  1. smartctl 5.40 2010-10-16 r3189 [i686-pc-linux-gnu] (local build)
  2. Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Device Model: INTEL SSDSA2CW120G3
  6. Serial Number: CVPR117202AM120LGN
  7. Firmware Version: 4PC10302
  8. User Capacity: 120 034 123 776 bytes
  9. Device is: Not in smartctl database [for details use: -P showall]
  10. ATA Version is: 8
  11. ATA Standard is: ATA-8-ACS revision 4
  12. Local Time is: Thu Jun 23 00:57:58 2011 CEST
  13. SMART support is: Available - device has SMART capability.
  14. SMART support is: Enabled
  15.  
  16. === START OF READ SMART DATA SECTION ===
  17. SMART overall-health self-assessment test result: PASSED
  18.  
  19. General SMART Values:
  20. Offline data collection status: (0x00) Offline data collection activity
  21. was never started.
  22. Auto Offline Data Collection: Disabled.
  23. Self-test execution status: ( 249) Self-test routine in progress...
  24. 90% of test remaining.
  25. Total time to complete Offline
  26. data collection: ( 1) seconds.
  27. Offline data collection
  28. capabilities: (0x71) SMART execute Offline immediate.
  29. No Auto Offline data collection support.
  30. Suspend Offline collection upon new
  31. command.
  32. No Offline surface scan supported.
  33. Self-test supported.
  34. Conveyance Self-test supported.
  35. Selective Self-test supported.
  36. SMART capabilities: (0x0003) Saves SMART data before entering
  37. power-saving mode.
  38. Supports SMART auto save timer.
  39. Error logging capability: (0x01) Error logging supported.
  40. General Purpose Logging supported.
  41. Short self-test routine
  42. recommended polling time: ( 1) minutes.
  43. Extended self-test routine
  44. recommended polling time: ( 1) minutes.
  45. Conveyance self-test routine
  46. recommended polling time: ( 1) minutes.
  47. SCT capabilities: (0x003d) SCT Status supported.
  48. SCT Error Recovery Control supported.
  49. SCT Feature Control supported.
  50. SCT Data Table supported.
  51.  
  52. SMART Attributes Data Structure revision number: 5
  53. Vendor Specific SMART Attributes with Thresholds:
  54. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  55. 3 Spin_Up_Time 0x0020 100 100 000 Old_age Offline - 0
  56. 4 Start_Stop_Count 0x0030 100 100 000 Old_age Offline - 0
  57. 5 Reallocated_Sector_Ct 0x0032 100 100 000 Old_age Always - 0
  58. 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 61
  59. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 16
  60. 170 Unknown_Attribute 0x0033 100 100 010 Pre-fail Always - 0
  61. 171 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0
  62. 172 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0
  63. 184 End-to-End_Error 0x0033 100 100 090 Pre-fail Always - 0
  64. 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
  65. 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 11
  66. 225 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 7246
  67. 226 Load-in_Time 0x0032 100 100 000 Old_age Always - 51
  68. 227 Torq-amp_Count 0x0032 100 100 000 Old_age Always - 0
  69. 228 Power-off_Retract_Count 0x0032 100 100 000 Old_age Always - 2147489358
  70. 232 Available_Reservd_Space 0x0033 100 100 010 Pre-fail Always - 0
  71. 233 Media_Wearout_Indicator 0x0032 100 100 000 Old_age Always - 0
  72. 241 Total_LBAs_Written 0x0032 100 100 000 Old_age Always - 7246
  73. 242 Total_LBAs_Read 0x0032 100 100 000 Old_age Always - 6621
  74.  
  75. SMART Error Log Version: 1
  76. No Errors Logged
  77.  
  78. SMART Self-test log structure revision number 1
  79. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  80. # 1 Vendor (0x78) Completed without error 150% 61 -
  81. # 2 Vendor (0xf8) Completed without error 00% 61 -
  82. # 3 Vendor (0x44) Completed without error 10% 60 -
  83.  
  84. Note: selective self-test log revision number (0) not 1 implies that no selective self-test has ever been run
  85. SMART Selective self-test log data structure revision number 0
  86. Note: revision number not 1 implies that no selective self-test has ever been run
  87. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  88. 1 0 0 Not_testing
  89. 2 0 0 Not_testing
  90. 3 0 0 Not_testing
  91. 4 0 0 Not_testing
  92. 5 0 0 Not_testing
  93. Selective self-test flags (0x0):
  94. After scanning selected spans, do NOT read-scan remainder of disk.
  95. If Selective self-test is pending on power-up, resume after 0 minute delay.