  1. smartctl 5.41 2011-06-09 r3365 [i686-linux-3.0.4-pmagic] (local build)
  2. Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family:     Western Digital Caviar Blue Serial ATA
  6. Device Model:     WDC WD1600AAJS-00L7A0
  7. Serial Number:    WD-WMAV36285716
  8. LU WWN Device Id: 5 0014ee 0014e961c
  9. Firmware Version: 01.03E01
  10. User Capacity:    160,041,885,696 bytes [160 GB]
  11. Sector Size:      512 bytes logical/physical
  12. Device is:        In smartctl database [for details use: -P show]
  13. ATA Version is:   8
  14. ATA Standard is:  Exact ATA specification draft version not indicated
  15. Local Time is:    Sat Mar 17 11:37:45 2012 UTC
  16. SMART support is: Available - device has SMART capability.
  17. SMART support is: Enabled
  18.  
  19. === START OF READ SMART DATA SECTION ===
  20. SMART overall-health self-assessment test result: PASSED
  21.  
  22. General SMART Values:
  23. Offline data collection status:  (0x85) Offline data collection activity
  24.                                         was aborted by an interrupting command from host.
  25.                                         Auto Offline Data Collection: Enabled.
  26. Self-test execution status:      ( 121) The previous self-test completed having
  27.                                         the read element of the test failed.
  28. Total time to complete Offline
  29. data collection:                ( 3060) seconds.
  30. Offline data collection
  31. capabilities:                    (0x7b) SMART execute Offline immediate.
  32.                                         Auto Offline data collection on/off support.
  33.                                         Suspend Offline collection upon new
  34.                                         command.
  35.                                         Offline surface scan supported.
  36.                                         Self-test supported.
  37.                                         Conveyance Self-test supported.
  38.                                         Selective Self-test supported.
  39. SMART capabilities:            (0x0003) Saves SMART data before entering
  40.                                         power-saving mode.
  41.                                         Supports SMART auto save timer.
  42. Error logging capability:        (0x01) Error logging supported.
  43.                                         General Purpose Logging supported.
  44. Short self-test routine
  45. recommended polling time:        (   2) minutes.
  46. Extended self-test routine
  47. recommended polling time:        (  40) minutes.
  48. Conveyance self-test routine
  49. recommended polling time:        (   5) minutes.
  50. SCT capabilities:              (0x303f) SCT Status supported.
  51.                                         SCT Error Recovery Control supported.
  52.                                         SCT Feature Control supported.
  53.                                         SCT Data Table supported.
  54.  
  55. SMART Attributes Data Structure revision number: 16
  56. Vendor Specific SMART Attributes with Thresholds:
  57. ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  58.   1 Raw_Read_Error_Rate     0x002f   200   200   051    Pre-fail  Always       -       113
  59.   3 Spin_Up_Time            0x0027   141   133   021    Pre-fail  Always       -       3908
  60.   4 Start_Stop_Count        0x0032   097   097   000    Old_age   Always       -       3011
  61.   5 Reallocated_Sector_Ct   0x0033   200   200   140    Pre-fail  Always       -       0
  62.   7 Seek_Error_Rate         0x002e   100   253   000    Old_age   Always       -       0
  63.   9 Power_On_Hours          0x0032   089   089   000    Old_age   Always       -       8337
  64.  10 Spin_Retry_Count        0x0032   100   100   000    Old_age   Always       -       0
  65.  11 Calibration_Retry_Count 0x0032   100   100   000    Old_age   Always       -       0
  66.  12 Power_Cycle_Count       0x0032   098   098   000    Old_age   Always       -       2793
  67. 192 Power-Off_Retract_Count 0x0032   200   200   000    Old_age   Always       -       193
  68. 193 Load_Cycle_Count        0x0032   199   199   000    Old_age   Always       -       3011
  69. 194 Temperature_Celsius     0x0022   101   092   000    Old_age   Always       -       42
  70. 196 Reallocated_Event_Count 0x0032   200   200   000    Old_age   Always       -       0
  71. 197 Current_Pending_Sector  0x0032   200   200   000    Old_age   Always       -       1
  72. 198 Offline_Uncorrectable   0x0030   200   200   000    Old_age   Offline      -       1
  73. 199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age   Always       -       0
  74. 200 Multi_Zone_Error_Rate   0x0008   200   200   000    Old_age   Offline      -       1
  75.  
  76. SMART Error Log Version: 1
  77. No Errors Logged
  78.  
  79. SMART Self-test log structure revision number 1
  80. Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
  81. # 1  Short offline       Completed: read failure       90%      8337         67681711
  82.  
  83. SMART Selective self-test log data structure revision number 1
  84.  SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
  85.     1        0        0  Not_testing
  86.     2        0        0  Not_testing
  87.     3        0        0  Not_testing
  88.     4        0        0  Not_testing
  89.     5        0        0  Not_testing
  90. Selective self-test flags (0x0):
  91.   After scanning selected spans, do NOT read-scan remainder of disk.
  92. If Selective self-test is pending on power-up, resume after 0 minute delay.