- smartctl 6.3 2014-07-26 r3976 [x86_64-apple-darwin14.0.0] (local build)
- Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Seagate Momentus XT
- Device Model: ST95005620AS
- Serial Number: 5YX10054
- LU WWN Device Id: 5 000c50 038511082
- Firmware Version: SD25
- User Capacity: 500 107 862 016 bytes [500 GB]
- Sector Size: 512 bytes logical/physical
- Rotation Rate: 7200 rpm
- Form Factor: 2.5 inches
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ATA8-ACS T13/1699-D revision 4
- SATA Version is: SATA 2.6, 3.0 Gb/s
- Local Time is: Fri Jan 30 03:30:21 2015 MSK
- ==> WARNING: These drives may corrupt large files,
- AND THIS FIRMWARE VERSION IS AFFECTED,
- see the following web pages for details:
- http://knowledge.seagate.com/articles/en_US/FAQ/215451en
- http://forums.seagate.com/t5/Momentus-XT-Momentus-Momentus/Momentus-XT-corrupting-large-files-Linux/td-p/109008
- http://superuser.com/questions/313447/seagate-momentus-xt-corrupting-files-linux-and-mac
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- See vendor-specific Attribute list for marginal Attributes.
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 634) seconds.
- Offline data collection
- capabilities: (0x73) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- No Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: ( 102) minutes.
- Conveyance self-test routine
- recommended polling time: ( 2) minutes.
- SCT capabilities: (0x1001) SCT Status supported.
- SMART Attributes Data Structure revision number: 10
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 118 099 006 Pre-fail Always - 169718083
- 3 Spin_Up_Time 0x0003 097 097 000 Pre-fail Always - 0
- 4 Start_Stop_Count 0x0032 095 095 020 Old_age Always - 5920
- 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x000f 084 060 030 Pre-fail Always - 323182668
- 9 Power_On_Hours 0x0032 087 087 000 Old_age Always - 11714
- 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 095 095 020 Old_age Always - 6116
- 184 End-to-End_Error 0x0032 099 099 099 Old_age Always FAILING_NOW 1
- 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
- 188 Command_Timeout 0x0032 100 253 000 Old_age Always - 0
- 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
- 190 Airflow_Temperature_Cel 0x0022 060 051 045 Old_age Always - 40 (Min/Max 25/40)
- 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 0
- 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 69
- 193 Load_Cycle_Count 0x0032 025 025 000 Old_age Always - 150235
- 194 Temperature_Celsius 0x0022 040 049 000 Old_age Always - 40 (0 16 0 0 0)
- 195 Hardware_ECC_Recovered 0x001a 041 033 000 Old_age Always - 169718083
- 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- No self-tests have been logged. [To run self-tests, use: smartctl -t]
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.