- $ sh dev/full
- Disk MISSY$DKA0:, device type IBM DXHS18Y, is online, mounted, file-oriented
- device, shareable, available to cluster, error logging is enabled.
- Error count 0 Operations completed 13123
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G:R,W
- Reference count 183 Default buffer size 512
- Total blocks 35566480 Sectors per track 32
- Total cylinders 34733 Tracks per cylinder 32
- Logical Volume Size 35566480 Expansion Size Limit 4261348350
- Volume label "MISSY" Relative volume number 0
- Cluster size 16 Transaction count 307
- Free blocks 21492304 Maximum files allowed 16711679
- Extend quantity 5 Mount count 1
- Mount status System Cache name "_MISSY$DKA0:XQPCACHE"
- Extent cache size 64 Max blocks in extent cache 2149230
- File ID cache size 64 Blocks in extent cache 286304
- Quota cache size 0 Maximum buffers in FCP cache 4110
- Volume owner UIC [1,1] Vol Prot S:RWCD,O:RWCD,G:RWCD,W:RWCD
- Volume Status: ODS-5, subject to mount verification, protected subsystems
- enabled, file high-water marking, write-through XFC caching enabled,
- write-through XQP caching enabled, hard links enabled, special files
- enabled.
- Disk MISSY$DKA200:, device type IBM DXHS18Y, is online, mounted, file-oriented
- device, shareable, available to cluster, error logging is enabled.
- Error count 0 Operations completed 419
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G:R,W
- Reference count 1 Default buffer size 512
- Total blocks 35566480 Sectors per track 32
- Total cylinders 34733 Tracks per cylinder 32
- Logical Volume Size 35566480 Expansion Size Limit 37552128
- Volume label "HOMES" Relative volume number 0
- Cluster size 48 Transaction count 1
- Free blocks 35565648 Maximum files allowed 362923
- Extend quantity 5 Mount count 1
- Mount status System Cache name "_MISSY$DKA0:XQPCACHE"
- Extent cache size 64 Max blocks in extent cache 3556564
- File ID cache size 64 Blocks in extent cache 0
- Quota cache size 0 Maximum buffers in FCP cache 4110
- Volume owner UIC [SYSTEM] Vol Prot S:RWCD,O:RWCD,G:RWCD,W:RWCD
- Volume Status: ODS-2, subject to mount verification, file high-water marking,
- write-through XFC caching enabled, write-back XQP caching enabled.
- Disk MISSY$DVA0:, device type RX26, is online, file-oriented device, shareable,
- available to cluster, error logging is enabled.
- Error count 0 Operations completed 125
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G:R,W
- Reference count 0 Default buffer size 512
- Total blocks 2880 Sectors per track 18
- Total cylinders 80 Tracks per cylinder 2
- Disk MISSY$DQA0:, device type TOSHIBA CD-ROM XM-6302B, is online, file-oriented
- device, shareable, available to cluster, error logging is enabled.
- Error count 0 Operations completed 23
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G:R,W
- Reference count 0 Default buffer size 512
- Total blocks 1349004 Sectors per track 34
- Total cylinders 1167 Tracks per cylinder 34
- Disk MISSY$DQA1:, device type Nonexistent IDE/ATAPI disk, is offline, unit timed
- out, device set /NOAVAILABLE, file-oriented device, shareable, error logging
- is enabled.
- Error count 1 Operations completed 1
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G:R,W
- Reference count 0 Default buffer size 512
- Total blocks 512 Sectors per track 4
- Total cylinders 26 Tracks per cylinder 5
- Disk MISSY$DQB0:, device type Nonexistent IDE/ATAPI disk, is offline, unit timed
- out, device set /NOAVAILABLE, file-oriented device, shareable, error logging
- is enabled.
- Error count 1 Operations completed 1
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G:R,W
- Reference count 0 Default buffer size 512
- Total blocks 512 Sectors per track 4
- Total cylinders 26 Tracks per cylinder 5
- Disk MISSY$DQB1:, device type Nonexistent IDE/ATAPI disk, is offline, unit timed
- out, device set /NOAVAILABLE, file-oriented device, shareable, error logging
- is enabled.
- Error count 1 Operations completed 1
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G:R,W
- Reference count 0 Default buffer size 512
- Total blocks 512 Sectors per track 4
- Total cylinders 26 Tracks per cylinder 5
- Disk MISSY$RCD0:, device type (type not yet identified), is offline, file-
- oriented device, shareable, device is a template only.
- Error count 0 Operations completed 0
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G:R,W
- Reference count 0 Default buffer size 512
- Total blocks 1440000 Sectors per track 4
- Total cylinders 60000 Tracks per cylinder 6
- Disk NFS0:, device type (type not yet identified), is online, file-oriented
- device, shareable, served to cluster via MSCP Server, device is a template
- only.
- Error count 0 Operations completed 0
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G:R,W
- Reference count 0 Default buffer size 512
- Magtape MISSY$RMT0:, device type (type not yet identified), is offline, file-
- oriented device, device is a template only.
- Error count 0 Operations completed 0
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G:R,W
- Reference count 0 Default buffer size 2048
- Density default Format Normal-11
- Volume status: no-unload on dismount, odd parity.
- Terminal OPA0:, device type unknown, is online, record-oriented device, carriage
- control.
- Error count 0 Operations completed 743
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G,W
- Reference count 0 Default buffer size 80
- Terminal OPA2:, device type unknown, is online, record-oriented device, carriage
- control.
- Error count 0 Operations completed 0
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G,W
- Reference count 0 Default buffer size 80
- Terminal OPA3:, device type unknown, is online, record-oriented device, carriage
- control.
- Error count 0 Operations completed 0
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G,W
- Reference count 0 Default buffer size 80
- Terminal FTA0:, device type unknown, is offline, device set /NOAVAILABLE,
- record-oriented device, carriage control.
- Error count 0 Operations completed 0
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G,W
- Reference count 0 Default buffer size 80
- Terminal TTA0:, device type unknown, is online, record-oriented device, carriage
- control.
- Error count 0 Operations completed 0
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G,W
- Reference count 0 Default buffer size 80
- Terminal TTB0:, device type unknown, is online, record-oriented device, carriage
- control.
- Error count 0 Operations completed 0
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G,W
- Reference count 0 Default buffer size 80
- Terminal RTA0:, device type unknown, is offline, device set /NOAVAILABLE,
- record-oriented device, carriage control.
- Error count 0 Operations completed 0
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G,W
- Reference count 0 Default buffer size 80
- Terminal RTA1:, device type VT100, is online, mounted, record-oriented device,
- carriage control.
- Error count 0 Operations completed 4285
- Owner process "SYSTEM" Owner UIC [SYSTEM]
- Owner process ID 00000424 Dev Prot S:RWPL,O:RWPL,G,W
- Reference count 2 Default buffer size 195
- Terminal RTB0:, device type unknown, is offline, device set /NOAVAILABLE,
- record-oriented device, carriage control.
- Error count 0 Operations completed 0
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G,W
- Reference count 0 Default buffer size 80
- Terminal NTY0:, device type unknown, is online, record-oriented device, carriage
- control, device is a template only.
- Error count 0 Operations completed 0
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G,W
- Reference count 0 Default buffer size 80
- Printer LRA0:, device type LP11, is online, record-oriented device, carriage
- control.
- Error count 0 Operations completed 0
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G,W
- Reference count 0 Default buffer size 132
- Page width 132 Page Length 66
- No Carriage_return Formfeed Uppercase
- No Passall No Wrap No Printall
- No Fallback No Tab Truncate
- No Sixels No Bitmapped No Polled
- Unidirectional
- Device PKA0:, device type SYM53C895 LVD SCSI, is online, error logging is
- enabled.
- Error count 0 Operations completed 38
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G,W
- Reference count 0 Default buffer size 0
- Device MPA0:, device type unknown, is online, record-oriented device, device is
- a template only.
- Error count 0 Operations completed 0
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G:RWPL,W:RWPL
- Reference count 0 Default buffer size 256
- Device PKB0:, device type Qlogic ISP1020 SCSI port, is online, error logging is
- enabled.
- Error count 0 Operations completed 24
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G,W
- Reference count 0 Default buffer size 65535
- Current preferred CPU Id 3 Fastpath 1
- Current Interrupt CPU Id 3
- Device PKC0:, device type Qlogic ISP1020 SCSI port, is online, error logging is
- enabled.
- Error count 0 Operations completed 24
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G,W
- Reference count 0 Default buffer size 65535
- Current preferred CPU Id 2 Fastpath 1
- Current Interrupt CPU Id 2
- Device PKD0:, device type Qlogic ISP1020 SCSI port, is online, error logging is
- enabled.
- Error count 0 Operations completed 24
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G,W
- Reference count 0 Default buffer size 65535
- Current preferred CPU Id 1 Fastpath 1
- Current Interrupt CPU Id 1
- Device FGA0:, device type KGPSA Fibre Channel, is online, shareable, error
- logging is enabled.
- Error count 3 Operations completed 0
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G,W
- Reference count 0 Default buffer size 0
- Current preferred CPU Id 0 Fastpath 1
- Current Interrupt CPU Id 0
- FC Port Name 1000-0000-C925-95C7 FC Node Name 2000-0000-C925-95C7
- Device PGA0:, device type SCSI FCP, is online, error logging is enabled.
- Error count 0 Operations completed 16
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G,W
- Reference count 0 Default buffer size 65535
- Current preferred CPU Id 0 Fastpath 1
- Device EWA0:, device type DE500, is online, network device, error logging is
- enabled, device is a template only.
- Error count 1 Operations completed 0
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G,W
- Reference count 0 Default buffer size 512
- Current preferred CPU Id 3 Fastpath 1
- Current Interrupt CPU Id 3
- Operating characteristics: Link up, Full duplex.
- Speed (Mbits/sec) 100
- Def. MAC addr 08-00-2B-C3-2E-A5 Current MAC addr AA-00-04-00-03-24
- Device EWA3:, device type DE500, is online, network device, error logging is
- enabled.
- Error count 0 Operations completed 6570
- Owner process "NETACP" Owner UIC [SYSTEM]
- Owner process ID 0000041C Dev Prot S:RWPL,O:RWPL,G,W
- Reference count 2 Default buffer size 1498
- Operating characteristics: Full duplex.
- Speed (Mbits/sec) 100
- Def. MAC addr 08-00-2B-C3-2E-A5 Current MAC addr AA-00-04-00-03-24
- Protocol name DECNET Protocol type 60-03
- Device EWA5:, device type DE500, is online, network device, error logging is
- enabled.
- Error count 0 Operations completed 0
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G,W
- Reference count 1 Default buffer size 1500
- Operating characteristics: Full duplex.
- Speed (Mbits/sec) 100
- Def. MAC addr 08-00-2B-C3-2E-A5 Current MAC addr AA-00-04-00-03-24
- Protocol name IP Protocol type 08-00
- Device EWA7:, device type DE500, is online, network device, error logging is
- enabled.
- Error count 0 Operations completed 0
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G,W
- Reference count 1 Default buffer size 1500
- Operating characteristics: Full duplex.
- Speed (Mbits/sec) 100
- Def. MAC addr 08-00-2B-C3-2E-A5 Current MAC addr AA-00-04-00-03-24
- Protocol name ARP Protocol type 08-06
- Device GZA0:, device type DECwindows output device, is offline, record-oriented
- device, carriage control, shareable.
- Error count 0 Operations completed 0
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G:RWPL,W:RWPL
- Reference count 0 Default buffer size 0
- Device FGB0:, device type KGPSA Fibre Channel, is online, shareable, error
- logging is enabled.
- Error count 3 Operations completed 0
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G,W
- Reference count 0 Default buffer size 0
- Current preferred CPU Id 2 Fastpath 1
- Current Interrupt CPU Id 2
- FC Port Name 1000-0000-C922-6965 FC Node Name 2000-0000-C922-6965
- Device PGB0:, device type SCSI FCP, is online, error logging is enabled.
- Error count 0 Operations completed 16
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G,W
- Reference count 0 Default buffer size 65535
- Current preferred CPU Id 2 Fastpath 1
- Device PKE0:, device type Qlogic ISP1020 SCSI port, is online, error logging is
- enabled.
- Error count 0 Operations completed 24
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G,W
- Reference count 0 Default buffer size 65535
- Current preferred CPU Id 1 Fastpath 1
- Current Interrupt CPU Id 1
- Device EWB0:, device type DE500, is online, network device, error logging is
- enabled, device is a template only.
- Error count 0 Operations completed 0
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G,W
- Reference count 0 Default buffer size 512
- Current preferred CPU Id 0 Fastpath 1
- Current Interrupt CPU Id 0
- Operating characteristics: Link down, Full duplex.
- Speed (Mbits/sec) 100
- Def. MAC addr 08-00-2B-C4-4F-14 Current MAC addr AA-00-04-00-03-24
- Device EWB2:, device type DE500, is online, network device, error logging is
- enabled.
- Error count 0 Operations completed 1608
- Owner process "NETACP" Owner UIC [SYSTEM]
- Owner process ID 0000041C Dev Prot S:RWPL,O:RWPL,G,W
- Reference count 2 Default buffer size 1498
- Operating characteristics: Full duplex.
- Speed (Mbits/sec) 100
- Def. MAC addr 08-00-2B-C4-4F-14 Current MAC addr AA-00-04-00-03-24
- Protocol name DECNET Protocol type 60-03
- Device PWIP0:, device type unknown, is online, error logging is enabled, device
- is a template only.
- Error count 0 Operations completed 0
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G:RWPL,W:RWPL
- Reference count 0 Default buffer size 65535
- Device LAV0:, device type unknown, is online, record-oriented device, shareable.
- Error count 0 Operations completed 0
- Owner process "" Owner UIC [SYSTEM]
- Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G:RWPL,W:RWPL
- Reference count 0 Default buffer size 36
- Device SMA0:, device type unknown, is online.
- Error count 0 Operations completed 2
- Owner process "SMHANDLER" Owner UIC [SYSTEM]
- Owner process ID 00000421 Dev Prot S:RWPL,O:RWPL,G:RWPL,W:RWPL
- Reference count 1 Default buffer size 256
- $