- smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.13.0-32-generic] (local build)
- Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Seagate Momentus SpinPoint M8 (AF)
- Device Model: ST1000LM024 HN-M101MBB
- Serial Number: S2RQJ9CD225764
- LU WWN Device Id: 5 0004cf 209bed4d8
- Firmware Version: 2AR10002
- User Capacity: 1,000,204,886,016 bytes [1.00 TB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 5400 rpm
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ATA8-ACS T13/1699-D revision 6
- SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
- Local Time is: Thu Apr 28 22:07:31 2016 UTC
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 117) The previous self-test completed having
- the read element of the test failed.
- Total time to complete Offline
- data collection: (12840) seconds.
- Offline data collection
- capabilities: (0x5b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- No Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 214) minutes.
- SCT capabilities: (0x003f) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x002f 100 100 051 Pre-fail Always - 217
- 2 Throughput_Performance 0x0026 252 252 000 Old_age Always - 0
- 3 Spin_Up_Time 0x0023 089 088 025 Pre-fail Always - 3464
- 4 Start_Stop_Count 0x0032 096 096 000 Old_age Always - 4285
- 5 Reallocated_Sector_Ct 0x0033 252 252 010 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x002e 252 252 051 Old_age Always - 0
- 8 Seek_Time_Performance 0x0024 252 252 015 Old_age Offline - 0
- 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 13937
- 10 Spin_Retry_Count 0x0032 252 252 051 Old_age Always - 0
- 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 598
- 12 Power_Cycle_Count 0x0032 096 096 000 Old_age Always - 4271
- 191 G-Sense_Error_Rate 0x0022 100 100 000 Old_age Always - 1000
- 192 Power-Off_Retract_Count 0x0022 252 252 000 Old_age Always - 0
- 194 Temperature_Celsius 0x0002 064 056 000 Old_age Always - 36 (Min/Max 11/46)
- 195 Hardware_ECC_Recovered 0x003a 100 100 000 Old_age Always - 0
- 196 Reallocated_Event_Count 0x0032 252 252 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 2
- 198 Offline_Uncorrectable 0x0030 252 252 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0036 100 100 000 Old_age Always - 4
- 200 Multi_Zone_Error_Rate 0x002a 100 100 000 Old_age Always - 5453
- 223 Load_Retry_Count 0x0032 100 100 000 Old_age Always - 598
- 225 Load_Cycle_Count 0x0032 035 035 000 Old_age Always - 658614
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Extended offline Completed: read failure 50% 13937 1282614888
- # 2 Short offline Completed: read failure 90% 13935 1282614888
- SMART Selective self-test log data structure revision number 0
- Note: revision number not 1 implies that no selective self-test has ever been run
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Completed_read_failure [50% left] (0-65535)
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.