- smartctl 5.40 2010-07-12 r3124 [i686-pc-linux-gnu] (local build)
- Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
- === START OF INFORMATION SECTION ===
- Model Family: Seagate Barracuda 7200.12 family
- Device Model: ST31000528AS
- Serial Number: 5VP4TT5D
- Firmware Version: CC38
- User Capacity: 1,000,204,886,016 bytes
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: 8
- ATA Standard is: ATA-8-ACS revision 4
- Local Time is: Mon Mar 5 18:12:54 2012 UTC
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x82) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 600) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: ( 175) minutes.
- Conveyance self-test routine
- recommended polling time: ( 2) minutes.
- SCT capabilities: (0x103f) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 10
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 097 095 006 Pre-fail Always - 30683017
- 3 Spin_Up_Time 0x0003 095 095 000 Pre-fail Always - 0
- 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 18
- 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x000f 087 060 030 Pre-fail Always - 4893597743
- 9 Power_On_Hours 0x0032 086 086 000 Old_age Always - 12920
- 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 9
- 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0
- 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
- 187 Reported_Uncorrect 0x0032 028 028 000 Old_age Always - 72
- 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 2
- 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
- 190 Airflow_Temperature_Cel 0x0022 075 053 045 Old_age Always - 25 (Lifetime Min/Max 23/26)
- 194 Temperature_Celsius 0x0022 025 047 000 Old_age Always - 25 (0 18 0 0)
- 195 Hardware_ECC_Recovered 0x001a 038 008 000 Old_age Always - 30683017
- 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 1
- 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 1
- 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
- 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 271983098999437
- 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 2296879801
- 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 2063874948
- SMART Error Log Version: 1
- ATA Error Count: 72 (device log contains only the most recent five errors)
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 72 occurred at disk power-on lifetime: 12920 hours (538 days + 8 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 34 f8 ac 00
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 00 08 30 f8 ac 40 00 05:19:00.482 READ FPDMA QUEUED
- 27 00 00 00 00 00 e0 00 05:19:00.481 READ NATIVE MAX ADDRESS EXT
- ec 00 00 00 00 00 a0 00 05:19:00.481 IDENTIFY DEVICE
- ef 03 46 00 00 00 a0 00 05:19:00.480 SET FEATURES [Set transfer mode]
- 27 00 00 00 00 00 e0 00 05:19:00.480 READ NATIVE MAX ADDRESS EXT
- Error 71 occurred at disk power-on lifetime: 12920 hours (538 days + 8 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 34 f8 ac 00
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 00 08 30 f8 ac 40 00 05:18:57.318 READ FPDMA QUEUED
- 27 00 00 00 00 00 e0 00 05:18:57.318 READ NATIVE MAX ADDRESS EXT
- ec 00 00 00 00 00 a0 00 05:18:57.317 IDENTIFY DEVICE
- ef 03 46 00 00 00 a0 00 05:18:57.317 SET FEATURES [Set transfer mode]
- 27 00 00 00 00 00 e0 00 05:18:57.316 READ NATIVE MAX ADDRESS EXT
- Error 70 occurred at disk power-on lifetime: 12920 hours (538 days + 8 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 34 f8 ac 00
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 00 08 30 f8 ac 40 00 05:18:54.154 READ FPDMA QUEUED
- 27 00 00 00 00 00 e0 00 05:18:54.154 READ NATIVE MAX ADDRESS EXT
- ec 00 00 00 00 00 a0 00 05:18:54.153 IDENTIFY DEVICE
- ef 03 46 00 00 00 a0 00 05:18:54.153 SET FEATURES [Set transfer mode]
- 27 00 00 00 00 00 e0 00 05:18:54.153 READ NATIVE MAX ADDRESS EXT
- Error 69 occurred at disk power-on lifetime: 12920 hours (538 days + 8 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 34 f8 ac 00
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 00 08 30 f8 ac 40 00 05:18:50.974 READ FPDMA QUEUED
- 27 00 00 00 00 00 e0 00 05:18:50.974 READ NATIVE MAX ADDRESS EXT
- ec 00 00 00 00 00 a0 00 05:18:50.973 IDENTIFY DEVICE
- ef 03 46 00 00 00 a0 00 05:18:50.973 SET FEATURES [Set transfer mode]
- 27 00 00 00 00 00 e0 00 05:18:50.972 READ NATIVE MAX ADDRESS EXT
- Error 68 occurred at disk power-on lifetime: 12920 hours (538 days + 8 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 34 f8 ac 00
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 00 08 30 f8 ac 40 00 05:18:47.802 READ FPDMA QUEUED
- 27 00 00 00 00 00 e0 00 05:18:47.802 READ NATIVE MAX ADDRESS EXT
- ec 00 00 00 00 00 a0 00 05:18:47.801 IDENTIFY DEVICE
- ef 03 46 00 00 00 a0 00 05:18:47.800 SET FEATURES [Set transfer mode]
- 27 00 00 00 00 00 e0 00 05:18:47.800 READ NATIVE MAX ADDRESS EXT
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed without error 00% 6 -
- # 2 Short offline Completed without error 00% 2 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.