- # /lib/nut/blazer_ser -DDDDD -a mustek
- Network UPS Tools - Megatec/Q1 protocol serial driver 1.51 (2.6.3)
- 0.000000 send_to_all: SETINFO driver.parameter.port "/dev/ttyS0"
- 0.000075 debug level is '5'
- 0.101243 send_to_all: SETINFO device.type "ups"
- 0.101288 send_to_all: SETINFO driver.version "2.6.3"
- 0.101306 send_to_all: SETINFO driver.version.internal "1.51"
- 0.101320 send_to_all: SETINFO driver.name "blazer_ser"
- 0.101331 Trying megatec protocol...
- 0.101429 send: Q1
- 0.326941 read: (226.2 226.2 225.8 049 50.0 27.5 25.0 00001001
- 0.327310 send_to_all: SETINFO input.voltage "226.2"
- 0.327335 send_to_all: SETINFO input.voltage.fault "226.2"
- 0.327354 send_to_all: SETINFO output.voltage "225.8"
- 0.327387 send_to_all: SETINFO ups.load "49"
- 0.327405 send_to_all: SETINFO input.frequency "50.0"
- 0.327423 send_to_all: SETINFO battery.voltage "27.50"
- 0.327439 send_to_all: SETINFO ups.temperature "25.0"
- 0.327453 send_to_all: SETINFO beeper.status "enabled"
- 0.327467 send_to_all: SETINFO ups.type "offline / line interactive"
- 0.327483 send_to_all: SETINFO ups.status "OL"
- 0.327495 Status read in 1 tries
- 0.327505 Supported UPS detected with megatec protocol
- 0.327696 send: F
- 0.445396 read: #220.0 007 24.00 50.0
- 0.445458 send_to_all: SETINFO input.voltage.nominal "220"
- 0.445477 send_to_all: SETINFO input.current.nominal "7.0"
- 0.445497 send_to_all: SETINFO battery.voltage.nominal "24.0"
- 0.445515 send_to_all: SETINFO input.frequency.nominal "50"
- 0.445527 Ratings read in 1 tries
- 0.445662 send: I
- 1.446715 read: timeout
- 1.446756 blazer_vendor: short reply
- 1.446769 Vendor information read 1 failed
- 1.446957 send: I
- 2.448018 read: timeout
- 2.448059 blazer_vendor: short reply
- 2.448073 Vendor information read 2 failed
- 2.448163 send: I
- 3.449214 read: timeout
- 3.449253 blazer_vendor: short reply
- 3.449267 Vendor information read 3 failed
- 3.449277 Vendor information unavailable
- 3.449290 Battery runtime will not be calculated (runtimecal not set)
- 3.449310 send_to_all: SETINFO ups.delay.start "180"
- 3.449325 send_to_all: SETINFO ups.delay.shutdown "30"
- 3.449338 send_to_all: ADDCMD beeper.toggle
- 3.449349 send_to_all: ADDCMD load.off
- 3.449361 send_to_all: ADDCMD load.on
- 3.449372 send_to_all: ADDCMD shutdown.return
- 3.449384 send_to_all: ADDCMD shutdown.stayoff
- 3.449396 send_to_all: ADDCMD shutdown.stop
- 3.449407 send_to_all: ADDCMD test.battery.start
- 3.449420 send_to_all: ADDCMD test.battery.start.deep
- 3.449432 send_to_all: ADDCMD test.battery.start.quick
- 3.449444 send_to_all: ADDCMD test.battery.stop
- 3.449533 send: Q1
- 3.674928 read: (224.3 224.8 224.3 050 50.1 27.5 25.0 00001001
- 3.674998 send_to_all: SETINFO input.voltage "224.3"
- 3.675019 send_to_all: SETINFO input.voltage.fault "224.8"
- 3.675037 send_to_all: SETINFO output.voltage "224.3"
- 3.675056 send_to_all: SETINFO ups.load "50"
- 3.675072 send_to_all: SETINFO input.frequency "50.1"
- 3.675098 send_to_all: DATAOK
- 3.675204 dstate_init: sock /var/run/nut/blazer_ser-mustek open on fd 5
- 3.675223 send_to_all: SETINFO driver.parameter.pollinterval "2"
- 3.675590 send: Q1
- 3.900776 read: (224.3 224.8 223.9 050 50.1 27.5 25.0 00001001
- 3.900838 send_to_all: SETINFO output.voltage "223.9"
- 4.491041 new connection on fd 6
- 4.491104 send_to_one: SETINFO battery.voltage "27.50"
- 4.491139 send_to_one: SETINFO battery.voltage.nominal "24.0"
- 4.491155 send_to_one: SETINFO beeper.status "enabled"
- 4.491170 send_to_one: SETINFO device.type "ups"
- 4.491207 send_to_one: SETINFO driver.name "blazer_ser"
- 4.491223 send_to_one: SETINFO driver.parameter.pollinterval "2"
- 4.491238 send_to_one: SETINFO driver.parameter.port "/dev/ttyS0"
- 4.491254 send_to_one: SETINFO driver.version "2.6.3"
- 4.491269 send_to_one: SETINFO driver.version.internal "1.51"
- 4.491284 send_to_one: SETINFO input.current.nominal "7.0"
- 4.491300 send_to_one: SETINFO input.frequency "50.1"
- 4.491314 send_to_one: SETINFO input.frequency.nominal "50"
- 4.491327 send_to_one: SETINFO input.voltage "224.3"
- 4.491342 send_to_one: SETINFO input.voltage.fault "224.8"
- 4.491357 send_to_one: SETINFO input.voltage.nominal "220"
- 4.491371 send_to_one: SETINFO output.voltage "223.9"
- 4.491388 send_to_one: SETINFO ups.delay.shutdown "30"
- 4.491403 send_to_one: SETINFO ups.delay.start "180"
- 4.491417 send_to_one: SETINFO ups.load "50"
- 4.491431 send_to_one: SETINFO ups.status "OL"
- 4.491447 send_to_one: SETINFO ups.temperature "25.0"
- 4.491461 send_to_one: SETINFO ups.type "offline / line interactive"
- 4.491475 send_to_one: ADDCMD beeper.toggle
- 4.491489 send_to_one: ADDCMD load.off
- 4.491502 send_to_one: ADDCMD load.on
- 4.491516 send_to_one: ADDCMD shutdown.return
- 4.491530 send_to_one: ADDCMD shutdown.stayoff
- 4.491543 send_to_one: ADDCMD shutdown.stop
- 4.491580 send_to_one: ADDCMD test.battery.start
- 4.491599 send_to_one: ADDCMD test.battery.start.deep
- 4.491613 send_to_one: ADDCMD test.battery.start.quick
- 4.491627 send_to_one: ADDCMD test.battery.stop
- 4.491641 send_to_one: DATAOK
- 4.491654 send_to_one: DUMPDONE
- 5.676542 send: Q1
- 5.902067 read: (224.3 224.3 223.9 050 50.1 27.5 25.0 00001001
- 5.902126 send_to_all: SETINFO input.voltage.fault "224.3"
- 7.678352 send: Q1
- 7.903790 read: (224.3 224.8 223.9 050 50.1 27.5 25.0 00001001
- 7.903849 send_to_all: SETINFO input.voltage.fault "224.8"
- 9.680159 send: Q1
- 9.905486 read: (224.8 224.3 223.9 050 50.1 27.5 25.0 00001001
- 9.905543 send_to_all: SETINFO input.voltage "224.8"
- 9.905580 send_to_all: SETINFO input.voltage.fault "224.3"
- 11.682340 send: Q1
- 11.907637 read: (224.3 224.8 225.5 050 50.1 27.5 25.0 00001001
- 11.907704 send_to_all: SETINFO input.voltage "224.3"
- 11.907738 send_to_all: SETINFO input.voltage.fault "224.8"
- 11.907763 send_to_all: SETINFO output.voltage "225.5"
- 13.684076 send: Q1
- 13.909748 read: (224.3 224.3 225.5 050 50.1 27.5 25.0 00001001
- 13.909807 send_to_all: SETINFO input.voltage.fault "224.3"
- 15.686321 send: Q1
- 15.911511 read: (224.3 224.8 223.9 050 50.1 27.5 25.0 00001001
- 15.911605 send_to_all: SETINFO input.voltage.fault "224.8"
- 15.911634 send_to_all: SETINFO output.voltage "223.9"
- 17.687697 send: Q1
- 17.913180 read: (224.3 224.8 224.7 050 50.1 27.5 25.0 00001001
- 17.913243 send_to_all: SETINFO output.voltage "224.7"
- 19.689505 send: Q1
- 19.914887 read: (224.8 224.8 223.9 050 50.1 27.5 25.0 00001001
- 19.914942 send_to_all: SETINFO input.voltage "224.8"
- 19.914982 send_to_all: SETINFO output.voltage "223.9"
- 21.691335 send: Q1
- 21.916592 read: (224.8 224.3 224.7 050 50.1 27.5 25.0 00001001
- 21.916653 send_to_all: SETINFO input.voltage.fault "224.3"
- 21.916688 send_to_all: SETINFO output.voltage "224.7"
- 23.693138 send: Q1
- 23.918738 read: (224.8 224.3 225.5 050 50.1 27.5 25.0 00001001
- 23.918808 send_to_all: SETINFO output.voltage "225.5"
- 25.694934 send: Q1
- 25.920445 read: (225.2 224.8 225.5 049 50.1 27.5 25.0 00001001
- 25.920851 send_to_all: SETINFO input.voltage "225.2"
- 25.920893 send_to_all: SETINFO input.voltage.fault "224.8"
- 25.920929 send_to_all: SETINFO ups.load "49"
- 27.696595 send: Q1
- 27.921725 read: (224.8 224.8 223.9 050 50.1 27.5 25.0 00001001
- 27.921780 send_to_all: SETINFO input.voltage "224.8"
- 27.921815 send_to_all: SETINFO output.voltage "223.9"
- 27.921840 send_to_all: SETINFO ups.load "50"