- smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.2.0-23-generic] (local build)
- Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
- === START OF INFORMATION SECTION ===
- Model Family: Western Digital Caviar Serial ATA
- Device Model: WDC WD800BD-22LRA1
- Serial Number: WD-WMAM9ZY73839
- Firmware Version: 10.01E01
- User Capacity: 80,026,361,856 bytes [80.0 GB]
- Sector Size: 512 bytes logical/physical
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: 7
- ATA Standard is: Exact ATA specification draft version not indicated
- Local Time is: Fri Jul 20 18:36:58 2012 IST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- See vendor-specific Attribute list for marginal Attributes.
- General SMART Values:
- Offline data collection status: (0x84) Offline data collection activity
- was suspended by an interrupting command from host.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 2700) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 35) minutes.
- Conveyance self-test routine
- recommended polling time: ( 6) minutes.
- SCT capabilities: (0x103f) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 200 200 051 Pre-fail Always - 11897
- 3 Spin_Up_Time 0x0003 169 167 021 Pre-fail Always - 2533
- 4 Start_Stop_Count 0x0032 097 097 000 Old_age Always - 3766
- 5 Reallocated_Sector_Ct 0x0033 148 148 140 Pre-fail Always - 412
- 7 Seek_Error_Rate 0x000f 200 200 051 Pre-fail Always - 48
- 9 Power_On_Hours 0x0032 087 087 000 Old_age Always - 9522
- 10 Spin_Retry_Count 0x0013 100 100 051 Pre-fail Always - 0
- 11 Calibration_Retry_Count 0x0012 100 100 051 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 097 097 000 Old_age Always - 3732
- 190 Airflow_Temperature_Cel 0x0022 070 035 045 Old_age Always In_the_past 30
- 194 Temperature_Celsius 0x0022 113 078 000 Old_age Always - 30
- 196 Reallocated_Event_Count 0x0032 106 106 000 Old_age Always - 94
- 197 Current_Pending_Sector 0x0012 181 150 000 Old_age Always - 249
- 198 Offline_Uncorrectable 0x0010 200 125 000 Old_age Offline - 11
- 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
- 200 Multi_Zone_Error_Rate 0x0009 200 154 051 Pre-fail Offline - 1
- SMART Error Log Version: 1
- ATA Error Count: 11310 (device log contains only the most recent five errors)
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 11310 occurred at disk power-on lifetime: 9515 hours (396 days + 11 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 04 d4 a5 cc e0 Error: UNC 4 sectors at LBA = 0x00cca5d4 = 13411796
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 08 d0 a5 cc 00 00 06:51:09.883 READ DMA
- c8 00 80 d0 a5 cc 00 00 06:51:08.007 READ DMA
- c8 00 08 c8 c8 1e 01 00 06:51:08.007 READ DMA
- c8 00 08 c8 c8 1e 01 00 06:51:08.007 READ DMA
- ca 00 08 c8 c8 1e 01 00 06:51:08.007 WRITE DMA
- Error 11309 occurred at disk power-on lifetime: 9515 hours (396 days + 11 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 d4 a5 cc e0 Error: UNC at LBA = 0x00cca5d4 = 13411796
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 80 d0 a5 cc 00 00 06:51:08.007 READ DMA
- c8 00 08 c8 c8 1e 01 00 06:51:08.007 READ DMA
- c8 00 08 c8 c8 1e 01 00 06:51:08.007 READ DMA
- ca 00 08 c8 c8 1e 01 00 06:51:08.007 WRITE DMA
- 40 00 08 c8 c8 1e 01 00 06:51:08.000 READ VERIFY SECTOR(S)
- Error 11308 occurred at disk power-on lifetime: 9515 hours (396 days + 11 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 c8 a5 cc e0 Error: UNC at LBA = 0x00cca5c8 = 13411784
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 08 c8 a5 cc 00 00 06:51:06.035 READ DMA
- c8 00 80 c8 a5 cc 00 00 06:51:04.058 READ DMA
- c8 00 08 98 c8 1e 01 00 06:51:04.058 READ DMA
- ca 00 08 98 c8 1e 01 00 06:51:04.058 WRITE DMA
- 40 00 08 98 c8 1e 01 00 06:51:04.058 READ VERIFY SECTOR(S)
- Error 11307 occurred at disk power-on lifetime: 9515 hours (396 days + 11 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 c8 a5 cc e0 Error: UNC at LBA = 0x00cca5c8 = 13411784
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 80 c8 a5 cc 00 00 06:51:04.058 READ DMA
- c8 00 08 98 c8 1e 01 00 06:51:04.058 READ DMA
- ca 00 08 98 c8 1e 01 00 06:51:04.058 WRITE DMA
- 40 00 08 98 c8 1e 01 00 06:51:04.058 READ VERIFY SECTOR(S)
- c8 00 08 c0 a5 cc 00 00 06:51:02.136 READ DMA
- Error 11306 occurred at disk power-on lifetime: 9515 hours (396 days + 11 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 c0 a5 cc e0 Error: UNC at LBA = 0x00cca5c0 = 13411776
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 08 c0 a5 cc 00 00 06:51:02.136 READ DMA
- c8 00 80 c0 a5 cc 00 00 06:51:00.251 READ DMA
- c8 00 08 90 c8 1e 01 00 06:51:00.251 READ DMA
- c8 00 08 90 c8 1e 01 00 06:51:00.251 READ DMA
- ca 00 08 90 c8 1e 01 00 06:51:00.250 WRITE DMA
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Extended offline Completed: read failure 90% 9508 861838
- # 2 Short offline Completed: read failure 60% 9508 861838
- # 3 Short offline Completed without error 00% 5390 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.