- smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.13.0-24-generic] (local build)
- Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Device Model: ST500LT012-9WS142
- Serial Number: S0VASBEZ
- LU WWN Device Id: 5 000c50 06c9252b7
- Firmware Version: 0001LVM1
- User Capacity: 500 107 862 016 bytes [500 GB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 5400 rpm
- Device is: Not in smartctl database [for details use: -P showall]
- ATA Version is: ATA8-ACS T13/1699-D revision 4
- SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
- Local Time is: Wed Jun 4 22:12:07 2014 YEKT
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- See vendor-specific Attribute list for marginal Attributes.
- General SMART Values:
- Offline data collection status: (0x82) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 0) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: ( 103) minutes.
- Conveyance self-test routine
- recommended polling time: ( 2) minutes.
- SCT capabilities: (0x1031) SCT Status supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 10
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 119 099 034 Pre-fail Always - 218543632
- 3 Spin_Up_Time 0x0003 099 099 000 Pre-fail Always - 0
- 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 222
- 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x000f 066 060 030 Pre-fail Always - 5099975
- 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 506 (79 112 0)
- 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 208
- 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
- 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
- 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 1
- 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
- 190 Airflow_Temperature_Cel 0x0022 052 042 045 Old_age Always In_the_past 48 (0 17 55 47 0)
- 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 14
- 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 20
- 193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 1140
- 194 Temperature_Celsius 0x0022 048 058 000 Old_age Always - 48 (0 16 0 0 0)
- 196 Reallocated_Event_Count 0x000f 100 100 030 Pre-fail Always - 502 (20455 0)
- 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
- 254 Free_Fall_Sensor 0x0032 100 100 000 Old_age Always - 0
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Extended offline Completed without error 00% 506 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.