  1. smartctl 5.40 2010-10-16 r3189 [x86_64-unknown-linux-gnu] (local build)
  2. Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family: Western Digital Caviar Blue Serial ATA family
  6. Device Model: WDC WD5000AAJS-22YFA0
  7. Serial Number: WD-WCAS80865334
  8. Firmware Version: 12.01C02
  9. User Capacity: 500,107,862,016 bytes
  10. Device is: In smartctl database [for details use: -P show]
  11. ATA Version is: 8
  12. ATA Standard is: Exact ATA specification draft version not indicated
  13. Local Time is: Wed Apr 20 13:00:08 2011 UTC
  14. SMART support is: Available - device has SMART capability.
  15. SMART support is: Enabled
  16.  
  17. === START OF READ SMART DATA SECTION ===
  18. SMART overall-health self-assessment test result: PASSED
  19.  
  20. General SMART Values:
  21. Offline data collection status: (0x85) Offline data collection activity
  22. was aborted by an interrupting command from host.
  23. Auto Offline Data Collection: Enabled.
  24. Self-test execution status: ( 0) The previous self-test routine completed
  25. without error or no self-test has ever
  26. been run.
  27. Total time to complete Offline
  28. data collection: (13200) seconds.
  29. Offline data collection
  30. capabilities: (0x7b) SMART execute Offline immediate.
  31. Auto Offline data collection on/off support.
  32. Suspend Offline collection upon new
  33. command.
  34. Offline surface scan supported.
  35. Self-test supported.
  36. Conveyance Self-test supported.
  37. Selective Self-test supported.
  38. SMART capabilities: (0x0003) Saves SMART data before entering
  39. power-saving mode.
  40. Supports SMART auto save timer.
  41. Error logging capability: (0x01) Error logging supported.
  42. General Purpose Logging supported.
  43. Short self-test routine
  44. recommended polling time: ( 2) minutes.
  45. Extended self-test routine
  46. recommended polling time: ( 154) minutes.
  47. Conveyance self-test routine
  48. recommended polling time: ( 5) minutes.
  49. SCT capabilities: (0x303f) SCT Status supported.
  50. SCT Error Recovery Control supported.
  51. SCT Feature Control supported.
  52. SCT Data Table supported.
  53.  
  54. SMART Attributes Data Structure revision number: 16
  55. Vendor Specific SMART Attributes with Thresholds:
  56. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  57. 1 Raw_Read_Error_Rate 0x000f 200 200 051 Pre-fail Always - 0
  58. 3 Spin_Up_Time 0x0003 235 172 021 Pre-fail Always - 3216
  59. 4 Start_Stop_Count 0x0032 097 097 000 Old_age Always - 3336
  60. 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
  61. 7 Seek_Error_Rate 0x000e 200 200 051 Old_age Always - 0
  62. 9 Power_On_Hours 0x0032 075 075 000 Old_age Always - 18338
  63. 10 Spin_Retry_Count 0x0012 100 100 051 Old_age Always - 0
  64. 11 Calibration_Retry_Count 0x0012 100 100 051 Old_age Always - 0
  65. 12 Power_Cycle_Count 0x0032 098 098 000 Old_age Always - 2875
  66. 192 Power-Off_Retract_Count 0x0032 198 198 000 Old_age Always - 1815
  67. 193 Load_Cycle_Count 0x0032 199 199 000 Old_age Always - 3337
  68. 194 Temperature_Celsius 0x0022 113 093 000 Old_age Always - 37
  69. 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
  70. 197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always - 0
  71. 198 Offline_Uncorrectable 0x0010 200 200 000 Old_age Offline - 0
  72. 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
  73. 200 Multi_Zone_Error_Rate 0x0008 200 200 051 Old_age Offline - 0
  74.  
  75. SMART Error Log Version: 1
  76. No Errors Logged
  77.  
  78. SMART Self-test log structure revision number 1
  79. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  80. # 1 Short offline Completed without error 00% 18338 -
  81.  
  82. SMART Selective self-test log data structure revision number 1
  83. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  84. 1 0 0 Not_testing
  85. 2 0 0 Not_testing
  86. 3 0 0 Not_testing
  87. 4 0 0 Not_testing
  88. 5 0 0 Not_testing