- smartctl 5.43 2012-06-30 r3573 [x86_64-linux-2.6.32-504.el6.x86_64] (local build)
- Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net
- === START OF INFORMATION SECTION ===
- Device Model: TOSHIBA MK5065GSXF
- Serial Number: 31QZT32CT
- LU WWN Device Id: 5 000039 322105cca
- Firmware Version: GP005B
- User Capacity: 500,107,862,016 bytes [500 GB]
- Sector Size: 512 bytes logical/physical
- Device is: Not in smartctl database [for details use: -P showall]
- ATA Version is: 8
- ATA Standard is: Exact ATA specification draft version not indicated
- Local Time is: Mon Aug 31 17:08:28 2015 CEST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x02) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 249) Self-test routine in progress...
- 90% of test remaining.
- Total time to complete Offline
- data collection: ( 120) seconds.
- Offline data collection
- capabilities: (0x5b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- No Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 172) minutes.
- SCT capabilities: (0x003d) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0
- 2 Throughput_Performance 0x0005 100 100 050 Pre-fail Offline - 0
- 3 Spin_Up_Time 0x0027 100 100 001 Pre-fail Always - 2212
- 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 2747
- 5 Reallocated_Sector_Ct 0x0033 100 100 050 Pre-fail Always - 1523
- 7 Seek_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0
- 8 Seek_Time_Performance 0x0005 100 100 050 Pre-fail Offline - 0
- 9 Power_On_Hours 0x0032 087 087 000 Old_age Always - 5365
- 10 Spin_Retry_Count 0x0033 154 100 030 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 1524
- 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 8746
- 192 Power-Off_Retract_Count 0x0032 099 099 000 Old_age Always - 759
- 193 Load_Cycle_Count 0x0032 050 050 000 Old_age Always - 502733
- 194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 58 (Min/Max 8/58)
- 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 27
- 197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 524
- 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 1
- 220 Disk_Shift 0x0002 100 100 000 Old_age Always - 73
- 222 Loaded_Hours 0x0032 093 093 000 Old_age Always - 3122
- 223 Load_Retry_Count 0x0032 100 100 000 Old_age Always - 0
- 224 Load_Friction 0x0022 100 100 000 Old_age Always - 0
- 226 Load-in_Time 0x0026 100 100 000 Old_age Always - 331
- 240 Head_Flying_Hours 0x0001 100 100 001 Pre-fail Offline - 0
- 254 Free_Fall_Sensor 0x0032 100 100 000 Old_age Always - 548
- SMART Error Log Version: 1
- ATA Error Count: 59 (device log contains only the most recent five errors)
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 59 occurred at disk power-on lifetime: 5364 hours (223 days + 12 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 30 50 01 01 00 00 00
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- ff ff ff ff ff ff ff 0c 00:00:17.889 [VENDOR SPECIFIC]
- c8 ff 01 00 00 00 e0 00 00:00:15.085 READ DMA
- c8 ff 38 f8 12 01 e0 00 00:00:15.036 READ DMA
- c8 ff 38 c0 12 01 e0 00 00:00:15.035 READ DMA
- c8 ff 38 88 12 01 e0 00 00:00:15.035 READ DMA
- Error 58 occurred at disk power-on lifetime: 5364 hours (223 days + 12 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 30 50 01 01 00 00 00
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- ff ff ff ff ff ff ff 0c 00:00:09.914 [VENDOR SPECIFIC]
- c8 ff 77 7c 4a 08 e0 00 00:00:09.913 READ DMA
- c8 ff 7f fd 49 08 e0 00 00:00:09.912 READ DMA
- c8 ff 01 fc 49 08 e0 00 00:00:09.906 READ DMA
- c8 ff 01 00 00 00 e0 00 00:00:09.899 READ DMA
- Error 57 occurred at disk power-on lifetime: 5364 hours (223 days + 12 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 30 50 01 01 00 00 00
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- ff ff ff ff ff ff ff 0c 00:00:09.203 [VENDOR SPECIFIC]
- b0 da 00 00 4f c2 e0 00 00:00:08.972 SMART RETURN STATUS
- b0 d2 f1 00 4f c2 e0 00 00:00:08.972 SMART ENABLE/DISABLE ATTRIBUTE AUTOSAVE
- b0 d8 00 00 4f c2 e0 00 00:00:08.972 SMART ENABLE OPERATIONS
- 10 ff 50 14 3a 00 e0 00 00:00:08.952 RECALIBRATE [OBS-4]
- Error 56 occurred at disk power-on lifetime: 5364 hours (223 days + 12 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 30 50 01 01 00 00 00
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- ff ff ff ff ff ff ff 0c 00:00:36.186 [VENDOR SPECIFIC]
- c8 ff 01 00 00 00 e0 00 00:00:33.356 READ DMA
- c8 ff 38 f8 12 01 e0 00 00:00:33.305 READ DMA
- c8 ff 38 c0 12 01 e0 00 00:00:33.305 READ DMA
- c8 ff 38 88 12 01 e0 00 00:00:33.304 READ DMA
- Error 55 occurred at disk power-on lifetime: 5364 hours (223 days + 12 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 30 50 01 01 00 00 00
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- ff ff ff ff ff ff ff 0c 00:00:28.028 [VENDOR SPECIFIC]
- c8 ff 77 7c 4a 08 e0 00 00:00:28.027 READ DMA
- c8 ff 7f fd 49 08 e0 00 00:00:28.026 READ DMA
- c8 ff 01 fc 49 08 e0 00 00:00:28.020 READ DMA
- c8 ff 01 00 00 00 e0 00 00:00:27.989 READ DMA
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed without error 00% 5364 -
- # 2 Short offline Completed without error 00% 5364 -
- # 3 Short offline Completed without error 00% 5362 -
- # 4 Short offline Completed without error 00% 5362 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.