Advertisement
Guest User

SMARTCTL REPORT

a guest
Aug 16th, 2012
255
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 11.73 KB | None | 0 0
  1. smartctl 5.43 2012-06-30 r3573 [x86_64-linux-3.4.8-1-ARCH] (local build)
  2. Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family: Toshiba 2.5" HDD MK..55GSX
  6. Device Model: TOSHIBA MK2555GSX
  7. Serial Number: 49U4FA9BS
  8. LU WWN Device Id: 5 000039 1b6909dae
  9. Firmware Version: FG002C
  10. User Capacity: 250,059,350,016 bytes [250 GB]
  11. Sector Size: 512 bytes logical/physical
  12. Device is: In smartctl database [for details use: -P show]
  13. ATA Version is: 8
  14. ATA Standard is: Exact ATA specification draft version not indicated
  15. Local Time is: Thu Aug 16 10:50:26 2012 EDT
  16. SMART support is: Available - device has SMART capability.
  17. SMART support is: Enabled
  18.  
  19. === START OF READ SMART DATA SECTION ===
  20. SMART overall-health self-assessment test result: PASSED
  21. See vendor-specific Attribute list for marginal Attributes.
  22.  
  23. General SMART Values:
  24. Offline data collection status: (0x02) Offline data collection activity
  25. was completed without error.
  26. Auto Offline Data Collection: Disabled.
  27. Self-test execution status: ( 121) The previous self-test completed having
  28. the read element of the test failed.
  29. Total time to complete Offline
  30. data collection: ( 120) seconds.
  31. Offline data collection
  32. capabilities: (0x51) SMART execute Offline immediate.
  33. No Auto Offline data collection support.
  34. Suspend Offline collection upon new
  35. command.
  36. No Offline surface scan supported.
  37. Self-test supported.
  38. No Conveyance Self-test supported.
  39. Selective Self-test supported.
  40. SMART capabilities: (0x0003) Saves SMART data before entering
  41. power-saving mode.
  42. Supports SMART auto save timer.
  43. Error logging capability: (0x01) Error logging supported.
  44. General Purpose Logging supported.
  45. Short self-test routine
  46. recommended polling time: ( 2) minutes.
  47. Extended self-test routine
  48. recommended polling time: ( 79) minutes.
  49. SCT capabilities: (0x0033) SCT Status supported.
  50. SCT Feature Control supported.
  51. SCT Data Table supported.
  52.  
  53. SMART Attributes Data Structure revision number: 16
  54. Vendor Specific SMART Attributes with Thresholds:
  55. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  56. 1 Raw_Read_Error_Rate 0x000f 100 100 050 Pre-fail Always - 0
  57. 2 Throughput_Performance 0x0007 100 100 050 Pre-fail Always - 0
  58. 3 Spin_Up_Time 0x0003 100 100 002 Pre-fail Always - 567
  59. 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 2649
  60. 5 Reallocated_Sector_Ct 0x0033 099 099 010 Pre-fail Always - 30
  61. 7 Seek_Error_Rate 0x000f 100 100 050 Pre-fail Always - 0
  62. 8 Seek_Time_Performance 0x0005 100 100 050 Pre-fail Offline - 0
  63. 9 Power_On_Hours 0x0032 056 056 000 Old_age Always - 17953
  64. 10 Spin_Retry_Count 0x0013 152 100 030 Pre-fail Always - 0
  65. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 2503
  66. 183 Runtime_Bad_Block 0x0022 100 100 001 Old_age Always - 1
  67. 184 End-to-End_Error 0x0033 100 100 097 Pre-fail Always - 0
  68. 185 Unknown_Attribute 0x0032 100 100 001 Old_age Always - 65535
  69. 187 Reported_Uncorrect 0x0032 001 001 000 Old_age Always - 2300
  70. 188 Command_Timeout 0x0032 100 098 000 Old_age Always - 29
  71. 189 High_Fly_Writes 0x003a 100 100 001 Old_age Always - 0
  72. 190 Airflow_Temperature_Cel 0x0022 058 032 045 Old_age Always In_the_past 42 (Min/Max 40/45)
  73. 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 716
  74. 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 17236231
  75. 193 Load_Cycle_Count 0x0032 081 081 000 Old_age Always - 198194
  76. 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 12
  77. 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 2
  78. 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
  79.  
  80. SMART Error Log Version: 1
  81. ATA Error Count: 2978 (device log contains only the most recent five errors)
  82. CR = Command Register [HEX]
  83. FR = Features Register [HEX]
  84. SC = Sector Count Register [HEX]
  85. SN = Sector Number Register [HEX]
  86. CL = Cylinder Low Register [HEX]
  87. CH = Cylinder High Register [HEX]
  88. DH = Device/Head Register [HEX]
  89. DC = Device Command Register [HEX]
  90. ER = Error register [HEX]
  91. ST = Status register [HEX]
  92. Powered_Up_Time is measured from power on, and printed as
  93. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  94. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  95.  
  96. Error 2978 occurred at disk power-on lifetime: 17926 hours (746 days + 22 hours)
  97. When the command that caused the error occurred, the device was active or idle.
  98.  
  99. After command completion occurred, registers were:
  100. ER ST SC SN CL CH DH
  101. -- -- -- -- -- -- --
  102. 40 41 02 3c f5 4e 60 Error: UNC at LBA = 0x004ef53c = 5174588
  103.  
  104. Commands leading to the command that caused the error were:
  105. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  106. -- -- -- -- -- -- -- -- ---------------- --------------------
  107. 60 08 00 38 f5 4e 40 08 01:44:58.612 READ FPDMA QUEUED
  108. ef 10 02 00 00 00 a0 00 01:44:58.612 SET FEATURES [Reserved for Serial ATA]
  109. ec 00 00 00 00 00 a0 00 01:44:58.611 IDENTIFY DEVICE
  110. ef 03 45 00 00 00 a0 00 01:44:58.611 SET FEATURES [Set transfer mode]
  111. ef 10 02 00 00 00 a0 00 01:44:58.611 SET FEATURES [Reserved for Serial ATA]
  112.  
  113. Error 2977 occurred at disk power-on lifetime: 17926 hours (746 days + 22 hours)
  114. When the command that caused the error occurred, the device was active or idle.
  115.  
  116. After command completion occurred, registers were:
  117. ER ST SC SN CL CH DH
  118. -- -- -- -- -- -- --
  119. 40 41 02 3c f5 4e 60 Error: UNC at LBA = 0x004ef53c = 5174588
  120.  
  121. Commands leading to the command that caused the error were:
  122. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  123. -- -- -- -- -- -- -- -- ---------------- --------------------
  124. 60 08 00 38 f5 4e 40 08 01:44:54.778 READ FPDMA QUEUED
  125. ef 10 02 00 00 00 a0 00 01:44:54.778 SET FEATURES [Reserved for Serial ATA]
  126. ec 00 00 00 00 00 a0 00 01:44:54.778 IDENTIFY DEVICE
  127. ef 03 45 00 00 00 a0 00 01:44:54.778 SET FEATURES [Set transfer mode]
  128. ef 10 02 00 00 00 a0 00 01:44:54.778 SET FEATURES [Reserved for Serial ATA]
  129.  
  130. Error 2976 occurred at disk power-on lifetime: 17926 hours (746 days + 22 hours)
  131. When the command that caused the error occurred, the device was active or idle.
  132.  
  133. After command completion occurred, registers were:
  134. ER ST SC SN CL CH DH
  135. -- -- -- -- -- -- --
  136. 40 41 02 3c f5 4e 60 Error: UNC at LBA = 0x004ef53c = 5174588
  137.  
  138. Commands leading to the command that caused the error were:
  139. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  140. -- -- -- -- -- -- -- -- ---------------- --------------------
  141. 60 08 00 38 f5 4e 40 08 01:44:50.945 READ FPDMA QUEUED
  142. ef 10 02 00 00 00 a0 00 01:44:50.945 SET FEATURES [Reserved for Serial ATA]
  143. ec 00 00 00 00 00 a0 00 01:44:50.944 IDENTIFY DEVICE
  144. ef 03 45 00 00 00 a0 00 01:44:50.944 SET FEATURES [Set transfer mode]
  145. ef 10 02 00 00 00 a0 00 01:44:50.944 SET FEATURES [Reserved for Serial ATA]
  146.  
  147. Error 2975 occurred at disk power-on lifetime: 17926 hours (746 days + 22 hours)
  148. When the command that caused the error occurred, the device was active or idle.
  149.  
  150. After command completion occurred, registers were:
  151. ER ST SC SN CL CH DH
  152. -- -- -- -- -- -- --
  153. 40 41 02 3c f5 4e 60 Error: UNC at LBA = 0x004ef53c = 5174588
  154.  
  155. Commands leading to the command that caused the error were:
  156. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  157. -- -- -- -- -- -- -- -- ---------------- --------------------
  158. 60 08 00 38 f5 4e 40 08 01:44:47.111 READ FPDMA QUEUED
  159. ef 10 02 00 00 00 a0 00 01:44:47.111 SET FEATURES [Reserved for Serial ATA]
  160. ec 00 00 00 00 00 a0 00 01:44:47.111 IDENTIFY DEVICE
  161. ef 03 45 00 00 00 a0 00 01:44:47.111 SET FEATURES [Set transfer mode]
  162. ef 10 02 00 00 00 a0 00 01:44:47.110 SET FEATURES [Reserved for Serial ATA]
  163.  
  164. Error 2974 occurred at disk power-on lifetime: 17926 hours (746 days + 22 hours)
  165. When the command that caused the error occurred, the device was active or idle.
  166.  
  167. After command completion occurred, registers were:
  168. ER ST SC SN CL CH DH
  169. -- -- -- -- -- -- --
  170. 40 41 02 3c f5 4e 60 Error: UNC at LBA = 0x004ef53c = 5174588
  171.  
  172. Commands leading to the command that caused the error were:
  173. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  174. -- -- -- -- -- -- -- -- ---------------- --------------------
  175. 60 08 00 38 f5 4e 40 08 01:44:43.278 READ FPDMA QUEUED
  176. ef 10 02 00 00 00 a0 00 01:44:43.278 SET FEATURES [Reserved for Serial ATA]
  177. ec 00 00 00 00 00 a0 00 01:44:43.277 IDENTIFY DEVICE
  178. ef 03 45 00 00 00 a0 00 01:44:43.277 SET FEATURES [Set transfer mode]
  179. ef 10 02 00 00 00 a0 00 01:44:43.277 SET FEATURES [Reserved for Serial ATA]
  180.  
  181. SMART Self-test log structure revision number 1
  182. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  183. # 1 Short offline Completed: read failure 90% 17931 5174588
  184. # 2 Short offline Completed: read failure 90% 17911 5174588
  185. # 3 Short offline Completed: read failure 90% 17911 5174588
  186. # 4 Short offline Completed: read failure 90% 16656 193930251
  187. # 5 Short offline Completed: read failure 90% 16633 193930251
  188. # 6 Short offline Completed: read failure 90% 16633 193930251
  189. # 7 Short offline Completed: read failure 90% 16632 193930251
  190. # 8 Short offline Completed: read failure 90% 16632 193930251
  191. # 9 Short offline Completed: read failure 80% 16632 193930251
  192. #10 Extended offline Completed: read failure 00% 16628 0
  193. #11 Extended offline Completed without error 00% 16164 -
  194. #12 Short offline Completed without error 00% 15064 -
  195. #13 Extended offline Completed without error 00% 14042 -
  196. #14 Short offline Completed without error 00% 14040 -
  197. #15 Short offline Completed without error 00% 13605 -
  198. #16 Extended offline Interrupted (host reset) 10% 13569 -
  199. #17 Short offline Completed without error 00% 13550 -
  200. #18 Short offline Completed without error 00% 13189 -
  201. #19 Extended offline Aborted by host 10% 13189 -
  202. #20 Short offline Aborted by host 90% 13100 -
  203. #21 Extended offline Aborted by host 10% 13100 -
  204.  
  205. SMART Selective self-test log data structure revision number 1
  206. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  207. 1 0 0 Not_testing
  208. 2 0 0 Not_testing
  209. 3 0 0 Not_testing
  210. 4 0 0 Not_testing
  211. 5 0 0 Not_testing
  212. Selective self-test flags (0x0):
  213. After scanning selected spans, do NOT read-scan remainder of disk.
  214. If Selective self-test is pending on power-up, resume after 0 minute delay.
Advertisement
Add Comment
Please, Sign In to add comment
Advertisement