- # smartctl -a -d megaraid,4 /dev/sda
- smartctl 6.4 2014-10-07 r4002 [x86_64-linux-3.14-2-amd64] (local build)
- Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
- /dev/sda [megaraid_disk_04] [SAT]: Device open changed type from 'megaraid,4' to 'sat+megaraid,4'
- === START OF INFORMATION SECTION ===
- Model Family: Intel 730 and DC S3500/S3700 Series SSDs
- Device Model: INTEL SSDSC2BB240G4
- Serial Number: BTWL40160422240NGN
- LU WWN Device Id: 5 5cd2e4 04b564d91
- Firmware Version: D2010370
- User Capacity: 240 057 409 536 bytes [240 GB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: Solid State Device
- Form Factor: 2.5 inches
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ACS-2 T13/2015-D revision 3
- SATA Version is: SATA 2.6, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Sun Feb 26 22:21:52 2017 MSK
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART Status not supported: ATA return descriptor not supported by controller firmware
- SMART overall-health self-assessment test result: PASSED
- Warning: This result is based on an Attribute check.
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 0) seconds.
- Offline data collection
- capabilities: (0x79) SMART execute Offline immediate.
- No Auto Offline data collection support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: ( 2) minutes.
- Conveyance self-test routine
- recommended polling time: ( 2) minutes.
- SCT capabilities: (0x003d) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 1
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 5 Reallocated_Sector_Ct 0x0032 100 100 000 Old_age Always - 0
- 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 21508
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 9
- 170 Available_Reservd_Space 0x0033 100 100 010 Pre-fail Always - 0
- 171 Program_Fail_Count 0x0032 100 100 000 Old_age Always - 0
- 172 Erase_Fail_Count 0x0032 100 100 000 Old_age Always - 0
- 174 Unsafe_Shutdown_Count 0x0032 100 100 000 Old_age Always - 7
- 175 Power_Loss_Cap_Test 0x0033 100 100 010 Pre-fail Always - 633 (127 2908)
- 183 SATA_Downshift_Count 0x0032 100 100 000 Old_age Always - 0
- 184 End-to-End_Error 0x0033 100 100 090 Pre-fail Always - 0
- 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
- 190 Temperature_Case 0x0022 081 071 000 Old_age Always - 19 (Min/Max 8/30)
- 192 Unsafe_Shutdown_Count 0x0032 100 100 000 Old_age Always - 7
- 194 Temperature_Internal 0x0022 100 100 000 Old_age Always - 28
- 197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 0
- 199 CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0
- 225 Host_Writes_32MiB 0x0032 100 100 000 Old_age Always - 14033330
- 226 Workld_Media_Wear_Indic 0x0032 100 100 000 Old_age Always - 102400
- 227 Workld_Host_Reads_Perc 0x0032 100 100 000 Old_age Always - 21
- 228 Workload_Minutes 0x0032 100 100 000 Old_age Always - 1290467
- 232 Available_Reservd_Space 0x0033 100 100 010 Pre-fail Always - 0
- 233 Media_Wearout_Indicator 0x0032 001 001 000 Old_age Always - 0
- 234 Thermal_Throttle 0x0032 100 100 000 Old_age Always - 0/0
- 241 Host_Writes_32MiB 0x0032 100 100 000 Old_age Always - 14033330
- 242 Host_Reads_32MiB 0x0032 100 100 000 Old_age Always - 3907570
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- No self-tests have been logged. [To run self-tests, use: smartctl -t]
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.
- root@ozyshop:/opt/MegaRAID/MegaCli# smartctl -a -d megaraid,5 /dev/sda
- smartctl 6.4 2014-10-07 r4002 [x86_64-linux-3.14-2-amd64] (local build)
- Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
- /dev/sda [megaraid_disk_05] [SAT]: Device open changed type from 'megaraid,5' to 'sat+megaraid,5'
- === START OF INFORMATION SECTION ===
- Model Family: Intel 730 and DC S3500/S3700 Series SSDs
- Device Model: INTEL SSDSC2BB240G4
- Serial Number: BTWL401603ZC240NGN
- LU WWN Device Id: 5 5cd2e4 04b564d3a
- Firmware Version: D2010370
- User Capacity: 240 057 409 536 bytes [240 GB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: Solid State Device
- Form Factor: 2.5 inches
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ACS-2 T13/2015-D revision 3
- SATA Version is: SATA 2.6, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Sun Feb 26 22:21:58 2017 MSK
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART Status not supported: ATA return descriptor not supported by controller firmware
- SMART overall-health self-assessment test result: PASSED
- Warning: This result is based on an Attribute check.
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 0) seconds.
- Offline data collection
- capabilities: (0x79) SMART execute Offline immediate.
- No Auto Offline data collection support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: ( 2) minutes.
- Conveyance self-test routine
- recommended polling time: ( 2) minutes.
- SCT capabilities: (0x003d) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 1
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 5 Reallocated_Sector_Ct 0x0032 100 100 000 Old_age Always - 0
- 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 21506
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 9
- 170 Available_Reservd_Space 0x0033 100 100 010 Pre-fail Always - 0
- 171 Program_Fail_Count 0x0032 100 100 000 Old_age Always - 0
- 172 Erase_Fail_Count 0x0032 100 100 000 Old_age Always - 0
- 174 Unsafe_Shutdown_Count 0x0032 100 100 000 Old_age Always - 7
- 175 Power_Loss_Cap_Test 0x0033 100 100 010 Pre-fail Always - 640 (127 2872)
- 183 SATA_Downshift_Count 0x0032 100 100 000 Old_age Always - 0
- 184 End-to-End_Error 0x0033 100 100 090 Pre-fail Always - 0
- 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
- 190 Temperature_Case 0x0022 081 071 000 Old_age Always - 19 (Min/Max 8/29)
- 192 Unsafe_Shutdown_Count 0x0032 100 100 000 Old_age Always - 7
- 194 Temperature_Internal 0x0022 100 100 000 Old_age Always - 28
- 197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 0
- 199 CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0
- 225 Host_Writes_32MiB 0x0032 100 100 000 Old_age Always - 14033340
- 226 Workld_Media_Wear_Indic 0x0032 100 100 000 Old_age Always - 102400
- 227 Workld_Host_Reads_Perc 0x0032 100 100 000 Old_age Always - 11
- 228 Workload_Minutes 0x0032 100 100 000 Old_age Always - 1290359
- 232 Available_Reservd_Space 0x0033 100 100 010 Pre-fail Always - 0
- 233 Media_Wearout_Indicator 0x0032 001 001 000 Old_age Always - 0
- 234 Thermal_Throttle 0x0032 100 100 000 Old_age Always - 0/0
- 241 Host_Writes_32MiB 0x0032 100 100 000 Old_age Always - 14033340
- 242 Host_Reads_32MiB 0x0032 100 100 000 Old_age Always - 1756472
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- No self-tests have been logged. [To run self-tests, use: smartctl -t]
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.