  1. smartctl 5.41 2011-06-09 r3365 [i686-linux-3.2.0-29-generic-pae] (local build)
  2. Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Device Model:     TOSHIBA MK3255GSX
  6. Serial Number:    49UNT13DT
  7. LU WWN Device Id: 5 000039 1b1b08b9a
  8. Firmware Version: FG010A
  9. User Capacity:    320,072,933,376 bytes [320 GB]
  10. Sector Size:      512 bytes logical/physical
  11. Device is:        Not in smartctl database [for details use: -P showall]
  12. ATA Version is:   8
  13. ATA Standard is:  Exact ATA specification draft version not indicated
  14. Local Time is:    Sun Dec 16 00:29:00 2012 UTC
  15. SMART support is: Available - device has SMART capability.
  16. SMART support is: Enabled
  17.  
  18. === START OF READ SMART DATA SECTION ===
  19. SMART overall-health self-assessment test result: PASSED
  20.  
  21. General SMART Values:
  22. Offline data collection status:  (0x00) Offline data collection activity
  23.                     was never started.
  24.                     Auto Offline Data Collection: Disabled.
  25. Self-test execution status:      (  17) The self-test routine was aborted by
  26.                     the host.
  27. Total time to complete Offline
  28. data collection:        (  120) seconds.
  29. Offline data collection
  30. capabilities:            (0x5b) SMART execute Offline immediate.
  31.                     Auto Offline data collection on/off support.
  32.                     Suspend Offline collection upon new
  33.                     command.
  34.                     Offline surface scan supported.
  35.                     Self-test supported.
  36.                     No Conveyance Self-test supported.
  37.                     Selective Self-test supported.
  38. SMART capabilities:            (0x0003) Saves SMART data before entering
  39.                     power-saving mode.
  40.                     Supports SMART auto save timer.
  41. Error logging capability:        (0x01) Error logging supported.
  42.                     General Purpose Logging supported.
  43. Short self-test routine
  44. recommended polling time:    (   2) minutes.
  45. Extended self-test routine
  46. recommended polling time:    ( 148) minutes.
  47. SCT capabilities:          (0x0039) SCT Status supported.
  48.                     SCT Error Recovery Control supported.
  49.                     SCT Feature Control supported.
  50.                     SCT Data Table supported.
  51.  
  52. SMART Attributes Data Structure revision number: 16
  53. Vendor Specific SMART Attributes with Thresholds:
  54. ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  55.   1 Raw_Read_Error_Rate     0x000b   100   100   050    Pre-fail  Always       -       0
  56.   2 Throughput_Performance  0x0005   100   100   050    Pre-fail  Offline      -       0
  57.   3 Spin_Up_Time            0x0027   100   100   001    Pre-fail  Always       -       1385
  58.   4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       -       1999
  59.   5 Reallocated_Sector_Ct   0x0033   100   100   050    Pre-fail  Always       -       1681
  60.   7 Seek_Error_Rate         0x000b   100   100   050    Pre-fail  Always       -       0
  61.   8 Seek_Time_Performance   0x0005   100   100   050    Pre-fail  Offline      -       0
  62.   9 Power_On_Hours          0x0032   089   089   000    Old_age   Always       -       4440
  63.  10 Spin_Retry_Count        0x0033   139   100   030    Pre-fail  Always       -       0
  64.  12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       1954
  65. 191 G-Sense_Error_Rate      0x0032   100   100   000    Old_age   Always       -       165
  66. 192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       62
  67. 193 Load_Cycle_Count        0x0032   090   090   000    Old_age   Always       -       106475
  68. 194 Temperature_Celsius     0x0022   100   100   000    Old_age   Always       -       34 (Min/Max 15/48)
  69. 196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       -       875
  70. 197 Current_Pending_Sector  0x0032   100   100   000    Old_age   Always       -       366
  71. 198 Offline_Uncorrectable   0x0030   100   100   000    Old_age   Offline      -       0
  72. 199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age   Always       -       0
  73. 220 Disk_Shift              0x0002   100   100   000    Old_age   Always       -       93
  74. 222 Loaded_Hours            0x0032   092   092   000    Old_age   Always       -       3565
  75. 223 Load_Retry_Count        0x0032   100   100   000    Old_age   Always       -       0
  76. 224 Load_Friction           0x0022   100   100   000    Old_age   Always       -       0
  77. 226 Load-in_Time            0x0026   100   100   000    Old_age   Always       -       335
  78. 240 Head_Flying_Hours       0x0001   100   100   001    Pre-fail  Offline      -       0
  79.  
  80. SMART Error Log Version: 1
  81. ATA Error Count: 35914 (device log contains only the most recent five errors)
  82.     CR = Command Register [HEX]
  83.     FR = Features Register [HEX]
  84.     SC = Sector Count Register [HEX]
  85.     SN = Sector Number Register [HEX]
  86.     CL = Cylinder Low Register [HEX]
  87.     CH = Cylinder High Register [HEX]
  88.     DH = Device/Head Register [HEX]
  89.     DC = Device Command Register [HEX]
  90.     ER = Error register [HEX]
  91.     ST = Status register [HEX]
  92. Powered_Up_Time is measured from power on, and printed as
  93. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  94. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  95.  
  96. Error 35914 occurred at disk power-on lifetime: 4437 hours (184 days + 21 hours)
  97.   When the command that caused the error occurred, the device was active or idle.
  98.  
  99.   After command completion occurred, registers were:
  100.   ER ST SC SN CL CH DH
  101.   -- -- -- -- -- -- --
  102.   40 51 02 16 a7 2d e7  Error: UNC 2 sectors at LBA = 0x072da716 = 120432406
  103.  
  104.   Commands leading to the command that caused the error were:
  105.   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  106.   -- -- -- -- -- -- -- --  ----------------  --------------------
  107.   c8 00 08 10 a7 2d e7 00      10:14:30.991  READ DMA
  108.   27 00 00 00 00 00 e0 00      10:14:30.991  READ NATIVE MAX ADDRESS EXT
  109.   ec 00 00 00 00 00 a0 00      10:14:30.983  IDENTIFY DEVICE
  110.   ef 03 42 00 00 00 a0 00      10:14:30.983  SET FEATURES [Set transfer mode]
  111.   27 00 00 00 00 00 e0 00      10:14:30.983  READ NATIVE MAX ADDRESS EXT
  112.  
  113. Error 35913 occurred at disk power-on lifetime: 4437 hours (184 days + 21 hours)
  114.   When the command that caused the error occurred, the device was active or idle.
  115.  
  116.   After command completion occurred, registers were:
  117.   ER ST SC SN CL CH DH
  118.   -- -- -- -- -- -- --
  119.   40 51 02 16 a7 2d e7  Error: UNC 2 sectors at LBA = 0x072da716 = 120432406
  120.  
  121.   Commands leading to the command that caused the error were:
  122.   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  123.   -- -- -- -- -- -- -- --  ----------------  --------------------
  124.   c8 00 08 10 a7 2d e7 00      10:14:27.111  READ DMA
  125.   27 00 00 00 00 00 e0 00      10:14:27.111  READ NATIVE MAX ADDRESS EXT
  126.   ec 00 00 00 00 00 a0 00      10:14:27.104  IDENTIFY DEVICE
  127.   ef 03 42 00 00 00 a0 00      10:14:27.103  SET FEATURES [Set transfer mode]
  128.   27 00 00 00 00 00 e0 00      10:14:27.103  READ NATIVE MAX ADDRESS EXT
  129.  
  130. Error 35912 occurred at disk power-on lifetime: 4437 hours (184 days + 21 hours)
  131.   When the command that caused the error occurred, the device was active or idle.
  132.  
  133.   After command completion occurred, registers were:
  134.   ER ST SC SN CL CH DH
  135.   -- -- -- -- -- -- --
  136.   40 51 02 16 a7 2d e7  Error: UNC 2 sectors at LBA = 0x072da716 = 120432406
  137.  
  138.   Commands leading to the command that caused the error were:
  139.   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  140.   -- -- -- -- -- -- -- --  ----------------  --------------------
  141.   c8 00 08 10 a7 2d e7 00      10:14:23.256  READ DMA
  142.   27 00 00 00 00 00 e0 00      10:14:23.256  READ NATIVE MAX ADDRESS EXT
  143.   ec 00 00 00 00 00 a0 00      10:14:23.248  IDENTIFY DEVICE
  144.   ef 03 42 00 00 00 a0 00      10:14:23.248  SET FEATURES [Set transfer mode]
  145.   27 00 00 00 00 00 e0 00      10:14:23.248  READ NATIVE MAX ADDRESS EXT
  146.  
  147. Error 35911 occurred at disk power-on lifetime: 4437 hours (184 days + 21 hours)
  148.   When the command that caused the error occurred, the device was active or idle.
  149.  
  150.   After command completion occurred, registers were:
  151.   ER ST SC SN CL CH DH
  152.   -- -- -- -- -- -- --
  153.   40 51 02 16 a7 2d e7  Error: UNC 2 sectors at LBA = 0x072da716 = 120432406
  154.  
  155.   Commands leading to the command that caused the error were:
  156.   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  157.   -- -- -- -- -- -- -- --  ----------------  --------------------
  158.   c8 00 08 10 a7 2d e7 00      10:14:19.400  READ DMA
  159.   27 00 00 00 00 00 e0 00      10:14:19.400  READ NATIVE MAX ADDRESS EXT
  160.   ec 00 00 00 00 00 a0 00      10:14:19.392  IDENTIFY DEVICE
  161.   ef 03 42 00 00 00 a0 00      10:14:19.392  SET FEATURES [Set transfer mode]
  162.   27 00 00 00 00 00 e0 00      10:14:19.392  READ NATIVE MAX ADDRESS EXT
  163.  
  164. Error 35910 occurred at disk power-on lifetime: 4437 hours (184 days + 21 hours)
  165.   When the command that caused the error occurred, the device was active or idle.
  166.  
  167.   After command completion occurred, registers were:
  168.   ER ST SC SN CL CH DH
  169.   -- -- -- -- -- -- --
  170.   40 51 02 16 a7 2d e7  Error: UNC 2 sectors at LBA = 0x072da716 = 120432406
  171.  
  172.   Commands leading to the command that caused the error were:
  173.   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  174.   -- -- -- -- -- -- -- --  ----------------  --------------------
  175.   c8 00 08 10 a7 2d e7 00      10:14:15.524  READ DMA
  176.   27 00 00 00 00 00 e0 00      10:14:15.524  READ NATIVE MAX ADDRESS EXT
  177.   ec 00 00 00 00 00 a0 00      10:14:15.516  IDENTIFY DEVICE
  178.   ef 03 42 00 00 00 a0 00      10:14:15.516  SET FEATURES [Set transfer mode]
  179.   27 00 00 00 00 00 e0 00      10:14:15.516  READ NATIVE MAX ADDRESS EXT
  180.  
  181. SMART Self-test log structure revision number 1
  182. Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
  183. # 1  Extended offline    Aborted by host               10%      3188         -
  184.  
  185. SMART Selective self-test log data structure revision number 1
  186.  SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
  187.     1        0        0  Not_testing
  188.     2        0        0  Not_testing
  189.     3        0        0  Not_testing
  190.     4        0        0  Not_testing
  191.     5        0        0  Not_testing
  192. Selective self-test flags (0x0):
  193.   After scanning selected spans, do NOT read-scan remainder of disk.
  194. If Selective self-test is pending on power-up, resume after 0 minute delay.