Advertisement
Not a member of Pastebin yet?
Sign Up,
it unlocks many cool features!
- ATA device, with non-removable media
- Model Number: FORESEE 120GB SSD
- Serial Number: G42863M001167
- Firmware Revision: V2.5
- Media Serial Num: MM32g16K4CF1MABS5200
- Media Manufacturer:
- Transport: Serial, ATA8-AST, SATA 1.0a, SATA II Extensions, SATA Rev 2.5, SATA Rev 2.6, SATA Rev 3.0
- Standards:
- Used: unknown (minor revision code 0x011b)
- Supported: 10 9 8 7 6 5
- Likely used: 10
- Configuration:
- Logical max current
- cylinders 16383 16383
- heads 16 16
- sectors/track 63 63
- --
- CHS current addressable sectors: 16514064
- LBA user addressable sectors: 234441648
- LBA48 user addressable sectors: 234441648
- Logical Sector size: 512 bytes
- Physical Sector size: 512 bytes
- Logical Sector-0 offset: 0 bytes
- device size with M = 1024*1024: 114473 MBytes
- device size with M = 1000*1000: 120034 MBytes (120 GB)
- cache/buffer size = unknown
- Nominal Media Rotation Rate: Solid State Device
- Capabilities:
- LBA, IORDY(can be disabled)
- Queue depth: 32
- Standby timer values: spec'd by Standard, no device specific minimum
- R/W multiple sector transfer: Max = 1 Current = ?
- Advanced power management level: disabled
- DMA: mdma0 mdma1 mdma2 udma0 udma1 udma2 udma3 udma4 udma5 *udma6
- Cycle time: min=120ns recommended=120ns
- PIO: pio0 pio1 pio2 pio3 pio4
- Cycle time: no flow control=120ns IORDY flow control=120ns
- Commands/features:
- Enabled Supported:
- * SMART feature set
- * Power Management feature set
- * Write cache
- * Look-ahead
- * WRITE_BUFFER command
- * READ_BUFFER command
- * NOP cmd
- * DOWNLOAD_MICROCODE
- Advanced Power Management feature set
- * 48-bit Address feature set
- * Mandatory FLUSH_CACHE
- * FLUSH_CACHE_EXT
- * General Purpose Logging feature set
- * WRITE_{DMA|MULTIPLE}_FUA_EXT
- * 64-bit World wide name
- * WRITE_UNCORRECTABLE_EXT command
- * {READ,WRITE}_DMA_EXT_GPL commands
- * Segmented DOWNLOAD_MICROCODE
- * Gen1 signaling speed (1.5Gb/s)
- * Gen2 signaling speed (3.0Gb/s)
- * Gen3 signaling speed (6.0Gb/s)
- * Native Command Queueing (NCQ)
- * unknown 76[13]
- * unknown 76[14]
- * unknown 76[15]
- * DMA Setup Auto-Activate optimization
- unknown 78[8]
- * WRITE BUFFER DMA command
- * READ BUFFER DMA command
- * Data Set Management TRIM supported (limit 8 blocks)
- * Deterministic read ZEROs after TRIM
- Security:
- 10min for SECURITY ERASE UNIT. 10min for ENHANCED SECURITY ERASE UNIT.
- Logical Unit WWN Device Identifier: 502a2a201b1c1b1a
- NAA : 5
- IEEE OUI : 02a2a2
- Unique ID : 01b1c1b1a
- Checksum: correct
Advertisement
Add Comment
Please, Sign In to add comment
Advertisement