Advertisement
Guest User

Untitled

a guest
Mar 29th, 2015
237
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 6.82 KB | None | 0 0
  1. kerrigan@nocturna~$ smartctl -a /dev/sdc
  2. smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.16.0-34-generic] (local build)
  3. Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
  4.  
  5. Smartctl open device: /dev/sdc [USB JMicron] failed: Permission denied
  6. kerrigan@nocturna~$ sudo smartctl -a /dev/sdc
  7. smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.16.0-34-generic] (local build)
  8. Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
  9.  
  10. === START OF INFORMATION SECTION ===
  11. Model Family: SAMSUNG SpinPoint M7E (AF)
  12. Device Model: SAMSUNG HM641JI
  13. Serial Number: S27XJDSZ100744
  14. LU WWN Device Id: 5 0024e9 002c8553c
  15. Firmware Version: 2AJ10001
  16. User Capacity: 640 135 028 736 bytes [640 GB]
  17. Sector Sizes: 512 bytes logical, 4096 bytes physical
  18. Rotation Rate: 5400 rpm
  19. Device is: In smartctl database [for details use: -P show]
  20. ATA Version is: ATA8-ACS T13/1699-D revision 6
  21. SATA Version is: SATA 2.6, 3.0 Gb/s
  22. Local Time is: Sun Mar 29 18:58:16 2015 MSK
  23. SMART support is: Available - device has SMART capability.
  24. SMART support is: Enabled
  25.  
  26. === START OF READ SMART DATA SECTION ===
  27. SMART overall-health self-assessment test result: PASSED
  28.  
  29. General SMART Values:
  30. Offline data collection status: (0x00) Offline data collection activity
  31. was never started.
  32. Auto Offline Data Collection: Disabled.
  33. Self-test execution status: ( 121) The previous self-test completed having
  34. the read element of the test failed.
  35. Total time to complete Offline
  36. data collection: ( 9420) seconds.
  37. Offline data collection
  38. capabilities: (0x5b) SMART execute Offline immediate.
  39. Auto Offline data collection on/off support.
  40. Suspend Offline collection upon new
  41. command.
  42. Offline surface scan supported.
  43. Self-test supported.
  44. No Conveyance Self-test supported.
  45. Selective Self-test supported.
  46. SMART capabilities: (0x0003) Saves SMART data before entering
  47. power-saving mode.
  48. Supports SMART auto save timer.
  49. Error logging capability: (0x01) Error logging supported.
  50. General Purpose Logging supported.
  51. Short self-test routine
  52. recommended polling time: ( 2) minutes.
  53. Extended self-test routine
  54. recommended polling time: ( 157) minutes.
  55. SCT capabilities: (0x003f) SCT Status supported.
  56. SCT Error Recovery Control supported.
  57. SCT Feature Control supported.
  58. SCT Data Table supported.
  59.  
  60. SMART Attributes Data Structure revision number: 16
  61. Vendor Specific SMART Attributes with Thresholds:
  62. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  63. 1 Raw_Read_Error_Rate 0x002f 072 072 051 Pre-fail Always - 3430
  64. 2 Throughput_Performance 0x0026 252 252 000 Old_age Always - 0
  65. 3 Spin_Up_Time 0x0023 089 088 025 Pre-fail Always - 3554
  66. 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 491
  67. 5 Reallocated_Sector_Ct 0x0033 252 252 010 Pre-fail Always - 0
  68. 7 Seek_Error_Rate 0x002e 252 252 051 Old_age Always - 0
  69. 8 Seek_Time_Performance 0x0024 252 252 015 Old_age Offline - 0
  70. 9 Power_On_Hours 0x0032 252 252 000 Old_age Always - 0
  71. 10 Spin_Retry_Count 0x0032 252 252 051 Old_age Always - 0
  72. 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 308
  73. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 194
  74. 191 G-Sense_Error_Rate 0x0022 100 100 000 Old_age Always - 9
  75. 192 Power-Off_Retract_Count 0x0022 252 252 000 Old_age Always - 0
  76. 194 Temperature_Celsius 0x0002 064 059 000 Old_age Always - 35 (Min/Max 35/41)
  77. 195 Hardware_ECC_Recovered 0x003a 100 100 000 Old_age Always - 0
  78. 196 Reallocated_Event_Count 0x0032 252 252 000 Old_age Always - 0
  79. 197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 8
  80. 198 Offline_Uncorrectable 0x0030 252 252 000 Old_age Offline - 0
  81. 199 UDMA_CRC_Error_Count 0x0036 100 100 000 Old_age Always - 1
  82. 200 Multi_Zone_Error_Rate 0x002a 100 100 000 Old_age Always - 27
  83. 223 Load_Retry_Count 0x0032 100 100 000 Old_age Always - 308
  84. 225 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 4364
  85.  
  86. SMART Error Log Version: 1
  87. ATA Error Count: 1
  88. CR = Command Register [HEX]
  89. FR = Features Register [HEX]
  90. SC = Sector Count Register [HEX]
  91. SN = Sector Number Register [HEX]
  92. CL = Cylinder Low Register [HEX]
  93. CH = Cylinder High Register [HEX]
  94. DH = Device/Head Register [HEX]
  95. DC = Device Command Register [HEX]
  96. ER = Error register [HEX]
  97. ST = Status register [HEX]
  98. Powered_Up_Time is measured from power on, and printed as
  99. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  100. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  101.  
  102. Error 1 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
  103. When the command that caused the error occurred, the device was active or idle.
  104.  
  105. After command completion occurred, registers were:
  106. ER ST SC SN CL CH DH
  107. -- -- -- -- -- -- --
  108. 84 51 00 00 4f c2 a0 Error: ABRT
  109.  
  110. Commands leading to the command that caused the error were:
  111. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  112. -- -- -- -- -- -- -- -- ---------------- --------------------
  113. b0 d0 01 00 4f c2 a0 00 00:00:11.153 SMART READ DATA
  114. b0 d0 01 00 4f c2 a0 00 00:00:11.153 SMART READ DATA
  115. 25 00 08 40 0d 78 e0 00 00:00:11.145 READ DMA EXT
  116. 25 00 08 40 0d 78 e0 00 00:00:11.144 READ DMA EXT
  117. b0 d8 00 01 4f c2 a0 00 00:00:11.141 SMART ENABLE OPERATIONS
  118.  
  119. SMART Self-test log structure revision number 1
  120. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  121. # 1 Extended offline Completed: read failure 90% 0 17830936
  122. # 2 Extended offline Interrupted (host reset) 90% 0 -
  123.  
  124. SMART Selective self-test log data structure revision number 0
  125. Note: revision number not 1 implies that no selective self-test has ever been run
  126. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  127. 1 0 0 Completed_read_failure [90% left] (0-65535)
  128. 2 0 0 Not_testing
  129. 3 0 0 Not_testing
  130. 4 0 0 Not_testing
  131. 5 0 0 Not_testing
  132. Selective self-test flags (0x0):
  133. After scanning selected spans, do NOT read-scan remainder of disk.
  134. If Selective self-test is pending on power-up, resume after 0 minute delay.