  1. smartctl 6.3 2014-07-26 r3976 [i686-linux-4.1.3-smp-wifislax] (local build)
  2. Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family: Western Digital Elements / My Passport (USB, AF)
  6. Device Model: WDC WD10TMVW-11ZSMS5
  7. Serial Number: WD-WXF1E61SJK41
  8. LU WWN Device Id: 5 0014ee 159b26f49
  9. Firmware Version: 01.01A01
  10. User Capacity: 1.000.204.886.016 bytes [1,00 TB]
  11. Sector Sizes: 512 bytes logical, 4096 bytes physical
  12. Rotation Rate: 5200 rpm
  13. Device is: In smartctl database [for details use: -P show]
  14. ATA Version is: ATA8-ACS (minor revision not indicated)
  15. SATA Version is: SATA 2.6, 3.0 Gb/s
  16. Local Time is: Mon Jun 27 04:27:17 2016 CEST
  17. SMART support is: Available - device has SMART capability.
  18. SMART support is: Enabled
  19.  
  20. === START OF READ SMART DATA SECTION ===
  21. SMART Status not supported: Incomplete response, ATA output registers missing
  22. SMART overall-health self-assessment test result: PASSED
  23. Warning: This result is based on an Attribute check.
  24.  
  25. General SMART Values:
  26. Offline data collection status: (0x00) Offline data collection activity
  27. was never started.
  28. Auto Offline Data Collection: Disabled.
  29. Self-test execution status: ( 0) The previous self-test routine completed
  30. without error or no self-test has ever
  31. been run.
  32. Total time to complete Offline
  33. data collection: (24900) seconds.
  34. Offline data collection
  35. capabilities: (0x7b) SMART execute Offline immediate.
  36. Auto Offline data collection on/off support.
  37. Suspend Offline collection upon new
  38. command.
  39. Offline surface scan supported.
  40. Self-test supported.
  41. Conveyance Self-test supported.
  42. Selective Self-test supported.
  43. SMART capabilities: (0x0003) Saves SMART data before entering
  44. power-saving mode.
  45. Supports SMART auto save timer.
  46. Error logging capability: (0x01) Error logging supported.
  47. General Purpose Logging supported.
  48. Short self-test routine
  49. recommended polling time: ( 2) minutes.
  50. Extended self-test routine
  51. recommended polling time: ( 242) minutes.
  52. Conveyance self-test routine
  53. recommended polling time: ( 5) minutes.
  54. SCT capabilities: (0x7035) SCT Status supported.
  55. SCT Feature Control supported.
  56. SCT Data Table supported.
  57.  
  58. SMART Attributes Data Structure revision number: 16
  59. Vendor Specific SMART Attributes with Thresholds:
  60. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  61. 1 Raw_Read_Error_Rate 0x002f 140 108 051 Pre-fail Always - 34636
  62. 3 Spin_Up_Time 0x0027 149 114 021 Pre-fail Always - 5508
  63. 4 Start_Stop_Count 0x0032 093 093 000 Old_age Always - 7494
  64. 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
  65. 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
  66. 9 Power_On_Hours 0x0032 093 093 000 Old_age Always - 5732
  67. 10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0
  68. 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0
  69. 12 Power_Cycle_Count 0x0032 094 094 000 Old_age Always - 6695
  70. 192 Power-Off_Retract_Count 0x0032 195 195 000 Old_age Always - 4367
  71. 193 Load_Cycle_Count 0x0032 190 190 000 Old_age Always - 31373
  72. 194 Temperature_Celsius 0x0022 116 109 000 Old_age Always - 34
  73. 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
  74. 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 3
  75. 198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0
  76. 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
  77. 200 Multi_Zone_Error_Rate 0x0008 100 253 000 Old_age Offline - 0
  78.  
  79. SMART Error Log Version: 1
  80. No Errors Logged
  81.  
  82. SMART Self-test log structure revision number 1
  83. No self-tests have been logged. [To run self-tests, use: smartctl -t]
  84.  
  85. SMART Selective self-test log data structure revision number 1
  86. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  87. 1 0 0 Not_testing
  88. 2 0 0 Not_testing
  89. 3 0 0 Not_testing
  90. 4 0 0 Not_testing
  91. 5 0 0 Not_testing
  92. Selective self-test flags (0x0):
  93. After scanning selected spans, do NOT read-scan remainder of disk.
  94. If Selective self-test is pending on power-up, resume after 0 minute delay.
Advertisement