- root@server:/etc/vz/conf# hpacucli ctrl all show config detail
- FIRMWARE UPGRADE REQUIRED: A firmware update is recommended for this controller
- to prevent rare potential data write errors on a
- RAID 1 or RAID 1+0 volume in a scenario of
- concurrent background surface analysis and I/O write
- operations. Please refer to Customer Advisory
- c01587778 which can be found at hp.com.
- Smart Array P400i in Slot 0 (Embedded)
- Bus Interface: PCI
- Slot: 0
- Serial Number: PH84MQ7892
- Cache Serial Number: PA82C0H9SVMC4Y
- RAID 6 (ADG) Status: Enabled
- Controller Status: OK
- Hardware Revision: D
- Firmware Version: 4.12
- Rebuild Priority: Medium
- Expand Priority: Medium
- Surface Scan Delay: 15 secs
- Surface Scan Mode: Idle
- Post Prompt Timeout: 0 secs
- Cache Board Present: True
- Cache Status: Temporarily Disabled
- Cache Status Details: Cache disabled; low batteries.
- Cache Ratio: 25% Read / 75% Write
- Drive Write Cache: Disabled
- Total Cache Size: 256 MB
- Total Cache Memory Available: 208 MB
- No-Battery Write Cache: Disabled
- Cache Backup Power Source: Batteries
- Battery/Capacitor Count: 1
- Battery/Capacitor Status: Failed (Replace Batteries)
- SATA NCQ Supported: True