- smartctl 5.40 2010-07-12 r3124 [i686-pc-linux-gnu] (local build)
- Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
- === START OF INFORMATION SECTION ===
- Device Model: Hitachi HTS723232L9A362
- Serial Number: 081216FC3400NEGK2MDD
- Firmware Version: FC4OC30F
- User Capacity: 320,072,933,376 bytes
- Device is: Not in smartctl database [for details use: -P showall]
- ATA Version is: 8
- ATA Standard is: ATA-8-ACS revision 3f
- Local Time is: Fri Aug 26 15:07:44 2011 CEST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 645) seconds.
- Offline data collection
- capabilities: (0x5b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- No Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 96) minutes.
- SCT capabilities: (0x003d) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000b 086 086 062 Pre-fail Always - 115
- 2 Throughput_Performance 0x0004 100 100 000 Old_age Offline - 0
- 3 Spin_Up_Time 0x0007 173 173 033 Pre-fail Always - 2
- 4 Start_Stop_Count 0x0012 089 089 000 Old_age Always - 17940
- 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x000a 100 100 000 Old_age Always - 0
- 8 Seek_Time_Performance 0x0004 100 100 000 Old_age Offline - 0
- 9 Power_On_Hours 0x0012 075 075 000 Old_age Always - 11262
- 10 Spin_Retry_Count 0x0012 100 100 000 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 098 098 000 Old_age Always - 3279
- 160 Unknown_Attribute 0x003a 100 100 000 Old_age Always - 0
- 191 G-Sense_Error_Rate 0x000a 100 100 000 Old_age Always - 0
- 192 Power-Off_Retract_Count 0x0032 021 021 000 Old_age Always - 68021877932086
- 193 Load_Cycle_Count 0x0012 089 089 000 Old_age Always - 114997
- 194 Temperature_Celsius 0x0002 122 122 000 Old_age Always - 45 (Lifetime Min/Max 14/55)
- 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 11
- 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 6
- 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0
- 223 Load_Retry_Count 0x000a 100 100 000 Old_age Always - 0
- 240 Head_Flying_Hours 0x0032 076 076 000 Old_age Always - 10774
- 241 Total_LBAs_Written 0x0032 100 100 000 Old_age Always - 13687905856
- 242 Total_LBAs_Read 0x0032 100 100 000 Old_age Always - 12553061518
- 254 Free_Fall_Sensor 0x0032 039 039 000 Old_age Always - 15837
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Interrupted (host reset) 50% 7138 -
- # 2 Short offline Completed without error 00% 5367 -
- # 3 Short offline Completed without error 00% 1 -
- # 4 Short offline Completed without error 00% 0 -
- # 5 Short offline Completed without error 00% 0 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.