- Tap---01-+--Pump A-+-05---------HERMS--------06-+--Temp Sensor--+-09---Drain
- | | | |
- Kettle---02-+ +-07----Filter--Chiller---08-+ +-10---HLT
- | |
- HLT---03-+ +-11---Tun
- | |
- Tun-+-04-+ +-12---Fermenter
- | |
- | +-13-+-Kettle
- | |
- +-14--Pump B--------------------------------------------------15-+
- Two-digit numbers (nn) represent ball valves
- The HLT heating element is controlled by the temperature sensor. The kettle
- heating element is uncontrolled - just used to boil.