- === START OF INFORMATION SECTION ===
- Model Family: Hitachi/HGST Travelstar Z5K500
- Device Model: HGST HTS545050A7E680
- Serial Number: RBF52AM525969P
- LU WWN Device Id: 5 000cca 7a3de9769
- Firmware Version: GR2OA230
- User Capacity: 500,107,862,016 bytes [500 GB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 5400 rpm
- Form Factor: 2.5 inches
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ATA8-ACS T13/1699-D revision 6
- SATA Version is: SATA 2.6, 6.0 Gb/s (current: 1.5 Gb/s)
- Local Time is: Sun Mar 5 22:29:58 2017 EET
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 45) seconds.
- Offline data collection
- capabilities: (0x5b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- No Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 112) minutes.
- SCT capabilities: (0x003d) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000b 099 099 062 Pre-fail Always - 196608
- 2 Throughput_Performance 0x0005 100 100 040 Pre-fail Offline - 0
- 3 Spin_Up_Time 0x0007 208 208 033 Pre-fail Always - 1
- 4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 779
- 5 Reallocated_Sector_Ct 0x0033 083 083 005 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0
- 8 Seek_Time_Performance 0x0005 100 100 040 Pre-fail Offline - 0
- 9 Power_On_Hours 0x0012 096 096 000 Old_age Always - 2097
- 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 775
- 191 G-Sense_Error_Rate 0x000a 100 100 000 Old_age Always - 0
- 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 160
- 193 Load_Cycle_Count 0x0012 098 098 000 Old_age Always - 26180
- 194 Temperature_Celsius 0x0002 222 222 000 Old_age Always - 27 (Min/Max 5/58)
- 196 Reallocated_Event_Count 0x0032 087 087 000 Old_age Always - 505
- 197 Current_Pending_Sector 0x0022 077 077 000 Old_age Always - 744
- 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0
- 223 Load_Retry_Count 0x000a 100 100 000 Old_age Always - 0
- SMART Error Log Version: 1
- ATA Error Count: 2618 (device log contains only the most recent five errors)
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 2618 occurred at disk power-on lifetime: 2096 hours (87 days + 8 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 35 a8 70 af 02 Error: UNC at LBA = 0x02af70a8 = 45052072
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 42 00 ff de 6f af e0 00 02:08:44.592 READ VERIFY SECTOR(S) EXT
- 42 00 ff df 6e af e0 00 02:08:44.591 READ VERIFY SECTOR(S) EXT
- 42 00 ff e0 6d af e0 00 02:08:44.590 READ VERIFY SECTOR(S) EXT
- 42 00 ff e1 6c af e0 00 02:08:44.589 READ VERIFY SECTOR(S) EXT
- 42 00 ff e2 6b af e0 00 02:08:44.588 READ VERIFY SECTOR(S) EXT
- Error 2617 occurred at disk power-on lifetime: 2096 hours (87 days + 8 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 fd e8 67 af 02 Error: UNC at LBA = 0x02af67e8 = 45049832
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 42 00 ff e6 67 af e0 00 02:08:41.059 READ VERIFY SECTOR(S) EXT
- 42 00 ff e7 66 af e0 00 02:08:41.058 READ VERIFY SECTOR(S) EXT
- 42 00 ff e8 65 af e0 00 02:08:41.057 READ VERIFY SECTOR(S) EXT
- 42 00 ff e9 64 af e0 00 02:08:41.056 READ VERIFY SECTOR(S) EXT
- 42 00 ff ea 63 af e0 00 02:08:41.033 READ VERIFY SECTOR(S) EXT
- Error 2616 occurred at disk power-on lifetime: 2096 hours (87 days + 8 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 c6 28 5f af 02 Error: UNC at LBA = 0x02af5f28 = 45047592
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 42 00 ff ef 5e af e0 00 02:08:37.492 READ VERIFY SECTOR(S) EXT
- 42 00 ff f0 5d af e0 00 02:08:37.491 READ VERIFY SECTOR(S) EXT
- 42 00 ff f1 5c af e0 00 02:08:37.490 READ VERIFY SECTOR(S) EXT
- 42 00 ff f2 5b af e0 00 02:08:37.489 READ VERIFY SECTOR(S) EXT
- 42 00 ff f3 5a af e0 00 02:08:37.488 READ VERIFY SECTOR(S) EXT
- Error 2615 occurred at disk power-on lifetime: 2096 hours (87 days + 8 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 a9 00 25 2f 02 Error: UNC at LBA = 0x022f2500 = 36644096
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 42 00 ff aa 24 2f e0 00 02:06:54.060 READ VERIFY SECTOR(S) EXT
- 42 00 ff ab 23 2f e0 00 02:06:54.036 READ VERIFY SECTOR(S) EXT
- 42 00 ff ac 22 2f e0 00 02:06:54.034 READ VERIFY SECTOR(S) EXT
- 42 00 ff ad 21 2f e0 00 02:06:54.033 READ VERIFY SECTOR(S) EXT
- 42 00 ff ae 20 2f e0 00 02:06:54.032 READ VERIFY SECTOR(S) EXT
- Error 2614 occurred at disk power-on lifetime: 2096 hours (87 days + 8 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 72 40 1c 2f 02 Error: UNC at LBA = 0x022f1c40 = 36641856
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 42 00 ff b3 1b 2f e0 00 02:06:50.405 READ VERIFY SECTOR(S) EXT
- 42 00 ff b4 1a 2f e0 00 02:06:50.404 READ VERIFY SECTOR(S) EXT
- 42 00 ff b5 19 2f e0 00 02:06:50.402 READ VERIFY SECTOR(S) EXT
- 42 00 ff b6 18 2f e0 00 02:06:50.378 READ VERIFY SECTOR(S) EXT
- 42 00 ff b7 17 2f e0 00 02:06:50.376 READ VERIFY SECTOR(S) EXT
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed without error 00% 2094 -
- # 2 Short offline Aborted by host 90% 2093 -
- # 3 Short offline Aborted by host 90% 2093 -
- # 4 Short offline Completed: read failure 30% 2087 35341728
- # 5 Short offline Completed: read failure 30% 2086 34795792
- # 6 Short offline Completed without error 00% 2083 -
- # 7 Short offline Completed without error 00% 2083 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.