  1. === START OF INFORMATION SECTION ===
  2. Model Family: Seagate Barracuda 7200.11
  3. Device Model: ST31500341AS
  4. Serial Number: 9VS0BPPV
  5. LU WWN Device Id: 5 000c50 0105d25ac
  6. Firmware Version: LC1A
  7. User Capacity: 1,500,300,828,160 bytes [1.50 TB]
  8. Sector Size: 512 bytes logical/physical
  9. Device is: In smartctl database [for details use: -P show]
  10. ATA Version is: 8
  11. ATA Standard is: ATA-8-ACS revision 4
  12. Local Time is: Mon Sep 10 12:15:11 2012 MSK
  13.  
  14. ==> WARNING: There are known problems with these drives,
  15. see the following Seagate web pages:
  16. http://knowledge.seagate.com/articles/en_US/FAQ/207931en
  17. http://knowledge.seagate.com/articles/en_US/FAQ/207951en
  18. http://knowledge.seagate.com/articles/en_US/FAQ/207957en
  19.  
  20. SMART support is: Available - device has SMART capability.
  21. SMART support is: Enabled
  22.  
  23. === START OF READ SMART DATA SECTION ===
  24. SMART overall-health self-assessment test result: PASSED
  25.  
  26. General SMART Values:
  27. Offline data collection status: (0x82) Offline data collection activity
  28. was completed without error.
  29. Auto Offline Data Collection: Enabled.
  30. Self-test execution status: ( 0) The previous self-test routine completed
  31. without error or no self-test has ever
  32. been run.
  33. Total time to complete Offline
  34. data collection: ( 617) seconds.
  35. Offline data collection
  36. capabilities: (0x7b) SMART execute Offline immediate.
  37. Auto Offline data collection on/off support.
  38. Suspend Offline collection upon new
  39. command.
  40. Offline surface scan supported.
  41. Self-test supported.
  42. Conveyance Self-test supported.
  43. Selective Self-test supported.
  44. SMART capabilities: (0x0003) Saves SMART data before entering
  45. power-saving mode.
  46. Supports SMART auto save timer.
  47. Error logging capability: (0x01) Error logging supported.
  48. General Purpose Logging supported.
  49. Short self-test routine
  50. recommended polling time: ( 1) minutes.
  51. Extended self-test routine
  52. recommended polling time: ( 299) minutes.
  53. Conveyance self-test routine
  54. recommended polling time: ( 2) minutes.
  55. SCT capabilities: (0x103b) SCT Status supported.
  56. SCT Error Recovery Control supported.
  57. SCT Feature Control supported.
  58. SCT Data Table supported.
  59.  
  60. SMART Attributes Data Structure revision number: 10
  61. Vendor Specific SMART Attributes with Thresholds:
  62. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  63. 1 Raw_Read_Error_Rate 0x000f 116 090 006 Pre-fail Always - 107346388
  64. 3 Spin_Up_Time 0x0003 096 090 000 Pre-fail Always - 0
  65. 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 246
  66. 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 26
  67. 7 Seek_Error_Rate 0x000f 081 060 030 Pre-fail Always - 155322321
  68. 9 Power_On_Hours 0x0032 066 066 000 Old_age Always - 30396
  69. 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
  70. 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 294
  71. 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
  72. 187 Reported_Uncorrect 0x0032 001 001 000 Old_age Always - 1230
  73. 188 Command_Timeout 0x0032 100 098 000 Old_age Always - 30065229831
  74. 189 High_Fly_Writes 0x003a 001 001 000 Old_age Always - 571
  75. 190 Airflow_Temperature_Cel 0x0022 064 048 045 Old_age Always - 36 (Min/Max 35/40)
  76. 194 Temperature_Celsius 0x0022 036 052 000 Old_age Always - 36 (0 27 0 0 0)
  77. 195 Hardware_ECC_Recovered 0x001a 049 026 000 Old_age Always - 107346388
  78. 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 11
  79. 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 11
  80. 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
  81.  
  82. SMART Error Log Version: 1
  83. ATA Error Count: 1230 (device log contains only the most recent five errors)
  84. CR = Command Register [HEX]
  85. FR = Features Register [HEX]
  86. SC = Sector Count Register [HEX]
  87. SN = Sector Number Register [HEX]
  88. CL = Cylinder Low Register [HEX]
  89. CH = Cylinder High Register [HEX]
  90. DH = Device/Head Register [HEX]
  91. DC = Device Command Register [HEX]
  92. ER = Error register [HEX]
  93. ST = Status register [HEX]
  94. Powered_Up_Time is measured from power on, and printed as
  95. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  96. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  97.  
  98. Error 1230 occurred at disk power-on lifetime: 30327 hours (1263 days + 15 hours)
  99. When the command that caused the error occurred, the device was active or idle.
  100.  
  101. After command completion occurred, registers were:
  102. ER ST SC SN CL CH DH
  103. -- -- -- -- -- -- --
  104. 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
  105.  
  106. Commands leading to the command that caused the error were:
  107. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  108. -- -- -- -- -- -- -- -- ---------------- --------------------
  109. 60 00 00 ff ff ff 4f 00 8d+19:33:32.908 READ FPDMA QUEUED
  110. 60 00 00 ff ff ff 4f 00 8d+19:33:32.905 READ FPDMA QUEUED
  111. 60 00 00 ff ff ff 4f 00 8d+19:33:32.905 READ FPDMA QUEUED
  112. 60 00 00 ff ff ff 4f 00 8d+19:33:32.904 READ FPDMA QUEUED
  113. 60 00 00 ff ff ff 4f 00 8d+19:33:32.620 READ FPDMA QUEUED
  114.  
  115. Error 1229 occurred at disk power-on lifetime: 29791 hours (1241 days + 7 hours)
  116. When the command that caused the error occurred, the device was active or idle.
  117.  
  118. After command completion occurred, registers were:
  119. ER ST SC SN CL CH DH
  120. -- -- -- -- -- -- --
  121. 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
  122.  
  123. Commands leading to the command that caused the error were:
  124. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  125. -- -- -- -- -- -- -- -- ---------------- --------------------
  126. 60 00 08 ff ff ff 4f 00 2d+06:24:13.689 READ FPDMA QUEUED
  127. 60 00 08 ff ff ff 4f 00 2d+06:24:13.689 READ FPDMA QUEUED
  128. 60 00 08 ff ff ff 4f 00 2d+06:24:13.688 READ FPDMA QUEUED
  129. 60 00 08 ff ff ff 4f 00 2d+06:24:13.688 READ FPDMA QUEUED
  130. 60 00 08 ff ff ff 4f 00 2d+06:24:13.688 READ FPDMA QUEUED
  131.  
  132. Error 1228 occurred at disk power-on lifetime: 29791 hours (1241 days + 7 hours)
  133. When the command that caused the error occurred, the device was active or idle.
  134.  
  135. After command completion occurred, registers were:
  136. ER ST SC SN CL CH DH
  137. -- -- -- -- -- -- --
  138. 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
  139.  
  140. Commands leading to the command that caused the error were:
  141. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  142. -- -- -- -- -- -- -- -- ---------------- --------------------
  143. 60 00 00 ff ff ff 4f 00 2d+06:24:10.816 READ FPDMA QUEUED
  144. 60 00 20 ff ff ff 4f 00 2d+06:24:10.816 READ FPDMA QUEUED
  145. 60 00 e0 ff ff ff 4f 00 2d+06:24:10.815 READ FPDMA QUEUED
  146. 60 00 00 ff ff ff 4f 00 2d+06:24:10.795 READ FPDMA QUEUED
  147. 60 00 00 ff ff ff 4f 00 2d+06:24:10.793 READ FPDMA QUEUED
  148.  
  149. Error 1227 occurred at disk power-on lifetime: 29791 hours (1241 days + 7 hours)
  150. When the command that caused the error occurred, the device was active or idle.
  151.  
  152. After command completion occurred, registers were:
  153. ER ST SC SN CL CH DH
  154. -- -- -- -- -- -- --
  155. 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
  156.  
  157. Commands leading to the command that caused the error were:
  158. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  159. -- -- -- -- -- -- -- -- ---------------- --------------------
  160. 60 00 08 ff ff ff 4f 00 2d+06:20:27.976 READ FPDMA QUEUED
  161. 60 00 08 ff ff ff 4f 00 2d+06:20:27.976 READ FPDMA QUEUED
  162. 60 00 08 ff ff ff 4f 00 2d+06:20:27.975 READ FPDMA QUEUED
  163. 60 00 08 ff ff ff 4f 00 2d+06:20:27.975 READ FPDMA QUEUED
  164. 60 00 08 ff ff ff 4f 00 2d+06:20:27.975 READ FPDMA QUEUED
  165.  
  166. Error 1226 occurred at disk power-on lifetime: 29791 hours (1241 days + 7 hours)
  167. When the command that caused the error occurred, the device was active or idle.
  168.  
  169. After command completion occurred, registers were:
  170. ER ST SC SN CL CH DH
  171. -- -- -- -- -- -- --
  172. 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
  173.  
  174. Commands leading to the command that caused the error were:
  175. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  176. -- -- -- -- -- -- -- -- ---------------- --------------------
  177. 60 00 00 ff ff ff 4f 00 2d+06:20:25.136 READ FPDMA QUEUED
  178. 60 00 20 ff ff ff 4f 00 2d+06:20:25.136 READ FPDMA QUEUED
  179. 60 00 e0 ff ff ff 4f 00 2d+06:20:25.136 READ FPDMA QUEUED
  180. 60 00 00 ff ff ff 4f 00 2d+06:20:25.115 READ FPDMA QUEUED
  181. 60 00 00 ff ff ff 4f 00 2d+06:20:25.114 READ FPDMA QUEUED
  182.  
  183. SMART Self-test log structure revision number 1
  184. No self-tests have been logged. [To run self-tests, use: smartctl -t]
  185.  
  186.  
  187. SMART Selective self-test log data structure revision number 1
  188. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  189. 1 0 0 Not_testing
  190. 2 0 0 Not_testing
  191. 3 0 0 Not_testing
  192. 4 0 0 Not_testing
  193. 5 0 0 Not_testing
  194. Selective self-test flags (0x0):
  195. After scanning selected spans, do NOT read-scan remainder of disk.
  196. If Selective self-test is pending on power-up, resume after 0 minute delay.
Advertisement
Add Comment
Please, Sign In to add comment
Advertisement