  1. root@turris:~# smartctl --test=long /dev/sda
  2. smartctl 6.5 2016-05-07 r4318 [ppc-linux-4.4.103-10d3ee495c67f4b8dea965e37ab9cc62-1] (localbuild)
  3. Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
  4.  
  5. === START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION ===
  6. Sending command: "Execute SMART Extended self-test routine immediately in off-line mode".
  7. Drive command "Execute SMART Extended self-test routine immediately in off-line mode" successful.
  8. Testing has begun.
  9. Please wait 7 minutes for test to complete.
  10. Test will complete after Sat Dec 9 17:12:25 2017
  11.  
  12. Use smartctl -X to abort test.
  13. root@turris:~# smartctl --test=long /dev/sda
  14. smartctl 6.5 2016-05-07 r4318 [ppc-linux-4.4.103-10d3ee495c67f4b8dea965e37ab9cc62-1] (localbuild)
  15. Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
  16.  
  17. === START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION ===
  18. Sending command: "Execute SMART Extended self-test routine immediately in off-line mode".
  19. Drive command "Execute SMART Extended self-test routine immediately in off-line mode" successful.
  20. Testing has begun.
  21. Please wait 7 minutes for test to complete.
  22. Test will complete after Sat Dec 9 17:32:17 2017
  23.  
  24. Use smartctl -X to abort test.
  25.  
  26. root@turris:~# smartctl -x /dev/sda
  27. smartctl 6.5 2016-05-07 r4318 [ppc-linux-4.4.103-10d3ee495c67f4b8dea965e37ab9cc62-1] (localbuild)
  28. Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
  29.  
  30. === START OF INFORMATION SECTION ===
  31. Model Family: SanDisk based SSDs
  32. Device Model: SanDisk pSSD
  33. Serial Number: 0c0a50ba0
  34. LU WWN Device Id: 5 001b44 0a5c0a00b
  35. Firmware Version: 3
  36. User Capacity: 31,376,707,072 bytes [31.3 GB]
  37. Sector Size: 512 bytes logical/physical
  38. Rotation Rate: Solid State Device
  39. Form Factor: 1.8 inches
  40. Device is: In smartctl database [for details use: -P show]
  41. ATA Version is: ATA8-ACS T13/1699-D revision 2d
  42. SATA Version is: SATA 2.6, 6.0 Gb/s (current: 3.0 Gb/s)
  43. Local Time is: Sat Dec 9 17:25:26 2017 CET
  44. SMART support is: Available - device has SMART capability.
  45. SMART support is: Enabled
  46. AAM feature is: Unavailable
  47. APM feature is: Disabled
  48. Rd look-ahead is: Disabled
  49. Write cache is: Disabled
  50. ATA Security is: Disabled, NOT FROZEN [SEC1]
  51. Wt Cache Reorder: Unavailable
  52.  
  53. === START OF READ SMART DATA SECTION ===
  54. SMART overall-health self-assessment test result: PASSED
  55.  
  56. General SMART Values:
  57. Offline data collection status: (0x00) Offline data collection activity
  58. was never started.
  59. Auto Offline Data Collection: Disabled.
  60. Self-test execution status: ( 249) Self-test routine in progress...
  61. 90% of test remaining.
  62. Total time to complete Offline
  63. data collection: ( 120) seconds.
  64. Offline data collection
  65. capabilities: (0x51) SMART execute Offline immediate.
  66. No Auto Offline data collection support.
  67. Suspend Offline collection upon new
  68. command.
  69. No Offline surface scan supported.
  70. Self-test supported.
  71. No Conveyance Self-test supported.
  72. Selective Self-test supported.
  73. SMART capabilities: (0x0003) Saves SMART data before entering
  74. power-saving mode.
  75. Supports SMART auto save timer.
  76. Error logging capability: (0x01) Error logging supported.
  77. General Purpose Logging supported.
  78. Short self-test routine
  79. recommended polling time: ( 2) minutes.
  80. Extended self-test routine
  81. recommended polling time: ( 7) minutes.
  82.  
  83. SMART Attributes Data Structure revision number: 1
  84. Vendor Specific SMART Attributes with Thresholds:
  85. ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
  86. 5 Reallocated_Sector_Ct -O---- 100 100 000 - 0
  87. 9 Power_On_Hours -O---- 100 100 000 - 3987
  88. 12 Power_Cycle_Count -O---- 100 100 000 - 128
  89. 171 Program_Fail_Count -O---- 100 100 000 - 0
  90. 172 Erase_Fail_Count -O---- 100 100 000 - 0
  91. 173 Avg_Write/Erase_Count -O---- 100 100 000 - 1
  92. 174 Unexpect_Power_Loss_Ct -O---- 100 100 000 - 68
  93. 187 Reported_Uncorrect -O---- 100 100 000 - 0
  94. 230 Perc_Write/Erase_Count -O---- 100 100 000 - 3
  95. 232 Perc_Avail_Resrvd_Space PO---- 100 100 005 - 0
  96. 234 Perc_Write/Erase_Ct_BC -O---- 100 100 000 - 1
  97. 241 Total_LBAs_Written -O---- 100 100 000 - 79822202
  98. 242 Total_LBAs_Read -O---- 100 100 000 - 26642610
  99. ||||||_ K auto-keep
  100. |||||__ C event count
  101. ||||___ R error rate
  102. |||____ S speed/performance
  103. ||_____ O updated online
  104. |______ P prefailure warning
  105.  
  106. General Purpose Log Directory Version 1
  107. SMART Log Directory Version 1 [multi-sector log support]
  108. Address Access R/W Size Description
  109. 0x00 GPL,SL R/O 1 Log Directory
  110. 0x01 GPL,SL R/O 1 Summary SMART error log
  111. 0x03 GPL,SL R/O 16 Ext. Comprehensive SMART error log
  112. 0x04 GPL,SL R/O 8 Device Statistics log
  113. 0x06 GPL,SL R/O 1 SMART self-test log
  114. 0x09 GPL,SL R/W 1 Selective self-test log
  115. 0x10 GPL,SL R/O 1 SATA NCQ Queued Error log
  116. 0x11 GPL,SL R/O 1 SATA Phy Event Counters log
  117. 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
  118. 0x80-0x9f GPL,SL R/W 16 Host vendor specific log
  119. 0xa1 GPL,SL VS 1 Device vendor specific log
  120. 0xa2 GPL,SL VS 2 Device vendor specific log
  121. 0xa3 GPL,SL VS 1 Device vendor specific log
  122. 0xa7 GPL,SL VS 255 Device vendor specific log
  123.  
  124. Warning! SMART Extended Comprehensive Error Log Structure error: invalid SMART checksum.
  125. SMART Extended Comprehensive Error Log Version: 1 (16 sectors)
  126. No Errors Logged
  127.  
  128. SMART Extended Self-test Log (GP Log 0x07) not supported
  129.  
  130. SMART Self-test log structure revision number 1
  131. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  132. # 1 Extended offline Completed without error 90% 3987 -
  133.  
  134. SMART Selective self-test log data structure revision number 1
  135. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  136. 1 0 0 Not_testing
  137. 2 0 0 Not_testing
  138. 3 0 0 Not_testing
  139. 4 0 0 Not_testing
  140. 5 0 0 Not_testing
  141. Selective self-test flags (0x0):
  142. After scanning selected spans, do NOT read-scan remainder of disk.
  143. If Selective self-test is pending on power-up, resume after 0 minute delay.
  144.  
  145. SCT Commands not supported
  146.  
  147. Device Statistics (GP Log 0x04)
  148. Page Offset Size Value Flags Description
  149. 0x05 ===== = = === == Temperature Statistics (rev 1) ==
  150. 0x05 0x008 1 48 --- Current Temperature
  151. 0x05 0x010 1 - --- Average Short Term Temperature
  152. 0x05 0x018 1 - --- Average Long Term Temperature
  153. 0x05 0x020 1 61 --- Highest Temperature
  154. 0x05 0x028 1 30 --- Lowest Temperature
  155. 0x05 0x030 1 54 --- Highest Average Short Term Temperature
  156. 0x05 0x038 1 54 --- Lowest Average Short Term Temperature
  157. 0x05 0x040 1 - --- Highest Average Long Term Temperature
  158. 0x05 0x048 1 - --- Lowest Average Long Term Temperature
  159. 0x05 0x050 4 0 --- Time in Over-Temperature
  160. 0x05 0x058 1 95 --- Specified Maximum Operating Temperature
  161. 0x05 0x060 4 0 --- Time in Under-Temperature
  162. 0x05 0x068 1 0 --- Specified Minimum Operating Temperature
  163. 0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
  164. 0x07 0x008 1 0 N-- Percentage Used Endurance Indicator
  165. |||_ C monitored condition met
  166. ||__ D supports DSN
  167. |___ N normalized value
  168.  
  169. SATA Phy Event Counters (GP Log 0x11)
  170. ID Size Value Description
  171. 0x0003 2 0 R_ERR response for device-to-host data FIS
  172. 0x0004 2 0 R_ERR response for host-to-device data FIS
  173. 0x0006 2 0 R_ERR response for device-to-host non-data FIS
  174. 0x0007 2 0 R_ERR response for host-to-device non-data FIS
  175. 0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy
  176. 0x000a 2 0 Device-to-host register FISes sent due to a COMRESET
  177. 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
  178. 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
  179. 0x0001 2 0 Command failed due to ICRC error