Advertisement
ameel

Untitled

Jan 25th, 2013
11
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 9.17 KB | None | 0 0
  1. smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.2.0-29-generic] (local build)
  2. Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family: Hitachi Deskstar 7K3000
  6. Device Model: Hitachi HDS723020BLA642
  7. Serial Number: MN1220F320W9XD
  8. LU WWN Device Id: 5 000cca 369dc9590
  9. Firmware Version: MN6OA5C0
  10. User Capacity: 2,000,398,934,016 bytes [2.00 TB]
  11. Sector Size: 512 bytes logical/physical
  12. Device is: In smartctl database [for details use: -P show]
  13. ATA Version is: 8
  14. ATA Standard is: ATA-8-ACS revision 4
  15. Local Time is: Fri Jan 25 19:08:10 2013 EST
  16. SMART support is: Available - device has SMART capability.
  17. SMART support is: Enabled
  18.  
  19. === START OF READ SMART DATA SECTION ===
  20. SMART overall-health self-assessment test result: PASSED
  21.  
  22. General SMART Values:
  23. Offline data collection status: (0x82) Offline data collection activity
  24. was completed without error.
  25. Auto Offline Data Collection: Enabled.
  26. Self-test execution status: ( 0) The previous self-test routine completed
  27. without error or no self-test has ever
  28. been run.
  29. Total time to complete Offline
  30. data collection: (18238) seconds.
  31. Offline data collection
  32. capabilities: (0x5b) SMART execute Offline immediate.
  33. Auto Offline data collection on/off support.
  34. Suspend Offline collection upon new
  35. command.
  36. Offline surface scan supported.
  37. Self-test supported.
  38. No Conveyance Self-test supported.
  39. Selective Self-test supported.
  40. SMART capabilities: (0x0003) Saves SMART data before entering
  41. power-saving mode.
  42. Supports SMART auto save timer.
  43. Error logging capability: (0x01) Error logging supported.
  44. General Purpose Logging supported.
  45. Short self-test routine
  46. recommended polling time: ( 1) minutes.
  47. Extended self-test routine
  48. recommended polling time: ( 255) minutes.
  49. SCT capabilities: (0x003d) SCT Status supported.
  50. SCT Error Recovery Control supported.
  51. SCT Feature Control supported.
  52. SCT Data Table supported.
  53.  
  54. SMART Attributes Data Structure revision number: 16
  55. Vendor Specific SMART Attributes with Thresholds:
  56. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  57. 1 Raw_Read_Error_Rate 0x000b 100 100 016 Pre-fail Always - 0
  58. 2 Throughput_Performance 0x0005 136 136 054 Pre-fail Offline - 83
  59. 3 Spin_Up_Time 0x0007 160 160 024 Pre-fail Always - 361 (Average 356)
  60. 4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 44
  61. 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 0
  62. 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0
  63. 8 Seek_Time_Performance 0x0005 135 135 020 Pre-fail Offline - 26
  64. 9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 4228
  65. 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0
  66. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 44
  67. 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 147
  68. 193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always - 147
  69. 194 Temperature_Celsius 0x0002 157 157 000 Old_age Always - 38 (Min/Max 21/67)
  70. 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
  71. 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 10
  72. 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0
  73. 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0
  74.  
  75. SMART Error Log Version: 1
  76. ATA Error Count: 43 (device log contains only the most recent five errors)
  77. CR = Command Register [HEX]
  78. FR = Features Register [HEX]
  79. SC = Sector Count Register [HEX]
  80. SN = Sector Number Register [HEX]
  81. CL = Cylinder Low Register [HEX]
  82. CH = Cylinder High Register [HEX]
  83. DH = Device/Head Register [HEX]
  84. DC = Device Command Register [HEX]
  85. ER = Error register [HEX]
  86. ST = Status register [HEX]
  87. Powered_Up_Time is measured from power on, and printed as
  88. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  89. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  90.  
  91. Error 43 occurred at disk power-on lifetime: 3754 hours (156 days + 10 hours)
  92. When the command that caused the error occurred, the device was active or idle.
  93.  
  94. After command completion occurred, registers were:
  95. ER ST SC SN CL CH DH
  96. -- -- -- -- -- -- --
  97. 40 51 2f 09 a8 15 00 Error: UNC at LBA = 0x0015a809 = 1419273
  98.  
  99. Commands leading to the command that caused the error were:
  100. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  101. -- -- -- -- -- -- -- -- ---------------- --------------------
  102. 60 50 00 e8 a7 15 40 00 2d+14:01:42.369 READ FPDMA QUEUED
  103. 60 30 00 b8 a7 15 40 00 2d+14:01:42.369 READ FPDMA QUEUED
  104. 60 08 00 b0 a7 15 40 00 2d+14:01:42.369 READ FPDMA QUEUED
  105. 60 98 00 18 a7 15 40 00 2d+14:01:42.363 READ FPDMA QUEUED
  106. 60 00 00 18 a3 15 40 00 2d+14:01:42.361 READ FPDMA QUEUED
  107.  
  108. Error 42 occurred at disk power-on lifetime: 2985 hours (124 days + 9 hours)
  109. When the command that caused the error occurred, the device was active or idle.
  110.  
  111. After command completion occurred, registers were:
  112. ER ST SC SN CL CH DH
  113. -- -- -- -- -- -- --
  114. 40 51 00 00 dc 49 0b Error: UNC at LBA = 0x0b49dc00 = 189389824
  115.  
  116. Commands leading to the command that caused the error were:
  117. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  118. -- -- -- -- -- -- -- -- ---------------- --------------------
  119. 60 80 08 00 e0 49 40 00 1d+07:10:29.650 READ FPDMA QUEUED
  120. 60 00 00 00 dc 49 40 00 1d+07:10:29.650 READ FPDMA QUEUED
  121. 60 00 00 00 d0 49 40 00 1d+07:10:19.123 READ FPDMA QUEUED
  122. 60 00 08 00 cc 49 40 00 1d+07:10:08.801 READ FPDMA QUEUED
  123. 60 00 00 00 c8 49 40 00 1d+07:10:08.801 READ FPDMA QUEUED
  124.  
  125. Error 41 occurred at disk power-on lifetime: 2985 hours (124 days + 9 hours)
  126. When the command that caused the error occurred, the device was active or idle.
  127.  
  128. After command completion occurred, registers were:
  129. ER ST SC SN CL CH DH
  130. -- -- -- -- -- -- --
  131. 40 51 fd 03 c4 48 0b Error: UNC at LBA = 0x0b48c403 = 189318147
  132.  
  133. Commands leading to the command that caused the error were:
  134. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  135. -- -- -- -- -- -- -- -- ---------------- --------------------
  136. 60 00 00 00 c4 48 40 00 1d+07:03:17.145 READ FPDMA QUEUED
  137. 60 00 00 00 b8 48 40 00 1d+07:03:04.086 READ FPDMA QUEUED
  138. 60 00 08 00 b4 48 40 00 1d+07:02:45.309 READ FPDMA QUEUED
  139. 60 00 00 00 b0 48 40 00 1d+07:02:45.309 READ FPDMA QUEUED
  140. 60 00 08 00 ac 48 40 00 1d+07:02:26.121 READ FPDMA QUEUED
  141.  
  142. Error 40 occurred at disk power-on lifetime: 2613 hours (108 days + 21 hours)
  143. When the command that caused the error occurred, the device was active or idle.
  144.  
  145. After command completion occurred, registers were:
  146. ER ST SC SN CL CH DH
  147. -- -- -- -- -- -- --
  148. 40 51 3f 01 28 a6 05 Error: UNC at LBA = 0x05a62801 = 94775297
  149.  
  150. Commands leading to the command that caused the error were:
  151. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  152. -- -- -- -- -- -- -- -- ---------------- --------------------
  153. 60 f8 20 08 2a a6 40 00 4d+05:16:22.694 READ FPDMA QUEUED
  154. 60 d8 18 28 29 a6 40 00 4d+05:16:22.693 READ FPDMA QUEUED
  155. 60 d8 00 48 28 a6 40 00 4d+05:16:22.693 READ FPDMA QUEUED
  156. 60 40 10 00 28 a6 40 00 4d+05:16:22.693 READ FPDMA QUEUED
  157. 60 90 08 70 26 a6 40 00 4d+05:16:22.692 READ FPDMA QUEUED
  158.  
  159. Error 39 occurred at disk power-on lifetime: 2251 hours (93 days + 19 hours)
  160. When the command that caused the error occurred, the device was active or idle.
  161.  
  162. After command completion occurred, registers were:
  163. ER ST SC SN CL CH DH
  164. -- -- -- -- -- -- --
  165. 40 51 7f 01 a4 8c 09 Error: UNC at LBA = 0x098ca401 = 160211969
  166.  
  167. Commands leading to the command that caused the error were:
  168. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  169. -- -- -- -- -- -- -- -- ---------------- --------------------
  170. 60 28 00 58 a3 8c 40 00 1d+10:16:46.501 READ FPDMA QUEUED
  171. 60 00 00 58 a2 8c 40 00 1d+10:16:46.501 READ FPDMA QUEUED
  172. 60 90 00 c8 a1 8c 40 00 1d+10:16:46.500 READ FPDMA QUEUED
  173. 60 28 00 a0 a1 8c 40 00 1d+10:16:46.500 READ FPDMA QUEUED
  174. 60 08 00 98 a1 8c 40 00 1d+10:16:46.500 READ FPDMA QUEUED
  175.  
  176. SMART Self-test log structure revision number 1
  177. No self-tests have been logged. [To run self-tests, use: smartctl -t]
  178.  
  179.  
  180. SMART Selective self-test log data structure revision number 1
  181. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  182. 1 0 0 Not_testing
  183. 2 0 0 Not_testing
  184. 3 0 0 Not_testing
  185. 4 0 0 Not_testing
  186. 5 0 0 Not_testing
  187. Selective self-test flags (0x0):
  188. After scanning selected spans, do NOT read-scan remainder of disk.
  189. If Selective self-test is pending on power-up, resume after 0 minute delay.
Advertisement