- smartctl 5.43 2012-06-30 r3573 [x86_64-linux-3.5.1-1.fc17.x86_64] (local build)
- Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net
- === START OF INFORMATION SECTION ===
- Model Family: Intel X18-M/X25-M/X25-V G2 SSDs
- Device Model: INTEL SSDSA1M160G2LE
- Serial Number: CVPO034600W4160CGN
- LU WWN Device Id: 5 001517 9593bce58
- Firmware Version: 2CV102L1
- User Capacity: 160,041,885,696 bytes [160 GB]
- Sector Size: 512 bytes logical/physical
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: 7
- ATA Standard is: ATA/ATAPI-7 T13 1532D revision 1
- Local Time is: Tue Aug 14 12:43:10 2012 MSK
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 1) seconds.
- Offline data collection
- capabilities: (0x71) SMART execute Offline immediate.
- No Auto Offline data collection support.
- Suspend Offline collection upon new
- command.
- No Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: ( 1) minutes.
- Conveyance self-test routine
- recommended polling time: ( 1) minutes.
- SMART Attributes Data Structure revision number: 5
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 3 Spin_Up_Time 0x0020 100 100 000 Old_age Offline - 0
- 4 Start_Stop_Count 0x0030 100 100 000 Old_age Offline - 0
- 5 Reallocated_Sector_Ct 0x0032 100 100 000 Old_age Always - 2
- 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 10098
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 1387
- 192 Unsafe_Shutdown_Count 0x0032 100 100 000 Old_age Always - 100
- 225 Host_Writes_32MiB 0x0030 100 100 000 Old_age Offline - 407703
- 226 Workld_Media_Wear_Indic 0x0032 100 100 000 Old_age Always - 1160
- 227 Workld_Host_Reads_Perc 0x0032 100 100 000 Old_age Always - 1
- 228 Workload_Minutes 0x0032 100 100 000 Old_age Always - 3392212260
- 232 Available_Reservd_Space 0x0033 100 100 010 Pre-fail Always - 0
- 233 Media_Wearout_Indicator 0x0032 097 097 000 Old_age Always - 0
- 184 End-to-End_Error 0x0033 100 100 090 Pre-fail Always - 0
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Vendor (0x70) Completed without error 00% 982 -
- # 2 Vendor (0xb8) Completed without error 00% 982 -
- Note: selective self-test log revision number (0) not 1 implies that no selective self-test has ever been run
- SMART Selective self-test log data structure revision number 0
- Note: revision number not 1 implies that no selective self-test has ever been run
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.
Advertisement
Add Comment
Please, Sign In to add comment
Advertisement