- smartctl 5.43 2012-06-30 r3573 [x86_64-linux-3.4.8-1-ARCH] (local build)
- Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net
- === START OF INFORMATION SECTION ===
- Model Family: Toshiba 2.5" HDD MK..55GSX
- Device Model: TOSHIBA MK2555GSX
- Serial Number: 49U4FA9BS
- LU WWN Device Id: 5 000039 1b6909dae
- Firmware Version: FG002C
- User Capacity: 250,059,350,016 bytes [250 GB]
- Sector Size: 512 bytes logical/physical
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: 8
- ATA Standard is: Exact ATA specification draft version not indicated
- Local Time is: Thu Aug 16 10:50:26 2012 EDT
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- See vendor-specific Attribute list for marginal Attributes.
- General SMART Values:
- Offline data collection status: (0x02) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 121) The previous self-test completed having
- the read element of the test failed.
- Total time to complete Offline
- data collection: ( 120) seconds.
- Offline data collection
- capabilities: (0x51) SMART execute Offline immediate.
- No Auto Offline data collection support.
- Suspend Offline collection upon new
- command.
- No Offline surface scan supported.
- Self-test supported.
- No Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 79) minutes.
- SCT capabilities: (0x0033) SCT Status supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 100 100 050 Pre-fail Always - 0
- 2 Throughput_Performance 0x0007 100 100 050 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0003 100 100 002 Pre-fail Always - 567
- 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 2649
- 5 Reallocated_Sector_Ct 0x0033 099 099 010 Pre-fail Always - 30
- 7 Seek_Error_Rate 0x000f 100 100 050 Pre-fail Always - 0
- 8 Seek_Time_Performance 0x0005 100 100 050 Pre-fail Offline - 0
- 9 Power_On_Hours 0x0032 056 056 000 Old_age Always - 17953
- 10 Spin_Retry_Count 0x0013 152 100 030 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 2503
- 183 Runtime_Bad_Block 0x0022 100 100 001 Old_age Always - 1
- 184 End-to-End_Error 0x0033 100 100 097 Pre-fail Always - 0
- 185 Unknown_Attribute 0x0032 100 100 001 Old_age Always - 65535
- 187 Reported_Uncorrect 0x0032 001 001 000 Old_age Always - 2300
- 188 Command_Timeout 0x0032 100 098 000 Old_age Always - 29
- 189 High_Fly_Writes 0x003a 100 100 001 Old_age Always - 0
- 190 Airflow_Temperature_Cel 0x0022 058 032 045 Old_age Always In_the_past 42 (Min/Max 40/45)
- 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 716
- 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 17236231
- 193 Load_Cycle_Count 0x0032 081 081 000 Old_age Always - 198194
- 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 12
- 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 2
- 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
- SMART Error Log Version: 1
- ATA Error Count: 2978 (device log contains only the most recent five errors)
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 2978 occurred at disk power-on lifetime: 17926 hours (746 days + 22 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 41 02 3c f5 4e 60 Error: UNC at LBA = 0x004ef53c = 5174588
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 08 00 38 f5 4e 40 08 01:44:58.612 READ FPDMA QUEUED
- ef 10 02 00 00 00 a0 00 01:44:58.612 SET FEATURES [Reserved for Serial ATA]
- ec 00 00 00 00 00 a0 00 01:44:58.611 IDENTIFY DEVICE
- ef 03 45 00 00 00 a0 00 01:44:58.611 SET FEATURES [Set transfer mode]
- ef 10 02 00 00 00 a0 00 01:44:58.611 SET FEATURES [Reserved for Serial ATA]
- Error 2977 occurred at disk power-on lifetime: 17926 hours (746 days + 22 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 41 02 3c f5 4e 60 Error: UNC at LBA = 0x004ef53c = 5174588
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 08 00 38 f5 4e 40 08 01:44:54.778 READ FPDMA QUEUED
- ef 10 02 00 00 00 a0 00 01:44:54.778 SET FEATURES [Reserved for Serial ATA]
- ec 00 00 00 00 00 a0 00 01:44:54.778 IDENTIFY DEVICE
- ef 03 45 00 00 00 a0 00 01:44:54.778 SET FEATURES [Set transfer mode]
- ef 10 02 00 00 00 a0 00 01:44:54.778 SET FEATURES [Reserved for Serial ATA]
- Error 2976 occurred at disk power-on lifetime: 17926 hours (746 days + 22 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 41 02 3c f5 4e 60 Error: UNC at LBA = 0x004ef53c = 5174588
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 08 00 38 f5 4e 40 08 01:44:50.945 READ FPDMA QUEUED
- ef 10 02 00 00 00 a0 00 01:44:50.945 SET FEATURES [Reserved for Serial ATA]
- ec 00 00 00 00 00 a0 00 01:44:50.944 IDENTIFY DEVICE
- ef 03 45 00 00 00 a0 00 01:44:50.944 SET FEATURES [Set transfer mode]
- ef 10 02 00 00 00 a0 00 01:44:50.944 SET FEATURES [Reserved for Serial ATA]
- Error 2975 occurred at disk power-on lifetime: 17926 hours (746 days + 22 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 41 02 3c f5 4e 60 Error: UNC at LBA = 0x004ef53c = 5174588
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 08 00 38 f5 4e 40 08 01:44:47.111 READ FPDMA QUEUED
- ef 10 02 00 00 00 a0 00 01:44:47.111 SET FEATURES [Reserved for Serial ATA]
- ec 00 00 00 00 00 a0 00 01:44:47.111 IDENTIFY DEVICE
- ef 03 45 00 00 00 a0 00 01:44:47.111 SET FEATURES [Set transfer mode]
- ef 10 02 00 00 00 a0 00 01:44:47.110 SET FEATURES [Reserved for Serial ATA]
- Error 2974 occurred at disk power-on lifetime: 17926 hours (746 days + 22 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 41 02 3c f5 4e 60 Error: UNC at LBA = 0x004ef53c = 5174588
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 08 00 38 f5 4e 40 08 01:44:43.278 READ FPDMA QUEUED
- ef 10 02 00 00 00 a0 00 01:44:43.278 SET FEATURES [Reserved for Serial ATA]
- ec 00 00 00 00 00 a0 00 01:44:43.277 IDENTIFY DEVICE
- ef 03 45 00 00 00 a0 00 01:44:43.277 SET FEATURES [Set transfer mode]
- ef 10 02 00 00 00 a0 00 01:44:43.277 SET FEATURES [Reserved for Serial ATA]
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed: read failure 90% 17931 5174588
- # 2 Short offline Completed: read failure 90% 17911 5174588
- # 3 Short offline Completed: read failure 90% 17911 5174588
- # 4 Short offline Completed: read failure 90% 16656 193930251
- # 5 Short offline Completed: read failure 90% 16633 193930251
- # 6 Short offline Completed: read failure 90% 16633 193930251
- # 7 Short offline Completed: read failure 90% 16632 193930251
- # 8 Short offline Completed: read failure 90% 16632 193930251
- # 9 Short offline Completed: read failure 80% 16632 193930251
- #10 Extended offline Completed: read failure 00% 16628 0
- #11 Extended offline Completed without error 00% 16164 -
- #12 Short offline Completed without error 00% 15064 -
- #13 Extended offline Completed without error 00% 14042 -
- #14 Short offline Completed without error 00% 14040 -
- #15 Short offline Completed without error 00% 13605 -
- #16 Extended offline Interrupted (host reset) 10% 13569 -
- #17 Short offline Completed without error 00% 13550 -
- #18 Short offline Completed without error 00% 13189 -
- #19 Extended offline Aborted by host 10% 13189 -
- #20 Short offline Aborted by host 90% 13100 -
- #21 Extended offline Aborted by host 10% 13100 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.