Advertisement
Guest User

Untitled

a guest
Jan 1st, 2013
41
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
Bash 4.70 KB | None | 0 0
  1. [root@opentank] ~# smartctl -a /dev/ada2
  2. smartctl 5.42 2011-10-20 r3458 [FreeBSD 8.2-RELEASE-p9 amd64] (local build)
  3. Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
  4.  
  5. === START OF INFORMATION SECTION ===
  6. Model Family:     Western Digital Caviar Green (Adv. Format)
  7. Device Model:     WDC WD20EARS-00MVWB0
  8. Serial Number:    WD-WCAZA7393257
  9. LU WWN Device Id: 5 0014ee 25b3224e3
  10. Firmware Version: 51.0AB51
  11. User Capacity:    2,000,398,934,016 bytes [2.00 TB]
  12. Sector Size:      512 bytes logical/physical
  13. Device is:        In smartctl database [for details use: -P show]
  14. ATA Version is:   8
  15. ATA Standard is:  Exact ATA specification draft version not indicated
  16. Local Time is:    Wed Jan  2 00:22:52 2013 CET
  17. SMART support is: Available - device has SMART capability.
  18. SMART support is: Enabled
  19.  
  20. === START OF READ SMART DATA SECTION ===
  21. SMART overall-health self-assessment test result: FAILED!
  22. Drive failure expected in less than 24 hours. SAVE ALL DATA.
  23. See vendor-specific Attribute list for failed Attributes.
  24.  
  25. General SMART Values:
  26. Offline data collection status:  (0x84) Offline data collection activity
  27.                     was suspended by an interrupting command from host.
  28.                     Auto Offline Data Collection: Enabled.
  29. Self-test execution status:      (   0) The previous self-test routine completed
  30.                     without error or no self-test has ever
  31.                     been run.
  32. Total time to complete Offline
  33. data collection:        (36780) seconds.
  34. Offline data collection
  35. capabilities:            (0x7b) SMART execute Offline immediate.
  36.                     Auto Offline data collection on/off support.
  37.                     Suspend Offline collection upon new
  38.                     command.
  39.                     Offline surface scan supported.
  40.                     Self-test supported.
  41.                     Conveyance Self-test supported.
  42.                     Selective Self-test supported.
  43. SMART capabilities:            (0x0003) Saves SMART data before entering
  44.                     power-saving mode.
  45.                     Supports SMART auto save timer.
  46. Error logging capability:        (0x01) Error logging supported.
  47.                     General Purpose Logging supported.
  48. Short self-test routine
  49. recommended polling time:    (   2) minutes.
  50. Extended self-test routine
  51. recommended polling time:    ( 255) minutes.
  52. Conveyance self-test routine
  53. recommended polling time:    (   5) minutes.
  54. SCT capabilities:          (0x3035) SCT Status supported.
  55.                     SCT Feature Control supported.
  56.                     SCT Data Table supported.
  57.  
  58. SMART Attributes Data Structure revision number: 16
  59. Vendor Specific SMART Attributes with Thresholds:
  60. ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  61.   1 Raw_Read_Error_Rate     0x002f   001   001   051    Pre-fail  Always   FAILING_NOW 31718
  62.   3 Spin_Up_Time            0x0027   253   253   021    Pre-fail  Always       -       933
  63.   4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       -       20
  64.   5 Reallocated_Sector_Ct   0x0033   200   200   140    Pre-fail  Always       -       10
  65.   7 Seek_Error_Rate         0x002e   200   200   000    Old_age   Always       -       0
  66.   9 Power_On_Hours          0x0032   095   095   000    Old_age   Always       -       3880
  67.  10 Spin_Retry_Count        0x0032   100   253   000    Old_age   Always       -       0
  68.  11 Calibration_Retry_Count 0x0032   100   253   000    Old_age   Always       -       0
  69.  12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       20
  70. 192 Power-Off_Retract_Count 0x0032   200   200   000    Old_age   Always       -       16
  71. 193 Load_Cycle_Count        0x0032   095   095   000    Old_age   Always       -       315088
  72. 194 Temperature_Celsius     0x0022   108   089   000    Old_age   Always       -       42
  73. 196 Reallocated_Event_Count 0x0032   190   190   000    Old_age   Always       -       10
  74. 197 Current_Pending_Sector  0x0032   198   198   000    Old_age   Always       -       919
  75. 198 Offline_Uncorrectable   0x0030   198   198   000    Old_age   Offline      -       758
  76. 199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age   Always       -       0
  77. 200 Multi_Zone_Error_Rate   0x0008   068   068   000    Old_age   Offline      -       35308
  78.  
  79. SMART Error Log Version: 1
  80. No Errors Logged
  81.  
  82. SMART Self-test log structure revision number 1
  83. No self-tests have been logged.  [To run self-tests, use: smartctl -t]
  84.  
  85.  
  86. SMART Selective self-test log data structure revision number 1
  87.  SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
  88.     1        0        0  Not_testing
  89.     2        0        0  Not_testing
  90.     3        0        0  Not_testing
  91.     4        0        0  Not_testing
  92.     5        0        0  Not_testing
  93. Selective self-test flags (0x0):
  94.   After scanning selected spans, do NOT read-scan remainder of disk.
  95. If Selective self-test is pending on power-up, resume after 0 minute delay.