- smartctl 6.3 2014-07-26 r3976 [FreeBSD 9.3-RELEASE-p5 amd64] (local build)
- Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Seagate Barracuda Green (AF)
- Device Model: ST2000DL003-9VT166
- Serial Number: 5YD9ZEFZ
- LU WWN Device Id: 5 000c50 0531f6303
- Firmware Version: CC98
- User Capacity: 2,000,397,852,160 bytes [2.00 TB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 5900 rpm
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ATA8-ACS T13/1699-D revision 4
- SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
- Local Time is: Sun Dec 14 19:00:58 2014 EST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- See vendor-specific Attribute list for marginal Attributes.
- General SMART Values:
- Offline data collection status: (0x82) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 121) The previous self-test completed having
- the read element of the test failed.
- Total time to complete Offline
- data collection: ( 623) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off supp ort.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: ( 352) minutes.
- Conveyance self-test routine
- recommended polling time: ( 2) minutes.
- SCT capabilities: (0x1033) SCT Status supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 10
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_ FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 117 073 006 Pre-fail Always - 142590040
- 3 Spin_Up_Time 0x0003 093 092 000 Pre-fail Always - 0
- 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 309
- 5 Reallocated_Sector_Ct 0x0033 099 099 036 Pre-fail Always - 1192
- 7 Seek_Error_Rate 0x000f 075 060 030 Pre-fail Always - 37570353
- 9 Power_On_Hours 0x0032 079 079 000 Old_age Always - 18733
- 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 247
- 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0
- 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
- 187 Reported_Uncorrect 0x0032 001 001 000 Old_age Always - 21857
- 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0
- 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
- 190 Airflow_Temperature_Cel 0x0022 060 045 045 Old_age Always In_th e_past 40 (Min/Max 36/40)
- 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 0
- 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 184
- 193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 315
- 194 Temperature_Celsius 0x0022 040 055 000 Old_age Always - 40 (0 21 0 0 0)
- 195 Hardware_ECC_Recovered 0x001a 021 006 000 Old_age Always - 142590040
- 197 Current_Pending_Sector 0x0012 099 099 000 Old_age Always - 96
- 198 Offline_Uncorrectable 0x0010 099 099 000 Old_age Offline - 96
- 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
- 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 18762 (56 33 0)
- 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 3328526250
- 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 2168323910
- SMART Error Log Version: 1
- ATA Error Count: 21981 (device log contains only the most recent five errors)
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 21981 occurred at disk power-on lifetime: 18475 hours (769 days + 19 hours )
- When the command that caused the error occurred, the device was active or idle .
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 25 00 40 ff ff ff 4f 00 00:46:04.134 READ DMA EXT
- 25 00 40 ff ff ff 4f 00 00:46:00.795 READ DMA EXT
- 25 00 40 ff ff ff 4f 00 00:45:57.441 READ DMA EXT
- 25 00 40 ff ff ff 4f 00 00:45:54.102 READ DMA EXT
- 25 00 40 ff ff ff 4f 00 00:45:50.796 READ DMA EXT
- Error 21980 occurred at disk power-on lifetime: 18475 hours (769 days + 19 hours )
- When the command that caused the error occurred, the device was active or idle .
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 25 00 40 ff ff ff 4f 00 00:46:00.795 READ DMA EXT
- 25 00 40 ff ff ff 4f 00 00:45:57.441 READ DMA EXT
- 25 00 40 ff ff ff 4f 00 00:45:54.102 READ DMA EXT
- 25 00 40 ff ff ff 4f 00 00:45:50.796 READ DMA EXT
- c8 00 08 c0 17 3d ee 00 00:45:50.764 READ DMA
- Error 21979 occurred at disk power-on lifetime: 18475 hours (769 days + 19 hours )
- When the command that caused the error occurred, the device was active or idle .
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 25 00 40 ff ff ff 4f 00 00:45:57.441 READ DMA EXT
- 25 00 40 ff ff ff 4f 00 00:45:54.102 READ DMA EXT
- 25 00 40 ff ff ff 4f 00 00:45:50.796 READ DMA EXT
- c8 00 08 c0 17 3d ee 00 00:45:50.764 READ DMA
- 35 00 40 ff ff ff 4f 00 00:45:50.677 WRITE DMA EXT
- Error 21978 occurred at disk power-on lifetime: 18475 hours (769 days + 19 hours )
- When the command that caused the error occurred, the device was active or idle .
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 25 00 40 ff ff ff 4f 00 00:45:54.102 READ DMA EXT
- 25 00 40 ff ff ff 4f 00 00:45:50.796 READ DMA EXT
- c8 00 08 c0 17 3d ee 00 00:45:50.764 READ DMA
- 35 00 40 ff ff ff 4f 00 00:45:50.677 WRITE DMA EXT
- 35 00 40 ff ff ff 4f 00 00:45:50.677 WRITE DMA EXT
- Error 21977 occurred at disk power-on lifetime: 18475 hours (769 days + 19 hours )
- When the command that caused the error occurred, the device was active or idle .
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 25 00 40 ff ff ff 4f 00 00:45:50.796 READ DMA EXT
- c8 00 08 c0 17 3d ee 00 00:45:50.764 READ DMA
- 35 00 40 ff ff ff 4f 00 00:45:50.677 WRITE DMA EXT
- 35 00 40 ff ff ff 4f 00 00:45:50.677 WRITE DMA EXT
- 25 00 40 ff ff ff 4f 00 00:45:47.309 READ DMA EXT
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA _of_first_error
- # 1 Extended offline Completed: read failure 90% 18731 242 3759880
- # 2 Short offline Completed without error 00% 7914 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.