}, !- Schedule:Week Name 1
  451. 1, !- Start Month 1
  452. 1, !- Start Day 1
  453. 12, !- End Month 1
  454. 31; !- End Day 1
  455.  
  456. Schedule:Year,
  457. Hot_Water_Temperature, !- Name
  458. Temperature, !- Schedule Type Limits Name
  459. Schedule:Week:Daily {b6d0f818-69c4-4a81-812c-f6c11766f9a7}, !- Schedule:Week Name 1
  460. 1, !- Start Month 1
  461. 1, !- Start Day 1
  462. 12, !- End Month 1
  463. 31; !- End Day 1
  464.  
  465. Schedule:Year,
  466. Thermal Storage - Chilled Water Stratified Ambient Temp Schedule, !- Name
  467. Temperature 3, !- Schedule Type Limits Name
  468. Schedule:Week:Daily {97f89552-2d48-45d3-a20d-3b6e3fa06b5e}, !- Schedule:Week Name 1
  469. 1, !- Start Month 1
  470. 1, !- Start Day 1
  471. 12, !- End Month 1
  472. 31; !- End Day 1
  473.  
  474.  
  475. !- =========== ALL OBJECTS IN CLASS: SCHEDULE:COMPACT ===========
  476.  
  477. Schedule:Compact,
  478. BLDG_LIGHT_SCH, !- Name
  479. Fraction, !- Schedule Type Limits Name
  480. Through: 12/31, !- Field 1
  481. For: Weekdays, !- Field 2
  482. Until: 05:00, !- Field 3
  483. 0.05, !- Field 4
  484. Until: 07:00, !- Field 5
  485. 0.1, !- Field 6
  486. Until: 08:00, !- Field 7
  487. 0.3, !- Field 8
  488. Until: 17:00, !- Field 9
  489. 0.9, !- Field 10
  490. Until: 18:00, !- Field 11
  491. 0.5, !- Field 12
  492. Until: 20:00, !- Field 13
  493. 0.3, !- Field 14
  494. Until: 22:00, !- Field 15
  495. 0.2, !- Field 16
  496. Until: 23:00, !- Field 17
  497. 0.1, !- Field 18
  498. Until: 24:00, !- Field 19
  499. 0.05, !- Field 20
  500. For: Saturday, !- Field 21
  501. Until: 06:00, !- Field 22
  502. 0.05, !- Field 23
  503. Until: 08:00, !- Field 24
  504. 0.1, !- Field 25
  505. Until: 12:00, !- Field 26
  506. 0.3, !- Field 27
  507. Until: 17:00, !- Field 28
  508. 0.15, !- Field 29
  509. Until: 24:00, !- Field 30
  510. 0.05, !- Field 31
  511. For: SummerDesignDay, !- Field 32
  512. Until: 24:00, !- Field 33
  513. 1.0, !- Field 34
  514. For: WinterDesignDay, !- Field 35
  515. Until: 24:00, !- Field 36
  516. 0.0, !- Field 37
  517. For: AllOtherDays, !- Field 38
  518. Until: 24:00, !- Field 39
  519. 0.05; !- Field 40
  520.  
  521. Schedule:Compact,
  522. Core_ZN Thermal Zone Thermostat Schedule, !- Name
  523. Core_ZN Thermal Zone Thermostat Schedule Type Limits, !- Schedule Type Limits Name
  524. Through: 12/31, !- Field 1
  525. For: AllDays, !- Field 2
  526. Until: 24:00, !- Field 3
  527. 4; !- Field 4
  528.  
  529. Schedule:Compact,
  530. HTGSETP_SCH, !- Name
  531. Temperature, !- Schedule Type Limits Name
  532. Through: 12/31, !- Field 1
  533. For: Weekdays, !- Field 2
  534. Until: 06:00, !- Field 3
  535. 15.6, !- Field 4
  536. Until: 22:00, !- Field 5
  537. 21.0, !- Field 6
  538. Until: 24:00, !- Field 7
  539. 15.6, !- Field 8
  540. For: Saturday, !- Field 9
  541. Until: 06:00, !- Field 10
  542. 15.6, !- Field 11
  543. Until: 18:00, !- Field 12
  544. 21.0, !- Field 13
  545. Until: 24:00, !- Field 14
  546. 15.6, !- Field 15
  547. For: WinterDesignDay, !- Field 16
  548. Until: 24:00, !- Field 17
  549. 21.0, !- Field 18
  550. For: AllOtherDays, !- Field 19
  551. Until: 24:00, !- Field 20
  552. 15.6; !- Field 21
  553.  
  554. Schedule:Compact,
  555. CLGSETP_SCH, !- Name
  556. Temperature, !- Schedule Type Limits Name
  557. Through: 12/31, !- Field 1
  558. For: Weekdays SummerDesignDay, !- Field 2
  559. Until: 06:00, !- Field 3
  560. 26.7, !- Field 4
  561. Until: 22:00, !- Field 5
  562. 24.0, !- Field 6
  563. Until: 24:00, !- Field 7
  564. 26.7, !- Field 8
  565. For: Saturday, !- Field 9
  566. Until: 06:00, !- Field 10
  567. 26.7, !- Field 11
  568. Until: 18:00, !- Field 12
  569. 24.0, !- Field 13
  570. Until: 24:00, !- Field 14
  571. 26.7, !- Field 15
  572. For: AllOtherDays, !- Field 16
  573. Until: 24:00, !- Field 17
  574. 26.7; !- Field 18
  575.  
  576. Schedule:Compact,
  577. Perimeter_ZN_1 Thermal Zone Thermostat Schedule, !- Name
  578. Perimeter_ZN_1 Thermal Zone Thermostat Schedule Type Limits, !- Schedule Type Limits Name
  579. Through: 12/31, !- Field 1
  580. For: AllDays, !- Field 2
  581. Until: 24:00, !- Field 3
  582. 4; !- Field 4
  583.  
  584. Schedule:Compact,
  585. Perimeter_ZN_2 Thermal Zone Thermostat Schedule, !- Name
  586. Perimeter_ZN_2 Thermal Zone Thermostat Schedule Type Limits, !- Schedule Type Limits Name
  587. Through: 12/31, !- Field 1
  588. For: AllDays, !- Field 2
  589. Until: 24:00, !- Field 3
  590. 4; !- Field 4
  591.  
  592. Schedule:Compact,
  593. Perimeter_ZN_3 Thermal Zone Thermostat Schedule, !- Name
  594. Perimeter_ZN_3 Thermal Zone Thermostat Schedule Type Limits, !- Schedule Type Limits Name
  595. Through: 12/31, !- Field 1
  596. For: AllDays, !- Field 2
  597. Until: 24:00, !- Field 3
  598. 4; !- Field 4
  599.  
  600. Schedule:Compact,
  601. Perimeter_ZN_4 Thermal Zone Thermostat Schedule, !- Name
  602. Perimeter_ZN_4 Thermal Zone Thermostat Schedule Type Limits, !- Schedule Type Limits Name
  603. Through: 12/31, !- Field 1
  604. For: AllDays, !- Field 2
  605. Until: 24:00, !- Field 3
  606. 4; !- Field 4
  607.  
  608. Schedule:Compact,
  609. ACTIVITY_SCH, !- Name
  610. ActivityLevel, !- Schedule Type Limits Name
  611. Through: 12/31, !- Field 1
  612. For: AllDays, !- Field 2
  613. Until: 24:00, !- Field 3
  614. 120; !- Field 4
  615.  
  616. Schedule:Compact,
  617. AIR_VELO_SCH, !- Name
  618. Velocity, !- Schedule Type Limits Name
  619. Through: 12/31, !- Field 1
  620. For: AllDays, !- Field 2
  621. Until: 24:00, !- Field 3
  622. 0.2; !- Field 4
  623.  
  624. Schedule:Compact,
  625. ALWAYS_ON, !- Name
  626. On/Off, !- Schedule Type Limits Name
  627. Through: 12/31, !- Field 1
  628. For: AllDays, !- Field 2
  629. Until: 24:00, !- Field 3
  630. 1; !- Field 4
  631.  
  632. Schedule:Compact,
  633. BLDG_EQUIP_SCH, !- Name
  634. Fraction, !- Schedule Type Limits Name
  635. Through: 12/31, !- Field 1
  636. For: Weekdays, !- Field 2
  637. Until: 08:00, !- Field 3
  638. 0.40, !- Field 4
  639. Until: 12:00, !- Field 5
  640. 0.90, !- Field 6
  641. Until: 13:00, !- Field 7
  642. 0.80, !- Field 8
  643. Until: 17:00, !- Field 9
  644. 0.90, !- Field 10
  645. Until: 18:00, !- Field 11
  646. 0.50, !- Field 12
  647. Until: 24:00, !- Field 13
  648. 0.40, !- Field 14
  649. For: Saturday, !- Field 15
  650. Until: 06:00, !- Field 16
  651. 0.30, !- Field 17
  652. Until: 08:00, !- Field 18
  653. 0.4, !- Field 19
  654. Until: 12:00, !- Field 20
  655. 0.5, !- Field 21
  656. Until: 17:00, !- Field 22
  657. 0.35, !- Field 23
  658. Until: 24:00, !- Field 24
  659. 0.30, !- Field 25
  660. For: SummerDesignDay, !- Field 26
  661. Until: 24:00, !- Field 27
  662. 1.0, !- Field 28
  663. For: WinterDesignDay, !- Field 29
  664. Until: 24:00, !- Field 30
  665. 0.0, !- Field 31
  666. For: AllOtherDays, !- Field 32
  667. Until: 24:00, !- Field 33
  668. 0.30; !- Field 34
  669.  
  670. Schedule:Compact,
  671. BLDG_OCC_SCH, !- Name
  672. Fraction, !- Schedule Type Limits Name
  673. Through: 12/31, !- Field 1
  674. For: SummerDesignDay, !- Field 2
  675. Until: 06:00, !- Field 3
  676. 0.0, !- Field 4
  677. Until: 22:00, !- Field 5
  678. 1.0, !- Field 6
  679. Until: 24:00, !- Field 7
  680. 0.05, !- Field 8
  681. For: Weekdays, !- Field 9
  682. Until: 06:00, !- Field 10
  683. 0.0, !- Field 11
  684. Until: 07:00, !- Field 12
  685. 0.1, !- Field 13
  686. Until: 08:00, !- Field 14
  687. 0.2, !- Field 15
  688. Until: 12:00, !- Field 16
  689. 0.95, !- Field 17
  690. Until: 13:00, !- Field 18
  691. 0.5, !- Field 19
  692. Until: 17:00, !- Field 20
  693. 0.95, !- Field 21
  694. Until: 18:00, !- Field 22
  695. 0.3, !- Field 23
  696. Until: 20:00, !- Field 24
  697. 0.1, !- Field 25
  698. Until: 24:00, !- Field 26
  699. 0.05, !- Field 27
  700. For: Saturday, !- Field 28
  701. Until: 06:00, !- Field 29
  702. 0.0, !- Field 30
  703. Until: 08:00, !- Field 31
  704. 0.1, !- Field 32
  705. Until: 12:00, !- Field 33
  706. 0.3, !- Field 34
  707. Until: 17:00, !- Field 35
  708. 0.1, !- Field 36
  709. Until: 24:00, !- Field 37
  710. 0.0, !- Field 38
  711. For: AllOtherDays, !- Field 39
  712. Until: 24:00, !- Field 40
  713. 0.0; !- Field 41
  714.  
  715. Schedule:Compact,
  716. BLDG_SWH_SCH, !- Name
  717. Fraction, !- Schedule Type Limits Name
  718. Through: 12/31, !- Field 1
  719. For: Weekdays SummerDesignDay, !- Field 2
  720. Until: 05:00, !- Field 3
  721. 0.05, !- Field 4
  722. Until: 06:00, !- Field 5
  723. 0.08, !- Field 6
  724. Until: 07:00, !- Field 7
  725. 0.07, !- Field 8
  726. Until: 08:00, !- Field 9
  727. 0.19, !- Field 10
  728. Until: 09:00, !- Field 11
  729. 0.35, !- Field 12
  730. Until: 10:00, !- Field 13
  731. 0.38, !- Field 14
  732. Until: 11:00, !- Field 15
  733. 0.39, !- Field 16
  734. Until: 12:00, !- Field 17
  735. 0.47, !- Field 18
  736. Until: 13:00, !- Field 19
  737. 0.57, !- Field 20
  738. Until: 14:00, !- Field 21
  739. 0.54, !- Field 22
  740. Until: 15:00, !- Field 23
  741. 0.34, !- Field 24
  742. Until: 16:00, !- Field 25
  743. 0.33, !- Field 26
  744. Until: 17:00, !- Field 27
  745. 0.44, !- Field 28
  746. Until: 18:00, !- Field 29
  747. 0.26, !- Field 30
  748. Until: 19:00, !- Field 31
  749. 0.21, !- Field 32
  750. Until: 20:00, !- Field 33
  751. 0.15, !- Field 34
  752. Until: 21:00, !- Field 35
  753. 0.17, !- Field 36
  754. Until: 22:00, !- Field 37
  755. 0.08, !- Field 38
  756. Until: 24:00, !- Field 39
  757. 0.05, !- Field 40
  758. For: Saturday WinterDesignDay, !- Field 41
  759. Until: 05:00, !- Field 42
  760. 0.05, !- Field 43
  761. Until: 06:00, !- Field 44
  762. 0.08, !- Field 45
  763. Until: 07:00, !- Field 46
  764. 0.07, !- Field 47
  765. Until: 08:00, !- Field 48
  766. 0.11, !- Field 49
  767. Until: 09:00, !- Field 50
  768. 0.15, !- Field 51
  769. Until: 10:00, !- Field 52
  770. 0.21, !- Field 53
  771. Until: 11:00, !- Field 54
  772. 0.19, !- Field 55
  773. Until: 12:00, !- Field 56
  774. 0.23, !- Field 57
  775. Until: 13:00, !- Field 58
  776. 0.20, !- Field 59
  777. Until: 14:00, !- Field 60
  778. 0.19, !- Field 61
  779. Until: 15:00, !- Field 62
  780. 0.15, !- Field 63
  781. Until: 16:00, !- Field 64
  782. 0.13, !- Field 65
  783. Until: 17:00, !- Field 66
  784. 0.14, !- Field 67
  785. Until: 21:00, !- Field 68
  786. 0.07, !- Field 69
  787. Until: 22:00, !- Field 70
  788. 0.09, !- Field 71
  789. Until: 24:00, !- Field 72
  790. 0.05, !- Field 73
  791. For: AllOtherDays, !- Field 74
  792. Until: 05:00, !- Field 75
  793. 0.04, !- Field 76
  794. Until: 06:00, !- Field 77
  795. 0.07, !- Field 78
  796. Until: 11:00, !- Field 79
  797. 0.04, !- Field 80
  798. Until: 13:00, !- Field 81
  799. 0.06, !- Field 82
  800. Until: 14:00, !- Field 83
  801. 0.09, !- Field 84
  802. Until: 15:00, !- Field 85
  803. 0.06, !- Field 86
  804. Until: 21:00, !- Field 87
  805. 0.04, !- Field 88
  806. Until: 22:00, !- Field 89
  807. 0.07, !- Field 90
  808. Until: 24:00, !- Field 91
  809. 0.04; !- Field 92
  810.  
  811. Schedule:Compact,
  812. CLOTHING_SCH, !- Name
  813. Any Number, !- Schedule Type Limits Name
  814. Through: 04/30, !- Field 1
  815. For: AllDays, !- Field 2
  816. Until: 24:00, !- Field 3
  817. 1.0, !- Field 4
  818. Through: 09/30, !- Field 5
  819. For: AllDays, !- Field 6
  820. Until: 24:00, !- Field 7
  821. 0.5, !- Field 8
  822. Through: 12/31, !- Field 9
  823. For: AllDays, !- Field 10
  824. Until: 24:00, !- Field 11
  825. 1.0; !- Field 12
  826.  
  827. Schedule:Compact,
  828. CW-Tank-Temp-Schedule, !- Name
  829. Temperature, !- Schedule Type Limits Name
  830. Through: 12/31, !- Field 1
  831. For: AllDays, !- Field 2
  832. Until: 24:00, !- Field 3
  833. 7.5; !- Field 4
  834.  
  835. Schedule:Compact,
  836. Dual Zone Control Type Sched, !- Name
  837. Control Type, !- Schedule Type Limits Name
  838. Through: 12/31, !- Field 1
  839. For: AllDays, !- Field 2
  840. Until: 24:00, !- Field 3
  841. 4; !- Field 4
  842.  
  843. Schedule:Compact,
  844. HVACOperationSchd, !- Name
  845. On/Off, !- Schedule Type Limits Name
  846. Through: 12/31, !- Field 1
  847. For: Weekdays SummerDesignDay, !- Field 2
  848. Until: 06:00, !- Field 3
  849. 0.0, !- Field 4
  850. Until: 22:00, !- Field 5
  851. 1.0, !- Field 6
  852. Until: 24:00, !- Field 7
  853. 0.0, !- Field 8
  854. For: Saturday WinterDesignDay, !- Field 9
  855. Until: 06:00, !- Field 10
  856. 0.0, !- Field 11
  857. Until: 18:00, !- Field 12
  858. 1.0, !- Field 13
  859. Until: 24:00, !- Field 14
  860. 0.0, !- Field 15
  861. For: AllOtherDays, !- Field 16
  862. Until: 24:00, !- Field 17
  863. 0.0; !- Field 18
  864.  
  865. Schedule:Compact,
  866. INFIL_QUARTER_ON_SCH, !- Name
  867. Fraction, !- Schedule Type Limits Name
  868. Through: 12/31, !- Field 1
  869. For: Weekdays SummerDesignDay, !- Field 2
  870. Until: 06:00, !- Field 3
  871. 1.0, !- Field 4
  872. Until: 22:00, !- Field 5
  873. 0.25, !- Field 6
  874. Until: 24:00, !- Field 7
  875. 1.0, !- Field 8
  876. For: Saturday WinterDesignDay, !- Field 9
  877. Until: 06:00, !- Field 10
  878. 1.0, !- Field 11
  879. Until: 18:00, !- Field 12
  880. 0.25, !- Field 13
  881. Until: 24:00, !- Field 14
  882. 1.0, !- Field 15
  883. For: Sunday Holidays AllOtherDays, !- Field 16
  884. Until: 24:00, !- Field 17
  885. 1.0; !- Field 18
  886.  
  887. Schedule:Compact,
  888. MinOA_Sched, !- Name
  889. Fraction, !- Schedule Type Limits Name
  890. Through: 12/31, !- Field 1
  891. For: Weekdays SummerDesignDay, !- Field 2
  892. Until: 07:00, !- Field 3
  893. 0.0, !- Field 4
  894. Until: 22:00, !- Field 5
  895. 1.0, !- Field 6
  896. Until: 24:00, !- Field 7
  897. 0.0, !- Field 8
  898. For: Saturday WinterDesignDay, !- Field 9
  899. Until: 07:00, !- Field 10
  900. 0.0, !- Field 11
  901. Until: 18:00, !- Field 12
  902. 1.0, !- Field 13
  903. Until: 24:00, !- Field 14
  904. 0.0, !- Field 15
  905. For: AllOtherDays, !- Field 16
  906. Until: 24:00, !- Field 17
  907. 0.0; !- Field 18
  908.  
  909. Schedule:Compact,
  910. OFF PEAK, !- Name
  911. Fraction, !- Schedule Type Limits Name
  912. Through: 12/31, !- Field 1
  913. For: Alldays, !- Field 2
  914. Until: 9:00, !- Field 3
  915. 1.00, !- Field 4
  916. Until: 18:00, !- Field 5
  917. 0.00, !- Field 6
  918. Until: 24:00, !- Field 7
  919. 1.00; !- Field 8
  920.  
  921. Schedule:Compact,
  922. ON PEAK, !- Name
  923. Fraction, !- Schedule Type Limits Name
  924. Through: 12/31, !- Field 1
  925. For: Alldays, !- Field 2
  926. Until: 9:00, !- Field 3
  927. 0.00, !- Field 4
  928. Until: 18:00, !- Field 5
  929. 1.00, !- Field 6
  930. Until: 24:00, !- Field 7
  931. 0.00; !- Field 8
  932.  
  933. Schedule:Compact,
  934. SWHSys1 Water Heater Ambient Temperature Schedule Name, !- Name
  935. Temperature, !- Schedule Type Limits Name
  936. Through: 12/31, !- Field 1
  937. For: AllDays, !- Field 2
  938. Until: 24:00, !- Field 3
  939. 22.0; !- Field 4
  940.  
  941. Schedule:Compact,
  942. SWHSys1 Water Heater Setpoint Temperature Schedule Name, !- Name
  943. Temperature, !- Schedule Type Limits Name
  944. Through: 12/31, !- Field 1
  945. For: AllDays, !- Field 2
  946. Until: 24:00, !- Field 3
  947. 60.0; !- Field 4
  948.  
  949. Schedule:Compact,
  950. SWHSys1-Loop-Temp-Schedule, !- Name
  951. Temperature, !- Schedule Type Limits Name
  952. Through: 12/31, !- Field 1
  953. For: AllDays, !- Field 2
  954. Until: 24:00, !- Field 3
  955. 60.0; !- Field 4
  956.  
  957. Schedule:Compact,
  958. TES Charge Schedule, !- Name
  959. On/Off, !- Schedule Type Limits Name
  960. Through: 12/31, !- Field 1
  961. For: Weekdays SummerDesignDay, !- Field 2
  962. Until: 10:00, !- Field 3
  963. 1.0, !- Field 4
  964. Until: 17:00, !- Field 5
  965. 0.0, !- Field 6
  966. Until: 24:00, !- Field 7
  967. 1.0, !- Field 8
  968. For: Saturday WinterDesignDay, !- Field 9
  969. Until: 12:00, !- Field 10
  970. 1.0, !- Field 11
  971. Until: 18:00, !- Field 12
  972. 0.0, !- Field 13
  973. Until: 24:00, !- Field 14
  974. 1.0, !- Field 15
  975. For: Sunday Holidays AllOtherDays, !- Field 16
  976. Until: 24:00, !- Field 17
  977. 1.0; !- Field 18
  978.  
  979. Schedule:Compact,
  980. Water Equipment Hot Supply Temp Sched, !- Name
  981. Temperature, !- Schedule Type Limits Name
  982. Through: 12/31, !- Field 1
  983. For: AllDays, !- Field 2
  984. Until: 24:00, !- Field 3
  985. 43.3; !- Field 4
  986.  
  987. Schedule:Compact,
  988. Water Equipment Latent fract sched, !- Name
  989. Fraction, !- Schedule Type Limits Name
  990. Through: 12/31, !- Field 1
  991. For: AllDays, !- Field 2
  992. Until: 24:00, !- Field 3
  993. 0.05; !- Field 4
  994.  
  995. Schedule:Compact,
  996. Water Equipment Sensible fract sched, !- Name
  997. Fraction, !- Schedule Type Limits Name
  998. Through: 12/31, !- Field 1
  999. For: AllDays, !- Field 2
  1000. Until: 24:00, !- Field 3
  1001. 0.2; !- Field 4
  1002.  
  1003. Schedule:Compact,
  1004. Water Equipment Temp Sched, !- Name
  1005. Temperature, !- Schedule Type Limits Name
  1006. Through: 12/31, !- Field 1
  1007. For: AllDays, !- Field 2
  1008. Until: 24:00, !- Field 3
  1009. 43.3; !- Field 4
  1010.  
  1011. Schedule:Compact,
  1012. WORK_EFF_SCH, !- Name
  1013. Fraction, !- Schedule Type Limits Name
  1014. Through: 12/31, !- Field 1
  1015. For: AllDays, !- Field 2
  1016. Until: 24:00, !- Field 3
  1017. 0.0; !- Field 4
  1018.  
  1019. Schedule:Compact,
  1020. FanAvailSched, !- Name
  1021. Fraction, !- Schedule Type Limits Name
  1022. Through: 12/31, !- Field 1
  1023. For: WeekDays CustomDay1 CustomDay2, !- Field 2
  1024. Until: 6:00, !- Field 3
  1025. 0.0, !- Field 4
  1026. Until: 21:00, !- Field 5
  1027. 1.0, !- Field 6
  1028. Until: 24:00, !- Field 7
  1029. 0.0, !- Field 8
  1030. For: Weekends Holiday, !- Field 9
  1031. Until: 24:00, !- Field 10
  1032. 0.0, !- Field 11
  1033. For: SummerDesignDay, !- Field 12
  1034. Until: 24:00, !- Field 13
  1035. 1.0, !- Field 14
  1036. For: WinterDesignDay, !- Field 15
  1037. Until: 24:00, !- Field 16
  1038. 1.0; !- Field 17
  1039.  
  1040. Schedule:Compact,
  1041. CW-Primary-Loop-Temp-Schedule, !- Name
  1042. Temperature, !- Schedule Type Limits Name
  1043. Through:12/31, !- Field 1
  1044. ForL AllDays, !- Field 2
  1045. Until:24:00, !- Field 3
  1046. 6.7; !- Field 4
  1047.  
  1048. Schedule:Compact,
  1049. Sec-CW-Primary-Loop-Temp-Schedule, !- Name
  1050. Temperature, !- Schedule Type Limits Name
  1051. Through:12/31, !- Field 1
  1052. ForL AllDays, !- Field 2
  1053. Until:24:00, !- Field 3
  1054. 8.5; !- Field 4
  1055.  
  1056.  
  1057. !- =========== ALL OBJECTS IN CLASS: SCHEDULE:CONSTANT ===========
  1058.  
  1059. Schedule:Constant,
  1060. Always On Discrete, !- Name
  1061. OnOff, !- Schedule Type Limits Name
  1062. 1; !- Hourly Value
  1063.  
  1064. Schedule:Constant,
  1065. Always Off Discrete, !- Name
  1066. On/Off, !- Schedule Type Limits Name
  1067. 0; !- Hourly Value
  1068.  
  1069. Schedule:Constant,
  1070. Always On Continuous, !- Name
  1071. OnOff, !- Schedule Type Limits Name
  1072. 1; !- Hourly Value
  1073.  
  1074.  
  1075. !- =========== ALL OBJECTS IN CLASS: MATERIAL ===========
  1076.  
  1077. Material,
  1078. 1/2IN Gypsum, !- Name
  1079. Smooth, !- Roughness
  1080. 0.0127, !- Thickness {m}
  1081. 0.16, !- Conductivity {W/m-K}
  1082. 784.9, !- Density {kg/m3}
  1083. 830, !- Specific Heat {J/kg-K}
  1084. 0.9, !- Thermal Absorptance
  1085. 0.92, !- Solar Absorptance
  1086. 0.92; !- Visible Absorptance
  1087.  
  1088. Material,
  1089. 1IN Stucco, !- Name
  1090. Smooth, !- Roughness
  1091. 0.0253, !- Thickness {m}
  1092. 0.6918, !- Conductivity {W/m-K}
  1093. 1858, !- Density {kg/m3}
  1094. 837, !- Specific Heat {J/kg-K}
  1095. 0.9, !- Thermal Absorptance
  1096. 0.92, !- Solar Absorptance
  1097. 0.92; !- Visible Absorptance
  1098.  
  1099. Material,
  1100. 8IN CONCRETE HW, !- Name
  1101. Rough, !- Roughness
  1102. 0.2032, !- Thickness {m}
  1103. 1.311, !- Conductivity {W/m-K}
  1104. 2240, !- Density {kg/m3}
  1105. 836.8, !- Specific Heat {J/kg-K}
  1106. 0.9, !- Thermal Absorptance
  1107. 0.7, !- Solar Absorptance
  1108. 0.7; !- Visible Absorptance
  1109.  
  1110. Material,
  1111. AtticFloor NonRes Insulation, !- Name
  1112. MediumRough, !- Roughness
  1113. 0.236804989096202, !- Thickness {m}
  1114. 0.049, !- Conductivity {W/m-K}
  1115. 265, !- Density {kg/m3}
  1116. 836.8, !- Specific Heat {J/kg-K}
  1117. 0.9, !- Thermal Absorptance
  1118. 0.7, !- Solar Absorptance
  1119. 0.7; !- Visible Absorptance
  1120.  
  1121. Material,
  1122. HW CONCRETE, !- Name
  1123. Rough, !- Roughness
  1124. 0.1016, !- Thickness {m}
  1125. 1.311, !- Conductivity {W/m-K}
  1126. 2240, !- Density {kg/m3}
  1127. 836.8, !- Specific Heat {J/kg-K}
  1128. 0.9, !- Thermal Absorptance
  1129. 0.7, !- Solar Absorptance
  1130. 0.7; !- Visible Absorptance
  1131.  
  1132. Material,
  1133. Mass NonRes Wall Insulation, !- Name
  1134. MediumRough, !- Roughness
  1135. 0.0495494599433393, !- Thickness {m}
  1136. 0.049, !- Conductivity {W/m-K}
  1137. 265, !- Density {kg/m3}
  1138. 836.8, !- Specific Heat {J/kg-K}
  1139. 0.9, !- Thermal Absorptance
  1140. 0.7, !- Solar Absorptance
  1141. 0.7; !- Visible Absorptance
  1142.  
  1143. Material,
  1144. MAT-CC05 4 HW CONCRETE, !- Name
  1145. Rough, !- Roughness
  1146. 0.1016, !- Thickness {m}
  1147. 1.311, !- Conductivity {W/m-K}
  1148. 2240, !- Density {kg/m3}
  1149. 836.8, !- Specific Heat {J/kg-K}
  1150. 0.9, !- Thermal Absorptance
  1151. 0.7, !- Solar Absorptance
  1152. 0.7; !- Visible Absorptance
  1153.  
  1154. Material,
  1155. Metal Decking, !- Name
  1156. MediumSmooth, !- Roughness
  1157. 0.0015, !- Thickness {m}
  1158. 45.006, !- Conductivity {W/m-K}
  1159. 7680, !- Density {kg/m3}
  1160. 418.4, !- Specific Heat {J/kg-K}
  1161. 0.9, !- Thermal Absorptance
  1162. 0.7, !- Solar Absorptance
  1163. 0.3; !- Visible Absorptance
  1164.  
  1165. Material,
  1166. Metal Roofing, !- Name
  1167. MediumSmooth, !- Roughness
  1168. 0.0015, !- Thickness {m}
  1169. 45.006, !- Conductivity {W/m-K}
  1170. 7680, !- Density {kg/m3}
  1171. 418.4, !- Specific Heat {J/kg-K}
  1172. 0.9, !- Thermal Absorptance
  1173. 0.7, !- Solar Absorptance
  1174. 0.3; !- Visible Absorptance
  1175.  
  1176. Material,
  1177. Metal Siding, !- Name
  1178. Smooth, !- Roughness
  1179. 0.0015, !- Thickness {m}
  1180. 44.96, !- Conductivity {W/m-K}
  1181. 7688.86, !- Density {kg/m3}
  1182. 410, !- Specific Heat {J/kg-K}
  1183. 0.9, !- Thermal Absorptance
  1184. 0.2, !- Solar Absorptance
  1185. 0.2; !- Visible Absorptance
  1186.  
  1187. Material,
  1188. Roof Membrane, !- Name
  1189. VeryRough, !- Roughness
  1190. 0.0095, !- Thickness {m}
  1191. 0.16, !- Conductivity {W/m-K}
  1192. 1121.29, !- Density {kg/m3}
  1193. 1460, !- Specific Heat {J/kg-K}
  1194. 0.9, !- Thermal Absorptance
  1195. 0.7, !- Solar Absorptance
  1196. 0.7; !- Visible Absorptance
  1197.  
  1198. Material,
  1199. Std AC02, !- Name
  1200. MediumSmooth, !- Roughness
  1201. 0.0127, !- Thickness {m}
  1202. 0.057, !- Conductivity {W/m-K}
  1203. 288, !- Density {kg/m3}
  1204. 1339, !- Specific Heat {J/kg-K}
  1205. 0.9, !- Thermal Absorptance
  1206. 0.7, !- Solar Absorptance
  1207. 0.2; !- Visible Absorptance
  1208.  
  1209. Material,
  1210. Std Wood 6inch, !- Name
  1211. MediumSmooth, !- Roughness
  1212. 0.15, !- Thickness {m}
  1213. 0.12, !- Conductivity {W/m-K}
  1214. 540, !- Density {kg/m3}
  1215. 1210, !- Specific Heat {J/kg-K}
  1216. 0.9, !- Thermal Absorptance
  1217. 0.7, !- Solar Absorptance
  1218. 0.7; !- Visible Absorptance
  1219.  
  1220. Material,
  1221. Wood Siding, !- Name
  1222. MediumSmooth, !- Roughness
  1223. 0.01, !- Thickness {m}
  1224. 0.11, !- Conductivity {W/m-K}
  1225. 544.62, !- Density {kg/m3}
  1226. 1210, !- Specific Heat {J/kg-K}
  1227. 0.9, !- Thermal Absorptance
  1228. 0.78, !- Solar Absorptance
  1229. 0.78; !- Visible Absorptance
  1230.  
  1231.  
  1232. !- =========== ALL OBJECTS IN CLASS: MATERIAL:NOMASS ===========
  1233.  
  1234. Material:NoMass,
  1235. CP02 CARPET PAD, !- Name
  1236. VeryRough, !- Roughness
  1237. 0.2165, !- Thermal Resistance {m2-K/W}
  1238. 0.9, !- Thermal Absorptance
  1239. 0.7, !- Solar Absorptance
  1240. 0.8; !- Visible Absorptance
  1241.  
  1242. Material:NoMass,
  1243. MAT-AIR-WALL, !- Name
  1244. Rough, !- Roughness
  1245. 0.2079491, !- Thermal Resistance {m2-K/W}
  1246. 0.9, !- Thermal Absorptance
  1247. 0.7, !- Solar Absorptance
  1248. 0.7; !- Visible Absorptance
  1249.  
  1250.  
  1251. !- =========== ALL OBJECTS IN CLASS: WINDOWMATERIAL:SIMPLEGLAZINGSYSTEM ===========
  1252.  
  1253. WindowMaterial:SimpleGlazingSystem,
  1254. NonRes Fixed Assembly Window, !- Name
  1255. 3.23646, !- U-Factor {W/m2-K}
  1256. 0.39; !- Solar Heat Gain Coefficient
  1257.  
  1258.  
  1259. !- =========== ALL OBJECTS IN CLASS: CONSTRUCTION ===========
  1260.  
  1261. Construction,
  1262. AIR-WALL, !- Name
  1263. MAT-AIR-WALL; !- Outside Layer
  1264.  
  1265. Construction,
  1266. Attic Non-res Floor, !- Name
  1267. 1/2IN Gypsum, !- Outside Layer
  1268. AtticFloor NonRes Insulation, !- Layer 2
  1269. 1/2IN Gypsum; !- Layer 3
  1270.  
  1271. Construction,
  1272. Attic Non-res Roof, !- Name
  1273. Roof Membrane, !- Outside Layer
  1274. Metal Decking; !- Layer 2
  1275.  
  1276. Construction,
  1277. DropCeiling, !- Name
  1278. Std AC02; !- Outside Layer
  1279.  
  1280. Construction,
  1281. ext-slab, !- Name
  1282. HW CONCRETE, !- Outside Layer
  1283. CP02 CARPET PAD; !- Layer 2
  1284.  
  1285. Construction,
  1286. int-walls, !- Name
  1287. 1/2IN Gypsum, !- Outside Layer
  1288. 1/2IN Gypsum; !- Layer 2
  1289.  
  1290. Construction,
  1291. InteriorFurnishings, !- Name
  1292. Std Wood 6inch; !- Outside Layer
  1293.  
  1294. Construction,
  1295. Mass Non-res Ext Wall, !- Name
  1296. 1IN Stucco, !- Outside Layer
  1297. 8IN CONCRETE HW, !- Layer 2
  1298. Mass NonRes Wall Insulation, !- Layer 3
  1299. 1/2IN Gypsum; !- Layer 4
  1300.  
  1301. Construction,
  1302. Window Non-res Fixed, !- Name
  1303. NonRes Fixed Assembly Window; !- Outside Layer
  1304.  
  1305.  
  1306. !- =========== ALL OBJECTS IN CLASS: GLOBALGEOMETRYRULES ===========
  1307.  
  1308. GlobalGeometryRules,
  1309. UpperLeftCorner, !- Starting Vertex Position
  1310. Counterclockwise, !- Vertex Entry Direction
  1311. Relative, !- Coordinate System
  1312. Relative, !- Daylighting Reference Point Coordinate System
  1313. Relative; !- Rectangular Surface Coordinate System
  1314.  
  1315.  
  1316. !- =========== ALL OBJECTS IN CLASS: ZONE ===========
  1317.  
  1318. Zone,
  1319. Attic Thermal Zone, !- Name
  1320. 0, !- Direction of Relative North {deg}
  1321. 0, !- X Origin {m}
  1322. 0, !- Y Origin {m}
  1323. 0, !- Z Origin {m}
  1324. , !- Type
  1325. 1, !- Multiplier
  1326. , !- Ceiling Height {m}
  1327. , !- Volume {m3}
  1328. , !- Floor Area {m2}
  1329. , !- Zone Inside Convection Algorithm
  1330. , !- Zone Outside Convection Algorithm
  1331. No; !- Part of Total Floor Area
  1332.  
  1333. Zone,
  1334. Core_ZN Thermal Zone, !- Name
  1335. 0, !- Direction of Relative North {deg}
  1336. 0, !- X Origin {m}
  1337. 0, !- Y Origin {m}
  1338. 0, !- Z Origin {m}
  1339. , !- Type
  1340. 1, !- Multiplier
  1341. , !- Ceiling Height {m}
  1342. , !- Volume {m3}
  1343. , !- Floor Area {m2}
  1344. , !- Zone Inside Convection Algorithm
  1345. , !- Zone Outside Convection Algorithm
  1346. Yes; !- Part of Total Floor Area
  1347.  
  1348. Zone,
  1349. Perimeter_ZN_1 Thermal Zone, !- Name
  1350. 0, !- Direction of Relative North {deg}
  1351. 0, !- X Origin {m}
  1352. 0, !- Y Origin {m}
  1353. 0, !- Z Origin {m}
  1354. , !- Type
  1355. 1, !- Multiplier
  1356. , !- Ceiling Height {m}
  1357. , !- Volume {m3}
  1358. , !- Floor Area {m2}
  1359. , !- Zone Inside Convection Algorithm
  1360. , !- Zone Outside Convection Algorithm
  1361. Yes; !- Part of Total Floor Area
  1362.  
  1363. Zone,
  1364. Perimeter_ZN_2 Thermal Zone, !- Name
  1365. 0, !- Direction of Relative North {deg}
  1366. 0, !- X Origin {m}
  1367. 0, !- Y Origin {m}
  1368. 0, !- Z Origin {m}
  1369. , !- Type
  1370. 1, !- Multiplier
  1371. , !- Ceiling Height {m}
  1372. , !- Volume {m3}
  1373. , !- Floor Area {m2}
  1374. , !- Zone Inside Convection Algorithm
  1375. , !- Zone Outside Convection Algorithm
  1376. Yes; !- Part of Total Floor Area
  1377.  
  1378. Zone,
  1379. Perimeter_ZN_3 Thermal Zone, !- Name
  1380. 0, !- Direction of Relative North {deg}
  1381. 0, !- X Origin {m}
  1382. 0, !- Y Origin {m}
  1383. 0, !- Z Origin {m}
  1384. , !- Type
  1385. 1, !- Multiplier
  1386. , !- Ceiling Height {m}
  1387. , !- Volume {m3}
  1388. , !- Floor Area {m2}
  1389. , !- Zone Inside Convection Algorithm
  1390. , !- Zone Outside Convection Algorithm
  1391. Yes; !- Part of Total Floor Area
  1392.  
  1393. Zone,
  1394. Perimeter_ZN_4 Thermal Zone, !- Name
  1395. 0, !- Direction of Relative North {deg}
  1396. 0, !- X Origin {m}
  1397. 0, !- Y Origin {m}
  1398. 0, !- Z Origin {m}
  1399. , !- Type
  1400. 1, !- Multiplier
  1401. , !- Ceiling Height {m}
  1402. , !- Volume {m3}
  1403. , !- Floor Area {m2}
  1404. , !- Zone Inside Convection Algorithm
  1405. , !- Zone Outside Convection Algorithm
  1406. Yes; !- Part of Total Floor Area
  1407.  
  1408.  
  1409. !- =========== ALL OBJECTS IN CLASS: BUILDINGSURFACE:DETAILED ===========
  1410.  
  1411. BuildingSurface:Detailed,
  1412. Attic_floor_core, !- Name
  1413. Floor, !- Surface Type
  1414. Attic Non-res Floor, !- Construction Name
  1415. Attic Thermal Zone, !- Zone Name
  1416. Surface, !- Outside Boundary Condition
  1417. Core_ZN_ceiling, !- Outside Boundary Condition Object
  1418. NoSun, !- Sun Exposure
  1419. NoWind, !- Wind Exposure
  1420. , !- View Factor to Ground
  1421. , !- Number of Vertices
  1422. 22.69, !- Vertex 1 X-coordinate {m}
  1423. 13.46, !- Vertex 1 Y-coordinate {m}
  1424. 3.05, !- Vertex 1 Z-coordinate {m}
  1425. 22.69, !- Vertex 2 X-coordinate {m}
  1426. 5, !- Vertex 2 Y-coordinate {m}
  1427. 3.05, !- Vertex 2 Z-coordinate {m}
  1428. 5, !- Vertex 3 X-coordinate {m}
  1429. 5, !- Vertex 3 Y-coordinate {m}
  1430. 3.05, !- Vertex 3 Z-coordinate {m}
  1431. 5, !- Vertex 4 X-coordinate {m}
  1432. 13.46, !- Vertex 4 Y-coordinate {m}
  1433. 3.05; !- Vertex 4 Z-coordinate {m}
  1434.  
  1435. BuildingSurface:Detailed,
  1436. Attic_floor_perimeter_east, !- Name
  1437. Floor, !- Surface Type
  1438. Attic Non-res Floor, !- Construction Name
  1439. Attic Thermal Zone, !- Zone Name
  1440. Surface, !- Outside Boundary Condition
  1441. Perimeter_ZN_2_ceiling, !- Outside Boundary Condition Object
  1442. NoSun, !- Sun Exposure
  1443. NoWind, !- Wind Exposure
  1444. , !- View Factor to Ground
  1445. , !- Number of Vertices
  1446. 27.69, !- Vertex 1 X-coordinate {m}
  1447. 18.46, !- Vertex 1 Y-coordinate {m}
  1448. 3.05, !- Vertex 1 Z-coordinate {m}
  1449. 27.69, !- Vertex 2 X-coordinate {m}
  1450. 0, !- Vertex 2 Y-coordinate {m}
  1451. 3.05, !- Vertex 2 Z-coordinate {m}
  1452. 22.69, !- Vertex 3 X-coordinate {m}
  1453. 5, !- Vertex 3 Y-coordinate {m}
  1454. 3.05, !- Vertex 3 Z-coordinate {m}
  1455. 22.69, !- Vertex 4 X-coordinate {m}
  1456. 13.46, !- Vertex 4 Y-coordinate {m}
  1457. 3.05; !- Vertex 4 Z-coordinate {m}
  1458.  
  1459. BuildingSurface:Detailed,
  1460. Attic_floor_perimeter_north, !- Name
  1461. Floor, !- Surface Type
  1462. Attic Non-res Floor, !- Construction Name
  1463. Attic Thermal Zone, !- Zone Name
  1464. Surface, !- Outside Boundary Condition
  1465. Perimeter_ZN_3_ceiling, !- Outside Boundary Condition Object
  1466. NoSun, !- Sun Exposure
  1467. NoWind, !- Wind Exposure
  1468. , !- View Factor to Ground
  1469. , !- Number of Vertices
  1470. 27.69, !- Vertex 1 X-coordinate {m}
  1471. 18.46, !- Vertex 1 Y-coordinate {m}
  1472. 3.05, !- Vertex 1 Z-coordinate {m}
  1473. 22.69, !- Vertex 2 X-coordinate {m}
  1474. 13.46, !- Vertex 2 Y-coordinate {m}
  1475. 3.05, !- Vertex 2 Z-coordinate {m}
  1476. 5, !- Vertex 3 X-coordinate {m}
  1477. 13.46, !- Vertex 3 Y-coordinate {m}
  1478. 3.05, !- Vertex 3 Z-coordinate {m}
  1479. 0, !- Vertex 4 X-coordinate {m}
  1480. 18.46, !- Vertex 4 Y-coordinate {m}
  1481. 3.05; !- Vertex 4 Z-coordinate {m}
  1482.  
  1483. BuildingSurface:Detailed,
  1484. Attic_floor_perimeter_south, !- Name
  1485. Floor, !- Surface Type
  1486. Attic Non-res Floor, !- Construction Name
  1487. Attic Thermal Zone, !- Zone Name
  1488. Surface, !- Outside Boundary Condition
  1489. Perimeter_ZN_1_ceiling, !- Outside Boundary Condition Object
  1490. NoSun, !- Sun Exposure
  1491. NoWind, !- Wind Exposure
  1492. , !- View Factor to Ground
  1493. , !- Number of Vertices
  1494. 22.69, !- Vertex 1 X-coordinate {m}
  1495. 5, !- Vertex 1 Y-coordinate {m}
  1496. 3.05, !- Vertex 1 Z-coordinate {m}
  1497. 27.69, !- Vertex 2 X-coordinate {m}
  1498. 0, !- Vertex 2 Y-coordinate {m}
  1499. 3.05, !- Vertex 2 Z-coordinate {m}
  1500. 0, !- Vertex 3 X-coordinate {m}
  1501. 0, !- Vertex 3 Y-coordinate {m}
  1502. 3.05, !- Vertex 3 Z-coordinate {m}
  1503. 5, !- Vertex 4 X-coordinate {m}
  1504. 5, !- Vertex 4 Y-coordinate {m}
  1505. 3.05; !- Vertex 4 Z-coordinate {m}
  1506.  
  1507. BuildingSurface:Detailed,
  1508. Attic_floor_perimeter_west, !- Name
  1509. Floor, !- Surface Type
  1510. Attic Non-res Floor, !- Construction Name
  1511. Attic Thermal Zone, !- Zone Name
  1512. Surface, !- Outside Boundary Condition
  1513. Perimeter_ZN_4_ceiling, !- Outside Boundary Condition Object
  1514. NoSun, !- Sun Exposure
  1515. NoWind, !- Wind Exposure
  1516. , !- View Factor to Ground
  1517. , !- Number of Vertices
  1518. 0, !- Vertex 1 X-coordinate {m}
  1519. 18.46, !- Vertex 1 Y-coordinate {m}
  1520. 3.05, !- Vertex 1 Z-coordinate {m}
  1521. 5, !- Vertex 2 X-coordinate {m}
  1522. 13.46, !- Vertex 2 Y-coordinate {m}
  1523. 3.05, !- Vertex 2 Z-coordinate {m}
  1524. 5, !- Vertex 3 X-coordinate {m}
  1525. 5, !- Vertex 3 Y-coordinate {m}
  1526. 3.05, !- Vertex 3 Z-coordinate {m}
  1527. 0, !- Vertex 4 X-coordinate {m}
  1528. 0, !- Vertex 4 Y-coordinate {m}
  1529. 3.05; !- Vertex 4 Z-coordinate {m}
  1530.  
  1531. BuildingSurface:Detailed,
  1532. Attic_roof_east, !- Name
  1533. Roof, !- Surface Type
  1534. Attic Non-res Roof, !- Construction Name
  1535. Attic Thermal Zone, !- Zone Name
  1536. Outdoors, !- Outside Boundary Condition
  1537. , !- Outside Boundary Condition Object
  1538. SunExposed, !- Sun Exposure
  1539. WindExposed, !- Wind Exposure
  1540. , !- View Factor to Ground
  1541. , !- Number of Vertices
  1542. 18.46, !- Vertex 1 X-coordinate {m}
  1543. 9.23, !- Vertex 1 Y-coordinate {m}
  1544. 6.33, !- Vertex 1 Z-coordinate {m}
  1545. 28.29, !- Vertex 2 X-coordinate {m}
  1546. -0.6, !- Vertex 2 Y-coordinate {m}
  1547. 3.05, !- Vertex 2 Z-coordinate {m}
  1548. 28.29, !- Vertex 3 X-coordinate {m}
  1549. 19.06, !- Vertex 3 Y-coordinate {m}
  1550. 3.05; !- Vertex 3 Z-coordinate {m}
  1551.  
  1552. BuildingSurface:Detailed,
  1553. Attic_roof_north, !- Name
  1554. Roof, !- Surface Type
  1555. Attic Non-res Roof, !- Construction Name
  1556. Attic Thermal Zone, !- Zone Name
  1557. Outdoors, !- Outside Boundary Condition
  1558. , !- Outside Boundary Condition Object
  1559. SunExposed, !- Sun Exposure
  1560. WindExposed, !- Wind Exposure
  1561. , !- View Factor to Ground
  1562. , !- Number of Vertices
  1563. 18.46, !- Vertex 1 X-coordinate {m}
  1564. 9.23, !- Vertex 1 Y-coordinate {m}
  1565. 6.33, !- Vertex 1 Z-coordinate {m}
  1566. 28.29, !- Vertex 2 X-coordinate {m}
  1567. 19.06, !- Vertex 2 Y-coordinate {m}
  1568. 3.05, !- Vertex 2 Z-coordinate {m}
  1569. -0.6, !- Vertex 3 X-coordinate {m}
  1570. 19.06, !- Vertex 3 Y-coordinate {m}
  1571. 3.05, !- Vertex 3 Z-coordinate {m}
  1572. 9.23, !- Vertex 4 X-coordinate {m}
  1573. 9.23, !- Vertex 4 Y-coordinate {m}
  1574. 6.33; !- Vertex 4 Z-coordinate {m}
  1575.  
  1576. BuildingSurface:Detailed,
  1577. Attic_roof_south, !- Name
  1578. Roof, !- Surface Type
  1579. Attic Non-res Roof, !- Construction Name
  1580. Attic Thermal Zone, !- Zone Name
  1581. Outdoors, !- Outside Boundary Condition
  1582. , !- Outside Boundary Condition Object
  1583. SunExposed, !- Sun Exposure
  1584. WindExposed, !- Wind Exposure
  1585. , !- View Factor to Ground
  1586. , !- Number of Vertices
  1587. 9.23, !- Vertex 1 X-coordinate {m}
  1588. 9.23, !- Vertex 1 Y-coordinate {m}
  1589. 6.33, !- Vertex 1 Z-coordinate {m}
  1590. -0.6, !- Vertex 2 X-coordinate {m}
  1591. -0.6, !- Vertex 2 Y-coordinate {m}
  1592. 3.05, !- Vertex 2 Z-coordinate {m}
  1593. 28.29, !- Vertex 3 X-coordinate {m}
  1594. -0.6, !- Vertex 3 Y-coordinate {m}
  1595. 3.05, !- Vertex 3 Z-coordinate {m}
  1596. 18.46, !- Vertex 4 X-coordinate {m}
  1597. 9.23, !- Vertex 4 Y-coordinate {m}
  1598. 6.33; !- Vertex 4 Z-coordinate {m}
  1599.  
  1600. BuildingSurface:Detailed,
  1601. Attic_roof_west, !- Name
  1602. Roof, !- Surface Type
  1603. Attic Non-res Roof, !- Construction Name
  1604. Attic Thermal Zone, !- Zone Name
  1605. Outdoors, !- Outside Boundary Condition
  1606. , !- Outside Boundary Condition Object
  1607. SunExposed, !- Sun Exposure
  1608. WindExposed, !- Wind Exposure
  1609. , !- View Factor to Ground
  1610. , !- Number of Vertices
  1611. 9.23, !- Vertex 1 X-coordinate {m}
  1612. 9.23, !- Vertex 1 Y-coordinate {m}
  1613. 6.33, !- Vertex 1 Z-coordinate {m}
  1614. -0.6, !- Vertex 2 X-coordinate {m}
  1615. 19.06, !- Vertex 2 Y-coordinate {m}
  1616. 3.05, !- Vertex 2 Z-coordinate {m}
  1617. -0.6, !- Vertex 3 X-coordinate {m}
  1618. -0.6, !- Vertex 3 Y-coordinate {m}
  1619. 3.05; !- Vertex 3 Z-coordinate {m}
  1620.  
  1621. BuildingSurface:Detailed,
  1622. Attic_soffit_east, !- Name
  1623. Floor, !- Surface Type
  1624. Attic Non-res Floor, !- Construction Name
  1625. Attic Thermal Zone, !- Zone Name
  1626. Outdoors, !- Outside Boundary Condition
  1627. , !- Outside Boundary Condition Object
  1628. SunExposed, !- Sun Exposure
  1629. WindExposed, !- Wind Exposure
  1630. , !- View Factor to Ground
  1631. , !- Number of Vertices
  1632. 28.29, !- Vertex 1 X-coordinate {m}
  1633. 19.06, !- Vertex 1 Y-coordinate {m}
  1634. 3.05, !- Vertex 1 Z-coordinate {m}
  1635. 28.29, !- Vertex 2 X-coordinate {m}
  1636. -0.6, !- Vertex 2 Y-coordinate {m}
  1637. 3.05, !- Vertex 2 Z-coordinate {m}
  1638. 27.69, !- Vertex 3 X-coordinate {m}
  1639. 0, !- Vertex 3 Y-coordinate {m}
  1640. 3.05, !- Vertex 3 Z-coordinate {m}
  1641. 27.69, !- Vertex 4 X-coordinate {m}
  1642. 18.46, !- Vertex 4 Y-coordinate {m}
  1643. 3.05; !- Vertex 4 Z-coordinate {m}
  1644.  
  1645. BuildingSurface:Detailed,
  1646. Attic_soffit_north, !- Name
  1647. Floor, !- Surface Type
  1648. Attic Non-res Floor, !- Construction Name
  1649. Attic Thermal Zone, !- Zone Name
  1650. Outdoors, !- Outside Boundary Condition
  1651. , !- Outside Boundary Condition Object
  1652. SunExposed, !- Sun Exposure
  1653. WindExposed, !- Wind Exposure
  1654. , !- View Factor to Ground
  1655. , !- Number of Vertices
  1656. 28.29, !- Vertex 1 X-coordinate {m}
  1657. 19.06, !- Vertex 1 Y-coordinate {m}
  1658. 3.05, !- Vertex 1 Z-coordinate {m}
  1659. 27.69, !- Vertex 2 X-coordinate {m}
  1660. 18.46, !- Vertex 2 Y-coordinate {m}
  1661. 3.05, !- Vertex 2 Z-coordinate {m}
  1662. 0, !- Vertex 3 X-coordinate {m}
  1663. 18.46, !- Vertex 3 Y-coordinate {m}
  1664. 3.05, !- Vertex 3 Z-coordinate {m}
  1665. -0.6, !- Vertex 4 X-coordinate {m}
  1666. 19.06, !- Vertex 4 Y-coordinate {m}
  1667. 3.05; !- Vertex 4 Z-coordinate {m}
  1668.  
  1669. BuildingSurface:Detailed,
  1670. Attic_soffit_south, !- Name
  1671. Floor, !- Surface Type
  1672. Attic Non-res Floor, !- Construction Name
  1673. Attic Thermal Zone, !- Zone Name
  1674. Outdoors, !- Outside Boundary Condition
  1675. , !- Outside Boundary Condition Object
  1676. SunExposed, !- Sun Exposure
  1677. WindExposed, !- Wind Exposure
  1678. , !- View Factor to Ground
  1679. , !- Number of Vertices
  1680. 27.69, !- Vertex 1 X-coordinate {m}
  1681. 0, !- Vertex 1 Y-coordinate {m}
  1682. 3.05, !- Vertex 1 Z-coordinate {m}
  1683. 28.29, !- Vertex 2 X-coordinate {m}
  1684. -0.6, !- Vertex 2 Y-coordinate {m}
  1685. 3.05, !- Vertex 2 Z-coordinate {m}
  1686. -0.6, !- Vertex 3 X-coordinate {m}
  1687. -0.6, !- Vertex 3 Y-coordinate {m}
  1688. 3.05, !- Vertex 3 Z-coordinate {m}
  1689. 0, !- Vertex 4 X-coordinate {m}
  1690. 0, !- Vertex 4 Y-coordinate {m}
  1691. 3.05; !- Vertex 4 Z-coordinate {m}
  1692.  
  1693. BuildingSurface:Detailed,
  1694. Attic_soffit_west, !- Name
  1695. Floor, !- Surface Type
  1696. Attic Non-res Floor, !- Construction Name
  1697. Attic Thermal Zone, !- Zone Name
  1698. Outdoors, !- Outside Boundary Condition
  1699. , !- Outside Boundary Condition Object
  1700. SunExposed, !- Sun Exposure
  1701. WindExposed, !- Wind Exposure
  1702. , !- View Factor to Ground
  1703. , !- Number of Vertices
  1704. -0.6, !- Vertex 1 X-coordinate {m}
  1705. 19.06, !- Vertex 1 Y-coordinate {m}
  1706. 3.05, !- Vertex 1 Z-coordinate {m}
  1707. 0, !- Vertex 2 X-coordinate {m}
  1708. 18.46, !- Vertex 2 Y-coordinate {m}
  1709. 3.05, !- Vertex 2 Z-coordinate {m}
  1710. 0, !- Vertex 3 X-coordinate {m}
  1711. 0, !- Vertex 3 Y-coordinate {m}
  1712. 3.05, !- Vertex 3 Z-coordinate {m}
  1713. -0.6, !- Vertex 4 X-coordinate {m}
  1714. -0.6, !- Vertex 4 Y-coordinate {m}
  1715. 3.05; !- Vertex 4 Z-coordinate {m}
  1716.  
  1717. BuildingSurface:Detailed,
  1718. Core_ZN_ceiling, !- Name
  1719. Ceiling, !- Surface Type
  1720. Attic Non-res Floor, !- Construction Name
  1721. Core_ZN Thermal Zone, !- Zone Name
  1722. Surface, !- Outside Boundary Condition
  1723. Attic_floor_core, !- Outside Boundary Condition Object
  1724. NoSun, !- Sun Exposure
  1725. NoWind, !- Wind Exposure
  1726. , !- View Factor to Ground
  1727. , !- Number of Vertices
  1728. 22.69, !- Vertex 1 X-coordinate {m}
  1729. 5, !- Vertex 1 Y-coordinate {m}
  1730. 3.05, !- Vertex 1 Z-coordinate {m}
  1731. 22.69, !- Vertex 2 X-coordinate {m}
  1732. 13.46, !- Vertex 2 Y-coordinate {m}
  1733. 3.05, !- Vertex 2 Z-coordinate {m}
  1734. 5, !- Vertex 3 X-coordinate {m}
  1735. 13.46, !- Vertex 3 Y-coordinate {m}
  1736. 3.05, !- Vertex 3 Z-coordinate {m}
  1737. 5, !- Vertex 4 X-coordinate {m}
  1738. 5, !- Vertex 4 Y-coordinate {m}
  1739. 3.05; !- Vertex 4 Z-coordinate {m}
  1740.  
  1741. BuildingSurface:Detailed,
  1742. Core_ZN_floor, !- Name
  1743. Floor, !- Surface Type
  1744. ext-slab, !- Construction Name
  1745. Core_ZN Thermal Zone, !- Zone Name
  1746. Ground, !- Outside Boundary Condition
  1747. , !- Outside Boundary Condition Object
  1748. NoSun, !- Sun Exposure
  1749. NoWind, !- Wind Exposure
  1750. autocalculate, !- View Factor to Ground
  1751. , !- Number of Vertices
  1752. 22.69, !- Vertex 1 X-coordinate {m}
  1753. 13.46, !- Vertex 1 Y-coordinate {m}
  1754. 0, !- Vertex 1 Z-coordinate {m}
  1755. 22.69, !- Vertex 2 X-coordinate {m}
  1756. 5, !- Vertex 2 Y-coordinate {m}
  1757. 0, !- Vertex 2 Z-coordinate {m}
  1758. 5, !- Vertex 3 X-coordinate {m}
  1759. 5, !- Vertex 3 Y-coordinate {m}
  1760. 0, !- Vertex 3 Z-coordinate {m}
  1761. 5, !- Vertex 4 X-coordinate {m}
  1762. 13.46, !- Vertex 4 Y-coordinate {m}
  1763. 0; !- Vertex 4 Z-coordinate {m}
  1764.  
  1765. BuildingSurface:Detailed,
  1766. Core_ZN_wall_east, !- Name
  1767. Wall, !- Surface Type
  1768. int-walls, !- Construction Name
  1769. Core_ZN Thermal Zone, !- Zone Name
  1770. Surface, !- Outside Boundary Condition
  1771. Perimeter_ZN_2_wall_west,!- Outside Boundary Condition Object
  1772. NoSun, !- Sun Exposure
  1773. NoWind, !- Wind Exposure
  1774. , !- View Factor to Ground
  1775. , !- Number of Vertices
  1776. 22.69, !- Vertex 1 X-coordinate {m}
  1777. 5, !- Vertex 1 Y-coordinate {m}
  1778. 3.05, !- Vertex 1 Z-coordinate {m}
  1779. 22.69, !- Vertex 2 X-coordinate {m}
  1780. 5, !- Vertex 2 Y-coordinate {m}
  1781. 0, !- Vertex 2 Z-coordinate {m}
  1782. 22.69, !- Vertex 3 X-coordinate {m}
  1783. 13.46, !- Vertex 3 Y-coordinate {m}
  1784. 0, !- Vertex 3 Z-coordinate {m}
  1785. 22.69, !- Vertex 4 X-coordinate {m}
  1786. 13.46, !- Vertex 4 Y-coordinate {m}
  1787. 3.05; !- Vertex 4 Z-coordinate {m}
  1788.  
  1789. BuildingSurface:Detailed,
  1790. Core_ZN_wall_north, !- Name
  1791. Wall, !- Surface Type
  1792. int-walls, !- Construction Name
  1793. Core_ZN Thermal Zone, !- Zone Name
  1794. Surface, !- Outside Boundary Condition
  1795. Perimeter_ZN_3_wall_south, !- Outside Boundary Condition Object
  1796. NoSun, !- Sun Exposure
  1797. NoWind, !- Wind Exposure
  1798. , !- View Factor to Ground
  1799. , !- Number of Vertices
  1800. 22.69, !- Vertex 1 X-coordinate {m}
  1801. 13.46, !- Vertex 1 Y-coordinate {m}
  1802. 3.05, !- Vertex 1 Z-coordinate {m}
  1803. 22.69, !- Vertex 2 X-coordinate {m}
  1804. 13.46, !- Vertex 2 Y-coordinate {m}
  1805. 0, !- Vertex 2 Z-coordinate {m}
  1806. 5, !- Vertex 3 X-coordinate {m}
  1807. 13.46, !- Vertex 3 Y-coordinate {m}
  1808. 0, !- Vertex 3 Z-coordinate {m}
  1809. 5, !- Vertex 4 X-coordinate {m}
  1810. 13.46, !- Vertex 4 Y-coordinate {m}
  1811. 3.05; !- Vertex 4 Z-coordinate {m}
  1812.  
  1813. BuildingSurface:Detailed,
  1814. Core_ZN_wall_south, !- Name
  1815. Wall, !- Surface Type
  1816. int-walls, !- Construction Name
  1817. Core_ZN Thermal Zone, !- Zone Name
  1818. Surface, !- Outside Boundary Condition
  1819. Perimeter_ZN_1_wall_north, !- Outside Boundary Condition Object
  1820. NoSun, !- Sun Exposure
  1821. NoWind, !- Wind Exposure
  1822. , !- View Factor to Ground
  1823. , !- Number of Vertices
  1824. 5, !- Vertex 1 X-coordinate {m}
  1825. 5, !- Vertex 1 Y-coordinate {m}
  1826. 3.05, !- Vertex 1 Z-coordinate {m}
  1827. 5, !- Vertex 2 X-coordinate {m}
  1828. 5, !- Vertex 2 Y-coordinate {m}
  1829. 0, !- Vertex 2 Z-coordinate {m}
  1830. 22.69, !- Vertex 3 X-coordinate {m}
  1831. 5, !- Vertex 3 Y-coordinate {m}
  1832. 0, !- Vertex 3 Z-coordinate {m}
  1833. 22.69, !- Vertex 4 X-coordinate {m}
  1834. 5, !- Vertex 4 Y-coordinate {m}
  1835. 3.05; !- Vertex 4 Z-coordinate {m}
  1836.  
  1837. BuildingSurface:Detailed,
  1838. Core_ZN_wall_west, !- Name
  1839. Wall, !- Surface Type
  1840. int-walls, !- Construction Name
  1841. Core_ZN Thermal Zone, !- Zone Name
  1842. Surface, !- Outside Boundary Condition
  1843. Perimeter_ZN_4_wall_east,!- Outside Boundary Condition Object
  1844. NoSun, !- Sun Exposure
  1845. NoWind, !- Wind Exposure
  1846. , !- View Factor to Ground
  1847. , !- Number of Vertices
  1848. 5, !- Vertex 1 X-coordinate {m}
  1849. 13.46, !- Vertex 1 Y-coordinate {m}
  1850. 3.05, !- Vertex 1 Z-coordinate {m}
  1851. 5, !- Vertex 2 X-coordinate {m}
  1852. 13.46, !- Vertex 2 Y-coordinate {m}
  1853. 0, !- Vertex 2 Z-coordinate {m}
  1854. 5, !- Vertex 3 X-coordinate {m}
  1855. 5, !- Vertex 3 Y-coordinate {m}
  1856. 0, !- Vertex 3 Z-coordinate {m}
  1857. 5, !- Vertex 4 X-coordinate {m}
  1858. 5, !- Vertex 4 Y-coordinate {m}
  1859. 3.05; !- Vertex 4 Z-coordinate {m}
  1860.  
  1861. BuildingSurface:Detailed,
  1862. Perimeter_ZN_1_ceiling, !- Name
  1863. Ceiling, !- Surface Type
  1864. Attic Non-res Floor, !- Construction Name
  1865. Perimeter_ZN_1 Thermal Zone, !- Zone Name
  1866. Surface, !- Outside Boundary Condition
  1867. Attic_floor_perimeter_south, !- Outside Boundary Condition Object
  1868. NoSun, !- Sun Exposure
  1869. NoWind, !- Wind Exposure
  1870. , !- View Factor to Ground
  1871. , !- Number of Vertices
  1872. 27.69, !- Vertex 1 X-coordinate {m}
  1873. 0, !- Vertex 1 Y-coordinate {m}
  1874. 3.05, !- Vertex 1 Z-coordinate {m}
  1875. 22.69, !- Vertex 2 X-coordinate {m}
  1876. 5, !- Vertex 2 Y-coordinate {m}
  1877. 3.05, !- Vertex 2 Z-coordinate {m}
  1878. 5, !- Vertex 3 X-coordinate {m}
  1879. 5, !- Vertex 3 Y-coordinate {m}
  1880. 3.05, !- Vertex 3 Z-coordinate {m}
  1881. 0, !- Vertex 4 X-coordinate {m}
  1882. 0, !- Vertex 4 Y-coordinate {m}
  1883. 3.05; !- Vertex 4 Z-coordinate {m}
  1884.  
  1885. BuildingSurface:Detailed,
  1886. Perimeter_ZN_1_floor, !- Name
  1887. Floor, !- Surface Type
  1888. ext-slab, !- Construction Name
  1889. Perimeter_ZN_1 Thermal Zone, !- Zone Name
  1890. Ground, !- Outside Boundary Condition
  1891. , !- Outside Boundary Condition Object
  1892. NoSun, !- Sun Exposure
  1893. NoWind, !- Wind Exposure
  1894. autocalculate, !- View Factor to Ground
  1895. , !- Number of Vertices
  1896. 22.69, !- Vertex 1 X-coordinate {m}
  1897. 5, !- Vertex 1 Y-coordinate {m}
  1898. 0, !- Vertex 1 Z-coordinate {m}
  1899. 27.69, !- Vertex 2 X-coordinate {m}
  1900. 0, !- Vertex 2 Y-coordinate {m}
  1901. 0, !- Vertex 2 Z-coordinate {m}
  1902. 0, !- Vertex 3 X-coordinate {m}
  1903. 0, !- Vertex 3 Y-coordinate {m}
  1904. 0, !- Vertex 3 Z-coordinate {m}
  1905. 5, !- Vertex 4 X-coordinate {m}
  1906. 5, !- Vertex 4 Y-coordinate {m}
  1907. 0; !- Vertex 4 Z-coordinate {m}
  1908.  
  1909. BuildingSurface:Detailed,
  1910. Perimeter_ZN_1_wall_east,!- Name
  1911. Wall, !- Surface Type
  1912. int-walls, !- Construction Name
  1913. Perimeter_ZN_1 Thermal Zone, !- Zone Name
  1914. Surface, !- Outside Boundary Condition
  1915. Perimeter_ZN_2_wall_south, !- Outside Boundary Condition Object
  1916. NoSun, !- Sun Exposure
  1917. NoWind, !- Wind Exposure
  1918. , !- View Factor to Ground
  1919. , !- Number of Vertices
  1920. 27.69, !- Vertex 1 X-coordinate {m}
  1921. 2.04187384066908e-015, !- Vertex 1 Y-coordinate {m}
  1922. 3.05, !- Vertex 1 Z-coordinate {m}
  1923. 27.69, !- Vertex 2 X-coordinate {m}
  1924. 2.04187384066908e-015, !- Vertex 2 Y-coordinate {m}
  1925. 0, !- Vertex 2 Z-coordinate {m}
  1926. 22.69, !- Vertex 3 X-coordinate {m}
  1927. 5, !- Vertex 3 Y-coordinate {m}
  1928. 0, !- Vertex 3 Z-coordinate {m}
  1929. 22.69, !- Vertex 4 X-coordinate {m}
  1930. 5, !- Vertex 4 Y-coordinate {m}
  1931. 3.05; !- Vertex 4 Z-coordinate {m}
  1932.  
  1933. BuildingSurface:Detailed,
  1934. Perimeter_ZN_1_wall_north, !- Name
  1935. Wall, !- Surface Type
  1936. int-walls, !- Construction Name
  1937. Perimeter_ZN_1 Thermal Zone, !- Zone Name
  1938. Surface, !- Outside Boundary Condition
  1939. Core_ZN_wall_south, !- Outside Boundary Condition Object
  1940. NoSun, !- Sun Exposure
  1941. NoWind, !- Wind Exposure
  1942. , !- View Factor to Ground
  1943. , !- Number of Vertices
  1944. 22.69, !- Vertex 1 X-coordinate {m}
  1945. 5, !- Vertex 1 Y-coordinate {m}
  1946. 3.05, !- Vertex 1 Z-coordinate {m}
  1947. 22.69, !- Vertex 2 X-coordinate {m}
  1948. 5, !- Vertex 2 Y-coordinate {m}
  1949. 0, !- Vertex 2 Z-coordinate {m}
  1950. 5, !- Vertex 3 X-coordinate {m}
  1951. 5, !- Vertex 3 Y-coordinate {m}
  1952. 0, !- Vertex 3 Z-coordinate {m}
  1953. 5, !- Vertex 4 X-coordinate {m}
  1954. 5, !- Vertex 4 Y-coordinate {m}
  1955. 3.05; !- Vertex 4 Z-coordinate {m}
  1956.  
  1957. BuildingSurface:Detailed,
  1958. Perimeter_ZN_1_wall_south, !- Name
  1959. Wall, !- Surface Type
  1960. Mass Non-res Ext Wall, !- Construction Name
  1961. Perimeter_ZN_1 Thermal Zone, !- Zone Name
  1962. Outdoors, !- Outside Boundary Condition
  1963. , !- Outside Boundary Condition Object
  1964. SunExposed, !- Sun Exposure
  1965. WindExposed, !- Wind Exposure
  1966. , !- View Factor to Ground
  1967. , !- Number of Vertices
  1968. 0, !- Vertex 1 X-coordinate {m}
  1969. 0, !- Vertex 1 Y-coordinate {m}
  1970. 3.05, !- Vertex 1 Z-coordinate {m}
  1971. 0, !- Vertex 2 X-coordinate {m}
  1972. 0, !- Vertex 2 Y-coordinate {m}
  1973. 0, !- Vertex 2 Z-coordinate {m}
  1974. 27.69, !- Vertex 3 X-coordinate {m}
  1975. 0, !- Vertex 3 Y-coordinate {m}
  1976. 0, !- Vertex 3 Z-coordinate {m}
  1977. 27.69, !- Vertex 4 X-coordinate {m}
  1978. 0, !- Vertex 4 Y-coordinate {m}
  1979. 3.05; !- Vertex 4 Z-coordinate {m}
  1980.  
  1981. BuildingSurface:Detailed,
  1982. Perimeter_ZN_1_wall_west,!- Name
  1983. Wall, !- Surface Type
  1984. int-walls, !- Construction Name
  1985. Perimeter_ZN_1 Thermal Zone, !- Zone Name
  1986. Surface, !- Outside Boundary Condition
  1987. Perimeter_ZN_4_wall_south, !- Outside Boundary Condition Object
  1988. NoSun, !- Sun Exposure
  1989. NoWind, !- Wind Exposure
  1990. , !- View Factor to Ground
  1991. , !- Number of Vertices
  1992. 5, !- Vertex 1 X-coordinate {m}
  1993. 5, !- Vertex 1 Y-coordinate {m}
  1994. 3.05, !- Vertex 1 Z-coordinate {m}
  1995. 5, !- Vertex 2 X-coordinate {m}
  1996. 5, !- Vertex 2 Y-coordinate {m}
  1997. 0, !- Vertex 2 Z-coordinate {m}
  1998. 0, !- Vertex 3 X-coordinate {m}
  1999. 0, !- Vertex 3 Y-coordinate {m}
  2000. 0, !- Vertex 3 Z-coordinate {m}
  2001. 0, !- Vertex 4 X-coordinate {m}
  2002. 0, !- Vertex 4 Y-coordinate {m}
  2003. 3.05; !- Vertex 4 Z-coordinate {m}
  2004.  
  2005. BuildingSurface:Detailed,
  2006. Perimeter_ZN_2_ceiling, !- Name
  2007. Ceiling, !- Surface Type
  2008. Attic Non-res Floor, !- Construction Name
  2009. Perimeter_ZN_2 Thermal Zone, !- Zone Name
  2010. Surface, !- Outside Boundary Condition
  2011. Attic_floor_perimeter_east, !- Outside Boundary Condition Object
  2012. NoSun, !- Sun Exposure
  2013. NoWind, !- Wind Exposure
  2014. , !- View Factor to Ground
  2015. , !- Number of Vertices
  2016. 27.69, !- Vertex 1 X-coordinate {m}
  2017. 0, !- Vertex 1 Y-coordinate {m}
  2018. 3.05, !- Vertex 1 Z-coordinate {m}
  2019. 27.69, !- Vertex 2 X-coordinate {m}
  2020. 18.46, !- Vertex 2 Y-coordinate {m}
  2021. 3.05, !- Vertex 2 Z-coordinate {m}
  2022. 22.69, !- Vertex 3 X-coordinate {m}
  2023. 13.46, !- Vertex 3 Y-coordinate {m}
  2024. 3.05, !- Vertex 3 Z-coordinate {m}
  2025. 22.69, !- Vertex 4 X-coordinate {m}
  2026. 5, !- Vertex 4 Y-coordinate {m}
  2027. 3.05; !- Vertex 4 Z-coordinate {m}
  2028.  
  2029. BuildingSurface:Detailed,
  2030. Perimeter_ZN_2_floor, !- Name
  2031. Floor, !- Surface Type
  2032. ext-slab, !- Construction Name
  2033. Perimeter_ZN_2 Thermal Zone, !- Zone Name
  2034. Ground, !- Outside Boundary Condition
  2035. , !- Outside Boundary Condition Object
  2036. NoSun, !- Sun Exposure
  2037. NoWind, !- Wind Exposure
  2038. autocalculate, !- View Factor to Ground
  2039. , !- Number of Vertices
  2040. 27.69, !- Vertex 1 X-coordinate {m}
  2041. 18.46, !- Vertex 1 Y-coordinate {m}
  2042. 0, !- Vertex 1 Z-coordinate {m}
  2043. 27.69, !- Vertex 2 X-coordinate {m}
  2044. 0, !- Vertex 2 Y-coordinate {m}
  2045. 0, !- Vertex 2 Z-coordinate {m}
  2046. 22.69, !- Vertex 3 X-coordinate {m}
  2047. 5, !- Vertex 3 Y-coordinate {m}
  2048. 0, !- Vertex 3 Z-coordinate {m}
  2049. 22.69, !- Vertex 4 X-coordinate {m}
  2050. 13.46, !- Vertex 4 Y-coordinate {m}
  2051. 0; !- Vertex 4 Z-coordinate {m}
  2052.  
  2053. BuildingSurface:Detailed,
  2054. Perimeter_ZN_2_wall_east,!- Name
  2055. Wall, !- Surface Type
  2056. Mass Non-res Ext Wall, !- Construction Name
  2057. Perimeter_ZN_2 Thermal Zone, !- Zone Name
  2058. Outdoors, !- Outside Boundary Condition
  2059. , !- Outside Boundary Condition Object
  2060. SunExposed, !- Sun Exposure
  2061. WindExposed, !- Wind Exposure
  2062. , !- View Factor to Ground
  2063. , !- Number of Vertices
  2064. 27.69, !- Vertex 1 X-coordinate {m}
  2065. 0, !- Vertex 1 Y-coordinate {m}
  2066. 3.05, !- Vertex 1 Z-coordinate {m}
  2067. 27.69, !- Vertex 2 X-coordinate {m}
  2068. 0, !- Vertex 2 Y-coordinate {m}
  2069. 0, !- Vertex 2 Z-coordinate {m}
  2070. 27.69, !- Vertex 3 X-coordinate {m}
  2071. 18.46, !- Vertex 3 Y-coordinate {m}
  2072. 0, !- Vertex 3 Z-coordinate {m}
  2073. 27.69, !- Vertex 4 X-coordinate {m}
  2074. 18.46, !- Vertex 4 Y-coordinate {m}
  2075. 3.05; !- Vertex 4 Z-coordinate {m}
  2076.  
  2077. BuildingSurface:Detailed,
  2078. Perimeter_ZN_2_wall_north, !- Name
  2079. Wall, !- Surface Type
  2080. int-walls, !- Construction Name
  2081. Perimeter_ZN_2 Thermal Zone, !- Zone Name
  2082. Surface, !- Outside Boundary Condition
  2083. Perimeter_ZN_3_wall_east,!- Outside Boundary Condition Object
  2084. NoSun, !- Sun Exposure
  2085. NoWind, !- Wind Exposure
  2086. , !- View Factor to Ground
  2087. , !- Number of Vertices
  2088. 27.69, !- Vertex 1 X-coordinate {m}
  2089. 18.46, !- Vertex 1 Y-coordinate {m}
  2090. 3.05, !- Vertex 1 Z-coordinate {m}
  2091. 27.69, !- Vertex 2 X-coordinate {m}
  2092. 18.46, !- Vertex 2 Y-coordinate {m}
  2093. 0, !- Vertex 2 Z-coordinate {m}
  2094. 22.69, !- Vertex 3 X-coordinate {m}
  2095. 13.46, !- Vertex 3 Y-coordinate {m}
  2096. 0, !- Vertex 3 Z-coordinate {m}
  2097. 22.69, !- Vertex 4 X-coordinate {m}
  2098. 13.46, !- Vertex 4 Y-coordinate {m}
  2099. 3.05; !- Vertex 4 Z-coordinate {m}
  2100.  
  2101. BuildingSurface:Detailed,
  2102. Perimeter_ZN_2_wall_south, !- Name
  2103. Wall, !- Surface Type
  2104. int-walls, !- Construction Name
  2105. Perimeter_ZN_2 Thermal Zone, !- Zone Name
  2106. Surface, !- Outside Boundary Condition
  2107. Perimeter_ZN_1_wall_east,!- Outside Boundary Condition Object
  2108. NoSun, !- Sun Exposure
  2109. NoWind, !- Wind Exposure
  2110. , !- View Factor to Ground
  2111. , !- Number of Vertices
  2112. 22.69, !- Vertex 1 X-coordinate {m}
  2113. 5, !- Vertex 1 Y-coordinate {m}
  2114. 3.05, !- Vertex 1 Z-coordinate {m}
  2115. 22.69, !- Vertex 2 X-coordinate {m}
  2116. 5, !- Vertex 2 Y-coordinate {m}
  2117. 0, !- Vertex 2 Z-coordinate {m}
  2118. 27.69, !- Vertex 3 X-coordinate {m}
  2119. 2.04187384066908e-015, !- Vertex 3 Y-coordinate {m}
  2120. 0, !- Vertex 3 Z-coordinate {m}
  2121. 27.69, !- Vertex 4 X-coordinate {m}
  2122. 2.04187384066908e-015, !- Vertex 4 Y-coordinate {m}
  2123. 3.05; !- Vertex 4 Z-coordinate {m}
  2124.  
  2125. BuildingSurface:Detailed,
  2126. Perimeter_ZN_2_wall_west,!- Name
  2127. Wall, !- Surface Type
  2128. int-walls, !- Construction Name
  2129. Perimeter_ZN_2 Thermal Zone, !- Zone Name
  2130. Surface, !- Outside Boundary Condition
  2131. Core_ZN_wall_east, !- Outside Boundary Condition Object
  2132. NoSun, !- Sun Exposure
  2133. NoWind, !- Wind Exposure
  2134. , !- View Factor to Ground
  2135. , !- Number of Vertices
  2136. 22.69, !- Vertex 1 X-coordinate {m}
  2137. 13.46, !- Vertex 1 Y-coordinate {m}
  2138. 3.05, !- Vertex 1 Z-coordinate {m}
  2139. 22.69, !- Vertex 2 X-coordinate {m}
  2140. 13.46, !- Vertex 2 Y-coordinate {m}
  2141. 0, !- Vertex 2 Z-coordinate {m}
  2142. 22.69, !- Vertex 3 X-coordinate {m}
  2143. 5, !- Vertex 3 Y-coordinate {m}
  2144. 0, !- Vertex 3 Z-coordinate {m}
  2145. 22.69, !- Vertex 4 X-coordinate {m}
  2146. 5, !- Vertex 4 Y-coordinate {m}
  2147. 3.05; !- Vertex 4 Z-coordinate {m}
  2148.  
  2149. BuildingSurface:Detailed,
  2150. Perimeter_ZN_3_ceiling, !- Name
  2151. Ceiling, !- Surface Type
  2152. Attic Non-res Floor, !- Construction Name
  2153. Perimeter_ZN_3 Thermal Zone, !- Zone Name
  2154. Surface, !- Outside Boundary Condition
  2155. Attic_floor_perimeter_north, !- Outside Boundary Condition Object
  2156. NoSun, !- Sun Exposure
  2157. NoWind, !- Wind Exposure
  2158. , !- View Factor to Ground
  2159. , !- Number of Vertices
  2160. 22.69, !- Vertex 1 X-coordinate {m}
  2161. 13.46, !- Vertex 1 Y-coordinate {m}
  2162. 3.05, !- Vertex 1 Z-coordinate {m}
  2163. 27.69, !- Vertex 2 X-coordinate {m}
  2164. 18.46, !- Vertex 2 Y-coordinate {m}
  2165. 3.05, !- Vertex 2 Z-coordinate {m}
  2166. 0, !- Vertex 3 X-coordinate {m}
  2167. 18.46, !- Vertex 3 Y-coordinate {m}
  2168. 3.05, !- Vertex 3 Z-coordinate {m}
  2169. 5, !- Vertex 4 X-coordinate {m}
  2170. 13.46, !- Vertex 4 Y-coordinate {m}
  2171. 3.05; !- Vertex 4 Z-coordinate {m}
  2172.  
  2173. BuildingSurface:Detailed,
  2174. Perimeter_ZN_3_floor, !- Name
  2175. Floor, !- Surface Type
  2176. ext-slab, !- Construction Name
  2177. Perimeter_ZN_3 Thermal Zone, !- Zone Name
  2178. Ground, !- Outside Boundary Condition
  2179. , !- Outside Boundary Condition Object
  2180. NoSun, !- Sun Exposure
  2181. NoWind, !- Wind Exposure
  2182. autocalculate, !- View Factor to Ground
  2183. , !- Number of Vertices
  2184. 27.69, !- Vertex 1 X-coordinate {m}
  2185. 18.46, !- Vertex 1 Y-coordinate {m}
  2186. 0, !- Vertex 1 Z-coordinate {m}
  2187. 22.69, !- Vertex 2 X-coordinate {m}
  2188. 13.46, !- Vertex 2 Y-coordinate {m}
  2189. 0, !- Vertex 2 Z-coordinate {m}
  2190. 5, !- Vertex 3 X-coordinate {m}
  2191. 13.46, !- Vertex 3 Y-coordinate {m}
  2192. 0, !- Vertex 3 Z-coordinate {m}
  2193. 0, !- Vertex 4 X-coordinate {m}
  2194. 18.46, !- Vertex 4 Y-coordinate {m}
  2195. 0; !- Vertex 4 Z-coordinate {m}
  2196.  
  2197. BuildingSurface:Detailed,
  2198. Perimeter_ZN_3_wall_east,!- Name
  2199. Wall, !- Surface Type
  2200. int-walls, !- Construction Name
  2201. Perimeter_ZN_3 Thermal Zone, !- Zone Name
  2202. Surface, !- Outside Boundary Condition
  2203. Perimeter_ZN_2_wall_north, !- Outside Boundary Condition Object
  2204. NoSun, !- Sun Exposure
  2205. NoWind, !- Wind Exposure
  2206. , !- View Factor to Ground
  2207. , !- Number of Vertices
  2208. 22.69, !- Vertex 1 X-coordinate {m}
  2209. 13.46, !- Vertex 1 Y-coordinate {m}
  2210. 3.05, !- Vertex 1 Z-coordinate {m}
  2211. 22.69, !- Vertex 2 X-coordinate {m}
  2212. 13.46, !- Vertex 2 Y-coordinate {m}
  2213. 0, !- Vertex 2 Z-coordinate {m}
  2214. 27.69, !- Vertex 3 X-coordinate {m}
  2215. 18.46, !- Vertex 3 Y-coordinate {m}
  2216. 0, !- Vertex 3 Z-coordinate {m}
  2217. 27.69, !- Vertex 4 X-coordinate {m}
  2218. 18.46, !- Vertex 4 Y-coordinate {m}
  2219. 3.05; !- Vertex 4 Z-coordinate {m}
  2220.  
  2221. BuildingSurface:Detailed,
  2222. Perimeter_ZN_3_wall_north, !- Name
  2223. Wall, !- Surface Type
  2224. Mass Non-res Ext Wall, !- Construction Name
  2225. Perimeter_ZN_3 Thermal Zone, !- Zone Name
  2226. Outdoors, !- Outside Boundary Condition
  2227. , !- Outside Boundary Condition Object
  2228. SunExposed, !- Sun Exposure
  2229. WindExposed, !- Wind Exposure
  2230. , !- View Factor to Ground
  2231. , !- Number of Vertices
  2232. 27.69, !- Vertex 1 X-coordinate {m}
  2233. 18.46, !- Vertex 1 Y-coordinate {m}
  2234. 3.05, !- Vertex 1 Z-coordinate {m}
  2235. 27.69, !- Vertex 2 X-coordinate {m}
  2236. 18.46, !- Vertex 2 Y-coordinate {m}
  2237. 0, !- Vertex 2 Z-coordinate {m}
  2238. 0, !- Vertex 3 X-coordinate {m}
  2239. 18.46, !- Vertex 3 Y-coordinate {m}
  2240. 0, !- Vertex 3 Z-coordinate {m}
  2241. 0, !- Vertex 4 X-coordinate {m}
  2242. 18.46, !- Vertex 4 Y-coordinate {m}
  2243. 3.05; !- Vertex 4 Z-coordinate {m}
  2244.  
  2245. BuildingSurface:Detailed,
  2246. Perimeter_ZN_3_wall_south, !- Name
  2247. Wall, !- Surface Type
  2248. int-walls, !- Construction Name
  2249. Perimeter_ZN_3 Thermal Zone, !- Zone Name
  2250. Surface, !- Outside Boundary Condition
  2251. Core_ZN_wall_north, !- Outside Boundary Condition Object
  2252. NoSun, !- Sun Exposure
  2253. NoWind, !- Wind Exposure
  2254. , !- View Factor to Ground
  2255. , !- Number of Vertices
  2256. 5, !- Vertex 1 X-coordinate {m}
  2257. 13.46, !- Vertex 1 Y-coordinate {m}
  2258. 3.05, !- Vertex 1 Z-coordinate {m}
  2259. 5, !- Vertex 2 X-coordinate {m}
  2260. 13.46, !- Vertex 2 Y-coordinate {m}
  2261. 0, !- Vertex 2 Z-coordinate {m}
  2262. 22.69, !- Vertex 3 X-coordinate {m}
  2263. 13.46, !- Vertex 3 Y-coordinate {m}
  2264. 0, !- Vertex 3 Z-coordinate {m}
  2265. 22.69, !- Vertex 4 X-coordinate {m}
  2266. 13.46, !- Vertex 4 Y-coordinate {m}
  2267. 3.05; !- Vertex 4 Z-coordinate {m}
  2268.  
  2269. BuildingSurface:Detailed,
  2270. Perimeter_ZN_3_wall_west,!- Name
  2271. Wall, !- Surface Type
  2272. int-walls, !- Construction Name
  2273. Perimeter_ZN_3 Thermal Zone, !- Zone Name
  2274. Surface, !- Outside Boundary Condition
  2275. Perimeter_ZN_4_wall_north, !- Outside Boundary Condition Object
  2276. NoSun, !- Sun Exposure
  2277. NoWind, !- Wind Exposure
  2278. , !- View Factor to Ground
  2279. , !- Number of Vertices
  2280. 0, !- Vertex 1 X-coordinate {m}
  2281. 18.46, !- Vertex 1 Y-coordinate {m}
  2282. 3.05, !- Vertex 1 Z-coordinate {m}
  2283. 0, !- Vertex 2 X-coordinate {m}
  2284. 18.46, !- Vertex 2 Y-coordinate {m}
  2285. 0, !- Vertex 2 Z-coordinate {m}
  2286. 5, !- Vertex 3 X-coordinate {m}
  2287. 13.46, !- Vertex 3 Y-coordinate {m}
  2288. 0, !- Vertex 3 Z-coordinate {m}
  2289. 5, !- Vertex 4 X-coordinate {m}
  2290. 13.46, !- Vertex 4 Y-coordinate {m}
  2291. 3.05; !- Vertex 4 Z-coordinate {m}
  2292.  
  2293. BuildingSurface:Detailed,
  2294. Perimeter_ZN_4_ceiling, !- Name
  2295. Ceiling, !- Surface Type
  2296. Attic Non-res Floor, !- Construction Name
  2297. Perimeter_ZN_4 Thermal Zone, !- Zone Name
  2298. Surface, !- Outside Boundary Condition
  2299. Attic_floor_perimeter_west, !- Outside Boundary Condition Object
  2300. NoSun, !- Sun Exposure
  2301. NoWind, !- Wind Exposure
  2302. , !- View Factor to Ground
  2303. , !- Number of Vertices
  2304. 0, !- Vertex 1 X-coordinate {m}
  2305. 0, !- Vertex 1 Y-coordinate {m}
  2306. 3.05, !- Vertex 1 Z-coordinate {m}
  2307. 5, !- Vertex 2 X-coordinate {m}
  2308. 5, !- Vertex 2 Y-coordinate {m}
  2309. 3.05, !- Vertex 2 Z-coordinate {m}
  2310. 5, !- Vertex 3 X-coordinate {m}
  2311. 13.46, !- Vertex 3 Y-coordinate {m}
  2312. 3.05, !- Vertex 3 Z-coordinate {m}
  2313. 0, !- Vertex 4 X-coordinate {m}
  2314. 18.46, !- Vertex 4 Y-coordinate {m}
  2315. 3.05; !- Vertex 4 Z-coordinate {m}
  2316.  
  2317. BuildingSurface:Detailed,
  2318. Perimeter_ZN_4_floor, !- Name
  2319. Floor, !- Surface Type
  2320. ext-slab, !- Construction Name
  2321. Perimeter_ZN_4 Thermal Zone, !- Zone Name
  2322. Ground, !- Outside Boundary Condition
  2323. , !- Outside Boundary Condition Object
  2324. NoSun, !- Sun Exposure
  2325. NoWind, !- Wind Exposure
  2326. autocalculate, !- View Factor to Ground
  2327. , !- Number of Vertices
  2328. 0, !- Vertex 1 X-coordinate {m}
  2329. 18.46, !- Vertex 1 Y-coordinate {m}
  2330. 0, !- Vertex 1 Z-coordinate {m}
  2331. 5, !- Vertex 2 X-coordinate {m}
  2332. 13.46, !- Vertex 2 Y-coordinate {m}
  2333. 0, !- Vertex 2 Z-coordinate {m}
  2334. 5, !- Vertex 3 X-coordinate {m}
  2335. 5, !- Vertex 3 Y-coordinate {m}
  2336. 0, !- Vertex 3 Z-coordinate {m}
  2337. 0, !- Vertex 4 X-coordinate {m}
  2338. 0, !- Vertex 4 Y-coordinate {m}
  2339. 0; !- Vertex 4 Z-coordinate {m}
  2340.  
  2341. BuildingSurface:Detailed,
  2342. Perimeter_ZN_4_wall_east,!- Name
  2343. Wall, !- Surface Type
  2344. int-walls, !- Construction Name
  2345. Perimeter_ZN_4 Thermal Zone, !- Zone Name
  2346. Surface, !- Outside Boundary Condition
  2347. Core_ZN_wall_west, !- Outside Boundary Condition Object
  2348. NoSun, !- Sun Exposure
  2349. NoWind, !- Wind Exposure
  2350. , !- View Factor to Ground
  2351. , !- Number of Vertices
  2352. 5, !- Vertex 1 X-coordinate {m}
  2353. 5, !- Vertex 1 Y-coordinate {m}
  2354. 3.05, !- Vertex 1 Z-coordinate {m}
  2355. 5, !- Vertex 2 X-coordinate {m}
  2356. 5, !- Vertex 2 Y-coordinate {m}
  2357. 0, !- Vertex 2 Z-coordinate {m}
  2358. 5, !- Vertex 3 X-coordinate {m}
  2359. 13.46, !- Vertex 3 Y-coordinate {m}
  2360. 0, !- Vertex 3 Z-coordinate {m}
  2361. 5, !- Vertex 4 X-coordinate {m}
  2362. 13.46, !- Vertex 4 Y-coordinate {m}
  2363. 3.05; !- Vertex 4 Z-coordinate {m}
  2364.  
  2365. BuildingSurface:Detailed,
  2366. Perimeter_ZN_4_wall_north, !- Name
  2367. Wall, !- Surface Type
  2368. int-walls, !- Construction Name
  2369. Perimeter_ZN_4 Thermal Zone, !- Zone Name
  2370. Surface, !- Outside Boundary Condition
  2371. Perimeter_ZN_3_wall_west,!- Outside Boundary Condition Object
  2372. NoSun, !- Sun Exposure
  2373. NoWind, !- Wind Exposure
  2374. , !- View Factor to Ground
  2375. , !- Number of Vertices
  2376. 5, !- Vertex 1 X-coordinate {m}
  2377. 13.46, !- Vertex 1 Y-coordinate {m}
  2378. 3.05, !- Vertex 1 Z-coordinate {m}
  2379. 5, !- Vertex 2 X-coordinate {m}
  2380. 13.46, !- Vertex 2 Y-coordinate {m}
  2381. 0, !- Vertex 2 Z-coordinate {m}
  2382. 0, !- Vertex 3 X-coordinate {m}
  2383. 18.46, !- Vertex 3 Y-coordinate {m}
  2384. 0, !- Vertex 3 Z-coordinate {m}
  2385. 0, !- Vertex 4 X-coordinate {m}
  2386. 18.46, !- Vertex 4 Y-coordinate {m}
  2387. 3.05; !- Vertex 4 Z-coordinate {m}
  2388.  
  2389. BuildingSurface:Detailed,
  2390. Perimeter_ZN_4_wall_south, !- Name
  2391. Wall, !- Surface Type
  2392. int-walls, !- Construction Name
  2393. Perimeter_ZN_4 Thermal Zone, !- Zone Name
  2394. Surface, !- Outside Boundary Condition
  2395. Perimeter_ZN_1_wall_west,!- Outside Boundary Condition Object
  2396. NoSun, !- Sun Exposure
  2397. NoWind, !- Wind Exposure
  2398. , !- View Factor to Ground
  2399. , !- Number of Vertices
  2400. 0, !- Vertex 1 X-coordinate {m}
  2401. 0, !- Vertex 1 Y-coordinate {m}
  2402. 3.05, !- Vertex 1 Z-coordinate {m}
  2403. 0, !- Vertex 2 X-coordinate {m}
  2404. 0, !- Vertex 2 Y-coordinate {m}
  2405. 0, !- Vertex 2 Z-coordinate {m}
  2406. 5, !- Vertex 3 X-coordinate {m}
  2407. 5, !- Vertex 3 Y-coordinate {m}
  2408. 0, !- Vertex 3 Z-coordinate {m}
  2409. 5, !- Vertex 4 X-coordinate {m}
  2410. 5, !- Vertex 4 Y-coordinate {m}
  2411. 3.05; !- Vertex 4 Z-coordinate {m}
  2412.  
  2413. BuildingSurface:Detailed,
  2414. Perimeter_ZN_4_wall_west,!- Name
  2415. Wall, !- Surface Type
  2416. Mass Non-res Ext Wall, !- Construction Name
  2417. Perimeter_ZN_4 Thermal Zone, !- Zone Name
  2418. Outdoors, !- Outside Boundary Condition
  2419. , !- Outside Boundary Condition Object
  2420. SunExposed, !- Sun Exposure
  2421. WindExposed, !- Wind Exposure
  2422. , !- View Factor to Ground
  2423. , !- Number of Vertices
  2424. 0, !- Vertex 1 X-coordinate {m}
  2425. 18.46, !- Vertex 1 Y-coordinate {m}
  2426. 3.05, !- Vertex 1 Z-coordinate {m}
  2427. 0, !- Vertex 2 X-coordinate {m}
  2428. 18.46, !- Vertex 2 Y-coordinate {m}
  2429. 0, !- Vertex 2 Z-coordinate {m}
  2430. 0, !- Vertex 3 X-coordinate {m}
  2431. 0, !- Vertex 3 Y-coordinate {m}
  2432. 0, !- Vertex 3 Z-coordinate {m}
  2433. 0, !- Vertex 4 X-coordinate {m}
  2434. 0, !- Vertex 4 Y-coordinate {m}
  2435. 3.05; !- Vertex 4 Z-coordinate {m}
  2436.  
  2437.  
  2438. !- =========== ALL OBJECTS IN CLASS: FENESTRATIONSURFACE:DETAILED ===========
  2439.  
  2440. FenestrationSurface:Detailed,
  2441. Perimeter_ZN_1_wall_south_door, !- Name
  2442. GlassDoor, !- Surface Type
  2443. Window Non-res Fixed, !- Construction Name
  2444. Perimeter_ZN_1_wall_south, !- Building Surface Name
  2445. , !- Outside Boundary Condition Object
  2446. , !- View Factor to Ground
  2447. , !- Shading Control Name
  2448. , !- Frame and Divider Name
  2449. 1, !- Multiplier
  2450. , !- Number of Vertices
  2451. 12.93, !- Vertex 1 X-coordinate {m}
  2452. 0, !- Vertex 1 Y-coordinate {m}
  2453. 2.134, !- Vertex 1 Z-coordinate {m}
  2454. 12.93, !- Vertex 2 X-coordinate {m}
  2455. 0, !- Vertex 2 Y-coordinate {m}
  2456. 0, !- Vertex 2 Z-coordinate {m}
  2457. 14.76, !- Vertex 3 X-coordinate {m}
  2458. 0, !- Vertex 3 Y-coordinate {m}
  2459. 0, !- Vertex 3 Z-coordinate {m}
  2460. 14.76, !- Vertex 4 X-coordinate {m}
  2461. 0, !- Vertex 4 Y-coordinate {m}
  2462. 2.134; !- Vertex 4 Z-coordinate {m}
  2463.  
  2464. FenestrationSurface:Detailed,
  2465. Perimeter_ZN_1_wall_south_Window_1, !- Name
  2466. Window, !- Surface Type
  2467. Window Non-res Fixed, !- Construction Name
  2468. Perimeter_ZN_1_wall_south, !- Building Surface Name
  2469. , !- Outside Boundary Condition Object
  2470. , !- View Factor to Ground
  2471. , !- Shading Control Name
  2472. , !- Frame and Divider Name
  2473. 1, !- Multiplier
  2474. , !- Number of Vertices
  2475. 1.39, !- Vertex 1 X-coordinate {m}
  2476. 0, !- Vertex 1 Y-coordinate {m}
  2477. 2.424, !- Vertex 1 Z-coordinate {m}
  2478. 1.39, !- Vertex 2 X-coordinate {m}
  2479. 0, !- Vertex 2 Y-coordinate {m}
  2480. 0.9, !- Vertex 2 Z-coordinate {m}
  2481. 3.22, !- Vertex 3 X-coordinate {m}
  2482. 0, !- Vertex 3 Y-coordinate {m}
  2483. 0.9, !- Vertex 3 Z-coordinate {m}
  2484. 3.22, !- Vertex 4 X-coordinate {m}
  2485. 0, !- Vertex 4 Y-coordinate {m}
  2486. 2.424; !- Vertex 4 Z-coordinate {m}
  2487.  
  2488. FenestrationSurface:Detailed,
  2489. Perimeter_ZN_1_wall_south_Window_2, !- Name
  2490. Window, !- Surface Type
  2491. Window Non-res Fixed, !- Construction Name
  2492. Perimeter_ZN_1_wall_south, !- Building Surface Name
  2493. , !- Outside Boundary Condition Object
  2494. , !- View Factor to Ground
  2495. , !- Shading Control Name
  2496. , !- Frame and Divider Name
  2497. 1, !- Multiplier
  2498. , !- Number of Vertices
  2499. 6.01, !- Vertex 1 X-coordinate {m}
  2500. 0, !- Vertex 1 Y-coordinate {m}
  2501. 2.424, !- Vertex 1 Z-coordinate {m}
  2502. 6.01, !- Vertex 2 X-coordinate {m}
  2503. 0, !- Vertex 2 Y-coordinate {m}
  2504. 0.9, !- Vertex 2 Z-coordinate {m}
  2505. 7.84, !- Vertex 3 X-coordinate {m}
  2506. 0, !- Vertex 3 Y-coordinate {m}
  2507. 0.9, !- Vertex 3 Z-coordinate {m}
  2508. 7.84, !- Vertex 4 X-coordinate {m}
  2509. 0, !- Vertex 4 Y-coordinate {m}
  2510. 2.424; !- Vertex 4 Z-coordinate {m}
  2511.  
  2512. FenestrationSurface:Detailed,
  2513. Perimeter_ZN_1_wall_south_Window_3, !- Name
  2514. Window, !- Surface Type
  2515. Window Non-res Fixed, !- Construction Name
  2516. Perimeter_ZN_1_wall_south, !- Building Surface Name
  2517. , !- Outside Boundary Condition Object
  2518. , !- View Factor to Ground
  2519. , !- Shading Control Name
  2520. , !- Frame and Divider Name
  2521. 1, !- Multiplier
  2522. , !- Number of Vertices
  2523. 10.62, !- Vertex 1 X-coordinate {m}
  2524. 0, !- Vertex 1 Y-coordinate {m}
  2525. 2.424, !- Vertex 1 Z-coordinate {m}
  2526. 10.62, !- Vertex 2 X-coordinate {m}
  2527. 0, !- Vertex 2 Y-coordinate {m}
  2528. 0.9, !- Vertex 2 Z-coordinate {m}
  2529. 12.45, !- Vertex 3 X-coordinate {m}
  2530. 0, !- Vertex 3 Y-coordinate {m}
  2531. 0.9, !- Vertex 3 Z-coordinate {m}
  2532. 12.45, !- Vertex 4 X-coordinate {m}
  2533. 0, !- Vertex 4 Y-coordinate {m}
  2534. 2.424; !- Vertex 4 Z-coordinate {m}
  2535.  
  2536. FenestrationSurface:Detailed,
  2537. Perimeter_ZN_1_wall_south_Window_4, !- Name
  2538. Window, !- Surface Type
  2539. Window Non-res Fixed, !- Construction Name
  2540. Perimeter_ZN_1_wall_south, !- Building Surface Name
  2541. , !- Outside Boundary Condition Object
  2542. , !- View Factor to Ground
  2543. , !- Shading Control Name
  2544. , !- Frame and Divider Name
  2545. 1, !- Multiplier
  2546. , !- Number of Vertices
  2547. 15.24, !- Vertex 1 X-coordinate {m}
  2548. 0, !- Vertex 1 Y-coordinate {m}
  2549. 2.424, !- Vertex 1 Z-coordinate {m}
  2550. 15.24, !- Vertex 2 X-coordinate {m}
  2551. 0, !- Vertex 2 Y-coordinate {m}
  2552. 0.9, !- Vertex 2 Z-coordinate {m}
  2553. 17.07, !- Vertex 3 X-coordinate {m}
  2554. 0, !- Vertex 3 Y-coordinate {m}
  2555. 0.9, !- Vertex 3 Z-coordinate {m}
  2556. 17.07, !- Vertex 4 X-coordinate {m}
  2557. 0, !- Vertex 4 Y-coordinate {m}
  2558. 2.424; !- Vertex 4 Z-coordinate {m}
  2559.  
  2560. FenestrationSurface:Detailed,
  2561. Perimeter_ZN_1_wall_south_Window_5, !- Name
  2562. Window, !- Surface Type
  2563. Window Non-res Fixed, !- Construction Name
  2564. Perimeter_ZN_1_wall_south, !- Building Surface Name
  2565. , !- Outside Boundary Condition Object
  2566. , !- View Factor to Ground
  2567. , !- Shading Control Name
  2568. , !- Frame and Divider Name
  2569. 1, !- Multiplier
  2570. , !- Number of Vertices
  2571. 19.85, !- Vertex 1 X-coordinate {m}
  2572. 0, !- Vertex 1 Y-coordinate {m}
  2573. 2.424, !- Vertex 1 Z-coordinate {m}
  2574. 19.85, !- Vertex 2 X-coordinate {m}
  2575. 0, !- Vertex 2 Y-coordinate {m}
  2576. 0.9, !- Vertex 2 Z-coordinate {m}
  2577. 21.68, !- Vertex 3 X-coordinate {m}
  2578. 0, !- Vertex 3 Y-coordinate {m}
  2579. 0.9, !- Vertex 3 Z-coordinate {m}
  2580. 21.68, !- Vertex 4 X-coordinate {m}
  2581. 0, !- Vertex 4 Y-coordinate {m}
  2582. 2.424; !- Vertex 4 Z-coordinate {m}
  2583.  
  2584. FenestrationSurface:Detailed,
  2585. Perimeter_ZN_1_wall_south_Window_6, !- Name
  2586. Window, !- Surface Type
  2587. Window Non-res Fixed, !- Construction Name
  2588. Perimeter_ZN_1_wall_south, !- Building Surface Name
  2589. , !- Outside Boundary Condition Object
  2590. , !- View Factor to Ground
  2591. , !- Shading Control Name
  2592. , !- Frame and Divider Name
  2593. 1, !- Multiplier
  2594. , !- Number of Vertices
  2595. 24.47, !- Vertex 1 X-coordinate {m}
  2596. 0, !- Vertex 1 Y-coordinate {m}
  2597. 2.424, !- Vertex 1 Z-coordinate {m}
  2598. 24.47, !- Vertex 2 X-coordinate {m}
  2599. 0, !- Vertex 2 Y-coordinate {m}
  2600. 0.9, !- Vertex 2 Z-coordinate {m}
  2601. 26.3, !- Vertex 3 X-coordinate {m}
  2602. 0, !- Vertex 3 Y-coordinate {m}
  2603. 0.9, !- Vertex 3 Z-coordinate {m}
  2604. 26.3, !- Vertex 4 X-coordinate {m}
  2605. 0, !- Vertex 4 Y-coordinate {m}
  2606. 2.424; !- Vertex 4 Z-coordinate {m}
  2607.  
  2608. FenestrationSurface:Detailed,
  2609. Perimeter_ZN_2_wall_east_Window_1, !- Name
  2610. Window, !- Surface Type
  2611. Window Non-res Fixed, !- Construction Name
  2612. Perimeter_ZN_2_wall_east,!- Building Surface Name
  2613. , !- Outside Boundary Condition Object
  2614. , !- View Factor to Ground
  2615. , !- Shading Control Name
  2616. , !- Frame and Divider Name
  2617. 1, !- Multiplier
  2618. , !- Number of Vertices
  2619. 27.69, !- Vertex 1 X-coordinate {m}
  2620. 1.39, !- Vertex 1 Y-coordinate {m}
  2621. 2.424, !- Vertex 1 Z-coordinate {m}
  2622. 27.69, !- Vertex 2 X-coordinate {m}
  2623. 1.39, !- Vertex 2 Y-coordinate {m}
  2624. 0.9, !- Vertex 2 Z-coordinate {m}
  2625. 27.69, !- Vertex 3 X-coordinate {m}
  2626. 3.22, !- Vertex 3 Y-coordinate {m}
  2627. 0.9, !- Vertex 3 Z-coordinate {m}
  2628. 27.69, !- Vertex 4 X-coordinate {m}
  2629. 3.22, !- Vertex 4 Y-coordinate {m}
  2630. 2.424; !- Vertex 4 Z-coordinate {m}
  2631.  
  2632. FenestrationSurface:Detailed,
  2633. Perimeter_ZN_2_wall_east_Window_2, !- Name
  2634. Window, !- Surface Type
  2635. Window Non-res Fixed, !- Construction Name
  2636. Perimeter_ZN_2_wall_east,!- Building Surface Name
  2637. , !- Outside Boundary Condition Object
  2638. , !- View Factor to Ground
  2639. , !- Shading Control Name
  2640. , !- Frame and Divider Name
  2641. 1, !- Multiplier
  2642. , !- Number of Vertices
  2643. 27.69, !- Vertex 1 X-coordinate {m}
  2644. 6.01, !- Vertex 1 Y-coordinate {m}
  2645. 2.424, !- Vertex 1 Z-coordinate {m}
  2646. 27.69, !- Vertex 2 X-coordinate {m}
  2647. 6.01, !- Vertex 2 Y-coordinate {m}
  2648. 0.9, !- Vertex 2 Z-coordinate {m}
  2649. 27.69, !- Vertex 3 X-coordinate {m}
  2650. 7.84, !- Vertex 3 Y-coordinate {m}
  2651. 0.9, !- Vertex 3 Z-coordinate {m}
  2652. 27.69, !- Vertex 4 X-coordinate {m}
  2653. 7.84, !- Vertex 4 Y-coordinate {m}
  2654. 2.424; !- Vertex 4 Z-coordinate {m}
  2655.  
  2656. FenestrationSurface:Detailed,
  2657. Perimeter_ZN_2_wall_east_Window_3, !- Name
  2658. Window, !- Surface Type
  2659. Window Non-res Fixed, !- Construction Name
  2660. Perimeter_ZN_2_wall_east,!- Building Surface Name
  2661. , !- Outside Boundary Condition Object
  2662. , !- View Factor to Ground
  2663. , !- Shading Control Name
  2664. , !- Frame and Divider Name
  2665. 1, !- Multiplier
  2666. , !- Number of Vertices
  2667. 27.69, !- Vertex 1 X-coordinate {m}
  2668. 10.62, !- Vertex 1 Y-coordinate {m}
  2669. 2.424, !- Vertex 1 Z-coordinate {m}
  2670. 27.69, !- Vertex 2 X-coordinate {m}
  2671. 10.62, !- Vertex 2 Y-coordinate {m}
  2672. 0.9, !- Vertex 2 Z-coordinate {m}
  2673. 27.69, !- Vertex 3 X-coordinate {m}
  2674. 12.45, !- Vertex 3 Y-coordinate {m}
  2675. 0.9, !- Vertex 3 Z-coordinate {m}
  2676. 27.69, !- Vertex 4 X-coordinate {m}
  2677. 12.45, !- Vertex 4 Y-coordinate {m}
  2678. 2.424; !- Vertex 4 Z-coordinate {m}
  2679.  
  2680. FenestrationSurface:Detailed,
  2681. Perimeter_ZN_2_wall_east_Window_4, !- Name
  2682. Window, !- Surface Type
  2683. Window Non-res Fixed, !- Construction Name
  2684. Perimeter_ZN_2_wall_east,!- Building Surface Name
  2685. , !- Outside Boundary Condition Object
  2686. , !- View Factor to Ground
  2687. , !- Shading Control Name
  2688. , !- Frame and Divider Name
  2689. 1, !- Multiplier
  2690. , !- Number of Vertices
  2691. 27.69, !- Vertex 1 X-coordinate {m}
  2692. 15.24, !- Vertex 1 Y-coordinate {m}
  2693. 2.424, !- Vertex 1 Z-coordinate {m}
  2694. 27.69, !- Vertex 2 X-coordinate {m}
  2695. 15.24, !- Vertex 2 Y-coordinate {m}
  2696. 0.9, !- Vertex 2 Z-coordinate {m}
  2697. 27.69, !- Vertex 3 X-coordinate {m}
  2698. 17.07, !- Vertex 3 Y-coordinate {m}
  2699. 0.9, !- Vertex 3 Z-coordinate {m}
  2700. 27.69, !- Vertex 4 X-coordinate {m}
  2701. 17.07, !- Vertex 4 Y-coordinate {m}
  2702. 2.424; !- Vertex 4 Z-coordinate {m}
  2703.  
  2704. FenestrationSurface:Detailed,
  2705. Perimeter_ZN_3_wall_north_Window_1, !- Name
  2706. Window, !- Surface Type
  2707. Window Non-res Fixed, !- Construction Name
  2708. Perimeter_ZN_3_wall_north, !- Building Surface Name
  2709. , !- Outside Boundary Condition Object
  2710. , !- View Factor to Ground
  2711. , !- Shading Control Name
  2712. , !- Frame and Divider Name
  2713. 1, !- Multiplier
  2714. , !- Number of Vertices
  2715. 26.3, !- Vertex 1 X-coordinate {m}
  2716. 18.46, !- Vertex 1 Y-coordinate {m}
  2717. 2.424, !- Vertex 1 Z-coordinate {m}
  2718. 26.3, !- Vertex 2 X-coordinate {m}
  2719. 18.46, !- Vertex 2 Y-coordinate {m}
  2720. 0.9, !- Vertex 2 Z-coordinate {m}
  2721. 24.47, !- Vertex 3 X-coordinate {m}
  2722. 18.46, !- Vertex 3 Y-coordinate {m}
  2723. 0.9, !- Vertex 3 Z-coordinate {m}
  2724. 24.47, !- Vertex 4 X-coordinate {m}
  2725. 18.46, !- Vertex 4 Y-coordinate {m}
  2726. 2.424; !- Vertex 4 Z-coordinate {m}
  2727.  
  2728. FenestrationSurface:Detailed,
  2729. Perimeter_ZN_3_wall_north_Window_2, !- Name
  2730. Window, !- Surface Type
  2731. Window Non-res Fixed, !- Construction Name
  2732. Perimeter_ZN_3_wall_north, !- Building Surface Name
  2733. , !- Outside Boundary Condition Object
  2734. , !- View Factor to Ground
  2735. , !- Shading Control Name
  2736. , !- Frame and Divider Name
  2737. 1, !- Multiplier
  2738. , !- Number of Vertices
  2739. 21.68, !- Vertex 1 X-coordinate {m}
  2740. 18.46, !- Vertex 1 Y-coordinate {m}
  2741. 2.424, !- Vertex 1 Z-coordinate {m}
  2742. 21.68, !- Vertex 2 X-coordinate {m}
  2743. 18.46, !- Vertex 2 Y-coordinate {m}
  2744. 0.9, !- Vertex 2 Z-coordinate {m}
  2745. 19.85, !- Vertex 3 X-coordinate {m}
  2746. 18.46, !- Vertex 3 Y-coordinate {m}
  2747. 0.9, !- Vertex 3 Z-coordinate {m}
  2748. 19.85, !- Vertex 4 X-coordinate {m}
  2749. 18.46, !- Vertex 4 Y-coordinate {m}
  2750. 2.424; !- Vertex 4 Z-coordinate {m}
  2751.  
  2752. FenestrationSurface:Detailed,
  2753. Perimeter_ZN_3_wall_north_Window_3, !- Name
  2754. Window, !- Surface Type
  2755. Window Non-res Fixed, !- Construction Name
  2756. Perimeter_ZN_3_wall_north, !- Building Surface Name
  2757. , !- Outside Boundary Condition Object
  2758. , !- View Factor to Ground
  2759. , !- Shading Control Name
  2760. , !- Frame and Divider Name
  2761. 1, !- Multiplier
  2762. , !- Number of Vertices
  2763. 17.07, !- Vertex 1 X-coordinate {m}
  2764. 18.46, !- Vertex 1 Y-coordinate {m}
  2765. 2.424, !- Vertex 1 Z-coordinate {m}
  2766. 17.07, !- Vertex 2 X-coordinate {m}
  2767. 18.46, !- Vertex 2 Y-coordinate {m}
  2768. 0.9, !- Vertex 2 Z-coordinate {m}
  2769. 15.24, !- Vertex 3 X-coordinate {m}
  2770. 18.46, !- Vertex 3 Y-coordinate {m}
  2771. 0.9, !- Vertex 3 Z-coordinate {m}
  2772. 15.24, !- Vertex 4 X-coordinate {m}
  2773. 18.46, !- Vertex 4 Y-coordinate {m}
  2774. 2.424; !- Vertex 4 Z-coordinate {m}
  2775.  
  2776. FenestrationSurface:Detailed,
  2777. Perimeter_ZN_3_wall_north_Window_4, !- Name
  2778. Window, !- Surface Type
  2779. Window Non-res Fixed, !- Construction Name
  2780. Perimeter_ZN_3_wall_north, !- Building Surface Name
  2781. , !- Outside Boundary Condition Object
  2782. , !- View Factor to Ground
  2783. , !- Shading Control Name
  2784. , !- Frame and Divider Name
  2785. 1, !- Multiplier
  2786. , !- Number of Vertices
  2787. 12.45, !- Vertex 1 X-coordinate {m}
  2788. 18.46, !- Vertex 1 Y-coordinate {m}
  2789. 2.424, !- Vertex 1 Z-coordinate {m}
  2790. 12.45, !- Vertex 2 X-coordinate {m}
  2791. 18.46, !- Vertex 2 Y-coordinate {m}
  2792. 0.9, !- Vertex 2 Z-coordinate {m}
  2793. 10.62, !- Vertex 3 X-coordinate {m}
  2794. 18.46, !- Vertex 3 Y-coordinate {m}
  2795. 0.9, !- Vertex 3 Z-coordinate {m}
  2796. 10.62, !- Vertex 4 X-coordinate {m}
  2797. 18.46, !- Vertex 4 Y-coordinate {m}
  2798. 2.424; !- Vertex 4 Z-coordinate {m}
  2799.  
  2800. FenestrationSurface:Detailed,
  2801. Perimeter_ZN_3_wall_north_Window_5, !- Name
  2802. Window, !- Surface Type
  2803. Window Non-res Fixed, !- Construction Name
  2804. Perimeter_ZN_3_wall_north, !- Building Surface Name
  2805. , !- Outside Boundary Condition Object
  2806. , !- View Factor to Ground
  2807. , !- Shading Control Name
  2808. , !- Frame and Divider Name
  2809. 1, !- Multiplier
  2810. , !- Number of Vertices
  2811. 7.84, !- Vertex 1 X-coordinate {m}
  2812. 18.46, !- Vertex 1 Y-coordinate {m}
  2813. 2.424, !- Vertex 1 Z-coordinate {m}
  2814. 7.84, !- Vertex 2 X-coordinate {m}
  2815. 18.46, !- Vertex 2 Y-coordinate {m}
  2816. 0.9, !- Vertex 2 Z-coordinate {m}
  2817. 6.01, !- Vertex 3 X-coordinate {m}
  2818. 18.46, !- Vertex 3 Y-coordinate {m}
  2819. 0.9, !- Vertex 3 Z-coordinate {m}
  2820. 6.01, !- Vertex 4 X-coordinate {m}
  2821. 18.46, !- Vertex 4 Y-coordinate {m}
  2822. 2.424; !- Vertex 4 Z-coordinate {m}
  2823.  
  2824. FenestrationSurface:Detailed,
  2825. Perimeter_ZN_3_wall_north_Window_6, !- Name
  2826. Window, !- Surface Type
  2827. Window Non-res Fixed, !- Construction Name
  2828. Perimeter_ZN_3_wall_north, !- Building Surface Name
  2829. , !- Outside Boundary Condition Object
  2830. , !- View Factor to Ground
  2831. , !- Shading Control Name
  2832. , !- Frame and Divider Name
  2833. 1, !- Multiplier
  2834. , !- Number of Vertices
  2835. 3.22, !- Vertex 1 X-coordinate {m}
  2836. 18.46, !- Vertex 1 Y-coordinate {m}
  2837. 2.424, !- Vertex 1 Z-coordinate {m}
  2838. 3.22, !- Vertex 2 X-coordinate {m}
  2839. 18.46, !- Vertex 2 Y-coordinate {m}
  2840. 0.9, !- Vertex 2 Z-coordinate {m}
  2841. 1.39, !- Vertex 3 X-coordinate {m}
  2842. 18.46, !- Vertex 3 Y-coordinate {m}
  2843. 0.9, !- Vertex 3 Z-coordinate {m}
  2844. 1.39, !- Vertex 4 X-coordinate {m}
  2845. 18.46, !- Vertex 4 Y-coordinate {m}
  2846. 2.424; !- Vertex 4 Z-coordinate {m}
  2847.  
  2848. FenestrationSurface:Detailed,
  2849. Perimeter_ZN_4_wall_west_Window_1, !- Name
  2850. Window, !- Surface Type
  2851. Window Non-res Fixed, !- Construction Name
  2852. Perimeter_ZN_4_wall_west,!- Building Surface Name
  2853. , !- Outside Boundary Condition Object
  2854. , !- View Factor to Ground
  2855. , !- Shading Control Name
  2856. , !- Frame and Divider Name
  2857. 1, !- Multiplier
  2858. , !- Number of Vertices
  2859. 0, !- Vertex 1 X-coordinate {m}
  2860. 17.07, !- Vertex 1 Y-coordinate {m}
  2861. 2.424, !- Vertex 1 Z-coordinate {m}
  2862. 0, !- Vertex 2 X-coordinate {m}
  2863. 17.07, !- Vertex 2 Y-coordinate {m}
  2864. 0.9, !- Vertex 2 Z-coordinate {m}
  2865. 0, !- Vertex 3 X-coordinate {m}
  2866. 15.24, !- Vertex 3 Y-coordinate {m}
  2867. 0.9, !- Vertex 3 Z-coordinate {m}
  2868. 0, !- Vertex 4 X-coordinate {m}
  2869. 15.24, !- Vertex 4 Y-coordinate {m}
  2870. 2.424; !- Vertex 4 Z-coordinate {m}
  2871.  
  2872. FenestrationSurface:Detailed,
  2873. Perimeter_ZN_4_wall_west_Window_2, !- Name
  2874. Window, !- Surface Type
  2875. Window Non-res Fixed, !- Construction Name
  2876. Perimeter_ZN_4_wall_west,!- Building Surface Name
  2877. , !- Outside Boundary Condition Object
  2878. , !- View Factor to Ground
  2879. , !- Shading Control Name
  2880. , !- Frame and Divider Name
  2881. 1, !- Multiplier
  2882. , !- Number of Vertices
  2883. 0, !- Vertex 1 X-coordinate {m}
  2884. 12.45, !- Vertex 1 Y-coordinate {m}
  2885. 2.424, !- Vertex 1 Z-coordinate {m}
  2886. 0, !- Vertex 2 X-coordinate {m}
  2887. 12.45, !- Vertex 2 Y-coordinate {m}
  2888. 0.9, !- Vertex 2 Z-coordinate {m}
  2889. 0, !- Vertex 3 X-coordinate {m}
  2890. 10.62, !- Vertex 3 Y-coordinate {m}
  2891. 0.9, !- Vertex 3 Z-coordinate {m}
  2892. 0, !- Vertex 4 X-coordinate {m}
  2893. 10.62, !- Vertex 4 Y-coordinate {m}
  2894. 2.424; !- Vertex 4 Z-coordinate {m}
  2895.  
  2896. FenestrationSurface:Detailed,
  2897. Perimeter_ZN_4_wall_west_Window_3, !- Name
  2898. Window, !- Surface Type
  2899. Window Non-res Fixed, !- Construction Name
  2900. Perimeter_ZN_4_wall_west,!- Building Surface Name
  2901. , !- Outside Boundary Condition Object
  2902. , !- View Factor to Ground
  2903. , !- Shading Control Name
  2904. , !- Frame and Divider Name
  2905. 1, !- Multiplier
  2906. , !- Number of Vertices
  2907. 0, !- Vertex 1 X-coordinate {m}
  2908. 7.84, !- Vertex 1 Y-coordinate {m}
  2909. 2.424, !- Vertex 1 Z-coordinate {m}
  2910. 0, !- Vertex 2 X-coordinate {m}
  2911. 7.84, !- Vertex 2 Y-coordinate {m}
  2912. 0.9, !- Vertex 2 Z-coordinate {m}
  2913. 0, !- Vertex 3 X-coordinate {m}
  2914. 6.01, !- Vertex 3 Y-coordinate {m}
  2915. 0.9, !- Vertex 3 Z-coordinate {m}
  2916. 0, !- Vertex 4 X-coordinate {m}
  2917. 6.01, !- Vertex 4 Y-coordinate {m}
  2918. 2.424; !- Vertex 4 Z-coordinate {m}
  2919.  
  2920. FenestrationSurface:Detailed,
  2921. Perimeter_ZN_4_wall_west_Window_4, !- Name
  2922. Window, !- Surface Type
  2923. Window Non-res Fixed, !- Construction Name
  2924. Perimeter_ZN_4_wall_west,!- Building Surface Name
  2925. , !- Outside Boundary Condition Object
  2926. , !- View Factor to Ground
  2927. , !- Shading Control Name
  2928. , !- Frame and Divider Name
  2929. 1, !- Multiplier
  2930. , !- Number of Vertices
  2931. 0, !- Vertex 1 X-coordinate {m}
  2932. 3.22, !- Vertex 1 Y-coordinate {m}
  2933. 2.424, !- Vertex 1 Z-coordinate {m}
  2934. 0, !- Vertex 2 X-coordinate {m}
  2935. 3.22, !- Vertex 2 Y-coordinate {m}
  2936. 0.9, !- Vertex 2 Z-coordinate {m}
  2937. 0, !- Vertex 3 X-coordinate {m}
  2938. 1.39, !- Vertex 3 Y-coordinate {m}
  2939. 0.9, !- Vertex 3 Z-coordinate {m}
  2940. 0, !- Vertex 4 X-coordinate {m}
  2941. 1.39, !- Vertex 4 Y-coordinate {m}
  2942. 2.424; !- Vertex 4 Z-coordinate {m}
  2943.  
  2944.  
  2945. !- =========== ALL OBJECTS IN CLASS: INTERNALMASS ===========
  2946.  
  2947. InternalMass,
  2948. Core_ZN Internal Mass, !- Name
  2949. InteriorFurnishings, !- Construction Name
  2950. Core_ZN Thermal Zone, !- Zone Name
  2951. 299.3148; !- Surface Area {m2}
  2952.  
  2953. InternalMass,
  2954. Perimeter_ZN_1 Internal Mass, !- Name
  2955. InteriorFurnishings, !- Construction Name
  2956. Perimeter_ZN_1 Thermal Zone, !- Zone Name
  2957. 226.9; !- Surface Area {m2}
  2958.  
  2959. InternalMass,
  2960. Perimeter_ZN_2 Internal Mass, !- Name
  2961. InteriorFurnishings, !- Construction Name
  2962. Perimeter_ZN_2 Thermal Zone, !- Zone Name
  2963. 134.6; !- Surface Area {m2}
  2964.  
  2965. InternalMass,
  2966. Perimeter_ZN_3 Internal Mass, !- Name
  2967. InteriorFurnishings, !- Construction Name
  2968. Perimeter_ZN_3 Thermal Zone, !- Zone Name
  2969. 226.9; !- Surface Area {m2}
  2970.  
  2971. InternalMass,
  2972. Perimeter_ZN_4 Internal Mass, !- Name
  2973. InteriorFurnishings, !- Construction Name
  2974. Perimeter_ZN_4 Thermal Zone, !- Zone Name
  2975. 134.6; !- Surface Area {m2}
  2976.  
  2977.  
  2978. !- =========== ALL OBJECTS IN CLASS: PEOPLE ===========
  2979.  
  2980. People,
  2981. Core_ZN People, !- Name
  2982. Core_ZN Thermal Zone, !- Zone or ZoneList Name
  2983. BLDG_OCC_SCH, !- Number of People Schedule Name
  2984. Area/Person, !- Number of People Calculation Method
  2985. , !- Number of People
  2986. , !- People per Zone Floor Area {person/m2}
  2987. 18.58, !- Zone Floor Area per Person {m2/person}
  2988. 0.3, !- Fraction Radiant
  2989. , !- Sensible Heat Fraction
  2990. ACTIVITY_SCH, !- Activity Level Schedule Name
  2991. , !- Carbon Dioxide Generation Rate {m3/s-W}
  2992. No, !- Enable ASHRAE 55 Comfort Warnings
  2993. ZoneAveraged, !- Mean Radiant Temperature Calculation Type
  2994. , !- Surface Name/Angle Factor List Name
  2995. WORK_EFF_SCH, !- Work Efficiency Schedule Name
  2996. , !- Clothing Insulation Calculation Method
  2997. , !- Clothing Insulation Calculation Method Schedule Name
  2998. CLOTHING_SCH, !- Clothing Insulation Schedule Name
  2999. AIR_VELO_SCH, !- Air Velocity Schedule Name
  3000. FANGER; !- Thermal Comfort Model 1 Type
  3001.  
  3002. People,
  3003. Perimeter_ZN_1 People, !- Name
  3004. Perimeter_ZN_1 Thermal Zone, !- Zone or ZoneList Name
  3005. BLDG_OCC_SCH, !- Number of People Schedule Name
  3006. Area/Person, !- Number of People Calculation Method
  3007. , !- Number of People
  3008. , !- People per Zone Floor Area {person/m2}
  3009. 18.58, !- Zone Floor Area per Person {m2/person}
  3010. 0.3, !- Fraction Radiant
  3011. , !- Sensible Heat Fraction
  3012. ACTIVITY_SCH, !- Activity Level Schedule Name
  3013. , !- Carbon Dioxide Generation Rate {m3/s-W}
  3014. No, !- Enable ASHRAE 55 Comfort Warnings
  3015. ZoneAveraged, !- Mean Radiant Temperature Calculation Type
  3016. , !- Surface Name/Angle Factor List Name
  3017. WORK_EFF_SCH, !- Work Efficiency Schedule Name
  3018. , !- Clothing Insulation Calculation Method
  3019. , !- Clothing Insulation Calculation Method Schedule Name
  3020. CLOTHING_SCH, !- Clothing Insulation Schedule Name
  3021. AIR_VELO_SCH, !- Air Velocity Schedule Name
  3022. FANGER; !- Thermal Comfort Model 1 Type
  3023.  
  3024. People,
  3025. Perimeter_ZN_2 People, !- Name
  3026. Perimeter_ZN_2 Thermal Zone, !- Zone or ZoneList Name
  3027. BLDG_OCC_SCH, !- Number of People Schedule Name
  3028. Area/Person, !- Number of People Calculation Method
  3029. , !- Number of People
  3030. , !- People per Zone Floor Area {person/m2}
  3031. 18.58, !- Zone Floor Area per Person {m2/person}
  3032. 0.3, !- Fraction Radiant
  3033. , !- Sensible Heat Fraction
  3034. ACTIVITY_SCH, !- Activity Level Schedule Name
  3035. , !- Carbon Dioxide Generation Rate {m3/s-W}
  3036. No, !- Enable ASHRAE 55 Comfort Warnings
  3037. ZoneAveraged, !- Mean Radiant Temperature Calculation Type
  3038. , !- Surface Name/Angle Factor List Name
  3039. WORK_EFF_SCH, !- Work Efficiency Schedule Name
  3040. , !- Clothing Insulation Calculation Method
  3041. , !- Clothing Insulation Calculation Method Schedule Name
  3042. CLOTHING_SCH, !- Clothing Insulation Schedule Name
  3043. AIR_VELO_SCH, !- Air Velocity Schedule Name
  3044. FANGER; !- Thermal Comfort Model 1 Type
  3045.  
  3046. People,
  3047. Perimeter_ZN_3 People, !- Name
  3048. Perimeter_ZN_3 Thermal Zone, !- Zone or ZoneList Name
  3049. BLDG_OCC_SCH, !- Number of People Schedule Name
  3050. Area/Person, !- Number of People Calculation Method
  3051. , !- Number of People
  3052. , !- People per Zone Floor Area {person/m2}
  3053. 18.58, !- Zone Floor Area per Person {m2/person}
  3054. 0.3, !- Fraction Radiant
  3055. , !- Sensible Heat Fraction
  3056. ACTIVITY_SCH, !- Activity Level Schedule Name
  3057. , !- Carbon Dioxide Generation Rate {m3/s-W}
  3058. No, !- Enable ASHRAE 55 Comfort Warnings
  3059. ZoneAveraged, !- Mean Radiant Temperature Calculation Type
  3060. , !- Surface Name/Angle Factor List Name
  3061. WORK_EFF_SCH, !- Work Efficiency Schedule Name
  3062. , !- Clothing Insulation Calculation Method
  3063. , !- Clothing Insulation Calculation Method Schedule Name
  3064. CLOTHING_SCH, !- Clothing Insulation Schedule Name
  3065. AIR_VELO_SCH, !- Air Velocity Schedule Name
  3066. FANGER; !- Thermal Comfort Model 1 Type
  3067.  
  3068. People,
  3069. Perimeter_ZN_4 People, !- Name
  3070. Perimeter_ZN_4 Thermal Zone, !- Zone or ZoneList Name
  3071. BLDG_OCC_SCH, !- Number of People Schedule Name
  3072. Area/Person, !- Number of People Calculation Method
  3073. , !- Number of People
  3074. , !- People per Zone Floor Area {person/m2}
  3075. 18.58, !- Zone Floor Area per Person {m2/person}
  3076. 0.3, !- Fraction Radiant
  3077. , !- Sensible Heat Fraction
  3078. ACTIVITY_SCH, !- Activity Level Schedule Name
  3079. , !- Carbon Dioxide Generation Rate {m3/s-W}
  3080. No, !- Enable ASHRAE 55 Comfort Warnings
  3081. ZoneAveraged, !- Mean Radiant Temperature Calculation Type
  3082. , !- Surface Name/Angle Factor List Name
  3083. WORK_EFF_SCH, !- Work Efficiency Schedule Name
  3084. , !- Clothing Insulation Calculation Method
  3085. , !- Clothing Insulation Calculation Method Schedule Name
  3086. CLOTHING_SCH, !- Clothing Insulation Schedule Name
  3087. AIR_VELO_SCH, !- Air Velocity Schedule Name
  3088. FANGER; !- Thermal Comfort Model 1 Type
  3089.  
  3090.  
  3091. !- =========== ALL OBJECTS IN CLASS: LIGHTS ===========
  3092.  
  3093. Lights,
  3094. Core_ZN_Lights, !- Name
  3095. Core_ZN Thermal Zone, !- Zone or ZoneList Name
  3096. BLDG_LIGHT_SCH, !- Schedule Name
  3097. Watts/Area, !- Design Level Calculation Method
  3098. , !- Lighting Level {W}
  3099. 10.76, !- Watts per Zone Floor Area {W/m2}
  3100. , !- Watts per Person {W/person}
  3101. 0, !- Return Air Fraction
  3102. 0.7, !- Fraction Radiant
  3103. 0.2, !- Fraction Visible
  3104. 1, !- Fraction Replaceable
  3105. General, !- End-Use Subcategory
  3106. No; !- Return Air Fraction Calculated from Plenum Temperature
  3107.  
  3108. Lights,
  3109. Perimeter_ZN_1_Lights, !- Name
  3110. Perimeter_ZN_1 Thermal Zone, !- Zone or ZoneList Name
  3111. BLDG_LIGHT_SCH, !- Schedule Name
  3112. Watts/Area, !- Design Level Calculation Method
  3113. , !- Lighting Level {W}
  3114. 10.76, !- Watts per Zone Floor Area {W/m2}
  3115. , !- Watts per Person {W/person}
  3116. 0, !- Return Air Fraction
  3117. 0.7, !- Fraction Radiant
  3118. 0.2, !- Fraction Visible
  3119. 1, !- Fraction Replaceable
  3120. General, !- End-Use Subcategory
  3121. No; !- Return Air Fraction Calculated from Plenum Temperature
  3122.  
  3123. Lights,
  3124. Perimeter_ZN_2_Lights, !- Name
  3125. Perimeter_ZN_2 Thermal Zone, !- Zone or ZoneList Name
  3126. BLDG_LIGHT_SCH, !- Schedule Name
  3127. Watts/Area, !- Design Level Calculation Method
  3128. , !- Lighting Level {W}
  3129. 10.76, !- Watts per Zone Floor Area {W/m2}
  3130. , !- Watts per Person {W/person}
  3131. 0, !- Return Air Fraction
  3132. 0.7, !- Fraction Radiant
  3133. 0.2, !- Fraction Visible
  3134. 1, !- Fraction Replaceable
  3135. General, !- End-Use Subcategory
  3136. No; !- Return Air Fraction Calculated from Plenum Temperature
  3137.  
  3138. Lights,
  3139. Perimeter_ZN_3_Lights, !- Name
  3140. Perimeter_ZN_3 Thermal Zone, !- Zone or ZoneList Name
  3141. BLDG_LIGHT_SCH, !- Schedule Name
  3142. Watts/Area, !- Design Level Calculation Method
  3143. , !- Lighting Level {W}
  3144. 10.76, !- Watts per Zone Floor Area {W/m2}
  3145. , !- Watts per Person {W/person}
  3146. 0, !- Return Air Fraction
  3147. 0.7, !- Fraction Radiant
  3148. 0.2, !- Fraction Visible
  3149. 1, !- Fraction Replaceable
  3150. General, !- End-Use Subcategory
  3151. No; !- Return Air Fraction Calculated from Plenum Temperature
  3152.  
  3153. Lights,
  3154. Perimeter_ZN_4_Lights, !- Name
  3155. Perimeter_ZN_4 Thermal Zone, !- Zone or ZoneList Name
  3156. BLDG_LIGHT_SCH, !- Schedule Name
  3157. Watts/Area, !- Design Level Calculation Method
  3158. , !- Lighting Level {W}
  3159. 10.76, !- Watts per Zone Floor Area {W/m2}
  3160. , !- Watts per Person {W/person}
  3161. 0, !- Return Air Fraction
  3162. 0.7, !- Fraction Radiant
  3163. 0.2, !- Fraction Visible
  3164. 1, !- Fraction Replaceable
  3165. General, !- End-Use Subcategory
  3166. No; !- Return Air Fraction Calculated from Plenum Temperature
  3167.  
  3168.  
  3169. !- =========== ALL OBJECTS IN CLASS: ELECTRICEQUIPMENT ===========
  3170.  
  3171. ElectricEquipment,
  3172. Core_ZN_MiscPlug_Equip, !- Name
  3173. Core_ZN Thermal Zone, !- Zone or ZoneList Name
  3174. BLDG_EQUIP_SCH, !- Schedule Name
  3175. Watts/Area, !- Design Level Calculation Method
  3176. , !- Design Level {W}
  3177. 10.76, !- Watts per Zone Floor Area {W/m2}
  3178. , !- Watts per Person {W/person}
  3179. 0, !- Fraction Latent
  3180. 0.5, !- Fraction Radiant
  3181. 0, !- Fraction Lost
  3182. MiscPlug; !- End-Use Subcategory
  3183.  
  3184. ElectricEquipment,
  3185. Perimeter_ZN_1_MiscPlug_Equip, !- Name
  3186. Perimeter_ZN_1 Thermal Zone, !- Zone or ZoneList Name
  3187. BLDG_EQUIP_SCH, !- Schedule Name
  3188. Watts/Area, !- Design Level Calculation Method
  3189. , !- Design Level {W}
  3190. 10.76, !- Watts per Zone Floor Area {W/m2}
  3191. , !- Watts per Person {W/person}
  3192. 0, !- Fraction Latent
  3193. 0.5, !- Fraction Radiant
  3194. 0, !- Fraction Lost
  3195. MiscPlug; !- End-Use Subcategory
  3196.  
  3197. ElectricEquipment,
  3198. Perimeter_ZN_2_MiscPlug_Equip, !- Name
  3199. Perimeter_ZN_2 Thermal Zone, !- Zone or ZoneList Name
  3200. BLDG_EQUIP_SCH, !- Schedule Name
  3201. Watts/Area, !- Design Level Calculation Method
  3202. , !- Design Level {W}
  3203. 10.76, !- Watts per Zone Floor Area {W/m2}
  3204. , !- Watts per Person {W/person}
  3205. 0, !- Fraction Latent
  3206. 0.5, !- Fraction Radiant
  3207. 0, !- Fraction Lost
  3208. MiscPlug; !- End-Use Subcategory
  3209.  
  3210. ElectricEquipment,
  3211. Perimeter_ZN_3_MiscPlug_Equip, !- Name
  3212. Perimeter_ZN_3 Thermal Zone, !- Zone or ZoneList Name
  3213. BLDG_EQUIP_SCH, !- Schedule Name
  3214. Watts/Area, !- Design Level Calculation Method
  3215. , !- Design Level {W}
  3216. 10.76, !- Watts per Zone Floor Area {W/m2}
  3217. , !- Watts per Person {W/person}
  3218. 0, !- Fraction Latent
  3219. 0.5, !- Fraction Radiant
  3220. 0, !- Fraction Lost
  3221. MiscPlug; !- End-Use Subcategory
  3222.  
  3223. ElectricEquipment,
  3224. Perimeter_ZN_4_MiscPlug_Equip, !- Name
  3225. Perimeter_ZN_4 Thermal Zone, !- Zone or ZoneList Name
  3226. BLDG_EQUIP_SCH, !- Schedule Name
  3227. Watts/Area, !- Design Level Calculation Method
  3228. , !- Design Level {W}
  3229. 10.76, !- Watts per Zone Floor Area {W/m2}
  3230. , !- Watts per Person {W/person}
  3231. 0, !- Fraction Latent
  3232. 0.5, !- Fraction Radiant
  3233. 0, !- Fraction Lost
  3234. MiscPlug; !- End-Use Subcategory
  3235.  
  3236.  
  3237. !- =========== ALL OBJECTS IN CLASS: ZONEINFILTRATION:DESIGNFLOWRATE ===========
  3238.  
  3239. ZoneInfiltration:DesignFlowRate,
  3240. Attic_Infiltration, !- Name
  3241. Attic Thermal Zone, !- Zone or ZoneList Name
  3242. ALWAYS_ON, !- Schedule Name
  3243. AirChanges/Hour, !- Design Flow Rate Calculation Method
  3244. , !- Design Flow Rate {m3/s}
  3245. , !- Flow per Zone Floor Area {m3/s-m2}
  3246. , !- Flow per Exterior Surface Area {m3/s-m2}
  3247. 1, !- Air Changes per Hour {1/hr}
  3248. 1, !- Constant Term Coefficient
  3249. 0, !- Temperature Term Coefficient
  3250. 0, !- Velocity Term Coefficient
  3251. 0; !- Velocity Squared Term Coefficient
  3252.  
  3253. ZoneInfiltration:DesignFlowRate,
  3254. Core_ZN_Infiltration, !- Name
  3255. Core_ZN Thermal Zone, !- Zone or ZoneList Name
  3256. INFIL_QUARTER_ON_SCH, !- Schedule Name
  3257. AirChanges/Hour, !- Design Flow Rate Calculation Method
  3258. , !- Design Flow Rate {m3/s}
  3259. , !- Flow per Zone Floor Area {m3/s-m2}
  3260. , !- Flow per Exterior Surface Area {m3/s-m2}
  3261. 0.36, !- Air Changes per Hour {1/hr}
  3262. 1, !- Constant Term Coefficient
  3263. 0, !- Temperature Term Coefficient
  3264. 0, !- Velocity Term Coefficient
  3265. 0; !- Velocity Squared Term Coefficient
  3266.  
  3267. ZoneInfiltration:DesignFlowRate,
  3268. Perimeter_ZN_1_Infiltration, !- Name
  3269. Perimeter_ZN_1 Thermal Zone, !- Zone or ZoneList Name
  3270. INFIL_QUARTER_ON_SCH, !- Schedule Name
  3271. Flow/ExteriorArea, !- Design Flow Rate Calculation Method
  3272. , !- Design Flow Rate {m3/s}
  3273. , !- Flow per Zone Floor Area {m3/s-m2}
  3274. 0.000302, !- Flow per Exterior Surface Area {m3/s-m2}
  3275. , !- Air Changes per Hour {1/hr}
  3276. 1, !- Constant Term Coefficient
  3277. 0, !- Temperature Term Coefficient
  3278. 0, !- Velocity Term Coefficient
  3279. 0; !- Velocity Squared Term Coefficient
  3280.  
  3281. ZoneInfiltration:DesignFlowRate,
  3282. Perimeter_ZN_2_Infiltration, !- Name
  3283. Perimeter_ZN_2 Thermal Zone, !- Zone or ZoneList Name
  3284. INFIL_QUARTER_ON_SCH, !- Schedule Name
  3285. Flow/ExteriorArea, !- Design Flow Rate Calculation Method
  3286. , !- Design Flow Rate {m3/s}
  3287. , !- Flow per Zone Floor Area {m3/s-m2}
  3288. 0.000302, !- Flow per Exterior Surface Area {m3/s-m2}
  3289. , !- Air Changes per Hour {1/hr}
  3290. 1, !- Constant Term Coefficient
  3291. 0, !- Temperature Term Coefficient
  3292. 0, !- Velocity Term Coefficient
  3293. 0; !- Velocity Squared Term Coefficient
  3294.  
  3295. ZoneInfiltration:DesignFlowRate,
  3296. Perimeter_ZN_3_Infiltration, !- Name
  3297. Perimeter_ZN_3 Thermal Zone, !- Zone or ZoneList Name
  3298. INFIL_QUARTER_ON_SCH, !- Schedule Name
  3299. Flow/ExteriorArea, !- Design Flow Rate Calculation Method
  3300. , !- Design Flow Rate {m3/s}
  3301. , !- Flow per Zone Floor Area {m3/s-m2}
  3302. 0.000302, !- Flow per Exterior Surface Area {m3/s-m2}
  3303. , !- Air Changes per Hour {1/hr}
  3304. 1, !- Constant Term Coefficient
  3305. 0, !- Temperature Term Coefficient
  3306. 0, !- Velocity Term Coefficient
  3307. 0; !- Velocity Squared Term Coefficient
  3308.  
  3309. ZoneInfiltration:DesignFlowRate,
  3310. Perimeter_ZN_4_Infiltration, !- Name
  3311. Perimeter_ZN_4 Thermal Zone, !- Zone or ZoneList Name
  3312. INFIL_QUARTER_ON_SCH, !- Schedule Name
  3313. Flow/ExteriorArea, !- Design Flow Rate Calculation Method
  3314. , !- Design Flow Rate {m3/s}
  3315. , !- Flow per Zone Floor Area {m3/s-m2}
  3316. 0.000302, !- Flow per Exterior Surface Area {m3/s-m2}
  3317. , !- Air Changes per Hour {1/hr}
  3318. 1, !- Constant Term Coefficient
  3319. 0, !- Temperature Term Coefficient
  3320. 0, !- Velocity Term Coefficient
  3321. 0; !- Velocity Squared Term Coefficient
  3322.  
  3323.  
  3324. !- =========== ALL OBJECTS IN CLASS: DESIGNSPECIFICATION:OUTDOORAIR ===========
  3325.  
  3326. DesignSpecification:OutdoorAir,
  3327. SZ DSOA Core_ZN, !- Name
  3328. Sum, !- Outdoor Air Method
  3329. 0.01, !- Outdoor Air Flow per Person {m3/s-person}
  3330. 0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2}
  3331. 0, !- Outdoor Air Flow per Zone {m3/s}
  3332. 0; !- Outdoor Air Flow Air Changes per Hour {1/hr}
  3333.  
  3334. DesignSpecification:OutdoorAir,
  3335. SZ DSOA Perimeter_ZN_1, !- Name
  3336. Sum, !- Outdoor Air Method
  3337. 0.01, !- Outdoor Air Flow per Person {m3/s-person}
  3338. 0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2}
  3339. 0, !- Outdoor Air Flow per Zone {m3/s}
  3340. 0; !- Outdoor Air Flow Air Changes per Hour {1/hr}
  3341.  
  3342. DesignSpecification:OutdoorAir,
  3343. SZ DSOA Perimeter_ZN_2, !- Name
  3344. Sum, !- Outdoor Air Method
  3345. 0.01, !- Outdoor Air Flow per Person {m3/s-person}
  3346. 0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2}
  3347. 0, !- Outdoor Air Flow per Zone {m3/s}
  3348. 0; !- Outdoor Air Flow Air Changes per Hour {1/hr}
  3349.  
  3350. DesignSpecification:OutdoorAir,
  3351. SZ DSOA Perimeter_ZN_3, !- Name
  3352. Sum, !- Outdoor Air Method
  3353. 0.01, !- Outdoor Air Flow per Person {m3/s-person}
  3354. 0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2}
  3355. 0, !- Outdoor Air Flow per Zone {m3/s}
  3356. 0; !- Outdoor Air Flow Air Changes per Hour {1/hr}
  3357.  
  3358. DesignSpecification:OutdoorAir,
  3359. SZ DSOA Perimeter_ZN_4, !- Name
  3360. Sum, !- Outdoor Air Method
  3361. 0.01, !- Outdoor Air Flow per Person {m3/s-person}
  3362. 0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2}
  3363. 0, !- Outdoor Air Flow per Zone {m3/s}
  3364. 0; !- Outdoor Air Flow Air Changes per Hour {1/hr}
  3365.  
  3366.  
  3367. !- =========== ALL OBJECTS IN CLASS: DESIGNSPECIFICATION:ZONEAIRDISTRIBUTION ===========
  3368.  
  3369. DesignSpecification:ZoneAirDistribution,
  3370. Core_ZN Thermal Zone Design Spec Zone Air Dist, !- Name
  3371. 1, !- Zone Air Distribution Effectiveness in Cooling Mode {dimensionless}
  3372. 1; !- Zone Air Distribution Effectiveness in Heating Mode {dimensionless}
  3373.  
  3374. DesignSpecification:ZoneAirDistribution,
  3375. Perimeter_ZN_1 Thermal Zone Design Spec Zone Air Dist, !- Name
  3376. 1, !- Zone Air Distribution Effectiveness in Cooling Mode {dimensionless}
  3377. 1; !- Zone Air Distribution Effectiveness in Heating Mode {dimensionless}
  3378.  
  3379. DesignSpecification:ZoneAirDistribution,
  3380. Perimeter_ZN_2 Thermal Zone Design Spec Zone Air Dist, !- Name
  3381. 1, !- Zone Air Distribution Effectiveness in Cooling Mode {dimensionless}
  3382. 1; !- Zone Air Distribution Effectiveness in Heating Mode {dimensionless}
  3383.  
  3384. DesignSpecification:ZoneAirDistribution,
  3385. Perimeter_ZN_3 Thermal Zone Design Spec Zone Air Dist, !- Name
  3386. 1, !- Zone Air Distribution Effectiveness in Cooling Mode {dimensionless}
  3387. 1; !- Zone Air Distribution Effectiveness in Heating Mode {dimensionless}
  3388.  
  3389. DesignSpecification:ZoneAirDistribution,
  3390. Perimeter_ZN_4 Thermal Zone Design Spec Zone Air Dist, !- Name
  3391. 1, !- Zone Air Distribution Effectiveness in Cooling Mode {dimensionless}
  3392. 1; !- Zone Air Distribution Effectiveness in Heating Mode {dimensionless}
  3393.  
  3394.  
  3395. !- =========== ALL OBJECTS IN CLASS: SIZING:PARAMETERS ===========
  3396.  
  3397. Sizing:Parameters,
  3398. 1.2, !- Heating Sizing Factor
  3399. 1.2, !- Cooling Sizing Factor
  3400. 6; !- Timesteps in Averaging Window
  3401.  
  3402.  
  3403. !- =========== ALL OBJECTS IN CLASS: SIZING:ZONE ===========
  3404.  
  3405. Sizing:Zone,
  3406. Core_ZN Thermal Zone, !- Zone or ZoneList Name
  3407. SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method
  3408. 14, !- Zone Cooling Design Supply Air Temperature {C}
  3409. 11.11, !- Zone Cooling Design Supply Air Temperature Difference {deltaC}
  3410. SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method
  3411. 40, !- Zone Heating Design Supply Air Temperature {C}
  3412. 11.11, !- Zone Heating Design Supply Air Temperature Difference {deltaC}
  3413. 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir}
  3414. 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir}
  3415. SZ DSOA Core_ZN, !- Design Specification Outdoor Air Object Name
  3416. , !- Zone Heating Sizing Factor
  3417. , !- Zone Cooling Sizing Factor
  3418. DesignDay, !- Cooling Design Air Flow Method
  3419. 0, !- Cooling Design Air Flow Rate {m3/s}
  3420. 0.000762, !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2}
  3421. 0, !- Cooling Minimum Air Flow {m3/s}
  3422. 0, !- Cooling Minimum Air Flow Fraction
  3423. DesignDay, !- Heating Design Air Flow Method
  3424. 0, !- Heating Design Air Flow Rate {m3/s}
  3425. 0.002032, !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2}
  3426. 0.1415762, !- Heating Maximum Air Flow {m3/s}
  3427. 0.3, !- Heating Maximum Air Flow Fraction
  3428. Core_ZN Thermal Zone Design Spec Zone Air Dist, !- Design Specification Zone Air Distribution Object Name
  3429. No; !- Account for Dedicated Outdoor Air System
  3430.  
  3431. Sizing:Zone,
  3432. Perimeter_ZN_1 Thermal Zone, !- Zone or ZoneList Name
  3433. SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method
  3434. 14, !- Zone Cooling Design Supply Air Temperature {C}
  3435. 11.11, !- Zone Cooling Design Supply Air Temperature Difference {deltaC}
  3436. SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method
  3437. 40, !- Zone Heating Design Supply Air Temperature {C}
  3438. 11.11, !- Zone Heating Design Supply Air Temperature Difference {deltaC}
  3439. 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir}
  3440. 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir}
  3441. SZ DSOA Perimeter_ZN_1, !- Design Specification Outdoor Air Object Name
  3442. , !- Zone Heating Sizing Factor
  3443. , !- Zone Cooling Sizing Factor
  3444. DesignDay, !- Cooling Design Air Flow Method
  3445. 0, !- Cooling Design Air Flow Rate {m3/s}
  3446. 0.000762, !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2}
  3447. 0, !- Cooling Minimum Air Flow {m3/s}
  3448. 0, !- Cooling Minimum Air Flow Fraction
  3449. DesignDay, !- Heating Design Air Flow Method
  3450. 0, !- Heating Design Air Flow Rate {m3/s}
  3451. 0.002032, !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2}
  3452. 0.1415762, !- Heating Maximum Air Flow {m3/s}
  3453. 0.3, !- Heating Maximum Air Flow Fraction
  3454. Perimeter_ZN_1 Thermal Zone Design Spec Zone Air Dist, !- Design Specification Zone Air Distribution Object Name
  3455. No; !- Account for Dedicated Outdoor Air System
  3456.  
  3457. Sizing:Zone,
  3458. Perimeter_ZN_2 Thermal Zone, !- Zone or ZoneList Name
  3459. SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method
  3460. 14, !- Zone Cooling Design Supply Air Temperature {C}
  3461. 11.11, !- Zone Cooling Design Supply Air Temperature Difference {deltaC}
  3462. SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method
  3463. 40, !- Zone Heating Design Supply Air Temperature {C}
  3464. 11.11, !- Zone Heating Design Supply Air Temperature Difference {deltaC}
  3465. 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir}
  3466. 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir}
  3467. SZ DSOA Perimeter_ZN_2, !- Design Specification Outdoor Air Object Name
  3468. , !- Zone Heating Sizing Factor
  3469. , !- Zone Cooling Sizing Factor
  3470. DesignDay, !- Cooling Design Air Flow Method
  3471. 0, !- Cooling Design Air Flow Rate {m3/s}
  3472. 0.000762, !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2}
  3473. 0, !- Cooling Minimum Air Flow {m3/s}
  3474. 0, !- Cooling Minimum Air Flow Fraction
  3475. DesignDay, !- Heating Design Air Flow Method
  3476. 0, !- Heating Design Air Flow Rate {m3/s}
  3477. 0.002032, !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2}
  3478. 0.1415762, !- Heating Maximum Air Flow {m3/s}
  3479. 0.3, !- Heating Maximum Air Flow Fraction
  3480. Perimeter_ZN_2 Thermal Zone Design Spec Zone Air Dist, !- Design Specification Zone Air Distribution Object Name
  3481. No; !- Account for Dedicated Outdoor Air System
  3482.  
  3483. Sizing:Zone,
  3484. Perimeter_ZN_3 Thermal Zone, !- Zone or ZoneList Name
  3485. SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method
  3486. 14, !- Zone Cooling Design Supply Air Temperature {C}
  3487. 11.11, !- Zone Cooling Design Supply Air Temperature Difference {deltaC}
  3488. SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method
  3489. 40, !- Zone Heating Design Supply Air Temperature {C}
  3490. 11.11, !- Zone Heating Design Supply Air Temperature Difference {deltaC}
  3491. 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir}
  3492. 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir}
  3493. SZ DSOA Perimeter_ZN_3, !- Design Specification Outdoor Air Object Name
  3494. , !- Zone Heating Sizing Factor
  3495. , !- Zone Cooling Sizing Factor
  3496. DesignDay, !- Cooling Design Air Flow Method
  3497. 0, !- Cooling Design Air Flow Rate {m3/s}
  3498. 0.000762, !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2}
  3499. 0, !- Cooling Minimum Air Flow {m3/s}
  3500. 0, !- Cooling Minimum Air Flow Fraction
  3501. DesignDay, !- Heating Design Air Flow Method
  3502. 0, !- Heating Design Air Flow Rate {m3/s}
  3503. 0.002032, !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2}
  3504. 0.1415762, !- Heating Maximum Air Flow {m3/s}
  3505. 0.3, !- Heating Maximum Air Flow Fraction
  3506. Perimeter_ZN_3 Thermal Zone Design Spec Zone Air Dist, !- Design Specification Zone Air Distribution Object Name
  3507. No; !- Account for Dedicated Outdoor Air System
  3508.  
  3509. Sizing:Zone,
  3510. Perimeter_ZN_4 Thermal Zone, !- Zone or ZoneList Name
  3511. SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method
  3512. 14, !- Zone Cooling Design Supply Air Temperature {C}
  3513. 11.11, !- Zone Cooling Design Supply Air Temperature Difference {deltaC}
  3514. SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method
  3515. 40, !- Zone Heating Design Supply Air Temperature {C}
  3516. 11.11, !- Zone Heating Design Supply Air Temperature Difference {deltaC}
  3517. 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir}
  3518. 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir}
  3519. SZ DSOA Perimeter_ZN_4, !- Design Specification Outdoor Air Object Name
  3520. , !- Zone Heating Sizing Factor
  3521. , !- Zone Cooling Sizing Factor
  3522. DesignDay, !- Cooling Design Air Flow Method
  3523. 0, !- Cooling Design Air Flow Rate {m3/s}
  3524. 0.000762, !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2}
  3525. 0, !- Cooling Minimum Air Flow {m3/s}
  3526. 0, !- Cooling Minimum Air Flow Fraction
  3527. DesignDay, !- Heating Design Air Flow Method
  3528. 0, !- Heating Design Air Flow Rate {m3/s}
  3529. 0.002032, !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2}
  3530. 0.1415762, !- Heating Maximum Air Flow {m3/s}
  3531. 0.3, !- Heating Maximum Air Flow Fraction
  3532. Perimeter_ZN_4 Thermal Zone Design Spec Zone Air Dist, !- Design Specification Zone Air Distribution Object Name
  3533. No; !- Account for Dedicated Outdoor Air System
  3534.  
  3535.  
  3536. !- =========== ALL OBJECTS IN CLASS: SIZING:SYSTEM ===========
  3537.  
  3538. Sizing:System,
  3539. VAV with Reheat, !- AirLoop Name
  3540. Sensible, !- Type of Load to Size On
  3541. Autosize, !- Design Outdoor Air Flow Rate {m3/s}
  3542. 0.3, !- Central Heating Maximum System Air Flow Ratio
  3543. 7, !- Preheat Design Temperature {C}
  3544. 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir}
  3545. 12.8, !- Precool Design Temperature {C}
  3546. 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir}
  3547. 12.8, !- Central Cooling Design Supply Air Temperature {C}
  3548. 12.8, !- Central Heating Design Supply Air Temperature {C}
  3549. NonCoincident, !- Type of Zone Sum to Use
  3550. Yes, !- 100% Outdoor Air in Cooling
  3551. Yes, !- 100% Outdoor Air in Heating
  3552. 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir}
  3553. 0.008, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir}
  3554. DesignDay, !- Cooling Supply Air Flow Rate Method
  3555. 0, !- Cooling Supply Air Flow Rate {m3/s}
  3556. 0.0099676501, !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2}
  3557. 1, !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate
  3558. 3.9475456e-005, !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W}
  3559. DesignDay, !- Heating Supply Air Flow Rate Method
  3560. 0, !- Heating Supply Air Flow Rate {m3/s}
  3561. 0.0099676501, !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2}
  3562. 1, !- Heating Fraction of Autosized Heating Supply Air Flow Rate
  3563. 1, !- Heating Fraction of Autosized Cooling Supply Air Flow Rate
  3564. 3.1588213e-005, !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W}
  3565. ZoneSum, !- System Outdoor Air Method
  3566. 1, !- Zone Maximum Outdoor Air Fraction {dimensionless}
  3567. CoolingDesignCapacity, !- Cooling Design Capacity Method
  3568. Autosize, !- Cooling Design Capacity {W}
  3569. 234.7, !- Cooling Design Capacity Per Floor Area {W/m2}
  3570. 1, !- Fraction of Autosized Cooling Design Capacity
  3571. HeatingDesignCapacity, !- Heating Design Capacity Method
  3572. Autosize, !- Heating Design Capacity {W}
  3573. 157, !- Heating Design Capacity Per Floor Area {W/m2}
  3574. 1, !- Fraction of Autosized Heating Design Capacity
  3575. OnOff; !- Central Cooling Capacity Control Method
  3576.  
  3577.  
  3578. !- =========== ALL OBJECTS IN CLASS: SIZING:PLANT ===========
  3579.  
  3580. Sizing:Plant,
  3581. Chilled Water Loop, !- Plant or Condenser Loop Name
  3582. Cooling, !- Loop Type
  3583. 7.22, !- Design Loop Exit Temperature {C}
  3584. 6.67, !- Loop Design Temperature Difference {deltaC}
  3585. NonCoincident, !- Sizing Option
  3586. 1, !- Zone Timesteps in Averaging Window
  3587. None; !- Coincident Sizing Factor Mode
  3588.  
  3589. Sizing:Plant,
  3590. Condenser Water Loop, !- Plant or Condenser Loop Name
  3591. Condenser, !- Loop Type
  3592. 29.4, !- Design Loop Exit Temperature {C}
  3593. 5.6, !- Loop Design Temperature Difference {deltaC}
  3594. NonCoincident, !- Sizing Option
  3595. 1, !- Zone Timesteps in Averaging Window
  3596. None; !- Coincident Sizing Factor Mode
  3597.  
  3598. Sizing:Plant,
  3599. Hot Water Loop, !- Plant or Condenser Loop Name
  3600. Heating, !- Loop Type
  3601. 82, !- Design Loop Exit Temperature {C}
  3602. 11, !- Loop Design Temperature Difference {deltaC}
  3603. NonCoincident, !- Sizing Option
  3604. 1, !- Zone Timesteps in Averaging Window
  3605. None; !- Coincident Sizing Factor Mode
  3606.  
  3607.  
  3608. !- =========== ALL OBJECTS IN CLASS: ZONECONTROL:THERMOSTAT ===========
  3609.  
  3610. ZoneControl:Thermostat,
  3611. Core_ZN Thermal Zone Thermostat, !- Name
  3612. Core_ZN Thermal Zone, !- Zone or ZoneList Name
  3613. Core_ZN Thermal Zone Thermostat Schedule, !- Control Type Schedule Name
  3614. ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type
  3615. {d762fbd3-b030-4bce-8777-ab3628fd4353}; !- Control 1 Name
  3616.  
  3617. ZoneControl:Thermostat,
  3618. Perimeter_ZN_1 Thermal Zone Thermostat, !- Name
  3619. Perimeter_ZN_1 Thermal Zone, !- Zone or ZoneList Name
  3620. Perimeter_ZN_1 Thermal Zone Thermostat Schedule, !- Control Type Schedule Name
  3621. ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type
  3622. {47ac1a6a-ec3e-4309-ac8b-2fab23364b74}; !- Control 1 Name
  3623.  
  3624. ZoneControl:Thermostat,
  3625. Perimeter_ZN_2 Thermal Zone Thermostat, !- Name
  3626. Perimeter_ZN_2 Thermal Zone, !- Zone or ZoneList Name
  3627. Perimeter_ZN_2 Thermal Zone Thermostat Schedule, !- Control Type Schedule Name
  3628. ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type
  3629. {9ae641f0-d02e-4056-9e0f-e0ac17475497}; !- Control 1 Name
  3630.  
  3631. ZoneControl:Thermostat,
  3632. Perimeter_ZN_3 Thermal Zone Thermostat, !- Name
  3633. Perimeter_ZN_3 Thermal Zone, !- Zone or ZoneList Name
  3634. Perimeter_ZN_3 Thermal Zone Thermostat Schedule, !- Control Type Schedule Name
  3635. ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type
  3636. {6daee1b8-4f60-4517-93d2-8c56f8316d74}; !- Control 1 Name
  3637.  
  3638. ZoneControl:Thermostat,
  3639. Perimeter_ZN_4 Thermal Zone Thermostat, !- Name
  3640. Perimeter_ZN_4 Thermal Zone, !- Zone or ZoneList Name
  3641. Perimeter_ZN_4 Thermal Zone Thermostat Schedule, !- Control Type Schedule Name
  3642. ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type
  3643. {7a485552-cf8e-442a-b093-148d244e6502}; !- Control 1 Name
  3644.  
  3645.  
  3646. !- =========== ALL OBJECTS IN CLASS: THERMOSTATSETPOINT:DUALSETPOINT ===========
  3647.  
  3648. ThermostatSetpoint:DualSetpoint,
  3649. {d762fbd3-b030-4bce-8777-ab3628fd4353}, !- Name
  3650. HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name
  3651. CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name
  3652.  
  3653. ThermostatSetpoint:DualSetpoint,
  3654. {47ac1a6a-ec3e-4309-ac8b-2fab23364b74}, !- Name
  3655. HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name
  3656. CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name
  3657.  
  3658. ThermostatSetpoint:DualSetpoint,
  3659. {9ae641f0-d02e-4056-9e0f-e0ac17475497}, !- Name
  3660. HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name
  3661. CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name
  3662.  
  3663. ThermostatSetpoint:DualSetpoint,
  3664. {6daee1b8-4f60-4517-93d2-8c56f8316d74}, !- Name
  3665. HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name
  3666. CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name
  3667.  
  3668. ThermostatSetpoint:DualSetpoint,
  3669. {7a485552-cf8e-442a-b093-148d244e6502}, !- Name
  3670. HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name
  3671. CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name
  3672.  
  3673.  
  3674. !- =========== ALL OBJECTS IN CLASS: AIRTERMINAL:SINGLEDUCT:VAV:REHEAT ===========
  3675.  
  3676. AirTerminal:SingleDuct:VAV:Reheat,
  3677. Air Terminal Single Duct VAV Reheat 1, !- Name
  3678. Always On Discrete, !- Availability Schedule Name
  3679. Air Terminal Single Duct VAV Reheat 1 Damper Outlet, !- Damper Air Outlet Node Name
  3680. VAV1 Box Inlet Node, !- Air Inlet Node Name
  3681. Autosize, !- Maximum Air Flow Rate {m3/s}
  3682. Constant, !- Zone Minimum Air Flow Input Method
  3683. 0.3, !- Constant Minimum Air Flow Fraction
  3684. 0, !- Fixed Minimum Air Flow Rate {m3/s}
  3685. , !- Minimum Air Flow Fraction Schedule Name
  3686. Coil:Heating:Water, !- Reheat Coil Object Type
  3687. Coil Heating Water 2, !- Reheat Coil Name
  3688. Autosize, !- Maximum Hot Water or Steam Flow Rate {m3/s}
  3689. 0, !- Minimum Hot Water or Steam Flow Rate {m3/s}
  3690. VAV1 Box Outlet Node, !- Air Outlet Node Name
  3691. 0.001, !- Convergence Tolerance
  3692. Normal, !- Damper Heating Action
  3693. Autocalculate, !- Maximum Flow per Zone Floor Area During Reheat {m3/s-m2}
  3694. Autocalculate, !- Maximum Flow Fraction During Reheat
  3695. 35; !- Maximum Reheat Air Temperature {C}
  3696.  
  3697. AirTerminal:SingleDuct:VAV:Reheat,
  3698. Air Terminal Single Duct VAV Reheat 2, !- Name
  3699. Always On Discrete, !- Availability Schedule Name
  3700. Air Terminal Single Duct VAV Reheat 2 Damper Outlet, !- Damper Air Outlet Node Name
  3701. VAV2 Box Inlet Node, !- Air Inlet Node Name
  3702. Autosize, !- Maximum Air Flow Rate {m3/s}
  3703. Constant, !- Zone Minimum Air Flow Input Method
  3704. 0.3, !- Constant Minimum Air Flow Fraction
  3705. 0, !- Fixed Minimum Air Flow Rate {m3/s}
  3706. , !- Minimum Air Flow Fraction Schedule Name
  3707. Coil:Heating:Water, !- Reheat Coil Object Type
  3708. Coil Heating Water 3, !- Reheat Coil Name
  3709. Autosize, !- Maximum Hot Water or Steam Flow Rate {m3/s}
  3710. 0, !- Minimum Hot Water or Steam Flow Rate {m3/s}
  3711. VAV2 Box Outlet Node, !- Air Outlet Node Name
  3712. 0.001, !- Convergence Tolerance
  3713. Normal, !- Damper Heating Action
  3714. Autocalculate, !- Maximum Flow per Zone Floor Area During Reheat {m3/s-m2}
  3715. Autocalculate, !- Maximum Flow Fraction During Reheat
  3716. 35; !- Maximum Reheat Air Temperature {C}
  3717.  
  3718. AirTerminal:SingleDuct:VAV:Reheat,
  3719. Air Terminal Single Duct VAV Reheat 3, !- Name
  3720. Always On Discrete, !- Availability Schedule Name
  3721. Air Terminal Single Duct VAV Reheat 3 Damper Outlet, !- Damper Air Outlet Node Name
  3722. VAV3 Box Inlet Node, !- Air Inlet Node Name
  3723. Autosize, !- Maximum Air Flow Rate {m3/s}
  3724. Constant, !- Zone Minimum Air Flow Input Method
  3725. 0.3, !- Constant Minimum Air Flow Fraction
  3726. 0, !- Fixed Minimum Air Flow Rate {m3/s}
  3727. , !- Minimum Air Flow Fraction Schedule Name
  3728. Coil:Heating:Water, !- Reheat Coil Object Type
  3729. Coil Heating Water 4, !- Reheat Coil Name
  3730. Autosize, !- Maximum Hot Water or Steam Flow Rate {m3/s}
  3731. 0, !- Minimum Hot Water or Steam Flow Rate {m3/s}
  3732. VAV3 Box Outlet Node, !- Air Outlet Node Name
  3733. 0.001, !- Convergence Tolerance
  3734. Normal, !- Damper Heating Action
  3735. Autocalculate, !- Maximum Flow per Zone Floor Area During Reheat {m3/s-m2}
  3736. Autocalculate, !- Maximum Flow Fraction During Reheat
  3737. 35; !- Maximum Reheat Air Temperature {C}
  3738.  
  3739. AirTerminal:SingleDuct:VAV:Reheat,
  3740. Air Terminal Single Duct VAV Reheat 4, !- Name
  3741. Always On Discrete, !- Availability Schedule Name
  3742. Air Terminal Single Duct VAV Reheat 4 Damper Outlet, !- Damper Air Outlet Node Name
  3743. VAV4 Box Inlet Node, !- Air Inlet Node Name
  3744. Autosize, !- Maximum Air Flow Rate {m3/s}
  3745. Constant, !- Zone Minimum Air Flow Input Method
  3746. 0.3, !- Constant Minimum Air Flow Fraction
  3747. 0, !- Fixed Minimum Air Flow Rate {m3/s}
  3748. , !- Minimum Air Flow Fraction Schedule Name
  3749. Coil:Heating:Water, !- Reheat Coil Object Type
  3750. Coil Heating Water 5, !- Reheat Coil Name
  3751. Autosize, !- Maximum Hot Water or Steam Flow Rate {m3/s}
  3752. 0, !- Minimum Hot Water or Steam Flow Rate {m3/s}
  3753. VAV4 Box Outlet Node, !- Air Outlet Node Name
  3754. 0.001, !- Convergence Tolerance
  3755. Normal, !- Damper Heating Action
  3756. Autocalculate, !- Maximum Flow per Zone Floor Area During Reheat {m3/s-m2}
  3757. Autocalculate, !- Maximum Flow Fraction During Reheat
  3758. 35; !- Maximum Reheat Air Temperature {C}
  3759.  
  3760. AirTerminal:SingleDuct:VAV:Reheat,
  3761. Air Terminal Single Duct VAV Reheat 5, !- Name
  3762. Always On Discrete, !- Availability Schedule Name
  3763. Air Terminal Single Duct VAV Reheat 5 Damper Outlet, !- Damper Air Outlet Node Name
  3764. VAV5 Box Inlet Node, !- Air Inlet Node Name
  3765. Autosize, !- Maximum Air Flow Rate {m3/s}
  3766. Constant, !- Zone Minimum Air Flow Input Method
  3767. 0.3, !- Constant Minimum Air Flow Fraction
  3768. 0, !- Fixed Minimum Air Flow Rate {m3/s}
  3769. , !- Minimum Air Flow Fraction Schedule Name
  3770. Coil:Heating:Water, !- Reheat Coil Object Type
  3771. Coil Heating Water 6, !- Reheat Coil Name
  3772. Autosize, !- Maximum Hot Water or Steam Flow Rate {m3/s}
  3773. 0, !- Minimum Hot Water or Steam Flow Rate {m3/s}
  3774. VAV5 Box Outlet Node, !- Air Outlet Node Name
  3775. 0.001, !- Convergence Tolerance
  3776. Normal, !- Damper Heating Action
  3777. Autocalculate, !- Maximum Flow per Zone Floor Area During Reheat {m3/s-m2}
  3778. Autocalculate, !- Maximum Flow Fraction During Reheat
  3779. 35; !- Maximum Reheat Air Temperature {C}
  3780.  
  3781.  
  3782. !- =========== ALL OBJECTS IN CLASS: ZONEHVAC:AIRDISTRIBUTIONUNIT ===========
  3783.  
  3784. ZoneHVAC:AirDistributionUnit,
  3785. ADU Air Terminal Single Duct VAV Reheat 1, !- Name
  3786. VAV1 Box Outlet Node, !- Air Distribution Unit Outlet Node Name
  3787. AirTerminal:SingleDuct:VAV:Reheat, !- Air Terminal Object Type
  3788. Air Terminal Single Duct VAV Reheat 1; !- Air Terminal Name
  3789.  
  3790. ZoneHVAC:AirDistributionUnit,
  3791. ADU Air Terminal Single Duct VAV Reheat 2, !- Name
  3792. VAV2 Box Outlet Node, !- Air Distribution Unit Outlet Node Name
  3793. AirTerminal:SingleDuct:VAV:Reheat, !- Air Terminal Object Type
  3794. Air Terminal Single Duct VAV Reheat 2; !- Air Terminal Name
  3795.  
  3796. ZoneHVAC:AirDistributionUnit,
  3797. ADU Air Terminal Single Duct VAV Reheat 3, !- Name
  3798. VAV3 Box Outlet Node, !- Air Distribution Unit Outlet Node Name
  3799. AirTerminal:SingleDuct:VAV:Reheat, !- Air Terminal Object Type
  3800. Air Terminal Single Duct VAV Reheat 3; !- Air Terminal Name
  3801.  
  3802. ZoneHVAC:AirDistributionUnit,
  3803. ADU Air Terminal Single Duct VAV Reheat 4, !- Name
  3804. VAV4 Box Outlet Node, !- Air Distribution Unit Outlet Node Name
  3805. AirTerminal:SingleDuct:VAV:Reheat, !- Air Terminal Object Type
  3806. Air Terminal Single Duct VAV Reheat 4; !- Air Terminal Name
  3807.  
  3808. ZoneHVAC:AirDistributionUnit,
  3809. ADU Air Terminal Single Duct VAV Reheat 5, !- Name
  3810. VAV5 Box Outlet Node, !- Air Distribution Unit Outlet Node Name
  3811. AirTerminal:SingleDuct:VAV:Reheat, !- Air Terminal Object Type
  3812. Air Terminal Single Duct VAV Reheat 5; !- Air Terminal Name
  3813.  
  3814.  
  3815. !- =========== ALL OBJECTS IN CLASS: ZONEHVAC:EQUIPMENTLIST ===========
  3816.  
  3817. ZoneHVAC:EquipmentList,
  3818. Core_ZN Thermal Zone Equipment List, !- Name
  3819. ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type
  3820. ADU Air Terminal Single Duct VAV Reheat 1, !- Zone Equipment 1 Name
  3821. 1, !- Zone Equipment 1 Cooling Sequence
  3822. 1; !- Zone Equipment 1 Heating or No-Load Sequence
  3823.  
  3824. ZoneHVAC:EquipmentList,
  3825. Perimeter_ZN_1 Thermal Zone Equipment List, !- Name
  3826. ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type
  3827. ADU Air Terminal Single Duct VAV Reheat 2, !- Zone Equipment 1 Name
  3828. 1, !- Zone Equipment 1 Cooling Sequence
  3829. 1; !- Zone Equipment 1 Heating or No-Load Sequence
  3830.  
  3831. ZoneHVAC:EquipmentList,
  3832. Perimeter_ZN_2 Thermal Zone Equipment List, !- Name
  3833. ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type
  3834. ADU Air Terminal Single Duct VAV Reheat 3, !- Zone Equipment 1 Name
  3835. 1, !- Zone Equipment 1 Cooling Sequence
  3836. 1; !- Zone Equipment 1 Heating or No-Load Sequence
  3837.  
  3838. ZoneHVAC:EquipmentList,
  3839. Perimeter_ZN_3 Thermal Zone Equipment List, !- Name
  3840. ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type
  3841. ADU Air Terminal Single Duct VAV Reheat 4, !- Zone Equipment 1 Name
  3842. 1, !- Zone Equipment 1 Cooling Sequence
  3843. 1; !- Zone Equipment 1 Heating or No-Load Sequence
  3844.  
  3845. ZoneHVAC:EquipmentList,
  3846. Perimeter_ZN_4 Thermal Zone Equipment List, !- Name
  3847. ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type
  3848. ADU Air Terminal Single Duct VAV Reheat 5, !- Zone Equipment 1 Name
  3849. 1, !- Zone Equipment 1 Cooling Sequence
  3850. 1; !- Zone Equipment 1 Heating or No-Load Sequence
  3851.  
  3852.  
  3853. !- =========== ALL OBJECTS IN CLASS: ZONEHVAC:EQUIPMENTCONNECTIONS ===========
  3854.  
  3855. ZoneHVAC:EquipmentConnections,
  3856. Core_ZN Thermal Zone, !- Zone Name
  3857. Core_ZN Thermal Zone Equipment List, !- Zone Conditioning Equipment List Name
  3858. VAV1 Box Outlet Node, !- Zone Air Inlet Node or NodeList Name
  3859. , !- Zone Air Exhaust Node or NodeList Name
  3860. ZoneCore, !- Zone Air Node Name
  3861. ZoneCore Return Air Node;!- Zone Return Air Node Name
  3862.  
  3863. ZoneHVAC:EquipmentConnections,
  3864. Perimeter_ZN_1 Thermal Zone, !- Zone Name
  3865. Perimeter_ZN_1 Thermal Zone Equipment List, !- Zone Conditioning Equipment List Name
  3866. VAV2 Box Outlet Node, !- Zone Air Inlet Node or NodeList Name
  3867. , !- Zone Air Exhaust Node or NodeList Name
  3868. Perimeter_ZN_1 Node, !- Zone Air Node Name
  3869. P_ZN_1 Return Air Node; !- Zone Return Air Node Name
  3870.  
  3871. ZoneHVAC:EquipmentConnections,
  3872. Perimeter_ZN_2 Thermal Zone, !- Zone Name
  3873. Perimeter_ZN_2 Thermal Zone Equipment List, !- Zone Conditioning Equipment List Name
  3874. VAV3 Box Outlet Node, !- Zone Air Inlet Node or NodeList Name
  3875. , !- Zone Air Exhaust Node or NodeList Name
  3876. Perimeter_ZN_2 Node, !- Zone Air Node Name
  3877. P_ZN_2 Return Air Node; !- Zone Return Air Node Name
  3878.  
  3879. ZoneHVAC:EquipmentConnections,
  3880. Perimeter_ZN_3 Thermal Zone, !- Zone Name
  3881. Perimeter_ZN_3 Thermal Zone Equipment List, !- Zone Conditioning Equipment List Name
  3882. VAV4 Box Outlet Node, !- Zone Air Inlet Node or NodeList Name
  3883. , !- Zone Air Exhaust Node or NodeList Name
  3884. Perimeter_ZN_3 Node, !- Zone Air Node Name
  3885. P_ZN_3 Return Air Node; !- Zone Return Air Node Name
  3886.  
  3887. ZoneHVAC:EquipmentConnections,
  3888. Perimeter_ZN_4 Thermal Zone, !- Zone Name
  3889. Perimeter_ZN_4 Thermal Zone Equipment List, !- Zone Conditioning Equipment List Name
  3890. VAV5 Box Outlet Node, !- Zone Air Inlet Node or NodeList Name
  3891. , !- Zone Air Exhaust Node or NodeList Name
  3892. Perimeter_ZN_4 Node, !- Zone Air Node Name
  3893. P_ZN_4 Return Air Node; !- Zone Return Air Node Name
  3894.  
  3895.  
  3896. !- =========== ALL OBJECTS IN CLASS: FAN:VARIABLEVOLUME ===========
  3897.  
  3898. Fan:VariableVolume,
  3899. Fan Variable Volume 1, !- Name
  3900. FanAvailSched, !- Availability Schedule Name
  3901. 0.6045, !- Fan Total Efficiency
  3902. 500, !- Pressure Rise {Pa}
  3903. AutoSize, !- Maximum Flow Rate {m3/s}
  3904. Fraction, !- Fan Power Minimum Flow Rate Input Method
  3905. 0, !- Fan Power Minimum Flow Fraction
  3906. 0, !- Fan Power Minimum Air Flow Rate {m3/s}
  3907. 0.93, !- Motor Efficiency
  3908. 1, !- Motor In Airstream Fraction
  3909. 0.040759894, !- Fan Power Coefficient 1
  3910. 0.08804497, !- Fan Power Coefficient 2
  3911. -0.07292612, !- Fan Power Coefficient 3
  3912. 0.943739823, !- Fan Power Coefficient 4
  3913. 0, !- Fan Power Coefficient 5
  3914. HC Air Outlet Node1, !- Air Inlet Node Name
  3915. Air Outlet Node1; !- Air Outlet Node Name
  3916.  
  3917.  
  3918. !- =========== ALL OBJECTS IN CLASS: COIL:COOLING:WATER ===========
  3919.  
  3920. Coil:Cooling:Water,
  3921. Coil Cooling Water 1, !- Name
  3922. Always On Discrete, !- Availability Schedule Name
  3923. Autosize, !- Design Water Flow Rate {m3/s}
  3924. Autosize, !- Design Air Flow Rate {m3/s}
  3925. Autosize, !- Design Inlet Water Temperature {C}
  3926. Autosize, !- Design Inlet Air Temperature {C}
  3927. Autosize, !- Design Outlet Air Temperature {C}
  3928. Autosize, !- Design Inlet Air Humidity Ratio {kgWater/kgDryAir}
  3929. Autosize, !- Design Outlet Air Humidity Ratio {kgWater/kgDryAir}
  3930. CC1 Water Inlet Node, !- Water Inlet Node Name
  3931. CC1 Water Outlet Node, !- Water Outlet Node Name
  3932. Mixed Air Node1, !- Air Inlet Node Name
  3933. CC Air Outlet Node1, !- Air Outlet Node Name
  3934. SimpleAnalysis, !- Type of Analysis
  3935. CounterFlow; !- Heat Exchanger Configuration
  3936.  
  3937. Coil:Cooling:Water,
  3938. Coil Cooling Water 2, !- Name
  3939. Always On Discrete, !- Availability Schedule Name
  3940. Autosize, !- Design Water Flow Rate {m3/s}
  3941. Autosize, !- Design Air Flow Rate {m3/s}
  3942. Autosize, !- Design Inlet Water Temperature {C}
  3943. Autosize, !- Design Inlet Air Temperature {C}
  3944. Autosize, !- Design Outlet Air Temperature {C}
  3945. Autosize, !- Design Inlet Air Humidity Ratio {kgWater/kgDryAir}
  3946. Autosize, !- Design Outlet Air Humidity Ratio {kgWater/kgDryAir}
  3947. CC2 Water Inlet Node, !- Water Inlet Node Name
  3948. CC2 Water Outlet Node, !- Water Outlet Node Name
  3949. CC2 Air Inlet Node, !- Air Inlet Node Name
  3950. CC2 Air Outlet Node, !- Air Outlet Node Name
  3951. SimpleAnalysis, !- Type of Analysis
  3952. CounterFlow; !- Heat Exchanger Configuration
  3953.  
  3954.  
  3955. !- =========== ALL OBJECTS IN CLASS: COIL:HEATING:WATER ===========
  3956.  
  3957. Coil:Heating:Water,
  3958. Coil Heating Water 2, !- Name
  3959. Always On Discrete, !- Availability Schedule Name
  3960. Autosize, !- U-Factor Times Area Value {W/K}
  3961. Autosize, !- Maximum Water Flow Rate {m3/s}
  3962. Node 42, !- Water Inlet Node Name
  3963. Node 43, !- Water Outlet Node Name
  3964. Air Terminal Single Duct VAV Reheat 1 Damper Outlet, !- Air Inlet Node Name
  3965. VAV1 Box Outlet Node, !- Air Outlet Node Name
  3966. UFactorTimesAreaAndDesignWaterFlowRate, !- Performance Input Method
  3967. Autosize, !- Rated Capacity {W}
  3968. 82.2, !- Rated Inlet Water Temperature {C}
  3969. 16.6, !- Rated Inlet Air Temperature {C}
  3970. 71.1, !- Rated Outlet Water Temperature {C}
  3971. 32.2, !- Rated Outlet Air Temperature {C}
  3972. 0.5; !- Rated Ratio for Air and Water Convection
  3973.  
  3974. Coil:Heating:Water,
  3975. Coil Heating Water 3, !- Name
  3976. Always On Discrete, !- Availability Schedule Name
  3977. Autosize, !- U-Factor Times Area Value {W/K}
  3978. Autosize, !- Maximum Water Flow Rate {m3/s}
  3979. Node 63, !- Water Inlet Node Name
  3980. Node 64, !- Water Outlet Node Name
  3981. Air Terminal Single Duct VAV Reheat 2 Damper Outlet, !- Air Inlet Node Name
  3982. VAV2 Box Outlet Node, !- Air Outlet Node Name
  3983. UFactorTimesAreaAndDesignWaterFlowRate, !- Performance Input Method
  3984. Autosize, !- Rated Capacity {W}
  3985. 82.2, !- Rated Inlet Water Temperature {C}
  3986. 16.6, !- Rated Inlet Air Temperature {C}
  3987. 71.1, !- Rated Outlet Water Temperature {C}
  3988. 32.2, !- Rated Outlet Air Temperature {C}
  3989. 0.5; !- Rated Ratio for Air and Water Convection
  3990.  
  3991. Coil:Heating:Water,
  3992. Coil Heating Water 4, !- Name
  3993. Always On Discrete, !- Availability Schedule Name
  3994. Autosize, !- U-Factor Times Area Value {W/K}
  3995. Autosize, !- Maximum Water Flow Rate {m3/s}
  3996. Node 68, !- Water Inlet Node Name
  3997. Node 69, !- Water Outlet Node Name
  3998. Air Terminal Single Duct VAV Reheat 3 Damper Outlet, !- Air Inlet Node Name
  3999. VAV3 Box Outlet Node, !- Air Outlet Node Name
  4000. UFactorTimesAreaAndDesignWaterFlowRate, !- Performance Input Method
  4001. Autosize, !- Rated Capacity {W}
  4002. 82.2, !- Rated Inlet Water Temperature {C}
  4003. 16.6, !- Rated Inlet Air Temperature {C}
  4004. 71.1, !- Rated Outlet Water Temperature {C}
  4005. 32.2, !- Rated Outlet Air Temperature {C}
  4006. 0.5; !- Rated Ratio for Air and Water Convection
  4007.  
  4008. Coil:Heating:Water,
  4009. Coil Heating Water 5, !- Name
  4010. Always On Discrete, !- Availability Schedule Name
  4011. Autosize, !- U-Factor Times Area Value {W/K}
  4012. Autosize, !- Maximum Water Flow Rate {m3/s}
  4013. Node 73, !- Water Inlet Node Name
  4014. Node 74, !- Water Outlet Node Name
  4015. Air Terminal Single Duct VAV Reheat 4 Damper Outlet, !- Air Inlet Node Name
  4016. VAV4 Box Outlet Node, !- Air Outlet Node Name
  4017. UFactorTimesAreaAndDesignWaterFlowRate, !- Performance Input Method
  4018. Autosize, !- Rated Capacity {W}
  4019. 82.2, !- Rated Inlet Water Temperature {C}
  4020. 16.6, !- Rated Inlet Air Temperature {C}
  4021. 71.1, !- Rated Outlet Water Temperature {C}
  4022. 32.2, !- Rated Outlet Air Temperature {C}
  4023. 0.5; !- Rated Ratio for Air and Water Convection
  4024.  
  4025. Coil:Heating:Water,
  4026. Coil Heating Water 6, !- Name
  4027. Always On Discrete, !- Availability Schedule Name
  4028. Autosize, !- U-Factor Times Area Value {W/K}
  4029. Autosize, !- Maximum Water Flow Rate {m3/s}
  4030. Node 78, !- Water Inlet Node Name
  4031. Node 79, !- Water Outlet Node Name
  4032. Air Terminal Single Duct VAV Reheat 5 Damper Outlet, !- Air Inlet Node Name
  4033. VAV5 Box Outlet Node, !- Air Outlet Node Name
  4034. UFactorTimesAreaAndDesignWaterFlowRate, !- Performance Input Method
  4035. Autosize, !- Rated Capacity {W}
  4036. 82.2, !- Rated Inlet Water Temperature {C}
  4037. 16.6, !- Rated Inlet Air Temperature {C}
  4038. 71.1, !- Rated Outlet Water Temperature {C}
  4039. 32.2, !- Rated Outlet Air Temperature {C}
  4040. 0.5; !- Rated Ratio for Air and Water Convection
  4041.  
  4042. Coil:Heating:Water,
  4043. Coil Heating Water 1, !- Name
  4044. Always On Discrete, !- Availability Schedule Name
  4045. Autosize, !- U-Factor Times Area Value {W/K}
  4046. Autosize, !- Maximum Water Flow Rate {m3/s}
  4047. HC1 Water Inlet Node, !- Water Inlet Node Name
  4048. HC1 Water Outlet Node, !- Water Outlet Node Name
  4049. CC Air Outlet Node1, !- Air Inlet Node Name
  4050. HC Air Outlet Node1, !- Air Outlet Node Name
  4051. UFactorTimesAreaAndDesignWaterFlowRate, !- Performance Input Method
  4052. Autosize, !- Rated Capacity {W}
  4053. 82.2, !- Rated Inlet Water Temperature {C}
  4054. 16.6, !- Rated Inlet Air Temperature {C}
  4055. 71.1, !- Rated Outlet Water Temperature {C}
  4056. 32.2, !- Rated Outlet Air Temperature {C}
  4057. 0.5; !- Rated Ratio for Air and Water Convection
  4058.  
  4059.  
  4060. !- =========== ALL OBJECTS IN CLASS: CONTROLLER:WATERCOIL ===========
  4061.  
  4062. Controller:WaterCoil,
  4063. Controller Water Coil 2, !- Name
  4064. Temperature, !- Control Variable
  4065. Reverse, !- Action
  4066. Flow, !- Actuator Variable
  4067. CC Air Outlet Node1, !- Sensor Node Name
  4068. CC1 Water Inlet Node, !- Actuator Node Name
  4069. Autosize, !- Controller Convergence Tolerance {deltaC}
  4070. Autosize, !- Maximum Actuated Flow {m3/s}
  4071. 0; !- Minimum Actuated Flow {m3/s}
  4072.  
  4073. Controller:WaterCoil,
  4074. Controller Water Coil 1, !- Name
  4075. Temperature, !- Control Variable
  4076. Normal, !- Action
  4077. Flow, !- Actuator Variable
  4078. HC Air Outlet Node1, !- Sensor Node Name
  4079. HC1 Water Inlet Node, !- Actuator Node Name
  4080. Autosize, !- Controller Convergence Tolerance {deltaC}
  4081. Autosize, !- Maximum Actuated Flow {m3/s}
  4082. 0; !- Minimum Actuated Flow {m3/s}
  4083.  
  4084.  
  4085. !- =========== ALL OBJECTS IN CLASS: CONTROLLER:OUTDOORAIR ===========
  4086.  
  4087. Controller:OutdoorAir,
  4088. Controller Outdoor Air 1,!- Name
  4089. Relief Air Node1, !- Relief Air Outlet Node Name
  4090. Air Inlet Node1, !- Return Air Node Name
  4091. Mixed Air Node1, !- Mixed Air Node Name
  4092. Outdoor Air Node, !- Actuator Node Name
  4093. Autosize, !- Minimum Outdoor Air Flow Rate {m3/s}
  4094. Autosize, !- Maximum Outdoor Air Flow Rate {m3/s}
  4095. NoEconomizer, !- Economizer Control Type
  4096. ModulateFlow, !- Economizer Control Action Type
  4097. 28, !- Economizer Maximum Limit Dry-Bulb Temperature {C}
  4098. 64000, !- Economizer Maximum Limit Enthalpy {J/kg}
  4099. , !- Economizer Maximum Limit Dewpoint Temperature {C}
  4100. , !- Electronic Enthalpy Limit Curve Name
  4101. 0, !- Economizer Minimum Limit Dry-Bulb Temperature {C}
  4102. NoLockout, !- Lockout Type
  4103. FixedMinimum, !- Minimum Limit Type
  4104. MinOA_Sched, !- Minimum Outdoor Air Schedule Name
  4105. , !- Minimum Fraction of Outdoor Air Schedule Name
  4106. , !- Maximum Fraction of Outdoor Air Schedule Name
  4107. Controller Mechanical Ventilation 1, !- Mechanical Ventilation Controller Name
  4108. , !- Time of Day Economizer Control Schedule Name
  4109. No, !- High Humidity Control
  4110. , !- Humidistat Control Zone Name
  4111. , !- High Humidity Outdoor Air Flow Ratio
  4112. Yes, !- Control High Indoor Humidity Based on Outdoor Humidity Ratio
  4113. BypassWhenWithinEconomizerLimits; !- Heat Recovery Bypass Control Type
  4114.  
  4115.  
  4116. !- =========== ALL OBJECTS IN CLASS: CONTROLLER:MECHANICALVENTILATION ===========
  4117.  
  4118. Controller:MechanicalVentilation,
  4119. Controller Mechanical Ventilation 1, !- Name
  4120. Always On Discrete, !- Availability Schedule Name
  4121. No, !- Demand Controlled Ventilation
  4122. ZoneSum, !- System Outdoor Air Method
  4123. , !- Zone Maximum Outdoor Air Fraction {dimensionless}
  4124. Core_ZN Thermal Zone, !- Zone 1 Name
  4125. SZ DSOA Core_ZN, !- Design Specification Outdoor Air Object Name 1
  4126. Core_ZN Thermal Zone Design Spec Zone Air Dist, !- Design Specification Zone Air Distribution Object Name 1
  4127. Perimeter_ZN_1 Thermal Zone, !- Zone 2 Name
  4128. SZ DSOA Perimeter_ZN_1, !- Design Specification Outdoor Air Object Name 2
  4129. Perimeter_ZN_1 Thermal Zone Design Spec Zone Air Dist, !- Design Specification Zone Air Distribution Object Name 2
  4130. Perimeter_ZN_2 Thermal Zone, !- Zone 3 Name
  4131. SZ DSOA Perimeter_ZN_2, !- Design Specification Outdoor Air Object Name 3
  4132. Perimeter_ZN_2 Thermal Zone Design Spec Zone Air Dist, !- Design Specification Zone Air Distribution Object Name 3
  4133. Perimeter_ZN_3 Thermal Zone, !- Zone 4 Name
  4134. SZ DSOA Perimeter_ZN_3, !- Design Specification Outdoor Air Object Name 4
  4135. Perimeter_ZN_3 Thermal Zone Design Spec Zone Air Dist, !- Design Specification Zone Air Distribution Object Name 4
  4136. Perimeter_ZN_4 Thermal Zone, !- Zone 5 Name
  4137. SZ DSOA Perimeter_ZN_4, !- Design Specification Outdoor Air Object Name 5
  4138. Perimeter_ZN_4 Thermal Zone Design Spec Zone Air Dist; !- Design Specification Zone Air Distribution Object Name 5
  4139.  
  4140.  
  4141. !- =========== ALL OBJECTS IN CLASS: AIRLOOPHVAC:CONTROLLERLIST ===========
  4142.  
  4143. AirLoopHVAC:ControllerList,
  4144. VAV with Reheat Coil Controllers, !- Name
  4145. Controller:WaterCoil, !- Controller 1 Object Type
  4146. Controller Water Coil 2, !- Controller 1 Name
  4147. Controller:WaterCoil, !- Controller 2 Object Type
  4148. Controller Water Coil 1; !- Controller 2 Name
  4149.  
  4150. AirLoopHVAC:ControllerList,
  4151. Air Loop HVAC Outdoor Air System 1 Controller List, !- Name
  4152. Controller:OutdoorAir, !- Controller 1 Object Type
  4153. Controller Outdoor Air 1;!- Controller 1 Name
  4154.  
  4155.  
  4156. !- =========== ALL OBJECTS IN CLASS: AIRLOOPHVAC ===========
  4157.  
  4158. AirLoopHVAC,
  4159. VAV with Reheat, !- Name
  4160. VAV with Reheat Coil Controllers, !- Controller List Name
  4161. AHU1 Availability Manager List, !- Availability Manager List Name
  4162. AutoSize, !- Design Supply Air Flow Rate {m3/s}
  4163. Air Loop Supply Branches,!- Branch List Name
  4164. , !- Connector List Name
  4165. Air Inlet Node1, !- Supply Side Inlet Node Name
  4166. Air Demand Outlet Node1, !- Demand Side Outlet Node Name
  4167. Air Demand Inlet Node1, !- Demand Side Inlet Node Names
  4168. Air Outlet Node1; !- Supply Side Outlet Node Names
  4169.  
  4170.  
  4171. !- =========== ALL OBJECTS IN CLASS: AIRLOOPHVAC:OUTDOORAIRSYSTEM:EQUIPMENTLIST ===========
  4172.  
  4173. AirLoopHVAC:OutdoorAirSystem:EquipmentList,
  4174. Air Loop HVAC Outdoor Air System 1 Equipment List, !- Name
  4175. OutdoorAir:Mixer, !- Component 1 Object Type
  4176. Air Loop HVAC Outdoor Air System 1 Outdoor Air Mixer; !- Component 1 Name
  4177.  
  4178.  
  4179. !- =========== ALL OBJECTS IN CLASS: AIRLOOPHVAC:OUTDOORAIRSYSTEM ===========
  4180.  
  4181. AirLoopHVAC:OutdoorAirSystem,
  4182. Air Loop HVAC Outdoor Air System 1, !- Name
  4183. Air Loop HVAC Outdoor Air System 1 Controller List, !- Controller List Name
  4184. Air Loop HVAC Outdoor Air System 1 Equipment List, !- Outdoor Air Equipment List Name
  4185. AHU1 Availability Manager List; !- Availability Manager List Name
  4186.  
  4187.  
  4188. !- =========== ALL OBJECTS IN CLASS: OUTDOORAIR:MIXER ===========
  4189.  
  4190. OutdoorAir:Mixer,
  4191. Air Loop HVAC Outdoor Air System 1 Outdoor Air Mixer, !- Name
  4192. Mixed Air Node1, !- Mixed Air Node Name
  4193. Outdoor Air Node, !- Outdoor Air Stream Node Name
  4194. Relief Air Node1, !- Relief Air Stream Node Name
  4195. Air Inlet Node1; !- Return Air Stream Node Name
  4196.  
  4197.  
  4198. !- =========== ALL OBJECTS IN CLASS: AIRLOOPHVAC:ZONESPLITTER ===========
  4199.  
  4200. AirLoopHVAC:ZoneSplitter,
  4201. Air Loop HVAC Zone Splitter 1, !- Name
  4202. Air Demand Inlet Node1, !- Inlet Node Name
  4203. VAV1 Box Inlet Node, !- Outlet 1 Node Name
  4204. VAV2 Box Inlet Node, !- Outlet 2 Node Name
  4205. VAV3 Box Inlet Node, !- Outlet 3 Node Name
  4206. VAV4 Box Inlet Node, !- Outlet 4 Node Name
  4207. VAV5 Box Inlet Node; !- Outlet 5 Node Name
  4208.  
  4209.  
  4210. !- =========== ALL OBJECTS IN CLASS: AIRLOOPHVAC:SUPPLYPATH ===========
  4211.  
  4212. AirLoopHVAC:SupplyPath,
  4213. VAV with Reheat Node 3 Supply Path, !- Name
  4214. Air Demand Inlet Node1, !- Supply Air Path Inlet Node Name
  4215. AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type
  4216. Air Loop HVAC Zone Splitter 1; !- Component 1 Name
  4217.  
  4218.  
  4219. !- =========== ALL OBJECTS IN CLASS: AIRLOOPHVAC:ZONEMIXER ===========
  4220.  
  4221. AirLoopHVAC:ZoneMixer,
  4222. Air Loop HVAC Return Mixer 1, !- Name
  4223. Air Demand Outlet Node1, !- Outlet Node Name
  4224. ZoneCore Return Air Node,!- Inlet 1 Node Name
  4225. P_ZN_1 Return Air Node, !- Inlet 2 Node Name
  4226. P_ZN_2 Return Air Node, !- Inlet 3 Node Name
  4227. P_ZN_3 Return Air Node, !- Inlet 4 Node Name
  4228. P_ZN_4 Return Air Node; !- Inlet 5 Node Name
  4229.  
  4230.  
  4231. !- =========== ALL OBJECTS IN CLASS: AIRLOOPHVAC:RETURNPATH ===========
  4232.  
  4233. AirLoopHVAC:ReturnPath,
  4234. VAV with Reheat Return Path, !- Name
  4235. Air Demand Outlet Node1, !- Return Air Path Outlet Node Name
  4236. AirLoopHVAC:ZoneMixer, !- Component 1 Object Type
  4237. Air Loop HVAC Return Mixer 1; !- Component 1 Name
  4238.  
  4239.  
  4240. !- =========== ALL OBJECTS IN CLASS: BRANCH ===========
  4241.  
  4242. Branch,
  4243. Air Loop Main Branch1, !- Name
  4244. Autosize, !- Maximum Flow Rate {m3/s}
  4245. , !- Pressure Drop Curve Name
  4246. AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type
  4247. Air Loop HVAC Outdoor Air System 1, !- Component 1 Name
  4248. Air Inlet Node1, !- Component 1 Inlet Node Name
  4249. Mixed Air Node1, !- Component 1 Outlet Node Name
  4250. Passive, !- Component 1 Branch Control Type
  4251. Coil:Cooling:Water, !- Component 2 Object Type
  4252. Coil Cooling Water 1, !- Component 2 Name
  4253. Mixed Air Node1, !- Component 2 Inlet Node Name
  4254. CC Air Outlet Node1, !- Component 2 Outlet Node Name
  4255. Passive, !- Component 2 Branch Control Type
  4256. Coil:Heating:Water, !- Component 3 Object Type
  4257. Coil Heating Water 1, !- Component 3 Name
  4258. CC Air Outlet Node1, !- Component 3 Inlet Node Name
  4259. HC Air Outlet Node1, !- Component 3 Outlet Node Name
  4260. Passive, !- Component 3 Branch Control Type
  4261. Fan:VariableVolume, !- Component 4 Object Type
  4262. Fan Variable Volume 1, !- Component 4 Name
  4263. HC Air Outlet Node1, !- Component 4 Inlet Node Name
  4264. Air Outlet Node1, !- Component 4 Outlet Node Name
  4265. Passive; !- Component 4 Branch Control Type
  4266.  
  4267. Branch,
  4268. Chilled Water Loop Supply Inlet Branch, !- Name
  4269. autosize, !- Maximum Flow Rate {m3/s}
  4270. , !- Pressure Drop Curve Name
  4271. Pump:VariableSpeed, !- Component 1 Object Type
  4272. CW Supply Pump, !- Component 1 Name
  4273. CW Supply Inlet Node, !- Component 1 Inlet Node Name
  4274. CW Supply Pump Outlet Node, !- Component 1 Outlet Node Name
  4275. Passive; !- Component 1 Branch Control Type
  4276.  
  4277. Branch,
  4278. Chilled Water Loop Chiller Branch 1, !- Name
  4279. autosize, !- Maximum Flow Rate {m3/s}
  4280. , !- Pressure Drop Curve Name
  4281. Chiller:Electric:EIR, !- Component 1 Object Type
  4282. Chiller Electric EIR 1, !- Component 1 Name
  4283. Chiller Inlet Node, !- Component 1 Inlet Node Name
  4284. Chiller Outlet Node, !- Component 1 Outlet Node Name
  4285. Active; !- Component 1 Branch Control Type
  4286.  
  4287. Branch,
  4288. Chilled Water Loop Supply Bypass Branch, !- Name
  4289. autosize, !- Maximum Flow Rate {m3/s}
  4290. , !- Pressure Drop Curve Name
  4291. Pipe:Adiabatic, !- Component 1 Object Type
  4292. CW Supply Bypass Pipe, !- Component 1 Name
  4293. CW Supply Bypass Inlet Node, !- Component 1 Inlet Node Name
  4294. CW Supply Bypass Outlet Node, !- Component 1 Outlet Node Name
  4295. Passive; !- Component 1 Branch Control Type
  4296.  
  4297. Branch,
  4298. Chilled Water Loop Supply Outlet Branch, !- Name
  4299. autosize, !- Maximum Flow Rate {m3/s}
  4300. , !- Pressure Drop Curve Name
  4301. Pipe:Adiabatic, !- Component 1 Object Type
  4302. CW Supply Outlet Bypass Pipe, !- Component 1 Name
  4303. CW Supply Outlet Pipe Inlet Node, !- Component 1 Inlet Node Name
  4304. CW Supply Outlet Node, !- Component 1 Outlet Node Name
  4305. Passive; !- Component 1 Branch Control Type
  4306.  
  4307. Branch,
  4308. Chilled Water Loop Demand Inlet Branch, !- Name
  4309. autosize, !- Maximum Flow Rate {m3/s}
  4310. , !- Pressure Drop Curve Name
  4311. Pipe:Adiabatic, !- Component 1 Object Type
  4312. CW Demand Inlet Pipe, !- Component 1 Name
  4313. CW Demand Inlet Node, !- Component 1 Inlet Node Name
  4314. CW Demand inlet Pipe Outlet Node, !- Component 1 Outlet Node Name
  4315. Passive; !- Component 1 Branch Control Type
  4316.  
  4317. Branch,
  4318. CW Loop Demand TES Branch 1, !- Name
  4319. autosize, !- Maximum Flow Rate {m3/s}
  4320. , !- Pressure Drop Curve Name
  4321. ThermalStorage:ChilledWater:Stratified, !- Component 1 Object Type
  4322. TES Chilled Water Stratified, !- Component 1 Name
  4323. TES Inlet Node, !- Component 1 Inlet Node Name
  4324. TES Outlet Node, !- Component 1 Outlet Node Name
  4325. Passive; !- Component 1 Branch Control Type
  4326.  
  4327. Branch,
  4328. Chilled Water Loop Demand Bypass Branch, !- Name
  4329. autosize, !- Maximum Flow Rate {m3/s}
  4330. , !- Pressure Drop Curve Name
  4331. Pipe:Adiabatic, !- Component 1 Object Type
  4332. Chilled Water Loop Demand Bypass Pipe, !- Component 1 Name
  4333. Chilled Water Loop Demand Bypass Pipe Inlet Node, !- Component 1 Inlet Node Name
  4334. Chilled Water Loop Demand Bypass Pipe Outlet Node, !- Component 1 Outlet Node Name
  4335. Bypass; !- Component 1 Branch Control Type
  4336.  
  4337. Branch,
  4338. Chilled Water Loop Demand Outlet Branch, !- Name
  4339. autosize, !- Maximum Flow Rate {m3/s}
  4340. , !- Pressure Drop Curve Name
  4341. Pipe:Adiabatic, !- Component 1 Object Type
  4342. CW Demand Outlet Pipe, !- Component 1 Name
  4343. CW Outlet Pipe Inlet Node, !- Component 1 Inlet Node Name
  4344. CW Demand Outlet Node, !- Component 1 Outlet Node Name
  4345. Passive; !- Component 1 Branch Control Type
  4346.  
  4347. Branch,
  4348. Condenser Water Loop Supply Inlet Branch, !- Name
  4349. autosize, !- Maximum Flow Rate {m3/s}
  4350. , !- Pressure Drop Curve Name
  4351. Pump:VariableSpeed, !- Component 1 Object Type
  4352. CndSys Supply Pump, !- Component 1 Name
  4353. CndSys Supply Inlet Node,!- Component 1 Inlet Node Name
  4354. CndSys Supply Pump Oulet Node, !- Component 1 Outlet Node Name
  4355. Passive; !- Component 1 Branch Control Type
  4356.  
  4357. Branch,
  4358. Condenser Water Loop Supply Branch 1, !- Name
  4359. autosize, !- Maximum Flow Rate {m3/s}
  4360. , !- Pressure Drop Curve Name
  4361. CoolingTower:SingleSpeed,!- Component 1 Object Type
  4362. Cooling Tower Single Speed 1, !- Component 1 Name
  4363. CndSys CoolTwr Inlet Node, !- Component 1 Inlet Node Name
  4364. CndSys CoolTwr Outlet Node, !- Component 1 Outlet Node Name
  4365. Passive; !- Component 1 Branch Control Type
  4366.  
  4367. Branch,
  4368. Condenser Water Loop Supply Branch 2, !- Name
  4369. autosize, !- Maximum Flow Rate {m3/s}
  4370. , !- Pressure Drop Curve Name
  4371. Pipe:Adiabatic, !- Component 1 Object Type
  4372. CndSys Supply Bypass Pipe, !- Component 1 Name
  4373. CndSys Supply Bypass Pipe Inlet Node, !- Component 1 Inlet Node Name
  4374. CndSys Supply Bypass Pipe Outlet Node, !- Component 1 Outlet Node Name
  4375. Passive; !- Component 1 Branch Control Type
  4376.  
  4377. Branch,
  4378. Condenser Water Loop Supply Outlet Branch, !- Name
  4379. autosize, !- Maximum Flow Rate {m3/s}
  4380. , !- Pressure Drop Curve Name
  4381. Pipe:Adiabatic, !- Component 1 Object Type
  4382. CndSys Supply Outlet Pipe, !- Component 1 Name
  4383. CndSys Supply Outlet Pipe Inlet Node, !- Component 1 Inlet Node Name
  4384. CndSys Supply Outlet Node, !- Component 1 Outlet Node Name
  4385. Passive; !- Component 1 Branch Control Type
  4386.  
  4387. Branch,
  4388. Condenser Water Loop Demand Inlet Branch, !- Name
  4389. autosize, !- Maximum Flow Rate {m3/s}
  4390. , !- Pressure Drop Curve Name
  4391. Pipe:Adiabatic, !- Component 1 Object Type
  4392. CndSys Demand Inlet Pipe,!- Component 1 Name
  4393. CndSys Demand Inlet Node,!- Component 1 Inlet Node Name
  4394. CndSys Demand Inlet Pipe Outlet Node, !- Component 1 Outlet Node Name
  4395. Passive; !- Component 1 Branch Control Type
  4396.  
  4397. Branch,
  4398. Condenser Water Loop Demand Branch 1, !- Name
  4399. autosize, !- Maximum Flow Rate {m3/s}
  4400. , !- Pressure Drop Curve Name
  4401. Chiller:Electric:EIR, !- Component 1 Object Type
  4402. Chiller Electric EIR 1, !- Component 1 Name
  4403. CndSys Demand Chiller Inlet Node, !- Component 1 Inlet Node Name
  4404. CndSys Demand Chiller Outlet Node, !- Component 1 Outlet Node Name
  4405. Passive; !- Component 1 Branch Control Type
  4406.  
  4407. Branch,
  4408. Condenser Water Loop Demand Bypass Branch, !- Name
  4409. autosize, !- Maximum Flow Rate {m3/s}
  4410. , !- Pressure Drop Curve Name
  4411. Pipe:Adiabatic, !- Component 1 Object Type
  4412. CndSys Demand Bypass Pipe, !- Component 1 Name
  4413. CndSys Demand Bypass Pipe Inlet Node, !- Component 1 Inlet Node Name
  4414. CndSys Demand Bypass Pipe Outlet Node, !- Component 1 Outlet Node Name
  4415. Bypass; !- Component 1 Branch Control Type
  4416.  
  4417. Branch,
  4418. Condenser Water Loop Demand Outlet Branch, !- Name
  4419. autosize, !- Maximum Flow Rate {m3/s}
  4420. , !- Pressure Drop Curve Name
  4421. Pipe:Adiabatic, !- Component 1 Object Type
  4422. CndSys Demand Outlet Pipe, !- Component 1 Name
  4423. CndSys Demand Outlet Pipe Inlet Node, !- Component 1 Inlet Node Name
  4424. CndSys Demand Outlet Node, !- Component 1 Outlet Node Name
  4425. Passive; !- Component 1 Branch Control Type
  4426.  
  4427. Branch,
  4428. Hot Water Loop Supply Inlet Branch, !- Name
  4429. , !- Maximum Flow Rate {m3/s}
  4430. , !- Pressure Drop Curve Name
  4431. Pump:VariableSpeed, !- Component 1 Object Type
  4432. HeatSys1 Supply Pump, !- Component 1 Name
  4433. HeatSys1 Supply Inlet Node, !- Component 1 Inlet Node Name
  4434. HeatSys1 Pump Outlet Node, !- Component 1 Outlet Node Name
  4435. Passive; !- Component 1 Branch Control Type
  4436.  
  4437. Branch,
  4438. Hot Water Loop Supply Branch 1, !- Name
  4439. , !- Maximum Flow Rate {m3/s}
  4440. , !- Pressure Drop Curve Name
  4441. Boiler:HotWater, !- Component 1 Object Type
  4442. Boiler Hot Water 1, !- Component 1 Name
  4443. HeatSys1 Boiler Inlet Node, !- Component 1 Inlet Node Name
  4444. HeatSys1 Boiler Outlet Node, !- Component 1 Outlet Node Name
  4445. Passive; !- Component 1 Branch Control Type
  4446.  
  4447. Branch,
  4448. Hot Water Loop Supply Branch 2, !- Name
  4449. , !- Maximum Flow Rate {m3/s}
  4450. , !- Pressure Drop Curve Name
  4451. Pipe:Adiabatic, !- Component 1 Object Type
  4452. HeatSys1 Supply Bypass Pipe, !- Component 1 Name
  4453. HeatSys1 Supply Bypass Pipe Inlet Node, !- Component 1 Inlet Node Name
  4454. HeatSys1 Supply Bypass Pipe Outlet Node, !- Component 1 Outlet Node Name
  4455. Passive; !- Component 1 Branch Control Type
  4456.  
  4457. Branch,
  4458. Hot Water Loop Supply Outlet Branch, !- Name
  4459. , !- Maximum Flow Rate {m3/s}
  4460. , !- Pressure Drop Curve Name
  4461. Pipe:Adiabatic, !- Component 1 Object Type
  4462. HeatSys1 Supply Outlet Pipe, !- Component 1 Name
  4463. HeatSys1 Supply Outlet Node, !- Component 1 Inlet Node Name
  4464. HeatSys1 Supply Outlet Node, !- Component 1 Outlet Node Name
  4465. Passive; !- Component 1 Branch Control Type
  4466.  
  4467. Branch,
  4468. Hot Water Loop Demand Inlet Branch, !- Name
  4469. , !- Maximum Flow Rate {m3/s}
  4470. , !- Pressure Drop Curve Name
  4471. Pump:VariableSpeed, !- Component 1 Object Type
  4472. HeatSys1 Demand Pump, !- Component 1 Name
  4473. HeatSys1 Demand Inlet Node, !- Component 1 Inlet Node Name
  4474. HeatSys1 D_Pump Outlet Node, !- Component 1 Outlet Node Name
  4475. Passive; !- Component 1 Branch Control Type
  4476.  
  4477. Branch,
  4478. Hot Water Loop Demand Branch 1, !- Name
  4479. , !- Maximum Flow Rate {m3/s}
  4480. , !- Pressure Drop Curve Name
  4481. Pipe:Adiabatic, !- Component 1 Object Type
  4482. Pipe Adiabatic 2, !- Component 1 Name
  4483. Node 16, !- Component 1 Inlet Node Name
  4484. Node 21, !- Component 1 Outlet Node Name
  4485. Passive; !- Component 1 Branch Control Type
  4486.  
  4487. Branch,
  4488. Hot Water Loop Demand Branch 2, !- Name
  4489. , !- Maximum Flow Rate {m3/s}
  4490. , !- Pressure Drop Curve Name
  4491. Coil:Heating:Water, !- Component 1 Object Type
  4492. Coil Heating Water 1, !- Component 1 Name
  4493. HC1 Water Inlet Node, !- Component 1 Inlet Node Name
  4494. HC1 Water Outlet Node, !- Component 1 Outlet Node Name
  4495. Passive; !- Component 1 Branch Control Type
  4496.  
  4497. Branch,
  4498. Hot Water Loop Demand Branch 3, !- Name
  4499. , !- Maximum Flow Rate {m3/s}
  4500. , !- Pressure Drop Curve Name
  4501. Coil:Heating:Water, !- Component 1 Object Type
  4502. Coil Heating Water 2, !- Component 1 Name
  4503. Node 42, !- Component 1 Inlet Node Name
  4504. Node 43, !- Component 1 Outlet Node Name
  4505. Passive; !- Component 1 Branch Control Type
  4506.  
  4507. Branch,
  4508. Hot Water Loop Demand Branch 4, !- Name
  4509. , !- Maximum Flow Rate {m3/s}
  4510. , !- Pressure Drop Curve Name
  4511. Coil:Heating:Water, !- Component 1 Object Type
  4512. Coil Heating Water 3, !- Component 1 Name
  4513. Node 63, !- Component 1 Inlet Node Name
  4514. Node 64, !- Component 1 Outlet Node Name
  4515. Passive; !- Component 1 Branch Control Type
  4516.  
  4517. Branch,
  4518. Hot Water Loop Demand Branch 5, !- Name
  4519. , !- Maximum Flow Rate {m3/s}
  4520. , !- Pressure Drop Curve Name
  4521. Coil:Heating:Water, !- Component 1 Object Type
  4522. Coil Heating Water 4, !- Component 1 Name
  4523. Node 68, !- Component 1 Inlet Node Name
  4524. Node 69, !- Component 1 Outlet Node Name
  4525. Passive; !- Component 1 Branch Control Type
  4526.  
  4527. Branch,
  4528. Hot Water Loop Demand Branch 6, !- Name
  4529. , !- Maximum Flow Rate {m3/s}
  4530. , !- Pressure Drop Curve Name
  4531. Coil:Heating:Water, !- Component 1 Object Type
  4532. Coil Heating Water 5, !- Component 1 Name
  4533. Node 73, !- Component 1 Inlet Node Name
  4534. Node 74, !- Component 1 Outlet Node Name
  4535. Passive; !- Component 1 Branch Control Type
  4536.  
  4537. Branch,
  4538. Hot Water Loop Demand Branch 7, !- Name
  4539. , !- Maximum Flow Rate {m3/s}
  4540. , !- Pressure Drop Curve Name
  4541. Coil:Heating:Water, !- Component 1 Object Type
  4542. Coil Heating Water 6, !- Component 1 Name
  4543. Node 78, !- Component 1 Inlet Node Name
  4544. Node 79, !- Component 1 Outlet Node Name
  4545. Passive; !- Component 1 Branch Control Type
  4546.  
  4547. Branch,
  4548. Hot Water Loop Demand Bypass Branch, !- Name
  4549. , !- Maximum Flow Rate {m3/s}
  4550. , !- Pressure Drop Curve Name
  4551. Pipe:Adiabatic, !- Component 1 Object Type
  4552. Hot Water Loop Demand Bypass Pipe, !- Component 1 Name
  4553. Hot Water Loop Demand Bypass Pipe Inlet Node, !- Component 1 Inlet Node Name
  4554. Hot Water Loop Demand Bypass Pipe Outlet Node, !- Component 1 Outlet Node Name
  4555. Bypass; !- Component 1 Branch Control Type
  4556.  
  4557. Branch,
  4558. Hot Water Loop Demand Outlet Branch, !- Name
  4559. , !- Maximum Flow Rate {m3/s}
  4560. , !- Pressure Drop Curve Name
  4561. Pipe:Adiabatic, !- Component 1 Object Type
  4562. Pipe Adiabatic 4, !- Component 1 Name
  4563. HeatSys1 Demand Outlet Pipe Inlet Node, !- Component 1 Inlet Node Name
  4564. HeatSys1 Demand Outlet Node, !- Component 1 Outlet Node Name
  4565. Passive; !- Component 1 Branch Control Type
  4566.  
  4567. Branch,
  4568. Sec CW Loop Supply Inlet Branch, !- Name
  4569. autosize, !- Maximum Flow Rate {m3/s}
  4570. , !- Pressure Drop Curve Name
  4571. Pump:VariableSpeed, !- Component 1 Object Type
  4572. Sec CW Supply Pump, !- Component 1 Name
  4573. Sec CW Supply Inlet Node,!- Component 1 Inlet Node Name
  4574. Sec CW Supply Pump Outlet Node, !- Component 1 Outlet Node Name
  4575. Passive; !- Component 1 Branch Control Type
  4576.  
  4577. Branch,
  4578. Sec CW Loop Supply TES Branch, !- Name
  4579. autosize, !- Maximum Flow Rate {m3/s}
  4580. , !- Pressure Drop Curve Name
  4581. ThermalStorage:ChilledWater:Stratified, !- Component 1 Object Type
  4582. TES Chilled Water Stratified, !- Component 1 Name
  4583. TES Discharge Inlet Node,!- Component 1 Inlet Node Name
  4584. TES Discharge Outlet Node, !- Component 1 Outlet Node Name
  4585. Passive; !- Component 1 Branch Control Type
  4586.  
  4587. Branch,
  4588. Sec CW Loop Supply Bypass Branch, !- Name
  4589. autosize, !- Maximum Flow Rate {m3/s}
  4590. , !- Pressure Drop Curve Name
  4591. Pipe:Adiabatic, !- Component 1 Object Type
  4592. Sec CW Supply Bypass Pipe, !- Component 1 Name
  4593. Sec CW Supply Bypass Inlet Node, !- Component 1 Inlet Node Name
  4594. Sec CW Supply Bypass Outlet Node, !- Component 1 Outlet Node Name
  4595. Passive; !- Component 1 Branch Control Type
  4596.  
  4597. Branch,
  4598. Sec CW Loop Supply Outlet Branch, !- Name
  4599. autosize, !- Maximum Flow Rate {m3/s}
  4600. , !- Pressure Drop Curve Name
  4601. Pipe:Adiabatic, !- Component 1 Object Type
  4602. Sec CW Supply Outlet Pipe, !- Component 1 Name
  4603. Sec CW Supply Outlet Pipe Inlet Node, !- Component 1 Inlet Node Name
  4604. Sec CW Supply Outlet Node, !- Component 1 Outlet Node Name
  4605. Passive; !- Component 1 Branch Control Type
  4606.  
  4607. Branch,
  4608. Sec CW Loop Demand Inlet Branch, !- Name
  4609. autosize, !- Maximum Flow Rate {m3/s}
  4610. , !- Pressure Drop Curve Name
  4611. Pipe:Adiabatic, !- Component 1 Object Type
  4612. Sec CW Demand Inlet Pipe,!- Component 1 Name
  4613. Sec CW Demand Inlet Node,!- Component 1 Inlet Node Name
  4614. Sec CW Demand Inlet Pipe Outlet Node, !- Component 1 Outlet Node Name
  4615. Passive; !- Component 1 Branch Control Type
  4616.  
  4617. Branch,
  4618. Sec CW Loop Demand Load Branch, !- Name
  4619. autosize, !- Maximum Flow Rate {m3/s}
  4620. , !- Pressure Drop Curve Name
  4621. Coil:Cooling:Water, !- Component 1 Object Type
  4622. Coil Cooling Water 1, !- Component 1 Name
  4623. CC1 Inlet Node, !- Component 1 Inlet Node Name
  4624. CC1 Outlet Node, !- Component 1 Outlet Node Name
  4625. Passive; !- Component 1 Branch Control Type
  4626.  
  4627. Branch,
  4628. Sec CW Loop Demand Bypass Branch, !- Name
  4629. autosize, !- Maximum Flow Rate {m3/s}
  4630. , !- Pressure Drop Curve Name
  4631. Pipe:Adiabatic, !- Component 1 Object Type
  4632. Sec CW Demand Bypass Pipe, !- Component 1 Name
  4633. Sec CW Demand Bypass Inlet Node, !- Component 1 Inlet Node Name
  4634. Sec CW Demand Bypass Outlet Node, !- Component 1 Outlet Node Name
  4635. Passive; !- Component 1 Branch Control Type
  4636.  
  4637. Branch,
  4638. Sec CW Loop Demand Outlet Branch, !- Name
  4639. autosize, !- Maximum Flow Rate {m3/s}
  4640. , !- Pressure Drop Curve Name
  4641. Pipe:Adiabatic, !- Component 1 Object Type
  4642. Sec CW Demand Outlet Pipe, !- Component 1 Name
  4643. Sec CW Demand Outlet Pipe Inlet Node, !- Component 1 Inlet Node Name
  4644. Sec CW Demand Outlet Node, !- Component 1 Outlet Node Name
  4645. Passive; !- Component 1 Branch Control Type
  4646.  
  4647.  
  4648. !- =========== ALL OBJECTS IN CLASS: BRANCHLIST ===========
  4649.  
  4650. BranchList,
  4651. Air Loop Supply Branches,!- Name
  4652. Air Loop Main Branch1; !- Branch 1 Name
  4653.  
  4654. BranchList,
  4655. Chilled Water Loop Supply Branches, !- Name
  4656. Chilled Water Loop Supply Inlet Branch, !- Branch 1 Name
  4657. Chilled Water Loop Chiller Branch 1, !- Branch 2 Name
  4658. Chilled Water Loop Supply Bypass Branch, !- Branch 3 Name
  4659. Chilled Water Loop Supply Outlet Branch; !- Branch 4 Name
  4660.  
  4661. BranchList,
  4662. Chilled Water Loop Demand Branches, !- Name
  4663. Chilled Water Loop Demand Inlet Branch, !- Branch 1 Name
  4664. CW Loop Demand TES Branch 1, !- Branch 2 Name
  4665. Chilled Water Loop Demand Bypass Branch, !- Branch 3 Name
  4666. Chilled Water Loop Demand Outlet Branch; !- Branch 4 Name
  4667.  
  4668. BranchList,
  4669. Condenser Water Loop Supply Branches, !- Name
  4670. Condenser Water Loop Supply Inlet Branch, !- Branch 1 Name
  4671. Condenser Water Loop Supply Branch 1, !- Branch 2 Name
  4672. Condenser Water Loop Supply Branch 2, !- Branch 3 Name
  4673. Condenser Water Loop Supply Outlet Branch; !- Branch 4 Name
  4674.  
  4675. BranchList,
  4676. Condenser Water Loop Demand Branches, !- Name
  4677. Condenser Water Loop Demand Inlet Branch, !- Branch 1 Name
  4678. Condenser Water Loop Demand Branch 1, !- Branch 2 Name
  4679. Condenser Water Loop Demand Bypass Branch, !- Branch 3 Name
  4680. Condenser Water Loop Demand Outlet Branch; !- Branch 4 Name
  4681.  
  4682. BranchList,
  4683. Hot Water Loop Supply Branches, !- Name
  4684. Hot Water Loop Supply Inlet Branch, !- Branch 1 Name
  4685. Hot Water Loop Supply Branch 1, !- Branch 2 Name
  4686. Hot Water Loop Supply Branch 2, !- Branch 3 Name
  4687. Hot Water Loop Supply Outlet Branch; !- Branch 4 Name
  4688.  
  4689. BranchList,
  4690. Hot Water Loop Demand Branches, !- Name
  4691. Hot Water Loop Demand Inlet Branch, !- Branch 1 Name
  4692. Hot Water Loop Demand Branch 1, !- Branch 2 Name
  4693. Hot Water Loop Demand Branch 2, !- Branch 3 Name
  4694. Hot Water Loop Demand Branch 3, !- Branch 4 Name
  4695. Hot Water Loop Demand Branch 4, !- Branch 5 Name
  4696. Hot Water Loop Demand Branch 5, !- Branch 6 Name
  4697. Hot Water Loop Demand Branch 6, !- Branch 7 Name
  4698. Hot Water Loop Demand Branch 7, !- Branch 8 Name
  4699. Hot Water Loop Demand Bypass Branch, !- Branch 9 Name
  4700. Hot Water Loop Demand Outlet Branch; !- Branch 10 Name
  4701.  
  4702. BranchList,
  4703. Sec CW Supply Branches, !- Name
  4704. Sec CW Loop Supply Inlet Branch, !- Branch 1 Name
  4705. Sec CW Loop Supply TES Branch, !- Branch 2 Name
  4706. Sec CW Loop Supply Bypass Branch, !- Branch 3 Name
  4707. Sec CW Loop Supply Outlet Branch; !- Branch 4 Name
  4708.  
  4709. BranchList,
  4710. Sec CW Demand Branches, !- Name
  4711. Sec CW Loop Demand Inlet Branch, !- Branch 1 Name
  4712. Sec CW Loop Demand Load Branch, !- Branch 2 Name
  4713. Sec CW Loop Demand Bypass Branch, !- Branch 3 Name
  4714. Sec CW Loop Demand Outlet Branch; !- Branch 4 Name
  4715.  
  4716.  
  4717. !- =========== ALL OBJECTS IN CLASS: CONNECTOR:SPLITTER ===========
  4718.  
  4719. Connector:Splitter,
  4720. Chilled Water Loop Supply Splitter, !- Name
  4721. Chilled Water Loop Supply Inlet Branch, !- Inlet Branch Name
  4722. Chilled Water Loop Chiller Branch 1, !- Outlet Branch 1 Name
  4723. Chilled Water Loop Supply Bypass Branch; !- Outlet Branch 2 Name
  4724.  
  4725. Connector:Splitter,
  4726. Chilled Water Loop Demand Splitter, !- Name
  4727. Chilled Water Loop Demand Inlet Branch, !- Inlet Branch Name
  4728. CW Loop Demand TES Branch 1, !- Outlet Branch 1 Name
  4729. Chilled Water Loop Demand Bypass Branch; !- Outlet Branch 2 Name
  4730.  
  4731. Connector:Splitter,
  4732. Condenser Water Loop Supply Splitter, !- Name
  4733. Condenser Water Loop Supply Inlet Branch, !- Inlet Branch Name
  4734. Condenser Water Loop Supply Branch 1, !- Outlet Branch 1 Name
  4735. Condenser Water Loop Supply Branch 2; !- Outlet Branch 2 Name
  4736.  
  4737. Connector:Splitter,
  4738. Condenser Water Loop Demand Splitter, !- Name
  4739. Condenser Water Loop Demand Inlet Branch, !- Inlet Branch Name
  4740. Condenser Water Loop Demand Branch 1, !- Outlet Branch 1 Name
  4741. Condenser Water Loop Demand Bypass Branch; !- Outlet Branch 2 Name
  4742.  
  4743. Connector:Splitter,
  4744. Hot Water Loop Supply Splitter, !- Name
  4745. Hot Water Loop Supply Inlet Branch, !- Inlet Branch Name
  4746. Hot Water Loop Supply Branch 1, !- Outlet Branch 1 Name
  4747. Hot Water Loop Supply Branch 2; !- Outlet Branch 2 Name
  4748.  
  4749. Connector:Splitter,
  4750. Hot Water Loop Demand Splitter, !- Name
  4751. Hot Water Loop Demand Inlet Branch, !- Inlet Branch Name
  4752. Hot Water Loop Demand Branch 1, !- Outlet Branch 1 Name
  4753. Hot Water Loop Demand Branch 2, !- Outlet Branch 2 Name
  4754. Hot Water Loop Demand Branch 3, !- Outlet Branch 3 Name
  4755. Hot Water Loop Demand Branch 4, !- Outlet Branch 4 Name
  4756. Hot Water Loop Demand Branch 5, !- Outlet Branch 5 Name
  4757. Hot Water Loop Demand Branch 6, !- Outlet Branch 6 Name
  4758. Hot Water Loop Demand Branch 7, !- Outlet Branch 7 Name
  4759. Hot Water Loop Demand Bypass Branch; !- Outlet Branch 8 Name
  4760.  
  4761. Connector:Splitter,
  4762. Sec CW Supply Splitter, !- Name
  4763. Sec CW Loop Supply Inlet Branch, !- Inlet Branch Name
  4764. Sec CW Loop Supply TES Branch, !- Outlet Branch 1 Name
  4765. Sec CW Loop Supply Bypass Branch; !- Outlet Branch 2 Name
  4766.  
  4767. Connector:Splitter,
  4768. Sec CW Demand Splitter, !- Name
  4769. Sec CW Loop Demand Inlet Branch, !- Inlet Branch Name
  4770. Sec CW Loop Demand Load Branch, !- Outlet Branch 1 Name
  4771. Sec CW Loop Demand Bypass Branch; !- Outlet Branch 2 Name
  4772.  
  4773.  
  4774. !- =========== ALL OBJECTS IN CLASS: CONNECTOR:MIXER ===========
  4775.  
  4776. Connector:Mixer,
  4777. Chilled Water Loop Supply Mixer, !- Name
  4778. Chilled Water Loop Supply Outlet Branch, !- Outlet Branch Name
  4779. Chilled Water Loop Chiller Branch 1, !- Inlet Branch 1 Name
  4780. Chilled Water Loop Supply Bypass Branch; !- Inlet Branch 2 Name
  4781.  
  4782. Connector:Mixer,
  4783. Chilled Water Loop Demand Mixer, !- Name
  4784. Chilled Water Loop Demand Outlet Branch, !- Outlet Branch Name
  4785. CW Loop Demand TES Branch 1, !- Inlet Branch 1 Name
  4786. Chilled Water Loop Demand Bypass Branch; !- Inlet Branch 2 Name
  4787.  
  4788. Connector:Mixer,
  4789. Condenser Water Loop Supply Mixer, !- Name
  4790. Condenser Water Loop Supply Outlet Branch, !- Outlet Branch Name
  4791. Condenser Water Loop Supply Branch 1, !- Inlet Branch 1 Name
  4792. Condenser Water Loop Supply Branch 2; !- Inlet Branch 2 Name
  4793.  
  4794. Connector:Mixer,
  4795. Condenser Water Loop Demand Mixer, !- Name
  4796. Condenser Water Loop Demand Outlet Branch, !- Outlet Branch Name
  4797. Condenser Water Loop Demand Branch 1, !- Inlet Branch 1 Name
  4798. Condenser Water Loop Demand Bypass Branch; !- Inlet Branch 2 Name
  4799.  
  4800. Connector:Mixer,
  4801. Hot Water Loop Supply Mixer, !- Name
  4802. Hot Water Loop Supply Outlet Branch, !- Outlet Branch Name
  4803. Hot Water Loop Supply Branch 1, !- Inlet Branch 1 Name
  4804. Hot Water Loop Supply Branch 2; !- Inlet Branch 2 Name
  4805.  
  4806. Connector:Mixer,
  4807. Hot Water Loop Demand Mixer, !- Name
  4808. Hot Water Loop Demand Outlet Branch, !- Outlet Branch Name
  4809. Hot Water Loop Demand Branch 1, !- Inlet Branch 1 Name
  4810. Hot Water Loop Demand Branch 2, !- Inlet Branch 2 Name
  4811. Hot Water Loop Demand Branch 3, !- Inlet Branch 3 Name
  4812. Hot Water Loop Demand Branch 4, !- Inlet Branch 4 Name
  4813. Hot Water Loop Demand Branch 5, !- Inlet Branch 5 Name
  4814. Hot Water Loop Demand Branch 6, !- Inlet Branch 6 Name
  4815. Hot Water Loop Demand Branch 7, !- Inlet Branch 7 Name
  4816. Hot Water Loop Demand Bypass Branch; !- Inlet Branch 8 Name
  4817.  
  4818. Connector:Mixer,
  4819. Sec CW Supply Mixer, !- Name
  4820. Sec CW Loop Supply Outlet Branch, !- Outlet Branch Name
  4821. Sec CW Loop Supply TES Branch, !- Inlet Branch 1 Name
  4822. Sec CW Loop Supply Bypass Branch; !- Inlet Branch 2 Name
  4823.  
  4824. Connector:Mixer,
  4825. Sec CW Demand Mixer, !- Name
  4826. Sec CW Loop Demand Outlet Branch, !- Outlet Branch Name
  4827. Sec CW Loop Demand Load Branch, !- Inlet Branch 1 Name
  4828. Sec CW Loop Demand Bypass Branch; !- Inlet Branch 2 Name
  4829.  
  4830.  
  4831. !- =========== ALL OBJECTS IN CLASS: CONNECTORLIST ===========
  4832.  
  4833. ConnectorList,
  4834. Chilled Water Loop Supply Connector List, !- Name
  4835. Connector:Splitter, !- Connector 1 Object Type
  4836. Chilled Water Loop Supply Splitter, !- Connector 1 Name
  4837. Connector:Mixer, !- Connector 2 Object Type
  4838. Chilled Water Loop Supply Mixer; !- Connector 2 Name
  4839.  
  4840. ConnectorList,
  4841. Chilled Water Loop Demand Connector List, !- Name
  4842. Connector:Splitter, !- Connector 1 Object Type
  4843. Chilled Water Loop Demand Splitter, !- Connector 1 Name
  4844. Connector:Mixer, !- Connector 2 Object Type
  4845. Chilled Water Loop Demand Mixer; !- Connector 2 Name
  4846.  
  4847. ConnectorList,
  4848. Condenser Water Loop Supply Connector List, !- Name
  4849. Connector:Splitter, !- Connector 1 Object Type
  4850. Condenser Water Loop Supply Splitter, !- Connector 1 Name
  4851. Connector:Mixer, !- Connector 2 Object Type
  4852. Condenser Water Loop Supply Mixer; !- Connector 2 Name
  4853.  
  4854. ConnectorList,
  4855. Condenser Water Loop Demand Connector List, !- Name
  4856. Connector:Splitter, !- Connector 1 Object Type
  4857. Condenser Water Loop Demand Splitter, !- Connector 1 Name
  4858. Connector:Mixer, !- Connector 2 Object Type
  4859. Condenser Water Loop Demand Mixer; !- Connector 2 Name
  4860.  
  4861. ConnectorList,
  4862. Hot Water Loop Supply Connector List, !- Name
  4863. Connector:Splitter, !- Connector 1 Object Type
  4864. Hot Water Loop Supply Splitter, !- Connector 1 Name
  4865. Connector:Mixer, !- Connector 2 Object Type
  4866. Hot Water Loop Supply Mixer; !- Connector 2 Name
  4867.  
  4868. ConnectorList,
  4869. Hot Water Loop Demand Connector List, !- Name
  4870. Connector:Splitter, !- Connector 1 Object Type
  4871. Hot Water Loop Demand Splitter, !- Connector 1 Name
  4872. Connector:Mixer, !- Connector 2 Object Type
  4873. Hot Water Loop Demand Mixer; !- Connector 2 Name
  4874.  
  4875. ConnectorList,
  4876. Sec CW Supply Connector List, !- Name
  4877. Connector:Splitter, !- Connector 1 Object Type
  4878. Sec CW Supply Splitter, !- Connector 1 Name
  4879. Connector:Mixer, !- Connector 2 Object Type
  4880. Sec CW Supply Mixer; !- Connector 2 Name
  4881.  
  4882. ConnectorList,
  4883. Sec CW Demand Connector List, !- Name
  4884. Connector:Splitter, !- Connector 1 Object Type
  4885. Sec CW Demand Splitter, !- Connector 1 Name
  4886. Connector:Mixer, !- Connector 2 Object Type
  4887. Sec CW Demand Mixer; !- Connector 2 Name
  4888.  
  4889.  
  4890. !- =========== ALL OBJECTS IN CLASS: NODELIST ===========
  4891.  
  4892. NodeList,
  4893. Core_ZN Thermal Zone Inlet Node List, !- Name
  4894. ZoneCore Return Air Node;!- Node 1 Name
  4895.  
  4896. NodeList,
  4897. Perimeter_ZN_1 Thermal Zone Inlet Node List, !- Name
  4898. P_ZN_1 Return Air Node; !- Node 1 Name
  4899.  
  4900. NodeList,
  4901. Perimeter_ZN_2 Thermal Zone Inlet Node List, !- Name
  4902. P_ZN_2 Return Air Node; !- Node 1 Name
  4903.  
  4904. NodeList,
  4905. Perimeter_ZN_3 Thermal Zone Inlet Node List, !- Name
  4906. P_ZN_3 Return Air Node; !- Node 1 Name
  4907.  
  4908. NodeList,
  4909. Perimeter_ZN_4 Thermal Zone Inlet Node List, !- Name
  4910. P_ZN_4 Return Air Node; !- Node 1 Name
  4911.  
  4912. NodeList,
  4913. VAV with Reheat Supply Outlet Nodes, !- Name
  4914. Air Outlet Node1; !- Node 1 Name
  4915.  
  4916. NodeList,
  4917. VAV with Reheat Demand Inlet Nodes, !- Name
  4918. Air Demand Inlet Node1; !- Node 1 Name
  4919.  
  4920. NodeList,
  4921. AHU OA Node List, !- Name
  4922. Outdoor Air Node; !- Node 1 Name
  4923.  
  4924.  
  4925. !- =========== ALL OBJECTS IN CLASS: OUTDOORAIR:NODELIST ===========
  4926.  
  4927. OutdoorAir:NodeList,
  4928. Outdoor Air Node; !- Node or NodeList Name 1
  4929.  
  4930.  
  4931. !- =========== ALL OBJECTS IN CLASS: PIPE:ADIABATIC ===========
  4932.  
  4933. Pipe:Adiabatic,
  4934. CW Supply Bypass Pipe, !- Name
  4935. CW Supply Bypass Inlet Node, !- Inlet Node Name
  4936. CW Supply Bypass Outlet Node; !- Outlet Node Name
  4937.  
  4938. Pipe:Adiabatic,
  4939. CW Supply Outlet Bypass Pipe, !- Name
  4940. CW Supply Outlet Pipe Inlet Node, !- Inlet Node Name
  4941. CW Supply Outlet Node; !- Outlet Node Name
  4942.  
  4943. Pipe:Adiabatic,
  4944. CW Demand Inlet Pipe, !- Name
  4945. CW Demand Inlet Node, !- Inlet Node Name
  4946. CW Demand inlet Pipe Outlet Node; !- Outlet Node Name
  4947.  
  4948. Pipe:Adiabatic,
  4949. Chilled Water Loop Demand Bypass Pipe, !- Name
  4950. Chilled Water Loop Demand Bypass Pipe Inlet Node, !- Inlet Node Name
  4951. Chilled Water Loop Demand Bypass Pipe Outlet Node; !- Outlet Node Name
  4952.  
  4953. Pipe:Adiabatic,
  4954. CW Demand Outlet Pipe, !- Name
  4955. CW Outlet Pipe Inlet Node, !- Inlet Node Name
  4956. CW Demand Outlet Node; !- Outlet Node Name
  4957.  
  4958. Pipe:Adiabatic,
  4959. CndSys Supply Bypass Pipe, !- Name
  4960. CndSys Supply Bypass Pipe Inlet Node, !- Inlet Node Name
  4961. CndSys Supply Bypass Pipe Outlet Node; !- Outlet Node Name
  4962.  
  4963. Pipe:Adiabatic,
  4964. CndSys Supply Outlet Pipe, !- Name
  4965. CndSys Supply Outlet Pipe Inlet Node, !- Inlet Node Name
  4966. CndSys Supply Outlet Node; !- Outlet Node Name
  4967.  
  4968. Pipe:Adiabatic,
  4969. CndSys Demand Inlet Pipe,!- Name
  4970. CndSys Demand Inlet Node,!- Inlet Node Name
  4971. CndSys Demand Inlet Pipe Outlet Node; !- Outlet Node Name
  4972.  
  4973. Pipe:Adiabatic,
  4974. CndSys Demand Bypass Pipe, !- Name
  4975. CndSys Demand Bypass Pipe Inlet Node, !- Inlet Node Name
  4976. CndSys Demand Bypass Pipe Outlet Node; !- Outlet Node Name
  4977.  
  4978. Pipe:Adiabatic,
  4979. CndSys Demand Outlet Pipe, !- Name
  4980. CndSys Demand Outlet Pipe Inlet Node, !- Inlet Node Name
  4981. CndSys Demand Outlet Node; !- Outlet Node Name
  4982.  
  4983. Pipe:Adiabatic,
  4984. HeatSys1 Supply Bypass Pipe, !- Name
  4985. HeatSys1 Supply Bypass Pipe Inlet Node, !- Inlet Node Name
  4986. HeatSys1 Supply Bypass Pipe Outlet Node; !- Outlet Node Name
  4987.  
  4988. Pipe:Adiabatic,
  4989. HeatSys1 Supply Outlet Pipe, !- Name
  4990. HeatSys1 Supply Outlet Pipe Inlet Node, !- Inlet Node Name
  4991. HeatSys1 Supply Outlet Node; !- Outlet Node Name
  4992.  
  4993. Pipe:Adiabatic,
  4994. Pipe Adiabatic 3, !- Name
  4995. Node 14, !- Inlet Node Name
  4996. Node 25; !- Outlet Node Name
  4997.  
  4998. Pipe:Adiabatic,
  4999. Pipe Adiabatic 2, !- Name
  5000. Node 16, !- Inlet Node Name
  5001. Node 21; !- Outlet Node Name
  5002.  
  5003. Pipe:Adiabatic,
  5004. Hot Water Loop Demand Bypass Pipe, !- Name
  5005. Hot Water Loop Demand Bypass Pipe Inlet Node, !- Inlet Node Name
  5006. Hot Water Loop Demand Bypass Pipe Outlet Node; !- Outlet Node Name
  5007.  
  5008. Pipe:Adiabatic,
  5009. Pipe Adiabatic 4, !- Name
  5010. Node 24, !- Inlet Node Name
  5011. Node 15; !- Outlet Node Name
  5012.  
  5013. Pipe:Adiabatic,
  5014. Sec CW Supply Bypass Pipe, !- Name
  5015. Sec CW Supply Bypass Inlet Node, !- Inlet Node Name
  5016. Sec CW Supply Bypass Outlet Node; !- Outlet Node Name
  5017.  
  5018. Pipe:Adiabatic,
  5019. Sec CW Supply Outlet Pipe, !- Name
  5020. Sec CW Supply Outlet Pipe Inlet Node, !- Inlet Node Name
  5021. Sec CW Supply Outlet Node; !- Outlet Node Name
  5022.  
  5023. Pipe:Adiabatic,
  5024. Sec CW Demand Inlet Pipe,!- Name
  5025. Sec CW Demand Inlet Node,!- Inlet Node Name
  5026. Sec CW Demand Inlet Pipe Outlet Node; !- Outlet Node Name
  5027.  
  5028. Pipe:Adiabatic,
  5029. Sec CW Demand Bypass Pipe, !- Name
  5030. Sec CW Demand Bypass Inlet Node, !- Inlet Node Name
  5031. Sec CW Demand Bypass Outlet Node; !- Outlet Node Name
  5032.  
  5033. Pipe:Adiabatic,
  5034. Sec CW Demand Outlet Pipe, !- Name
  5035. Sec CW Demand Outlet Pipe Inlet Node, !- Inlet Node Name
  5036. Sec CW Demand Outlet Node; !- Outlet Node Name
  5037.  
  5038.  
  5039. !- =========== ALL OBJECTS IN CLASS: PUMP:VARIABLESPEED ===========
  5040.  
  5041. Pump:VariableSpeed,
  5042. CW Supply Pump, !- Name
  5043. CW Supply Inlet Node, !- Inlet Node Name
  5044. CW Supply Pump Outlet Node, !- Outlet Node Name
  5045. Autosize, !- Design Maximum Flow Rate {m3/s}
  5046. 179352, !- Design Pump Head {Pa}
  5047. Autosize, !- Design Power Consumption {W}
  5048. 0.9, !- Motor Efficiency
  5049. 0, !- Fraction of Motor Inefficiencies to Fluid Stream
  5050. 0, !- Coefficient 1 of the Part Load Performance Curve
  5051. 1, !- Coefficient 2 of the Part Load Performance Curve
  5052. 0, !- Coefficient 3 of the Part Load Performance Curve
  5053. 0, !- Coefficient 4 of the Part Load Performance Curve
  5054. 0, !- Design Minimum Flow Rate {m3/s}
  5055. Intermittent; !- Pump Control Type
  5056.  
  5057. Pump:VariableSpeed,
  5058. CndSys Supply Pump, !- Name
  5059. CndSys Supply Inlet Node,!- Inlet Node Name
  5060. CndSys Supply Pump Oulet Node, !- Outlet Node Name
  5061. Autosize, !- Design Maximum Flow Rate {m3/s}
  5062. 179352, !- Design Pump Head {Pa}
  5063. Autosize, !- Design Power Consumption {W}
  5064. 0.9, !- Motor Efficiency
  5065. 0, !- Fraction of Motor Inefficiencies to Fluid Stream
  5066. 0, !- Coefficient 1 of the Part Load Performance Curve
  5067. 1, !- Coefficient 2 of the Part Load Performance Curve
  5068. 0, !- Coefficient 3 of the Part Load Performance Curve
  5069. 0, !- Coefficient 4 of the Part Load Performance Curve
  5070. 0, !- Design Minimum Flow Rate {m3/s}
  5071. Intermittent; !- Pump Control Type
  5072.  
  5073. Pump:VariableSpeed,
  5074. HeatSys1 Supply Pump, !- Name
  5075. HeatSys1 Supply Inlet Node, !- Inlet Node Name
  5076. HeatSys1 Pump Outlet Node, !- Outlet Node Name
  5077. Autosize, !- Design Maximum Flow Rate {m3/s}
  5078. 179352, !- Design Pump Head {Pa}
  5079. Autosize, !- Design Power Consumption {W}
  5080. 0.9, !- Motor Efficiency
  5081. 0, !- Fraction of Motor Inefficiencies to Fluid Stream
  5082. 0, !- Coefficient 1 of the Part Load Performance Curve
  5083. 1, !- Coefficient 2 of the Part Load Performance Curve
  5084. 0, !- Coefficient 3 of the Part Load Performance Curve
  5085. 0, !- Coefficient 4 of the Part Load Performance Curve
  5086. 0, !- Design Minimum Flow Rate {m3/s}
  5087. Intermittent; !- Pump Control Type
  5088.  
  5089. Pump:VariableSpeed,
  5090. HeatSys1 Demand Pump, !- Name
  5091. HeatSys1 Demand Inlet Node, !- Inlet Node Name
  5092. HeatSys1 D_Pump Outlet Node, !- Outlet Node Name
  5093. Autosize, !- Design Maximum Flow Rate {m3/s}
  5094. 179352, !- Design Pump Head {Pa}
  5095. Autosize, !- Design Power Consumption {W}
  5096. 0.9, !- Motor Efficiency
  5097. 0, !- Fraction of Motor Inefficiencies to Fluid Stream
  5098. 0, !- Coefficient 1 of the Part Load Performance Curve
  5099. 1, !- Coefficient 2 of the Part Load Performance Curve
  5100. 0, !- Coefficient 3 of the Part Load Performance Curve
  5101. 0, !- Coefficient 4 of the Part Load Performance Curve
  5102. 0, !- Design Minimum Flow Rate {m3/s}
  5103. Intermittent; !- Pump Control Type
  5104.  
  5105. Pump:VariableSpeed,
  5106. Sec CW Supply Pump, !- Name
  5107. Sec CW Supply Inlet Node,!- Inlet Node Name
  5108. Sec CW Supply Pump Outlet Node, !- Outlet Node Name
  5109. Autosize, !- Design Maximum Flow Rate {m3/s}
  5110. 179352, !- Design Pump Head {Pa}
  5111. Autosize, !- Design Power Consumption {W}
  5112. 0.9, !- Motor Efficiency
  5113. 0, !- Fraction of Motor Inefficiencies to Fluid Stream
  5114. 0, !- Coefficient 1 of the Part Load Performance Curve
  5115. 1, !- Coefficient 2 of the Part Load Performance Curve
  5116. 0, !- Coefficient 3 of the Part Load Performance Curve
  5117. 0, !- Coefficient 4 of the Part Load Performance Curve
  5118. 0, !- Design Minimum Flow Rate {m3/s}
  5119. Intermittent; !- Pump Control Type
  5120.  
  5121.  
  5122. !- =========== ALL OBJECTS IN CLASS: BOILER:HOTWATER ===========
  5123.  
  5124. Boiler:HotWater,
  5125. Boiler Hot Water 1, !- Name
  5126. Electricity, !- Fuel Type
  5127. Autosize, !- Nominal Capacity {W}
  5128. 0.8, !- Nominal Thermal Efficiency
  5129. LeavingBoiler, !- Efficiency Curve Temperature Evaluation Variable
  5130. Boiler Efficiency, !- Normalized Boiler Efficiency Curve Name
  5131. 82, !- Design Water Outlet Temperature {C}
  5132. Autosize, !- Design Water Flow Rate {m3/s}
  5133. 0, !- Minimum Part Load Ratio
  5134. 1, !- Maximum Part Load Ratio
  5135. 1, !- Optimum Part Load Ratio
  5136. HeatSys1 Boiler Inlet Node, !- Boiler Water Inlet Node Name
  5137. HeatSys1 Boiler Outlet Node, !- Boiler Water Outlet Node Name
  5138. 99, !- Water Outlet Upper Temperature Limit {C}
  5139. ConstantFlow, !- Boiler Flow Mode
  5140. 0, !- Parasitic Electric Load {W}
  5141. 1; !- Sizing Factor
  5142.  
  5143.  
  5144. !- =========== ALL OBJECTS IN CLASS: CHILLER:ELECTRIC:EIR ===========
  5145.  
  5146. Chiller:Electric:EIR,
  5147. Chiller Electric EIR 1, !- Name
  5148. Autosize, !- Reference Capacity {W}
  5149. 5.5, !- Reference COP {W/W}
  5150. 6.67, !- Reference Leaving Chilled Water Temperature {C}
  5151. 29.4, !- Reference Entering Condenser Fluid Temperature {C}
  5152. Autosize, !- Reference Chilled Water Flow Rate {m3/s}
  5153. Autosize, !- Reference Condenser Fluid Flow Rate {m3/s}
  5154. Curve Biquadratic 1, !- Cooling Capacity Function of Temperature Curve Name
  5155. Curve Biquadratic 2, !- Electric Input to Cooling Output Ratio Function of Temperature Curve Name
  5156. Curve Quadratic 1, !- Electric Input to Cooling Output Ratio Function of Part Load Ratio Curve Name
  5157. 0.1, !- Minimum Part Load Ratio
  5158. 1, !- Maximum Part Load Ratio
  5159. 1, !- Optimum Part Load Ratio
  5160. 0.2, !- Minimum Unloading Ratio
  5161. Chiller Inlet Node, !- Chilled Water Inlet Node Name
  5162. Chiller Outlet Node, !- Chilled Water Outlet Node Name
  5163. Chiller Condenser Inlet Node, !- Condenser Inlet Node Name
  5164. Chiller Condenser Outlet Node, !- Condenser Outlet Node Name
  5165. WaterCooled, !- Condenser Type
  5166. 0, !- Condenser Fan Power Ratio {W/W}
  5167. 1, !- Fraction of Compressor Electric Consumption Rejected by Condenser
  5168. 2, !- Leaving Chilled Water Lower Temperature Limit {C}
  5169. NotModulated, !- Chiller Flow Mode
  5170. , !- Design Heat Recovery Water Flow Rate {m3/s}
  5171. , !- Heat Recovery Inlet Node Name
  5172. , !- Heat Recovery Outlet Node Name
  5173. 1; !- Sizing Factor
  5174.  
  5175.  
  5176. !- =========== ALL OBJECTS IN CLASS: COOLINGTOWER:SINGLESPEED ===========
  5177.  
  5178. CoolingTower:SingleSpeed,
  5179. Cooling Tower Single Speed 1, !- Name
  5180. CndSys CoolTwr Inlet Node, !- Water Inlet Node Name
  5181. CndSys CoolTwr Outlet Node, !- Water Outlet Node Name
  5182. Autosize, !- Design Water Flow Rate {m3/s}
  5183. Autosize, !- Design Air Flow Rate {m3/s}
  5184. Autosize, !- Design Fan Power {W}
  5185. Autosize, !- Design U-Factor Times Area Value {W/K}
  5186. Autosize, !- Free Convection Air Flow Rate {m3/s}
  5187. , !- Free Convection Air Flow Rate Sizing Factor
  5188. Autosize, !- Free Convection U-Factor Times Area Value {W/K}
  5189. , !- Free Convection U-Factor Times Area Value Sizing Factor
  5190. UFactorTimesAreaAndDesignWaterFlowRate, !- Performance Input Method
  5191. , !- Heat Rejection Capacity and Nominal Capacity Sizing Ratio
  5192. , !- Nominal Capacity {W}
  5193. 0, !- Free Convection Capacity {W}
  5194. , !- Free Convection Nominal Capacity Sizing Factor
  5195. 0, !- Basin Heater Capacity {W/K}
  5196. 2, !- Basin Heater Setpoint Temperature {C}
  5197. , !- Basin Heater Operating Schedule Name
  5198. LossFactor, !- Evaporation Loss Mode
  5199. 0.2, !- Evaporation Loss Factor {percent/K}
  5200. 0.008, !- Drift Loss Percent {percent}
  5201. ConcentrationRatio, !- Blowdown Calculation Mode
  5202. 3, !- Blowdown Concentration Ratio
  5203. , !- Blowdown Makeup Water Usage Schedule Name
  5204. , !- Supply Water Storage Tank Name
  5205. , !- Outdoor Air Inlet Node Name
  5206. FanCycling, !- Capacity Control
  5207. 1, !- Number of Cells
  5208. MinimalCell, !- Cell Control
  5209. 0.33, !- Cell Minimum Water Flow Rate Fraction
  5210. 2.5, !- Cell Maximum Water Flow Rate Fraction
  5211. 1; !- Sizing Factor
  5212.  
  5213.  
  5214. !- =========== ALL OBJECTS IN CLASS: THERMALSTORAGE:CHILLEDWATER:STRATIFIED ===========
  5215.  
  5216. ThermalStorage:ChilledWater:Stratified,
  5217. TES Chilled Water Stratified, !- Name
  5218. 4, !- Tank Volume {m3}
  5219. 2, !- Tank Height {m}
  5220. VerticalCylinder, !- Tank Shape
  5221. , !- Tank Perimeter {m}
  5222. CW-Tank-Temp-Schedule, !- Setpoint Temperature Schedule Name
  5223. 3.5, !- Deadband Temperature Difference {deltaC}
  5224. 1.4, !- Temperature Sensor Height {m}
  5225. 1, !- Minimum Temperature Limit {C}
  5226. 2500, !- Nominal Cooling Capacity {W}
  5227. Zone, !- Ambient Temperature Indicator
  5228. , !- Ambient Temperature Schedule Name
  5229. Core_ZN Thermal Zone, !- Ambient Temperature Zone Name
  5230. , !- Ambient Temperature Outdoor Air Node Name
  5231. 4.2, !- Uniform Skin Loss Coefficient per Unit Area to Ambient Temperature {W/m2-K}
  5232. TES Discharge Inlet Node,!- Use Side Inlet Node Name
  5233. TES Discharge Outlet Node, !- Use Side Outlet Node Name
  5234. 1, !- Use Side Heat Transfer Effectiveness
  5235. Always On Discrete, !- Use Side Availability Schedule Name
  5236. 1.85, !- Use Side Inlet Height {m}
  5237. 0.15, !- Use Side Outlet Height {m}
  5238. autosize, !- Use Side Design Flow Rate {m3/s}
  5239. TES Inlet Node, !- Source Side Inlet Node Name
  5240. TES Outlet Node, !- Source Side Outlet Node Name
  5241. 1, !- Source Side Heat Transfer Effectiveness
  5242. TES Charge Schedule, !- Source Side Availability Schedule Name
  5243. 0.15, !- Source Side Inlet Height {m}
  5244. 1.85, !- Source Side Outlet Height {m}
  5245. autosize, !- Source Side Design Flow Rate {m3/s}
  5246. 2, !- Tank Recovery Time {hr}
  5247. Seeking, !- Inlet Mode
  5248. 6, !- Number of Nodes
  5249. 0; !- Additional Destratification Conductivity {W/m-K}
  5250.  
  5251.  
  5252. !- =========== ALL OBJECTS IN CLASS: PLANTLOOP ===========
  5253.  
  5254. PlantLoop,
  5255. Chilled Water Loop, !- Name
  5256. Water, !- Fluid Type
  5257. , !- User Defined Fluid Type
  5258. Chilled Water Loop Operation Schemes, !- Plant Equipment Operation Scheme Name
  5259. CW Supply Outlet Node, !- Loop Temperature Setpoint Node Name
  5260. 98, !- Maximum Loop Temperature {C}
  5261. 1, !- Minimum Loop Temperature {C}
  5262. Autosize, !- Maximum Loop Flow Rate {m3/s}
  5263. 0, !- Minimum Loop Flow Rate {m3/s}
  5264. Autocalculate, !- Plant Loop Volume {m3}
  5265. CW Supply Inlet Node, !- Plant Side Inlet Node Name
  5266. CW Supply Outlet Node, !- Plant Side Outlet Node Name
  5267. Chilled Water Loop Supply Branches, !- Plant Side Branch List Name
  5268. Chilled Water Loop Supply Connector List, !- Plant Side Connector List Name
  5269. CW Demand Inlet Node, !- Demand Side Inlet Node Name
  5270. CW Demand Outlet Node, !- Demand Side Outlet Node Name
  5271. Chilled Water Loop Demand Branches, !- Demand Side Branch List Name
  5272. Chilled Water Loop Demand Connector List, !- Demand Side Connector List Name
  5273. Optimal, !- Load Distribution Scheme
  5274. , !- Availability Manager List Name
  5275. SingleSetpoint; !- Plant Loop Demand Calculation Scheme
  5276.  
  5277. PlantLoop,
  5278. Hot Water Loop, !- Name
  5279. Water, !- Fluid Type
  5280. , !- User Defined Fluid Type
  5281. Hot Water Loop Operation Schemes, !- Plant Equipment Operation Scheme Name
  5282. HeatSys1 Supply Outlet Node, !- Loop Temperature Setpoint Node Name
  5283. 98, !- Maximum Loop Temperature {C}
  5284. 1, !- Minimum Loop Temperature {C}
  5285. Autosize, !- Maximum Loop Flow Rate {m3/s}
  5286. 0, !- Minimum Loop Flow Rate {m3/s}
  5287. Autocalculate, !- Plant Loop Volume {m3}
  5288. HeatSys1 Supply Inlet Node, !- Plant Side Inlet Node Name
  5289. HeatSys1 Supply Outlet Node, !- Plant Side Outlet Node Name
  5290. Hot Water Loop Supply Branches, !- Plant Side Branch List Name
  5291. Hot Water Loop Supply Connector List, !- Plant Side Connector List Name
  5292. HeatSys1 Demand Inlet Node, !- Demand Side Inlet Node Name
  5293. HeatSys1 Demand Outlet Node, !- Demand Side Outlet Node Name
  5294. Hot Water Loop Demand Branches, !- Demand Side Branch List Name
  5295. Hot Water Loop Demand Connector List, !- Demand Side Connector List Name
  5296. Optimal; !- Load Distribution Scheme
  5297.  
  5298. PlantLoop,
  5299. Sec CW Loop, !- Name
  5300. Water, !- Fluid Type
  5301. , !- User Defined Fluid Type
  5302. Sec CW Loop Operation Schemes, !- Plant Equipment Operation Scheme Name
  5303. Sec CW Supply Outlet Node, !- Loop Temperature Setpoint Node Name
  5304. 98, !- Maximum Loop Temperature {C}
  5305. 1, !- Minimum Loop Temperature {C}
  5306. Autosize, !- Maximum Loop Flow Rate {m3/s}
  5307. 0, !- Minimum Loop Flow Rate {m3/s}
  5308. Autocalculate, !- Plant Loop Volume {m3}
  5309. Sec CW Supply Inlet Node,!- Plant Side Inlet Node Name
  5310. Sec CW Supply Outlet Node, !- Plant Side Outlet Node Name
  5311. Sec CW Supply Branches, !- Plant Side Branch List Name
  5312. Sec CW Supply Connector List, !- Plant Side Connector List Name
  5313. Sec CW Demand Inlet Node,!- Demand Side Inlet Node Name
  5314. Sec CW Demand Outlet Node, !- Demand Side Outlet Node Name
  5315. Sec CW Demand Branches, !- Demand Side Branch List Name
  5316. Sec CW Demand Connector List, !- Demand Side Connector List Name
  5317. Optimal, !- Load Distribution Scheme
  5318. , !- Availability Manager List Name
  5319. SingleSetpoint; !- Plant Loop Demand Calculation Scheme
  5320.  
  5321.  
  5322. !- =========== ALL OBJECTS IN CLASS: CONDENSERLOOP ===========
  5323.  
  5324. CondenserLoop,
  5325. Condenser Water Loop, !- Name
  5326. Water, !- Fluid Type
  5327. , !- User Defined Fluid Type
  5328. Condenser Water Loop Operation Schemes, !- Condenser Equipment Operation Scheme Name
  5329. CndSys Supply Outlet Node, !- Condenser Loop Temperature Setpoint Node Name
  5330. 100, !- Maximum Loop Temperature {C}
  5331. 1, !- Minimum Loop Temperature {C}
  5332. autosize, !- Maximum Loop Flow Rate {m3/s}
  5333. , !- Minimum Loop Flow Rate {m3/s}
  5334. autocalculate, !- Condenser Loop Volume {m3}
  5335. CndSys Supply Inlet Node,!- Condenser Side Inlet Node Name
  5336. CndSys Supply Outlet Node, !- Condenser Side Outlet Node Name
  5337. Condenser Water Loop Supply Branches, !- Condenser Side Branch List Name
  5338. Condenser Water Loop Supply Connector List, !- Condenser Side Connector List Name
  5339. CndSys Demand Inlet Node,!- Demand Side Inlet Node Name
  5340. CndSys Demand Outlet Node, !- Demand Side Outlet Node Name
  5341. Condenser Water Loop Demand Branches, !- Condenser Demand Side Branch List Name
  5342. Condenser Water Loop Demand Connector List, !- Condenser Demand Side Connector List Name
  5343. Optimal, !- Load Distribution Scheme
  5344. None; !- Pressure Simulation Type
  5345.  
  5346.  
  5347. !- =========== ALL OBJECTS IN CLASS: PLANTEQUIPMENTLIST ===========
  5348.  
  5349. PlantEquipmentList,
  5350. Chilled Water Loop Cooling Equipment List, !- Name
  5351. Chiller:Electric:EIR, !- Equipment 1 Object Type
  5352. Chiller Electric EIR 1; !- Equipment 1 Name
  5353.  
  5354. PlantEquipmentList,
  5355. Condenser Water Loop Cooling Equipment List, !- Name
  5356. CoolingTower:SingleSpeed,!- Equipment 1 Object Type
  5357. Cooling Tower Single Speed 1; !- Equipment 1 Name
  5358.  
  5359. PlantEquipmentList,
  5360. Hot Water Loop Heating Equipment List, !- Name
  5361. Boiler:HotWater, !- Equipment 1 Object Type
  5362. Boiler Hot Water 1; !- Equipment 1 Name
  5363.  
  5364. PlantEquipmentList,
  5365. Sec CW Loop Cooling Equipment List, !- Name
  5366. ThermalStorage:ChilledWater:Stratified, !- Equipment 1 Object Type
  5367. Thermal Storage - Chilled Water Stratified; !- Equipment 1 Name
  5368.  
  5369.  
  5370. !- =========== ALL OBJECTS IN CLASS: PLANTEQUIPMENTOPERATION:COOLINGLOAD ===========
  5371.  
  5372. PlantEquipmentOperation:CoolingLoad,
  5373. Chilled Water Loop Cooling Operation Scheme, !- Name
  5374. 0, !- Load Range 1 Lower Limit {W}
  5375. 1000000000, !- Load Range 1 Upper Limit {W}
  5376. Chilled Water Loop Cooling Equipment List; !- Range 1 Equipment List Name
  5377.  
  5378. PlantEquipmentOperation:CoolingLoad,
  5379. Condenser Water Loop Cooling Operation Scheme, !- Name
  5380. 0, !- Load Range 1 Lower Limit {W}
  5381. 1000000000, !- Load Range 1 Upper Limit {W}
  5382. Condenser Water Loop Cooling Equipment List; !- Range 1 Equipment List Name
  5383.  
  5384. PlantEquipmentOperation:CoolingLoad,
  5385. Sec CW Loop Cooling Operation Scheme, !- Name
  5386. 0, !- Load Range 1 Lower Limit {W}
  5387. 1000000000, !- Load Range 1 Upper Limit {W}
  5388. Sec CW Loop Cooling Equipment List; !- Range 1 Equipment List Name
  5389.  
  5390.  
  5391. !- =========== ALL OBJECTS IN CLASS: PLANTEQUIPMENTOPERATION:HEATINGLOAD ===========
  5392.  
  5393. PlantEquipmentOperation:HeatingLoad,
  5394. Hot Water Loop Heating Operation Scheme, !- Name
  5395. 0, !- Load Range 1 Lower Limit {W}
  5396. 1000000000, !- Load Range 1 Upper Limit {W}
  5397. Hot Water Loop Heating Equipment List; !- Range 1 Equipment List Name
  5398.  
  5399.  
  5400. !- =========== ALL OBJECTS IN CLASS: PLANTEQUIPMENTOPERATIONSCHEMES ===========
  5401.  
  5402. PlantEquipmentOperationSchemes,
  5403. Chilled Water Loop Operation Schemes, !- Name
  5404. PlantEquipmentOperation:CoolingLoad, !- Control Scheme 1 Object Type
  5405. Chilled Water Loop Cooling Operation Scheme, !- Control Scheme 1 Name
  5406. Always On Discrete; !- Control Scheme 1 Schedule Name
  5407.  
  5408. PlantEquipmentOperationSchemes,
  5409. Hot Water Loop Operation Schemes, !- Name
  5410. PlantEquipmentOperation:HeatingLoad, !- Control Scheme 1 Object Type
  5411. Hot Water Loop Heating Operation Scheme, !- Control Scheme 1 Name
  5412. Always On Discrete; !- Control Scheme 1 Schedule Name
  5413.  
  5414. PlantEquipmentOperationSchemes,
  5415. Sec CW Loop Operation Schemes, !- Name
  5416. PlantEquipmentOperation:CoolingLoad, !- Control Scheme 1 Object Type
  5417. Sec CW Loop Cooling Operation Scheme, !- Control Scheme 1 Name
  5418. Always On Discrete; !- Control Scheme 1 Schedule Name
  5419.  
  5420.  
  5421. !- =========== ALL OBJECTS IN CLASS: CONDENSEREQUIPMENTOPERATIONSCHEMES ===========
  5422.  
  5423. CondenserEquipmentOperationSchemes,
  5424. Condenser Water Loop Operation Schemes, !- Name
  5425. PlantEquipmentOperation:CoolingLoad, !- Control Scheme 1 Object Type
  5426. Condenser Water Loop Cooling Operation Scheme, !- Control Scheme 1 Name
  5427. Always On Discrete; !- Control Scheme 1 Schedule Name
  5428.  
  5429.  
  5430. !- =========== ALL OBJECTS IN CLASS: AVAILABILITYMANAGER:SCHEDULED ===========
  5431.  
  5432. AvailabilityManager:Scheduled,
  5433. VAV with Reheat Availability Manager, !- Name
  5434. Always On Discrete; !- Schedule Name
  5435.  
  5436. AvailabilityManager:Scheduled,
  5437. Air Loop HVAC Outdoor Air System 1 Availability Manager, !- Name
  5438. Always On Discrete; !- Schedule Name
  5439.  
  5440.  
  5441. !- =========== ALL OBJECTS IN CLASS: AVAILABILITYMANAGER:NIGHTCYCLE ===========
  5442.  
  5443. AvailabilityManager:NightCycle,
  5444. AHU1 Availability Manager, !- Name
  5445. ALWAYS_ON, !- Applicability Schedule Name
  5446. FanAvailSched, !- Fan Schedule Name
  5447. CycleOnAny, !- Control Type
  5448. 1, !- Thermostat Tolerance {deltaC}
  5449. 3600; !- Cycling Run Time {s}
  5450.  
  5451.  
  5452. !- =========== ALL OBJECTS IN CLASS: AVAILABILITYMANAGERASSIGNMENTLIST ===========
  5453.  
  5454. AvailabilityManagerAssignmentList,
  5455. VAV with ReheatAvailability Manager List, !- Name
  5456. AvailabilityManager:Scheduled, !- Availability Manager 1 Object Type
  5457. VAV with Reheat Availability Manager; !- Availability Manager 1 Name
  5458.  
  5459. AvailabilityManagerAssignmentList,
  5460. AHU1 Availability Manager List, !- Name
  5461. AvailabilityManager:NightCycle, !- Availability Manager 1 Object Type
  5462. AHU1 Availability Manager; !- Availability Manager 1 Name
  5463.  
  5464.  
  5465. !- =========== ALL OBJECTS IN CLASS: SETPOINTMANAGER:SCHEDULED ===========
  5466.  
  5467. SetpointManager:Scheduled,
  5468. Setpoint Manager Scheduled 1, !- Name
  5469. Temperature, !- Control Variable
  5470. Deck_Temperature, !- Schedule Name
  5471. Air Outlet Node1; !- Setpoint Node or NodeList Name
  5472.  
  5473. SetpointManager:Scheduled,
  5474. Primary Chiller Setpoint,!- Name
  5475. Temperature, !- Control Variable
  5476. Chilled_Water_Temperature, !- Schedule Name
  5477. Chiller Outlet Node; !- Setpoint Node or NodeList Name
  5478.  
  5479. SetpointManager:Scheduled,
  5480. Setpoint Manager Scheduled 2, !- Name
  5481. Temperature, !- Control Variable
  5482. Hot_Water_Temperature, !- Schedule Name
  5483. HeatSys1 Supply Outlet Node; !- Setpoint Node or NodeList Name
  5484.  
  5485. SetpointManager:Scheduled,
  5486. Setpoint Manager CW Loop,!- Name
  5487. Temperature, !- Control Variable
  5488. CW-Primary-Loop-Temp-Schedule, !- Schedule Name
  5489. CW Supply Outlet Node; !- Setpoint Node or NodeList Name
  5490.  
  5491. SetpointManager:Scheduled,
  5492. Setpoint Manager Sec CW Loop, !- Name
  5493. Temperature, !- Control Variable
  5494. Sec-CW-Primary-Loop-Temp-Schedule, !- Schedule Name
  5495. Sec CW Supply Outlet Node; !- Setpoint Node or NodeList Name
  5496.  
  5497.  
  5498. !- =========== ALL OBJECTS IN CLASS: SETPOINTMANAGER:OUTDOORAIRRESET ===========
  5499.  
  5500. SetpointManager:OutdoorAirReset,
  5501. AHU1 Outlet Setpoint, !- Name
  5502. Temperature, !- Control Variable
  5503. 16.5, !- Setpoint at Outdoor Low Temperature {C}
  5504. 15.5, !- Outdoor Low Temperature {C}
  5505. 13.8, !- Setpoint at Outdoor High Temperature {C}
  5506. 21, !- Outdoor High Temperature {C}
  5507. Air Outlet Node1; !- Setpoint Node or NodeList Name
  5508.  
  5509.  
  5510. !- =========== ALL OBJECTS IN CLASS: SETPOINTMANAGER:MIXEDAIR ===========
  5511.  
  5512. SetpointManager:MixedAir,
  5513. OA Mixed Air Temp Manager 1, !- Name
  5514. Temperature, !- Control Variable
  5515. Air Outlet Node1, !- Reference Setpoint Node Name
  5516. HC Outlet Node 1, !- Fan Inlet Node Name
  5517. Air Outlet Node1, !- Fan Outlet Node Name
  5518. Mixed Air Node1; !- Setpoint Node or NodeList Name
  5519.  
  5520. SetpointManager:MixedAir,
  5521. CC1 SPM, !- Name
  5522. Temperature, !- Control Variable
  5523. Air Outlet Node1, !- Reference Setpoint Node Name
  5524. HC Air Outlet Node1, !- Fan Inlet Node Name
  5525. Air Outlet Node1, !- Fan Outlet Node Name
  5526. CC Air Outlet Node1; !- Setpoint Node or NodeList Name
  5527.  
  5528. SetpointManager:MixedAir,
  5529. HC1SPM, !- Name
  5530. Temperature, !- Control Variable
  5531. Air Outlet Node1, !- Reference Setpoint Node Name
  5532. HC Air Outlet Node1, !- Fan Inlet Node Name
  5533. Air Outlet Node1, !- Fan Outlet Node Name
  5534. HC Air Outlet Node1; !- Setpoint Node or NodeList Name
  5535.  
  5536.  
  5537. !- =========== ALL OBJECTS IN CLASS: SETPOINTMANAGER:FOLLOWOUTDOORAIRTEMPERATURE ===========
  5538.  
  5539. SetpointManager:FollowOutdoorAirTemperature,
  5540. Setpoint Manager Follow Outdoor Air Temperature 1, !- Name
  5541. Temperature, !- Control Variable
  5542. OutdoorAirWetBulb, !- Reference Temperature Type
  5543. 1.5, !- Offset Temperature Difference {deltaC}
  5544. 80, !- Maximum Setpoint Temperature {C}
  5545. 6, !- Minimum Setpoint Temperature {C}
  5546. CndSys Supply Outlet Node; !- Setpoint Node or NodeList Name
  5547.  
  5548.  
  5549. !- =========== ALL OBJECTS IN CLASS: CURVE:QUADRATIC ===========
  5550.  
  5551. Curve:Quadratic,
  5552. Curve Quadratic 1, !- Name
  5553. 0.222903, !- Coefficient1 Constant
  5554. 0.313387, !- Coefficient2 x
  5555. 0.46371, !- Coefficient3 x**2
  5556. 0, !- Minimum Value of x
  5557. 1; !- Maximum Value of x
  5558.  
  5559. Curve:Quadratic,
  5560. Cool-PLF-fPLR, !- Name
  5561. 0.90949556, !- Coefficient1 Constant
  5562. 0.09864773, !- Coefficient2 x
  5563. -0.00819488, !- Coefficient3 x**2
  5564. 0, !- Minimum Value of x
  5565. 1, !- Maximum Value of x
  5566. 0.7, !- Minimum Curve Output
  5567. 1; !- Maximum Curve Output
  5568.  
  5569.  
  5570. !- =========== ALL OBJECTS IN CLASS: CURVE:CUBIC ===========
  5571.  
  5572. Curve:Cubic,
  5573. ConstantCubic, !- Name
  5574. 1, !- Coefficient1 Constant
  5575. 0, !- Coefficient2 x
  5576. 0, !- Coefficient3 x**2
  5577. 0, !- Coefficient4 x**3
  5578. -100, !- Minimum Value of x
  5579. 100; !- Maximum Value of x
  5580.  
  5581.  
  5582. !- =========== ALL OBJECTS IN CLASS: CURVE:BIQUADRATIC ===========
  5583.  
  5584. Curve:Biquadratic,
  5585. Curve Biquadratic 1, !- Name
  5586. 0.258, !- Coefficient1 Constant
  5587. 0.0389, !- Coefficient2 x
  5588. -0.000217, !- Coefficient3 x**2
  5589. 0.0469, !- Coefficient4 y
  5590. -0.000943, !- Coefficient5 y**2
  5591. -0.000343, !- Coefficient6 x*y
  5592. 5, !- Minimum Value of x
  5593. 10, !- Maximum Value of x
  5594. 24, !- Minimum Value of y
  5595. 35; !- Maximum Value of y
  5596.  
  5597. Curve:Biquadratic,
  5598. Curve Biquadratic 2, !- Name
  5599. 0.934, !- Coefficient1 Constant
  5600. -0.0582, !- Coefficient2 x
  5601. 0.0045, !- Coefficient3 x**2
  5602. 0.00243, !- Coefficient4 y
  5603. 0.000486, !- Coefficient5 y**2
  5604. -0.00122, !- Coefficient6 x*y
  5605. 5, !- Minimum Value of x
  5606. 10, !- Maximum Value of x
  5607. 24, !- Minimum Value of y
  5608. 35; !- Maximum Value of y
  5609.  
  5610. Curve:Biquadratic,
  5611. Boiler Efficiency, !- Name
  5612. 1, !- Coefficient1 Constant
  5613. 0, !- Coefficient2 x
  5614. 0, !- Coefficient3 x**2
  5615. 0, !- Coefficient4 y
  5616. 0, !- Coefficient5 y**2
  5617. 0, !- Coefficient6 x*y
  5618. 0, !- Minimum Value of x
  5619. 1, !- Maximum Value of x
  5620. 0, !- Minimum Value of y
  5621. 1, !- Maximum Value of y
  5622. , !- Minimum Curve Output
  5623. , !- Maximum Curve Output
  5624. Dimensionless, !- Input Unit Type for X
  5625. Dimensionless, !- Input Unit Type for Y
  5626. Dimensionless; !- Output Unit Type
  5627.  
  5628. Curve:Biquadratic,
  5629. Cool-Cap-fT, !- Name
  5630. 0.9712123, !- Coefficient1 Constant
  5631. -0.015275502, !- Coefficient2 x
  5632. 0.0014434524, !- Coefficient3 x**2
  5633. -0.00039321, !- Coefficient4 y
  5634. -6.8364e-006, !- Coefficient5 y**2
  5635. -0.0002905956, !- Coefficient6 x*y
  5636. -100, !- Minimum Value of x
  5637. 100, !- Maximum Value of x
  5638. -100, !- Minimum Value of y
  5639. 100; !- Maximum Value of y
  5640.  
  5641. Curve:Biquadratic,
  5642. Cool-EIR-fT, !- Name
  5643. 0.28687133, !- Coefficient1 Constant
  5644. 0.023902164, !- Coefficient2 x
  5645. -0.000810648, !- Coefficient3 x**2
  5646. 0.013458546, !- Coefficient4 y
  5647. 0.0003389364, !- Coefficient5 y**2
  5648. -0.0004870044, !- Coefficient6 x*y
  5649. -100, !- Minimum Value of x
  5650. 100, !- Maximum Value of x
  5651. -100, !- Minimum Value of y
  5652. 100; !- Maximum Value of y
  5653.  
  5654.  
  5655. !- =========== ALL OBJECTS IN CLASS: LIFECYCLECOST:PARAMETERS ===========
  5656.  
  5657. LifeCycleCost:Parameters,
  5658. {9fbbe050-fb5b-402b-9fd4-3ee5a14f6a2f}, !- Name
  5659. EndOfYear, !- Discounting Convention
  5660. ConstantDollar, !- Inflation Approach
  5661. 0.03, !- Real Discount Rate
  5662. , !- Nominal Discount Rate
  5663. , !- Inflation
  5664. , !- Base Date Month
  5665. 2011, !- Base Date Year
  5666. , !- Service Date Month
  5667. 2011, !- Service Date Year
  5668. 25, !- Length of Study Period in Years
  5669. , !- Tax rate
  5670. None; !- Depreciation Method
  5671.  
  5672.  
  5673. !- =========== ALL OBJECTS IN CLASS: LIFECYCLECOST:NONRECURRINGCOST ===========
  5674.  
  5675. LifeCycleCost:NonrecurringCost,
  5676. Default Cost, !- Name
  5677. Construction, !- Category
  5678. 0, !- Cost
  5679. ServicePeriod; !- Start of Costs
  5680.  
  5681.  
  5682. !- =========== ALL OBJECTS IN CLASS: LIFECYCLECOST:USEPRICEESCALATION ===========
  5683.  
  5684. LifeCycleCost:UsePriceEscalation,
  5685. U.S. Avg Commercial-Electricity, !- Name
  5686. Electricity, !- Resource
  5687. 2011, !- Escalation Start Year
  5688. January, !- Escalation Start Month
  5689. 0.9838, !- Year 1 Escalation
  5690. 0.9730, !- Year 2 Escalation
  5691. 0.9632, !- Year 3 Escalation
  5692. 0.9611, !- Year 4 Escalation
  5693. 0.9571, !- Year 5 Escalation
  5694. 0.9553, !- Year 6 Escalation
  5695. 0.9539, !- Year 7 Escalation
  5696. 0.9521, !- Year 8 Escalation
  5697. 0.9546, !- Year 9 Escalation
  5698. 0.9550, !- Year 10 Escalation
  5699. 0.9553, !- Year 11 Escalation
  5700. 0.9564, !- Year 12 Escalation
  5701. 0.9575, !- Year 13 Escalation
  5702. 0.9596, !- Year 14 Escalation
  5703. 0.9618, !- Year 15 Escalation
  5704. 0.9614, !- Year 16 Escalation
  5705. 0.9618, !- Year 17 Escalation
  5706. 0.9618, !- Year 18 Escalation
  5707. 0.9593, !- Year 19 Escalation
  5708. 0.9589, !- Year 20 Escalation
  5709. 0.9607, !- Year 21 Escalation
  5710. 0.9625, !- Year 22 Escalation
  5711. 0.9650, !- Year 23 Escalation
  5712. 0.9708, !- Year 24 Escalation
  5713. 0.9751, !- Year 25 Escalation
  5714. 0.9762, !- Year 26 Escalation
  5715. 0.9766, !- Year 27 Escalation
  5716. 0.9766, !- Year 28 Escalation
  5717. 0.9769, !- Year 29 Escalation
  5718. 0.9773; !- Year 30 Escalation
  5719.  
  5720. LifeCycleCost:UsePriceEscalation,
  5721. U.S. Avg Commercial-Distillate Oil, !- Name
  5722. FuelOil#1, !- Resource
  5723. 2011, !- Escalation Start Year
  5724. January, !- Escalation Start Month
  5725. 0.9714, !- Year 1 Escalation
  5726. 0.9730, !- Year 2 Escalation
  5727. 0.9942, !- Year 3 Escalation
  5728. 1.0164, !- Year 4 Escalation
  5729. 1.0541, !- Year 5 Escalation
  5730. 1.0928, !- Year 6 Escalation
  5731. 1.1267, !- Year 7 Escalation
  5732. 1.1580, !- Year 8 Escalation
  5733. 1.1792, !- Year 9 Escalation
  5734. 1.1967, !- Year 10 Escalation
  5735. 1.2200, !- Year 11 Escalation
  5736. 1.2333, !- Year 12 Escalation
  5737. 1.2566, !- Year 13 Escalation
  5738. 1.2709, !- Year 14 Escalation
  5739. 1.2826, !- Year 15 Escalation
  5740. 1.2985, !- Year 16 Escalation
  5741. 1.3102, !- Year 17 Escalation
  5742. 1.3250, !- Year 18 Escalation
  5743. 1.3261, !- Year 19 Escalation
  5744. 1.3282, !- Year 20 Escalation
  5745. 1.3324, !- Year 21 Escalation
  5746. 1.3356, !- Year 22 Escalation
  5747. 1.3431, !- Year 23 Escalation
  5748. 1.3510, !- Year 24 Escalation
  5749. 1.3568, !- Year 25 Escalation
  5750. 1.3606, !- Year 26 Escalation
  5751. 1.3637, !- Year 27 Escalation
  5752. 1.3674, !- Year 28 Escalation
  5753. 1.3706, !- Year 29 Escalation
  5754. 1.3743; !- Year 30 Escalation
  5755.  
  5756. LifeCycleCost:UsePriceEscalation,
  5757. U.S. Avg Commercial-Residual Oil, !- Name
  5758. FuelOil#2, !- Resource
  5759. 2011, !- Escalation Start Year
  5760. January, !- Escalation Start Month
  5761. 0.8469, !- Year 1 Escalation
  5762. 0.8257, !- Year 2 Escalation
  5763. 0.8681, !- Year 3 Escalation
  5764. 0.8988, !- Year 4 Escalation
  5765. 0.9289, !- Year 5 Escalation
  5766. 0.9604, !- Year 6 Escalation
  5767. 0.9897, !- Year 7 Escalation
  5768. 1.0075, !- Year 8 Escalation
  5769. 1.0314, !- Year 9 Escalation
  5770. 1.0554, !- Year 10 Escalation
  5771. 1.0861, !- Year 11 Escalation
  5772. 1.1278, !- Year 12 Escalation
  5773. 1.1497, !- Year 13 Escalation
  5774. 1.1620, !- Year 14 Escalation
  5775. 1.1743, !- Year 15 Escalation
  5776. 1.1852, !- Year 16 Escalation
  5777. 1.1948, !- Year 17 Escalation
  5778. 1.2037, !- Year 18 Escalation
  5779. 1.2071, !- Year 19 Escalation
  5780. 1.2119, !- Year 20 Escalation
  5781. 1.2139, !- Year 21 Escalation
  5782. 1.2194, !- Year 22 Escalation
  5783. 1.2276, !- Year 23 Escalation
  5784. 1.2365, !- Year 24 Escalation
  5785. 1.2420, !- Year 25 Escalation
  5786. 1.2461, !- Year 26 Escalation
  5787. 1.2509, !- Year 27 Escalation
  5788. 1.2550, !- Year 28 Escalation
  5789. 1.2591, !- Year 29 Escalation
  5790. 1.2638; !- Year 30 Escalation
  5791.  
  5792. LifeCycleCost:UsePriceEscalation,
  5793. U.S. Avg Commercial-Natural gas, !- Name
  5794. NaturalGas, !- Resource
  5795. 2011, !- Escalation Start Year
  5796. January, !- Escalation Start Month
  5797. 0.9823, !- Year 1 Escalation
  5798. 0.9557, !- Year 2 Escalation
  5799. 0.9279, !- Year 3 Escalation
  5800. 0.9257, !- Year 4 Escalation
  5801. 0.9346, !- Year 5 Escalation
  5802. 0.9412, !- Year 6 Escalation
  5803. 0.9512, !- Year 7 Escalation
  5804. 0.9645, !- Year 8 Escalation
  5805. 0.9856, !- Year 9 Escalation
  5806. 1.0067, !- Year 10 Escalation
  5807. 1.0222, !- Year 11 Escalation
  5808. 1.0410, !- Year 12 Escalation
  5809. 1.0610, !- Year 13 Escalation
  5810. 1.0787, !- Year 14 Escalation
  5811. 1.0942, !- Year 15 Escalation
  5812. 1.1098, !- Year 16 Escalation
  5813. 1.1220, !- Year 17 Escalation
  5814. 1.1308, !- Year 18 Escalation
  5815. 1.1386, !- Year 19 Escalation
  5816. 1.1486, !- Year 20 Escalation
  5817. 1.1619, !- Year 21 Escalation
  5818. 1.1763, !- Year 22 Escalation
  5819. 1.1918, !- Year 23 Escalation
  5820. 1.2118, !- Year 24 Escalation
  5821. 1.2284, !- Year 25 Escalation
  5822. 1.2439, !- Year 26 Escalation
  5823. 1.2605, !- Year 27 Escalation
  5824. 1.2772, !- Year 28 Escalation
  5825. 1.2938, !- Year 29 Escalation
  5826. 1.3115; !- Year 30 Escalation
  5827.  
  5828. LifeCycleCost:UsePriceEscalation,
  5829. U.S. Avg Commercial-Coal, !- Name
  5830. Coal, !- Resource
  5831. 2011, !- Escalation Start Year
  5832. January, !- Escalation Start Month
  5833. 0.9970, !- Year 1 Escalation
  5834. 1.0089, !- Year 2 Escalation
  5835. 1.0089, !- Year 3 Escalation
  5836. 0.9941, !- Year 4 Escalation
  5837. 0.9941, !- Year 5 Escalation
  5838. 1.0000, !- Year 6 Escalation
  5839. 1.0030, !- Year 7 Escalation
  5840. 1.0059, !- Year 8 Escalation
  5841. 1.0089, !- Year 9 Escalation
  5842. 1.0119, !- Year 10 Escalation
  5843. 1.0148, !- Year 11 Escalation
  5844. 1.0178, !- Year 12 Escalation
  5845. 1.0208, !- Year 13 Escalation
  5846. 1.0267, !- Year 14 Escalation
  5847. 1.0297, !- Year 15 Escalation
  5848. 1.0356, !- Year 16 Escalation
  5849. 1.0415, !- Year 17 Escalation
  5850. 1.0534, !- Year 18 Escalation
  5851. 1.0564, !- Year 19 Escalation
  5852. 1.0593, !- Year 20 Escalation
  5853. 1.0653, !- Year 21 Escalation
  5854. 1.0712, !- Year 22 Escalation
  5855. 1.0742, !- Year 23 Escalation
  5856. 1.0801, !- Year 24 Escalation
  5857. 1.0831, !- Year 25 Escalation
  5858. 1.0831, !- Year 26 Escalation
  5859. 1.0861, !- Year 27 Escalation
  5860. 1.0890, !- Year 28 Escalation
  5861. 1.0920, !- Year 29 Escalation
  5862. 1.0950; !- Year 30 Escalation
  5863.  
  5864.  
  5865. !- =========== ALL OBJECTS IN CLASS: OUTPUT:VARIABLEDICTIONARY ===========
  5866.  
  5867. Output:VariableDictionary,
  5868. IDF, !- Key Field
  5869. Unsorted; !- Sort Option
  5870.  
  5871.  
  5872. !- =========== ALL OBJECTS IN CLASS: OUTPUT:TABLE:SUMMARYREPORTS ===========
  5873.  
  5874. Output:Table:SummaryReports,
  5875. AllSummary; !- Report 1 Name
  5876.  
  5877.  
  5878. !- =========== ALL OBJECTS IN CLASS: OUTPUTCONTROL:TABLE:STYLE ===========
  5879.  
  5880. OutputControl:Table:Style,
  5881. HTML; !- Column Separator
  5882.  
  5883.  
  5884. !- =========== ALL OBJECTS IN CLASS: OUTPUTCONTROL:REPORTINGTOLERANCES ===========
  5885.  
  5886. OutputControl:ReportingTolerances,
  5887. 0.2, !- Tolerance for Time Heating Setpoint Not Met {deltaC}
  5888. 0.2; !- Tolerance for Time Cooling Setpoint Not Met {deltaC}
  5889.  
  5890.  
  5891. !- =========== ALL OBJECTS IN CLASS: OUTPUT:VARIABLE ===========
  5892.  
  5893. Output:Variable,
  5894. *, !- Key Value
  5895. People Air Temperature, !- Variable Name
  5896. Hourly; !- Reporting Frequency
  5897.  
  5898. Output:Variable,
  5899. *, !- Key Value
  5900. Zone Air Heat Balance Air Energy Storage Rate, !- Variable Name
  5901. Hourly; !- Reporting Frequency
  5902.  
  5903. Output:Variable,
  5904. *, !- Key Value
  5905. Zone Windows Total Heat Loss Rate, !- Variable Name
  5906. Hourly; !- Reporting Frequency
  5907.  
  5908. Output:Variable,
  5909. *, !- Key Value
  5910. Zone Windows Total Transmitted Solar Radiation Energy, !- Variable Name
  5911. Hourly; !- Reporting Frequency
  5912.  
  5913. Output:Variable,
  5914. *, !- Key Value
  5915. Zone Windows Total Transmitted Solar Radiation Rate, !- Variable Name
  5916. Hourly; !- Reporting Frequency
  5917.  
  5918. Output:Variable,
  5919. *, !- Key Value
  5920. Zone Air Heat Balance Internal Convective Heat Gain Rate, !- Variable Name
  5921. Hourly; !- Reporting Frequency
  5922.  
  5923. Output:Variable,
  5924. *, !- Key Value
  5925. Zone Air Heat Balance Interzone Air Transfer Rate, !- Variable Name
  5926. Hourly; !- Reporting Frequency
  5927.  
  5928. Output:Variable,
  5929. *, !- Key Value
  5930. Zone Air Heat Balance Outdoor Air Transfer Rate, !- Variable Name
  5931. Hourly; !- Reporting Frequency
  5932.  
  5933. Output:Variable,
  5934. *, !- Key Value
  5935. Zone Air Heat Balance Surface Convection Rate, !- Variable Name
  5936. Hourly; !- Reporting Frequency
  5937.  
  5938. Output:Variable,
  5939. *, !- Key Value
  5940. Zone Air Heat Balance System Air Transfer Rate, !- Variable Name
  5941. Hourly; !- Reporting Frequency
  5942.  
  5943. Output:Variable,
  5944. *, !- Key Value
  5945. Zone Air Humidity Ratio, !- Variable Name
  5946. Hourly; !- Reporting Frequency
  5947.  
  5948. Output:Variable,
  5949. *, !- Key Value
  5950. Zone Air Relative Humidity, !- Variable Name
  5951. Hourly; !- Reporting Frequency
  5952.  
  5953. Output:Variable,
  5954. *, !- Key Value
  5955. Zone Air System Sensible Cooling Energy, !- Variable Name
  5956. Hourly; !- Reporting Frequency
  5957.  
  5958. Output:Variable,
  5959. *, !- Key Value
  5960. Zone Air System Sensible Cooling Rate, !- Variable Name
  5961. Hourly; !- Reporting Frequency
  5962.  
  5963. Output:Variable,
  5964. *, !- Key Value
  5965. People Convective Heating Energy, !- Variable Name
  5966. Hourly; !- Reporting Frequency
  5967.  
  5968. Output:Variable,
  5969. *, !- Key Value
  5970. Zone Air System Sensible Heating Energy, !- Variable Name
  5971. Hourly; !- Reporting Frequency
  5972.  
  5973. Output:Variable,
  5974. *, !- Key Value
  5975. Zone Air System Sensible Heating Rate, !- Variable Name
  5976. Hourly; !- Reporting Frequency
  5977.  
  5978. Output:Variable,
  5979. *, !- Key Value
  5980. Zone Air Temperature, !- Variable Name
  5981. Hourly; !- Reporting Frequency
  5982.  
  5983. Output:Variable,
  5984. *, !- Key Value
  5985. Zone Electric Equipment Convective Heating Energy, !- Variable Name
  5986. Hourly; !- Reporting Frequency
  5987.  
  5988. Output:Variable,
  5989. *, !- Key Value
  5990. Zone Electric Equipment Electric Energy, !- Variable Name
  5991. Hourly; !- Reporting Frequency
  5992.  
  5993. Output:Variable,
  5994. *, !- Key Value
  5995. Zone Electric Equipment Electric Power, !- Variable Name
  5996. Hourly; !- Reporting Frequency
  5997.  
  5998. Output:Variable,
  5999. *, !- Key Value
  6000. Zone Electric Equipment Latent Gain Energy, !- Variable Name
  6001. Hourly; !- Reporting Frequency
  6002.  
  6003. Output:Variable,
  6004. *, !- Key Value
  6005. Zone Electric Equipment Lost Heat Energy, !- Variable Name
  6006. Hourly; !- Reporting Frequency
  6007.  
  6008. Output:Variable,
  6009. *, !- Key Value
  6010. Zone Electric Equipment Radiant Heating Energy, !- Variable Name
  6011. Hourly; !- Reporting Frequency
  6012.  
  6013. Output:Variable,
  6014. *, !- Key Value
  6015. Zone Electric Equipment Total Heating Energy, !- Variable Name
  6016. Hourly; !- Reporting Frequency
  6017.  
  6018. Output:Variable,
  6019. *, !- Key Value
  6020. People Latent Gain Energy, !- Variable Name
  6021. Hourly; !- Reporting Frequency
  6022.  
  6023. Output:Variable,
  6024. *, !- Key Value
  6025. Zone Exterior Windows Total Transmitted Beam Solar Radiation Energy, !- Variable Name
  6026. Hourly; !- Reporting Frequency
  6027.  
  6028. Output:Variable,
  6029. *, !- Key Value
  6030. Zone Exterior Windows Total Transmitted Beam Solar Radiation Rate, !- Variable Name
  6031. Hourly; !- Reporting Frequency
  6032.  
  6033. Output:Variable,
  6034. *, !- Key Value
  6035. Zone Exterior Windows Total Transmitted Diffuse Solar Radiation Rate, !- Variable Name
  6036. Hourly; !- Reporting Frequency
  6037.  
  6038. Output:Variable,
  6039. *, !- Key Value
  6040. Zone Infiltration Air Change Rate, !- Variable Name
  6041. Hourly; !- Reporting Frequency
  6042.  
  6043. Output:Variable,
  6044. *, !- Key Value
  6045. Zone Infiltration Current Density Volume Flow Rate, !- Variable Name
  6046. Hourly; !- Reporting Frequency
  6047.  
  6048. Output:Variable,
  6049. *, !- Key Value
  6050. Zone Infiltration Current Density Volume, !- Variable Name
  6051. Hourly; !- Reporting Frequency
  6052.  
  6053. Output:Variable,
  6054. *, !- Key Value
  6055. Zone Infiltration Latent Heat Gain Energy, !- Variable Name
  6056. Hourly; !- Reporting Frequency
  6057.  
  6058. Output:Variable,
  6059. *, !- Key Value
  6060. Zone Infiltration Mass, !- Variable Name
  6061. Hourly; !- Reporting Frequency
  6062.  
  6063. Output:Variable,
  6064. *, !- Key Value
  6065. Zone Infiltration Sensible Heat Gain Energy, !- Variable Name
  6066. Hourly; !- Reporting Frequency
  6067.  
  6068. Output:Variable,
  6069. *, !- Key Value
  6070. Zone Infiltration Sensible Heat Loss Energy, !- Variable Name
  6071. Hourly; !- Reporting Frequency
  6072.  
  6073. Output:Variable,
  6074. *, !- Key Value
  6075. People Occupant Count, !- Variable Name
  6076. Hourly; !- Reporting Frequency
  6077.  
  6078. Output:Variable,
  6079. *, !- Key Value
  6080. Zone Infiltration Standard Density Volume Flow Rate, !- Variable Name
  6081. Hourly; !- Reporting Frequency
  6082.  
  6083. Output:Variable,
  6084. *, !- Key Value
  6085. Zone Infiltration Standard Density Volume, !- Variable Name
  6086. Hourly; !- Reporting Frequency
  6087.  
  6088. Output:Variable,
  6089. *, !- Key Value
  6090. Zone Infiltration Total Heat Gain Energy, !- Variable Name
  6091. Hourly; !- Reporting Frequency
  6092.  
  6093. Output:Variable,
  6094. *, !- Key Value
  6095. Zone Infiltration Total Heat Loss Energy, !- Variable Name
  6096. Hourly; !- Reporting Frequency
  6097.  
  6098. Output:Variable,
  6099. *, !- Key Value
  6100. Zone Interior Windows Total Transmitted Beam Solar Radiation Energy, !- Variable Name
  6101. Hourly; !- Reporting Frequency
  6102.  
  6103. Output:Variable,
  6104. *, !- Key Value
  6105. Zone Interior Windows Total Transmitted Beam Solar Radiation Rate, !- Variable Name
  6106. Hourly; !- Reporting Frequency
  6107.  
  6108. Output:Variable,
  6109. *, !- Key Value
  6110. Zone Interior Windows Total Transmitted Diffuse Solar Radiation Rate, !- Variable Name
  6111. Hourly; !- Reporting Frequency
  6112.  
  6113. Output:Variable,
  6114. *, !- Key Value
  6115. Zone Lights Convective Heating Energy, !- Variable Name
  6116. Hourly; !- Reporting Frequency
  6117.  
  6118. Output:Variable,
  6119. *, !- Key Value
  6120. Zone Lights Electric Energy, !- Variable Name
  6121. Hourly; !- Reporting Frequency
  6122.  
  6123. Output:Variable,
  6124. *, !- Key Value
  6125. Zone Lights Electric Power, !- Variable Name
  6126. Hourly; !- Reporting Frequency
  6127.  
  6128. Output:Variable,
  6129. *, !- Key Value
  6130. People Radiant Heating Energy, !- Variable Name
  6131. Hourly; !- Reporting Frequency
  6132.  
  6133. Output:Variable,
  6134. *, !- Key Value
  6135. Zone Lights Radiant Heating Energy, !- Variable Name
  6136. Hourly; !- Reporting Frequency
  6137.  
  6138. Output:Variable,
  6139. *, !- Key Value
  6140. Zone Lights Return Air Heating Energy, !- Variable Name
  6141. Hourly; !- Reporting Frequency
  6142.  
  6143. Output:Variable,
  6144. *, !- Key Value
  6145. Zone Lights Total Heating Energy, !- Variable Name
  6146. Hourly; !- Reporting Frequency
  6147.  
  6148. Output:Variable,
  6149. *, !- Key Value
  6150. Zone Lights Visible Radiation Heating Energy, !- Variable Name
  6151. Hourly; !- Reporting Frequency
  6152.  
  6153. Output:Variable,
  6154. *, !- Key Value
  6155. Zone Mean Air Humidity Ratio, !- Variable Name
  6156. Hourly; !- Reporting Frequency
  6157.  
  6158. Output:Variable,
  6159. *, !- Key Value
  6160. Zone Mean Air Temperature, !- Variable Name
  6161. Hourly; !- Reporting Frequency
  6162.  
  6163. Output:Variable,
  6164. *, !- Key Value
  6165. Zone Mean Radiant Temperature, !- Variable Name
  6166. Hourly; !- Reporting Frequency
  6167.  
  6168. Output:Variable,
  6169. *, !- Key Value
  6170. Zone Mechanical Ventilation Air Changes per Hour, !- Variable Name
  6171. Hourly; !- Reporting Frequency
  6172.  
  6173. Output:Variable,
  6174. *, !- Key Value
  6175. Zone Mechanical Ventilation Cooling Load Decrease Energy, !- Variable Name
  6176. Hourly; !- Reporting Frequency
  6177.  
  6178. Output:Variable,
  6179. *, !- Key Value
  6180. Zone Mechanical Ventilation Cooling Load Increase Energy Due to Overheating Energy, !- Variable Name
  6181. Hourly; !- Reporting Frequency
  6182.  
  6183. Output:Variable,
  6184. *, !- Key Value
  6185. People Sensible Heating Energy, !- Variable Name
  6186. Hourly; !- Reporting Frequency
  6187.  
  6188. Output:Variable,
  6189. *, !- Key Value
  6190. Zone Mechanical Ventilation Cooling Load Increase Energy, !- Variable Name
  6191. Hourly; !- Reporting Frequency
  6192.  
  6193. Output:Variable,
  6194. *, !- Key Value
  6195. Zone Mechanical Ventilation Current Density Volume Flow Rate, !- Variable Name
  6196. Hourly; !- Reporting Frequency
  6197.  
  6198. Output:Variable,
  6199. *, !- Key Value
  6200. Zone Mechanical Ventilation Current Density Volume, !- Variable Name
  6201. Hourly; !- Reporting Frequency
  6202.  
  6203. Output:Variable,
  6204. *, !- Key Value
  6205. Zone Mechanical Ventilation Heating Load Decrease Energy, !- Variable Name
  6206. Hourly; !- Reporting Frequency
  6207.  
  6208. Output:Variable,
  6209. *, !- Key Value
  6210. Zone Mechanical Ventilation Heating Load Increase Energy Due to Overcooling Energy, !- Variable Name
  6211. Hourly; !- Reporting Frequency
  6212.  
  6213. Output:Variable,
  6214. *, !- Key Value
  6215. Zone Mechanical Ventilation Heating Load Increase Energy, !- Variable Name
  6216. Hourly; !- Reporting Frequency
  6217.  
  6218. Output:Variable,
  6219. *, !- Key Value
  6220. Zone Mechanical Ventilation Mass Flow Rate, !- Variable Name
  6221. Hourly; !- Reporting Frequency
  6222.  
  6223. Output:Variable,
  6224. *, !- Key Value
  6225. Zone Mechanical Ventilation Mass, !- Variable Name
  6226. Hourly; !- Reporting Frequency
  6227.  
  6228. Output:Variable,
  6229. *, !- Key Value
  6230. Zone Mechanical Ventilation No Load Heat Addition Energy, !- Variable Name
  6231. Hourly; !- Reporting Frequency
  6232.  
  6233. Output:Variable,
  6234. *, !- Key Value
  6235. Zone Mechanical Ventilation No Load Heat Removal Energy, !- Variable Name
  6236. Hourly; !- Reporting Frequency
  6237.  
  6238. Output:Variable,
  6239. *, !- Key Value
  6240. People Total Heating Energy, !- Variable Name
  6241. Hourly; !- Reporting Frequency
  6242.  
  6243. Output:Variable,
  6244. *, !- Key Value
  6245. Zone Mechanical Ventilation Standard Density Volume Flow Rate, !- Variable Name
  6246. Hourly; !- Reporting Frequency
  6247.  
  6248. Output:Variable,
  6249. *, !- Key Value
  6250. Zone Mechanical Ventilation Standard Density Volume, !- Variable Name
  6251. Hourly; !- Reporting Frequency
  6252.  
  6253. Output:Variable,
  6254. *, !- Key Value
  6255. Zone Operative Temperature, !- Variable Name
  6256. Hourly; !- Reporting Frequency
  6257.  
  6258. Output:Variable,
  6259. *, !- Key Value
  6260. Zone Outdoor Air Drybulb Temperature, !- Variable Name
  6261. Hourly; !- Reporting Frequency
  6262.  
  6263. Output:Variable,
  6264. *, !- Key Value
  6265. Zone Outdoor Air Wetbulb Temperature, !- Variable Name
  6266. Hourly; !- Reporting Frequency
  6267.  
  6268. Output:Variable,
  6269. *, !- Key Value
  6270. Zone Outdoor Air Wind Speed, !- Variable Name
  6271. Hourly; !- Reporting Frequency
  6272.  
  6273. Output:Variable,
  6274. *, !- Key Value
  6275. Zone People Convective Heating Energy, !- Variable Name
  6276. Hourly; !- Reporting Frequency
  6277.  
  6278. Output:Variable,
  6279. *, !- Key Value
  6280. Zone People Latent Gain Energy, !- Variable Name
  6281. Hourly; !- Reporting Frequency
  6282.  
  6283. Output:Variable,
  6284. *, !- Key Value
  6285. Zone People Occupant Count, !- Variable Name
  6286. Hourly; !- Reporting Frequency
  6287.  
  6288. Output:Variable,
  6289. *, !- Key Value
  6290. Zone People Radiant Heating Energy, !- Variable Name
  6291. Hourly; !- Reporting Frequency
  6292.  
  6293. Output:Variable,
  6294. *, !- Key Value
  6295. Surface Inside Face Temperature, !- Variable Name
  6296. Hourly; !- Reporting Frequency
  6297.  
  6298. Output:Variable,
  6299. *, !- Key Value
  6300. Zone People Sensible Heating Energy, !- Variable Name
  6301. Hourly; !- Reporting Frequency
  6302.  
  6303. Output:Variable,
  6304. *, !- Key Value
  6305. Zone People Total Heating Energy, !- Variable Name
  6306. Hourly; !- Reporting Frequency
  6307.  
  6308. Output:Variable,
  6309. *, !- Key Value
  6310. Zone Predicted Moisture Load Moisture Transfer Rate, !- Variable Name
  6311. Hourly; !- Reporting Frequency
  6312.  
  6313. Output:Variable,
  6314. *, !- Key Value
  6315. Zone Predicted Moisture Load to Dehumidifying Setpoint Moisture Transfer Rate, !- Variable Name
  6316. Hourly; !- Reporting Frequency
  6317.  
  6318. Output:Variable,
  6319. *, !- Key Value
  6320. Zone Predicted Moisture Load to Humidifying Setpoint Moisture Transfer Rate, !- Variable Name
  6321. Hourly; !- Reporting Frequency
  6322.  
  6323. Output:Variable,
  6324. *, !- Key Value
  6325. Zone Predicted Sensible Load to Cooling Setpoint Heat Transfer Rate, !- Variable Name
  6326. Hourly; !- Reporting Frequency
  6327.  
  6328. Output:Variable,
  6329. *, !- Key Value
  6330. Zone Predicted Sensible Load to Heating Setpoint Heat Transfer Rate, !- Variable Name
  6331. Hourly; !- Reporting Frequency
  6332.  
  6333. Output:Variable,
  6334. *, !- Key Value
  6335. Zone Predicted Sensible Load to Setpoint Heat Transfer Rate, !- Variable Name
  6336. Hourly; !- Reporting Frequency
  6337.  
  6338. Output:Variable,
  6339. *, !- Key Value
  6340. Zone Thermostat Air Temperature, !- Variable Name
  6341. Hourly; !- Reporting Frequency
  6342.  
  6343. Output:Variable,
  6344. *, !- Key Value
  6345. Zone Thermostat Control Type, !- Variable Name
  6346. Hourly; !- Reporting Frequency
  6347.  
  6348. Output:Variable,
  6349. *, !- Key Value
  6350. Surface Outside Face Temperature, !- Variable Name
  6351. Hourly; !- Reporting Frequency
  6352.  
  6353. Output:Variable,
  6354. *, !- Key Value
  6355. Zone Thermostat Cooling Setpoint Temperature, !- Variable Name
  6356. Hourly; !- Reporting Frequency
  6357.  
  6358. Output:Variable,
  6359. *, !- Key Value
  6360. Zone Thermostat Heating Setpoint Temperature, !- Variable Name
  6361. Hourly; !- Reporting Frequency
  6362.  
  6363. Output:Variable,
  6364. *, !- Key Value
  6365. Zone Total Internal Convective Heating Energy, !- Variable Name
  6366. Hourly; !- Reporting Frequency
  6367.  
  6368. Output:Variable,
  6369. *, !- Key Value
  6370. Zone Total Internal Latent Gain Energy, !- Variable Name
  6371. Hourly; !- Reporting Frequency
  6372.  
  6373. Output:Variable,
  6374. *, !- Key Value
  6375. Zone Total Internal Radiant Heating Energy, !- Variable Name
  6376. Hourly; !- Reporting Frequency
  6377.  
  6378. Output:Variable,
  6379. *, !- Key Value
  6380. Zone Total Internal Total Heating Energy, !- Variable Name
  6381. Hourly; !- Reporting Frequency
  6382.  
  6383. Output:Variable,
  6384. *, !- Key Value
  6385. Zone Total Internal Visible Radiation Heating Energy, !- Variable Name
  6386. Hourly; !- Reporting Frequency
  6387.  
  6388. Output:Variable,
  6389. *, !- Key Value
  6390. Zone Windows Total Heat Gain Energy, !- Variable Name
  6391. Hourly; !- Reporting Frequency
  6392.  
  6393. Output:Variable,
  6394. *, !- Key Value
  6395. Zone Windows Total Heat Gain Rate, !- Variable Name
  6396. Hourly; !- Reporting Frequency
  6397.  
  6398. Output:Variable,
  6399. *, !- Key Value
  6400. Zone Windows Total Heat Loss Energy, !- Variable Name
  6401. Hourly; !- Reporting Frequency
  6402.  
  6403.  
  6404. !- =========== ALL OBJECTS IN CLASS: OUTPUT:METER ===========
  6405.  
  6406. Output:Meter,
  6407. Refrigeration:Electricity, !- Name
  6408. hourly; !- Reporting Frequency
  6409.  
  6410. Output:Meter,
  6411. ExteriorLights:Electricity, !- Name
  6412. hourly; !- Reporting Frequency
  6413.  
  6414. Output:Meter,
  6415. Cooling:Electricity, !- Name
  6416. hourly; !- Reporting Frequency
  6417.  
  6418. Output:Meter,
  6419. Heating:Gas, !- Name
  6420. hourly; !- Reporting Frequency
  6421.  
  6422. Output:Meter,
  6423. ExteriorEquipment:Electricity, !- Name
  6424. hourly; !- Reporting Frequency
  6425.  
  6426. Output:Meter,
  6427. WaterSystems:Gas, !- Name
  6428. hourly; !- Reporting Frequency
  6429.  
  6430. Output:Meter,
  6431. Fans:Electricity, !- Name
  6432. hourly; !- Reporting Frequency
  6433.  
  6434. Output:Meter,
  6435. InteriorEquipment:Gas, !- Name
  6436. hourly; !- Reporting Frequency
  6437.  
  6438. Output:Meter,
  6439. WaterSystems:Electricity,!- Name
  6440. hourly; !- Reporting Frequency
  6441.  
  6442. Output:Meter,
  6443. Humidifier:Electricity, !- Name
  6444. hourly; !- Reporting Frequency
  6445.  
  6446. Output:Meter,
  6447. Pumps:Electricity, !- Name
  6448. hourly; !- Reporting Frequency
  6449.  
  6450. Output:Meter,
  6451. InteriorEquipment:Electricity, !- Name
  6452. hourly; !- Reporting Frequency
  6453.  
  6454. Output:Meter,
  6455. InteriorLights:Electricity, !- Name
  6456. hourly; !- Reporting Frequency
  6457.  
  6458. Output:Meter,
  6459. HeatRejection:Electricity, !- Name
  6460. hourly; !- Reporting Frequency
  6461.  
  6462. Output:Meter,
  6463. Gas:Facility, !- Name
  6464. hourly; !- Reporting Frequency
  6465.  
  6466. Output:Meter,
  6467. Heating:Electricity, !- Name
  6468. hourly; !- Reporting Frequency
  6469.  
  6470. Output:Meter,
  6471. Electricity:Facility, !- Name
  6472. hourly; !- Reporting Frequency
  6473.  
  6474.  
  6475. !- =========== ALL OBJECTS IN CLASS: OUTPUT:SQLITE ===========